Protection class. Male 8 pin socket M12 (ADCANOP: 5 pin socket)

Similar documents
POSIWIRE. WS10SG Position Sensor. Cable Extension Position Sensors. Datasheet

POSIWIRE. WS12 Position Sensor. Cable Extension Position Sensors. Datasheet

Protection class U8 I1. Linearity ±0.10 % f. s. (standard); optional ±0.05 % WB10ZG

Protection class U8 I1. Linearity ±0.10 % f. s. (standard); optional ±0.05 % WB10ZG

U8 I1. Linearity ±0.10 % f. s.; optional ±0.05 % WB12

U8 I1. Linearity ±0.10 % f. s. (standard); optional ±0.05 % WB61

Measurement range. Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( )

POSICHRON PCRP32 Round Profile Housing with Analog Output

W(G)S3.1 Position Sensor with Analog or A/D converted synchronous serial output

Ranges >500 mm: L10 = ±0.10 % f.s. L02 = ±0.02 % f.s. Ranges 500 mm: L10 = ±0.5 mm L02MM = ±0.2 mm Repeatability ±3 µm

Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( )

POSICHRON position sensor in square profile. Protection class

POSIWIRE. WS85 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

Clamps, mounting plate EN :1993, 100 g/11 ms, 100 shocks EN :1995, 20 g 10 Hz-2 khz, 10 cycles Life cycle of bearings

Extremely robust Inclination Sensor with Analog Output U8 I1. Measurement range ±180 for 1 axis or ±60 for 2 axes. 5 pin connector M12 axial or radial

Extremely robust Inclination Sensor with Analog Output U8 I1. Measurement range ±180 for 1 axis or ±60 for 2 axes. 5 pin connector M12 axial or radial

Ultra flat POSICHRON position sensor. Current Resolution

POSICHRON rod-style position sensor PCST25

Outputs U8 I1. Protection class IP64 (IP67) WB25KT

Universal MEMS Inclination Sensor with Analog Output. Output /Excitation U6 U8 I1

Outputs U8 I1. Protection class IP64 (IP67) WB25

Ranges >500 mm: L10 = ±0.10 % f.s. L02 = ±0.02 % f.s. Ranges 500 mm: L10 = ±0.5 mm L02MM = ±0.2 mm Repeatability ±3 µm. 4 pin socket M8 / cable 2 m

Protection Class (IEC 529)

Extremely robust Inclination Sensor with Analog Output U8 I1. Measurement range ±180 for 1 axis or ±60 for 2 axes

POSIROT. PRAS7 Magnetic Angle Sensor. Magnetic Angle Sensors. Datasheet

Universal MEMS Inclination Sensor with Analog Output. Output /Excitation U6 U8 I1

U6 I1/I1B. Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( ) Linearity

POSICHRON position sensor in a stainless steel pressure tube. Protection class IP68/IP69K

POSIROT. PRAS3 Magnetic Angle Sensor. Magnetic Angle Sensors. Datasheet

POSIHALL. PH68 Magnetic Multiturn Angle Sensor. Magnetic Multiturn Angle Sensors. Datasheet

POSICHRON rod-style position sensor. Thread M18x1,5 / thread ¾ inch. 8 pin socket M12, cable 2 m PCST24

POSIHALL. PH36 Magnetic Multiturn Angle Sensor. Magnetic Multiturn Angle Sensors. Datasheet

POSICHRON rod-style position sensor

POSICHRON position sensor in square profile

Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( )

Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( )

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire

Protection class IP67/IP69K Magnetic measurement principle

WS12EX Position Sensor with Analog output Dust explosion-proof

PMIS2 POSIMAG Magnetoresistive Position Sensor with Incremental Output

Protection class IP67/IP69K Magnetic measurement principle

0.04 mm Distance/revolution mm ±0.05% f. s.; ±0.01% f. s. as option. Measurement range (in mm) 2500 (smaller measurement ranges included)

Measurement range Protection class IP67 / IP69K Incremental encoder output With.39 shaft or non-contact Magnetic measurement principle

WS Position Sensors. Installation and operation manual. Please read carefully before installation and operation!

Mounting M12 x 1 EN :1993, 100 g/11 ms, 100 shocks EN :1995, 20 g 10 Hz-2 khz, 10 cycles

Mounting M12 x 1 EN :1993, 100 g/11 ms, 100 shocks EN :1995, 20 g 10 Hz-2 khz, 10 cycles

Outputs Voltage: V; V

POSIWIRE. Cable Extension Position Sensors Installation and operation manual. Please read carefully before installation and operation!

POSIROT. PRAS3EX Magnetic Angle Sensor. Magnetic Angle Sensors (Dust-Ex-proof) Datasheet

Measurement range. Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( )

Absolute encoders - SSI

NOVOHALL Rotary Sensor non-contacting. Series RSC-2800

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders 18 bit ST / 12 bit MT

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

POSITAPE. Tape Position Sensors WB Series Installation and operation manual. Please read carefully before operation!

NOVOTURN Multiturn Sensor non-contacting. Series RSM-2800

POSIROT. PMIS4, PMIR5 Magnetic incremental encoder. Magnetic wheels for rotative applications PMIS4, PMIR5

Absolute encoders - SSI Shaft with clamping or synchro flange Optical multiturn encoders 14 bit ST / 12 bit MT

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

Incremental encoders Blind or through hollow shaft ø12 mm pulses per revolution

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.

Absolute Encoders Multiturn

ABSOLUTE ROTARY ENCODER SSI

Technical data. General specifications V DC No-load supply current I 0. typ. 50 ma Power consumption P 0

Technical data. General specifications. Linearity error ± 0.1 Electrical specifications Operating voltage U B

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

POSITAPE. Tape Position Sensors Installation and operation manual. Please read carefully before installation and operation!

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm. Perfect data processing I 7 I

ABSOLUTE ROTARY ENCODER CAN-BUS

XXXX e. X d.. X X X a

ABSOLUTE ROTARY ENCODER DEVICE NET

PMIS3 POSIMAG Magnetic Scale Position Sensor

POSIROT / PRDS. Digital Magnetic Angle Sensors Installation and operation manual. Please read carefully before installation and operation!

ABSOLUTE ROTARY ENCODER SSI

maxon document number:

ABSOLUTE ROTARY ENCODER SSI

TECHNICAL DATASHEET #TDAX Universal Signal Inputs CAN Controller V, ma, Digital, PWM, Hz/RPM, Counter Inputs CANopen P/N: AX030121

Technical data. General specifications V DC Power consumption P 0. 1 W Time delay before availability t v

300 ma max. 2 mm ,8 mm. ±1 mm. ±1 Digit. A, A, B, B / signal Z, Z (optional) / status signal ERR (optional) Zinc die casting IP67

Absolute Encoders - Singleturn

Magnetic absolute single-turn encoder BMSH MAGRES parallel

Incremental Encoder Model: FOI58

RoHS. High shaft load capacity. Shock / vibration resistant

MHAD 50 - HDmag. Features

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

Absolute Encoders - Singleturn

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 700 a at 40 C Mission Time (T M ) L 10

NOVOHALL Rotary Sensor touchless transmissive. Series RFX-6900

Material: Weight: Shaft Loads:

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 700 a at 40 C Mission Time (T M ) L 10

ABSOLUTE ROTARY ENCODER SSI PROGRAMMABLE

Highlights Very compact EtherCAT I/O system in IP 20 for plug-in into a circuit board (signal distribution board)

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

Temposonics. Magnetostrictive Linear Position Sensors. ER SSI Data Sheet

Online data sheet AFS60A-BJPA AFS/AFM60 SSI ABSOLUTE ENCODERS

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

Multiturn absolute encoder

Transcription:

WS10SG Analog, SSI or CANopen Output Very compact sensor for industrial applications Protection class IP65 Measurement range 0... 100 mm to 0... 1250 mm Analog output or A/D converted synchronous serial output (SSI) or A/D converted CANopen output Specifications Outputs Resolution Linearity Sensing device Material Protection class Weight EMC, temperature Potentiometer 1 kω Voltage 0... 10 V Current 4... 20 ma, 2 or 3 wire Voltage or current output, programmable (PMUV/PMUI) A/D converted synchronous serial interface (SSI) A/D converted CANopen bus Analog: essentially infinite ADSI16: max. 16 bit f.s. ADCANOP: 16 bit f.s. Up to ±0.05% f.s. Precision potentiometer Aluminum, stainless steel and plastic; cable: stainless steel IP65 (with mating connector only) Male 8 pin socket M12 (ADCANOP: 5 pin socket) 350 g approx. Refer to output specification Order code WS10 Model name WS10SG Order code connector cable: see page 82/83 Measurement range (in mm) 100 / 125 / 375 / 500 / 750 / 1000 / 1250 Output R1K = Potentiometer 1 kω 10V = 0... 10 V signal conditioner 420A = 4... 20 ma signal conditioner 420T = 4... 20 ma signal conditioner PMUV/PMUI = Programmable 0... 10 V or 4... 20 ma signal conditioner ADSI16 = A/D converted synchronous serial interface 16 bit (12 or 14 bit opt.) ADCANOP = A/D converted CANopen bus Linearity L10 = ±0.10 % option: L05 = ±0.05 % L25 = ±0.25 % Cable fixing M4 = M4 cable fixing SB0 = Cable clip M12 = 8 pin socket M12 (not for ADCANOP) M12/CAN = 5 pin socket M12 (only for ADCANOP) Order example: WS10SG - 1250-10V - L10 - M4 - M12 6 CAT-WS-E-09 ASM GmbH

WS10SG Analog, SSI or CANopen Output Cable forces, typical at 20 C Measurement range Max. pull-out force Min. pull-in force [mm] [N] [N] 100 4.7 3.0 125 4.6 2.4 375 7.4 3.9 500 5.5 2.8 750 7.6 3.8 1000 5.3 2.9 1250 4.6 2.4 Outline drawing 20 [.787] 15,2 [.598] Option SB0 6,1 [.240] 38,5 [1.516] M5-8 [.315] tief/ deep M4 14 [.551] 133 3 [ 5.236 0.118 ] 69,4 [2.732] 20 [.787] M5-8 [.315] tief/ deep 49,5 [1.949] 25,2 [.992] 119 2 [ 4.685 0.079 ] 15,2 [.598] 38,5 [1.516] 95 [3.740] 50,4 [1.984] 25,2 [.992] 19,3 [.760] 18,2 [.717] Dimensions in mm [inch] 25 [.984] A 31 [1.220] Dimensions informative only. For guaranteed dimensions consult factory. Dimensions in mm Measurement range A 375; 750 12.4 100; 125; 500; 1000; 1250 8 ASM GmbH CAT-WS-E-09 7

WS10 Incremental Encoder Output Very compact sensor for industrial applications Protection class IP65 Measurement range 0... 1250 mm Incremental encoder output Specifications Outputs Resolution Linearity Sensing device Material Protection class Weight EMC, temperature Incremental encoder output with differential push-pull circuit for reliable data transmission. The output is compatible with TTL and HTL. 10 or 25 pulses per mm (1/40 mm or 1/100 mm with external edge counting mode) ±0.05% f.s. Incremental encoder Aluminum, stainless steel and plastic; cable: stainless steel IP65 (with mating connector only) Male 8 pin socket M12 Approx. 400 g Refer to output specification Order code WS10SG Model name WS10SG Measurement range (in mm) 1250 Pulses per mm 10 = 10 pulses per mm 25 = 25 pulses per mm Other numbers of pulses on request Output PP530 = Incremental output 5... 30 V IE41LI = Incremental encoder TTL compatible IE41HI = Incremental encoder HTL compatible Cable fixing M4 = M4 cable fixing SB0 = Cable clip M12 = 8 pin socket M12 Order code connector cable: see page 82 Order example: WS10SG - 1250-10 - PP530 - M4 - M12 8 CAT-WS-E-09 ASM GmbH

WS10 Incremental Encoder Output Cable forces, typical at 20 C Resolution Max. pull-out force Min. pull-in force [pulses per mm] [N] [N] 10 / 25 5.8 3.0 Outline drawing 15,2 [0.598] 20 [0.787] 38,5 [1.516] M5-8 [0,315] deep Option SB0 6,1 [0.240] M4 14 [0.551] 119 2 [ 4.699 0 ] 133 3 [ 5.224 0 ] M5-8 [0.315] deep 50,4 [1.984] 25,2 [0.992] 25,2 [0.992] 69 [2.717] 15,2 [0.598] 20 [0.787] 38,5 [1.516] 121 [4.764] 49,5 [1.949] 19 [0.748] 18 [0.709] Dimensions in mm [inch] 25 [0.984] 8 [0.312] 31 [1.219] Dimensions informative only. For guaranteed dimensions consult factory. ASM GmbH CAT-WS-E-09 9

R1K and 10V Analog Output Voltage divider R1K Potentiometer 32 V DC max. at 1 kω (max. power 1 W) Potentiometer impedance 1 kω ±10 % Thermal coefficient ±25 x 10-6 / C f.s. Sensitivity Depends on the measuring range, individual sensitivity of the sensor is specified on the label Voltage divider utilization range Approx. 3 %... 97 % Output signals +Vin +Vout GND The metal wiper of the potentiometer must be protected against current load! Electrical current flow impact on the wiper causes linearity errors and shortens the lifetime of the potentiometer. More information: http:///asm/pdf/pro/ws_poti_technote_en.pdf 10V and 10V5 Voltage output 18... 27 V DC non stabilized 20 ma max. Output voltage 10V: 0... 10 V DC; 10V5: 0.5... 10 V DC Output current 2 ma max. Output load > 5 kω ±50 x 10-6 / C f.s. Protection Reverse polarity, short circuit Output noise 0.5 mv RMS EMC According EN 61326:2006 Output signals 10V 0...10 V Excitation + Excitation GND Signal + Signal GND Signal wiring R1K 10V Cable color +Vin Excitation + White 1 GND Excitation GND Brown 2 +Vout Signal + Green 3 Signal GND Yellow 4 View to sensor connector CONN-M12-8F 58 CAT-WS-E-09 ASM GmbH

420A and 420T Analog Output 420A Current output (2 wire) 12... 27 V DC non stabilized, measured at the sensor terminals 35 ma max. Output current 4... 20 ma equivalent for 0... 100 % range ±100 x 10-6 / C f.s. Protection Reversed polarity, short circuit Output noise 0.5 mv RMS EMC According to EN 61326:2006 Output signals 420A Signal + 4...20 ma Signal 420T Current output (3 wire) 18... 27 V DC non stabilized 40 ma max. Load resistor 350 Ω max. Output current 4... 20 ma equivalent for 0... 100 % range ±50 x 10-6 / C f.s. Protection Reverse polarity, short circuit Output noise 0.5 mv RMS EMC According to EN 61326:2006 Output signals 420T 4...20 ma Excitation + Signal + Excitation GND Signal wiring 420A 420T Cable color Signal + Excitation + White 1 Signal Excitation GND Brown 2 Signal + Green 3 View to sensor connector CONN-M12-8F ASM GmbH CAT-WS-E-09 59

PMUV / PMUI Programmable Analog Output PMUV / PMUI Voltage or current output (3 wire) Voltage output PMUV Output current Output load Current output PMUI Working resistance Scaling Activation of offset and gain adjust Scalable range 18... 27 V DC 50 ma max. 0... 10 V 10 ma max. 1 kω min. 4... 20 ma (3 wire) 500 Ω max. Connect with excitation GND (0 V) 90% max. f.s. ±50 x 10-6 / C f.s. Protection Reversed polarity, short circuit EMC According to EN 61326:2006 Output signals Excitation + Excitation GND PMUV PMUI Signal + Signal GND Offset Gain Signal wiring PMUV / PMUI Excitation + 1 Excitation GND 2 Signal + 3 Signal GND 4 Not used 5 Not used 6 Offset 7 Gain 8 View to sensor connector CONN-M12-8F Signal wiring PMUI2 Excitation + 1 Excitation GND 2 Not used 3 Not used 4 Signal + 5 Signal GND 6 Offset 7 Gain 8 60 CAT-WS-E-09 ASM GmbH

ADCANOP A/D Converted CANopen Bus Interface ADCANOP Specifications Signal diagram Communication profile CANopen CiA 301 V 4.02, Slave Encoder profile Encoder CiA 406 V 3.2 Error Control Node Guarding, Heartbeat, Emergency Message Node ID Adjustable via LSS PDO 3 TxPDO, 0 RxPDO, no linking, static mapping PDO Modes Event-/Time triggered, Remote-request, Sync cyclic/acyclic SDO 1 server, 0 client CAM 2 cams Certified Yes Transmission rates 50 kbaud to 1 MBaud, adjustable via LSS Nodes 127 max. Bus connection M12 connector, 5 pins Integrated bus terminating resistor No Bus, galvanic isolated No 8... 36 V DC Typ. 15/30 ma for 24/12 V, max. 100 ma Resolution 16 bit f.s. Measuring rate 1 khz (asynchronous) ±50 x 10-6 / C f.s. Repeatability 1 LSB Protection Reverse polarity, short circuit Dielectric strength 1 kv (V AC, 50 Hz, 1 min.) Environment - EMC Automation EN 61326:2006 Excitation + ADCANOP Excitation GND CAN-H Signal wiring / connection Shield 1 Excitation + 2 GND 3 CAN-H 4 CAN-L 5 CAN-L View to sensor connector ASM GmbH CAT-WS-E-09 61

PP530 Incremental Output PP530 Incremental Output frequency Output Output current Output voltage Saturation voltage high/low 5... 30 V DC 25 ma typ. (w/o load), 200 ma max. 200 khz max. Linedriver, Push-Pull, CMOS, TTL- and HTLcompatible 30 ma max. Depends on the excitation voltage (e.g. to obtain TTL signals the excitation voltage must be 5 V). Compatible to EIA RS422/RS485 Ia <10 ma, U B 5 V/24 V: <0.5 V Ia <30 ma, U B 5 V/24 V: <1 V ±20 x 10-6 / C f.s. (sensor mechanism) Operation temperature -10... +70 C Storage temperature -30... +80 C Transition time positive edge <200 ns Transition time negative edge <200 ns Protection Reverse polarity, short circuit EMC According to EN 61326:2006 Signal diagram Excitation + Encoder PP530 Excitation GND Signal A Signal A Signal B Signal B Signal Z (reference pulse) Signal Z Recommended processing circuit Signal wiring / connection Output signal name Excitation + 1 Excitation GND (0 V) 2 Signal A 4 Signal A 6 Signal B (A + 90 ) 3 Signal B 5 Signal Z (reference pulse) 7 Signal Z 8 View to sensor connector CONN-M12-8F 62 CAT-WS-E-09 ASM GmbH

IE41LI and IE41HI Incremental Output IE41LI and IE41HI Incremental Output signals IE41LI IE41HI 5 V DC ±10 % 10... 30 V DC 150 ma max. w/o load Output frequency 300 khz max. 200 khz max. Output RS422 Push-pull antivalent Output current ±30 ma max. 30 ma Output voltage Depending on the excitation voltage ±20 x 10-6 / C f.s. (sensor mechanism) Operating temperature -10... +70 C Protection against short circuit One channel for 1 s Yes EMC According to EN 61326:2006 Signal A Signal B Signal Z Recommended processing circuit IE41LI Also for B B Also for Z Z IE41HI Also for B B Also for Z Z Signal wiring / connection WS10 WS12 Excitation + 1 1 Excitation GND (0 V) 2 2 Signal A 4 3 Signal A 6 5 Signal B (A + 90 ) 3 4 Signal B 5 6 Signal Z (reference pulse) 7 7 Signal Z 8 8 View to sensor connector CONN-M12-8F 64 CAT-WS-E-09 ASM GmbH

ADSI16 A/D Converted SSI Output Description ADSI16 A/D converted synchronous serial Resolution 16 bit, synchronous serial data transmission/ssi Optional available with 12 bit (ADSI) or 14 bit (ADSI14) resolution No loss of data at power down Easy to connect to PLC s with SSI input circuitry The sensing device of the ADSI is a precision potentiometer. The position information is given by an analog/digital converter output serialized as a data word. Data transmission takes place by means of the signals CLOCK and DATA. The processing unit (PLC, Micro- computer) sends pulse sequences which clock the data transmission with the required transfer rate. With the first falling edge of a pulse sequence the position of the sensor is recorded and stored. The following rising edges control the bit-by-bit A/D conversion, encoding and output of the data word. After a delay time the next new position information will be transmitted. Interface Clock frequency Code Delay between pulse trains Resolution EIA RS422, RS485, short-circuit proof 11... 27 V DC 200 ma max. 70... 500 khz Gray code, continuous progression 30 µs min. 16 bit (65536 counts) f.s.; optional 12 (ADSI) bit resp. 14 bit (ADSI14) ±50 x 10-6 / C f.s. EMC According to EN 61326:2006 Data format (train of 26 pulses) Recommended processing circuit Sensor circuit DATA Cable Subsequent circuit DATA CLOCK CLOCK GND (0 V) Transmission rate Cable length Baud rate < 50 m < 300 khz < 100 m < 100 khz Note: Extension of the cable length will reduce the maximum transmission rate. Signal wiring Excitation + 1 Excitation GND (0 V) 2 CLOCK 3 CLOCK 4 DATA 5 DATA 6 Shield not connected CONN-M12-8F View to sensor connector 66 CAT-WS-E-09 ASM GmbH

Accessories for WS Position Sensors Connector cable for WS position sensors 8 pin M12 The 8-lead shielded cable is supplied with a mating 8-pin 90 M12 connector at one end and 8 wires at the other end. Available lengths are 2 m, 5 m and 10 m. Wire: cross sectional area 0.25 mm². KAB - XM - M12/8F/W - LITZE IP69K: KAB - XM - M12/8F/W/69K - LITZE Length in m Connector cable for WS position sensors 8 pin M12 The 8-lead shielded cable is supplied with a mating 8-pin M12 connector at one end and 8 wires at the other end. Available lengths are 2 m, 5 m and 10 m. Wire: cross sectional area 0.25 mm². KAB - XM - M12/8F/G - LITZE IP69K: KAB - XM - M12/8F/G/69K - LITZE Length in m Connector cable wiring - M12, 8 pin Connector pin / cable color 1 2 3 4 5 6 7 8 White Brown Green Yellow Gray Pink Blue Red Connector for WS position sensors 8 pin M12 Female connector. CONN - M12-8F - G 20 ~57 18 M12x1 Connector for WS position sensors 12 pin CONIN Female connector. CONN - CONIN - 12F - G 82 CAT-WS-E-09 ASM GmbH

Accessories for WS Position Sensors Connector/bus cable for WS position sensors 5 pin M12 CAN bus/devicenet The 5-lead shielded cable is supplied with a female 5-pin M12 connector at one end and a male 5-pin M12 connector at the other end. Available lengths are 0.3 m, 2 m, 5 m and 10 m. KAB - XM - M12/5F/G - M12/5M/G - CAN IP69K: KAB - XM - M12/5F/G/69K - M12/5M/G/69K - CAN Length in m T-piece for bus cable 5 pin M12 CAN bus/devicenet KAB - TCONN - M12/5M - 2M12/5F - CAN Terminating resistance 5 pin M12 CAN bus/devicenet KAB - RTERM - M12/5M/G - CAN ASM GmbH CAT-WS-E-09 83