DP2500 DP0100 DP0250 Differential Pressure Transmitter

Similar documents
DP2500 DP0100 DP0250 Differential Pressure Transmitter

RSMFX-2R MULTIFUNCTIONAL

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs

Series T. General Eastern Differential Pressure Transmitters. GE Sensing. Description

Series T. Amphenol Advanced Sensors. Differential Pressure Transmitters

HD 9408T BARO - HD 9408TR BARO HD 9908T BARO - HD 9408PS 50

ED701 General Industry Pressure Transmitter

MTV-1-CP 230 VAC POTENTIOMETER WITH MIN & MAX SETTINGS, DRY CONTACT. Mounting and operating instructions

WRZ-RMT10K-0 Wireless Remote Temperature Transmitter

Air flow meter For ventilation and air-conditioning Model A2G-25

Installation Instructions

0.01kV (0 to ±0.99 kv)

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

Series 10-ZSE30A(F)/10-ISE30A

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

QPM Series Indoor Air Quality Duct Sensors

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

Provides line voltage capable single Pole Double-Throw (SPDT) switch and 140Ω, 1KΩ, 2KΩ or 10KΩ feedback potentiometric.

Output Signal Active Temperature. Electrical data Power Supply DC V, ±10%, 0.5 W

Refer to manual. Failure to read message could result in personal injury or serious damage to the equipment or both.

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Electronic Controls For general purpose and multi stages controls. Features and Benefits

Type Overview. Technical Data. Outdoor Humidity, Temperature Sensor

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

Differential pressure sensors

Screw-in resistance thermometers with plug connector

Solid State Pressure Sensors D8M

Series HT-9000 Electronic Humidity Transmitter. Features and Benefits. HT-9000 Electronic Humidity Transmitter

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Correction Reissue. Product Discontinuation Notices

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

PRESSURE SENSORS I INSTALATION AND OPERATION INSTRUCTIONS ACCUTRON MDP BIDIRECTIONAL DIFFERENTIAL PRESSURE SENSOR

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Output Signal Active Note. Output Signal Temperature 22UTH-51 DC V, DC V

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Model 140 Inline Amplifier

OPTITEMP TT 20 Technical Datasheet

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits.

Model SPG. Sapphire capacitance diaphragm gauge

ENGLISH S-CO2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS CO 2. TF5701_B_v1_web

Relative Humidity & Temperature Transmitters

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

Huba Control FEINE MESSIDEEN FÜR DRUCK UND STRÖMUNG FOR FINE PRESSURE AND FLOW MEASUREMENT LA FINESSE DES MESURES DE PRESSION ET DE DEBIT

Indoor, outdoor and duct resistance thermometers

CSI 9330 Vibration Transmitter

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

9330 Vibration Transmitter

OP5U. Pre-programmed, configurable controller for simple applications

TORKEL 900-series Battery Load Unit

TS Temperature Sensor and Transducers. Product Bulletin. Wide range of mounting types and signal outputs

Model: &

Precision humidity control/sensing

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

Electromotoric actuators

Screw-in resistance thermometers with terminal head Form B

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Electromotoric actuators for stroke valves

High Performance Process & Temperature Controllers

PAD - Heavy Duty Differential Pressure Trasmitter

DPS 100 DPS 100. Gauge- / Differential- / Absolute Pressure Transmitter

Safety light curtain to safeguard the hinge edge IMPORTANT NOTE

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Cylindrical type proximity sensor

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Electronic Vacuum Regulator. How to Order ITV S 5. Monitor output

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Analog Data Sheet

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

FX-CM. HQ Color Mark Sensor. Model Number Legend SALIENT FEATURES. Sensors. Proximity. Photoelectric. Sensors

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Optimising controls Vacuum switches

HLC-1000 High-limit Humidity Control

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

ADJUSTABLE SPEED DRIVES FS1

Technical Instructions Document No EA GQD June 23, OpenAir

Dawson DSM150. Digital Light Meter User s Manual

TORKEL 900-series Battery Load Unit

ZM18 Series DATASHEET SENSORPARTNERS.COM. Sensor Partners BVBA Z.1 Researchpark 310 B-1731, Zellik Belgium

s Climatix extension module 26 I/Os POL985.00/XXX

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

Series 10-ZSE80/10-ISE80

02/11/2015

ph or ORP Transmitter

Altitude and Airspeed Measurements Temperature Range. Range psid psig psia 0 to 1 0 to 5 0 to 15 0 to 30 0 to 50 0 to to to 300

E8EB-N0C2B E8EB-N0B2B

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

USER'S GUIDE. Vaisala HUMICAP Humidity and Temperature Transmitters HMD70U/Y U303EN11

Miniature pressure sensor

TxBlock-USB Transmitter

M-2111 Series Ultrasonic Flow Meter

Valve Island with Electronic I/O

Intelligent Communicator DCR3000

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Transcription:

PB_DPT_03 2010 DP2500 DP0100 DP0250 Differential Pressure Transmitter The DP Low Differential Pressure Transmitter series is an accurate and cost competitive solution for measuring low pressures of air and non-aggressive gases in order to monitor and control pressures in building automation, HVAC and clean room systems. The DP series accurately measures low differential pressure and converts the measurement into a standard proportional 0...10 V signal or 4 20mA. The various pressure measurement range are filed selectable with jumpers. 8 measurement ranges in one device Allow selection of best input range for application 4 digit display Shows differential pressure AutoZero option Makes the DP transmitter maintenance free Response time selectable Allow to cover all the customer needs Easy mounting No expert required, reduce time and cost IP54 It can be mounted and several environments

2 PB_DPT_03 2010 Ordering Codes Single Pack with Standard Accessories Selectable Range in Pa Codes DP2500-R8 DP2500-R8-AZ DP2500-R8-D DP2500-R8-AZ-D DP0100-AZ DP0100-AZ-D DP0250-AZ DP0250-AZ-D Description with 8 Ranges - Single Pack with 8 Ranges and AutoZero feature - Single Pack with 8 Ranges and Display - Single Pack with 8 Ranges and AutoZero feature and Display - Single Pack with 2 Ranges (+/-) and AutoZero feature - Single Pack with 2 Ranges (+/-) and AutoZero features and Display - Single Pack with 2 Ranges and AutoZero feature - Single Pack with 2 Ranges and AutoZero feature and Display - Single Pack Auto Zero Display 0...100 0...250 0...500 0...1000 0...1500 0...2000 0...2500 -- -- -- X X X X X X X X X -- -- X X X X X X X X -- X -- X X X X X X X X X X -- X X X X X X X X X -- X X -- -- -- -- -- -- -- X X X X -- -- -- -- -- -- -- X -- -- -- X X -- -- -- -- -- X X -- -- X X -- -- -- -- -- Standard accessories: 2 fixing screws 2 plastic tube connectors 2 m tube Ø 4 / 7 mm Bulk Pack without Standard Accessories Selectable Range in Pa Codes DP2500-R8-01 DP2500-R8-AZ-01 DP0100-AZ-01 Description with 8 Ranges - Bulk Pack - 46 pcs with 8 Ranges and AutoZero feature - Bulk Pack - 46 pcs with 2 Ranges (+/-) and AutoZero feature - Bulk Pack - 46 pcs Auto Zero Display 0...100 0...250 0...500 0...1000 0...1500 0...2000 0...2500 -- -- -- X X X X X X X X X -- -- X X X X X X X X X -- X X -- -- -- -- -- -- --

PB_DPT_03 2010 3 Application This product converts the differential pressure between the + / - pressure ports to an analog output signal. The DP differential pressure transmitter contains a micro-machine, single-crystal silicon, piezoresistive pressure sensor with strain gauges to change resistance as a function of applied pressure. Dimensions 90.0 36.0 Installation The installation of electrical wiring must conform to local codes and should be carried out by authorized personnel only. Users should ensure that all Johnson Controls products are used safely and without risk to health or property. 71.5 DP 95.0 The DP series differential pressure transmitter are intended to provide input to equipment under normal operating conditions. Where failure or malfunction of an DP series differential pressure transmitter could lead to an abnormal operating condition that could cause personal injury or damage to the equipment or other property, other devices (limit or safety controls) or systems (alarm or supervisory) intended to warn of, or protect against, failure or malfunction of the DP series must be incorporated into and maintained as part of the control system. Wirings Before connecting or disconnecting any wires, ensure that all power supplies have been switched off and all wires are potential-free to prevent equipment damage and avoid electrical shock. Terminations are made on the terminal blocks in the base of the module, which accept up to 1.5 mm 2 wires. Follow the wiring diagrams shown in the figure below. All wiring to the module is at extra low (safe) voltage and must be separated from power line voltage wiring. Do not run wiring close to transformers or high frequency generating equipment. Complete and verify all wiring connections before applying power to the controller to which the module is connected. Output 0...10V Output 4...20mA V A + Power supply 24 VDC / 24 VAC 0-10V 4-20mA 24V GND

4 PB_DPT_03 2010 Operation Selecting Pressure Range To adjust the pressure range, set the jumpers as shown. The pressure values on the sticker depends on the model Jumpers LED Pa 100Pa 250Pa 500Pa ZERO 0-10V 4-20mA 24VDC GND 1000Pa 1500Pa 2000Pa 2500Pa Zeroing It is recommended to adjust the zero point every 12 months during normal operation. How to do: Note! Supply voltage must be connected one hour before the 0-point adjustment is carried out. 1) Loose both tubes from the pressure inlets + and. 2) Push zero button >4 seconds and the red led turns ON. 3) Wait until LED turns off and then install tubes again to the pressure inlets. AutoZero (-AZ) option Optional auto zero function makes the DP transmitter maintenance free for periodical zero point adjustment. Element automatically adjusts the transmitters zero point from time to time, this eliminates the zero point long term drift of the piezoresistive sensing element. Zero point adjustment is carried out every 10 minutes. During zero point adjustment the output and display values will freeze to the latest measured value. The automatic zero point adjustment takes 4 seconds. During this time power consumption can be up to 1,7 W. Response time selection DP2500 Series This model is equipped of a push button for response time selection (0.8 or 4 sec). RESPONSE TIME CHANGE: press the button shortly <1s as shown LED 3 x short blink means 0,8s selected <1s <1s LED 2 x long blink means 4s selected DP0100 and DP0250 Series This models are equipped of a jumper for response time selection (0.8 or 4 sec). Jumpers 2-range model e.g. DP0100 without jumper jumper 0,8s 4s ZERO 0.8/4s The pressure values on the sticker depends on the model Display (-D) option For local differential pressure visualization there are optional models (-D versions) with a 4-digit display. All values indicated in this LCD display are as default in Pascal.

PB_DPT_03 2010 5 Technical Specification Pressure Ranges DP2500 DP0100 DP0250 Accuracy Response Time Max. pressure Bursting pressure Suitable media Measuring element Electrical interface (3-wire) Materials Connections Weight Dimensions General Ambient Condition Safety Supply Voltage Max. Tolerance Power Consumption Output Signal Housing Cover Pressure Connections Duct Connectors Tubing Electrical Connections Cable Entry Pressure Connections Temperature Range Operation Storage Ambient Humidity Protection Standard Conformance Pa 0...100 Pa 0...250 Pa 0...500 Pa 0...1000 Pa 0...1500 Pa 0...2000 Pa 0...2500 Pa ±1,5% or (±6 Pa < 250 Pa) of selected pressure range 0.8 / 4s selectable by jumper 25 kpa 50 kpa Air and non-aggressive gases Piezoresistive Pa Pa ±1,5% of full scale 24 VAC or VDC ±10% <1.0 W (<1.5 W with Iout 20 ma) 0 10 VDC, Load R minimum 1kΩ or 4 20 ma, maximum load 500Ω PVC, soft 4 screw terminals, max 1.5 mm 2 M16 Male 5,0 mm and 6,3 mm 150 grams, with accessories 290 grams 90,0 x 71,5 x 36,0 mm -10 +50 C (-5 +50 C for AZ model) -20 +70 C 0 to 95% RH IP54 Meets the requirements for CE marking: EMC directive: 2004/108/EC Rohs Directive: 2002/95/EY 0...100 Pa 0...250 Pa Building Efficiency Headquarters: Milwaukee, Wisconsin, USA Branch Officies: Principal Cities World-wide Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2010 Johnson Controls, Inc. Published in Europe www.johnsoncontrols.com