Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)

Similar documents
LSA Pole. R 726 Mains paralleling

PARTNER ALTERNATORS LSA Pole

Low Voltage alternators - 4 pole LSA 47.2

Low Voltage alternators - 4 pole LSA 46.2

PARTNER ALTERNATORS LSA 40-4 Pole

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

ALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx

TAL 049 Low Voltage Alternator - 4 pole

TAL 047 Low Voltage Alternator - 4 pole

TAL 044 Low Voltage Alternator - 4 pole

WDG 51 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

S0L1-J1 - Technical Data Sheet

WDG 61 - Technical Data Sheet

S4L1S-D4 Wdg.17 - Technical Data Sheet

WDG 71 - Technical Data Sheet

WDG 83 - Technical Data Sheet

WDG 07 - Technical Data Sheet

WDG 12 - Technical Data Sheet

S4L1D-G41 Wdg Technical Data Sheet

WDG 13 - Technical Data Sheet

WDG 12 - Technical Data Sheet

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Technical Data Sheet

PI734A - Technical Data Sheet

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

4939 en / a PARTNER ALTERNATORS LSA 54. General features and ratings

440 (12) 416 (12) 416 (12) 440 (12)

PM734B - Technical Data Sheet. Generator Solutions AS

Spec Information. Reactances Per Unit Ohms

GENERATOR DATA JANUARY 30, 2015

AGN 034 Alternator Reactance

Spec Information. Reactances Per Unit Ohms

4938 en / a PARTNER ALTERNATORS LSA General features and rating4

Packaged Generators: New Kato Engineering Packaged Generator Line: Over 75 Years of Experience: Conformity: Service: Quality Standards:

Generation Interconnection Study Data Sheet Synchronous Machines

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Generator Advanced Concepts

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

Low Voltage Alternators - 4 pole

Low Voltage Alternators

Technical Data Sheet for AvK-Alternators

Technical Data Sheet for AvK-Alternators

Technical Data Sheet for AvK-Alternators

Technical Data Sheet for AvK-Alternators

Application Guidance Notes: Technical Information from Cummins Generator Technologies

AGN 005 Fault Currents and Short Circuit Decrement Curves

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

HCM634G - Technical Data Sheet

R448 & R448 V50 A.V.R. Installation and maintenance R 448 ST5 ST3 ST10. Armature + 6- Field X2 Z1 X1 Z2 E+ E- 0V Slow fuse 250V 10 A

ECP3 4. Rev. 1. Powered by TCPDF (

NPE32 4. Rev. 1. Powered by TCPDF (

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

R448 & R448 V50 A.V.R.

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

Cooling Fans G-17. Cooling Fans G-17. AC Input/Low-Power Consumption EMU Series. AC Input/Compact Size MU Series

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

Impact Assessment Generator Form

r 450 Installation and maintenance This manual is to be given to the end user R 450 VOLT. STAB. I EXC STAT. AREP PMG FUSIBLES / FUSES

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW

APPENDIX B: Generation Interconnection Application Form

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

R 450. AVRs. Installation and maintenance. This manual is to be given to. the end user R 450 VOLT. STAB. I EXC STAT. LEDS PMG

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Sizing Generators for Leading Power Factor

Short-circuit behavior - Xd ; s-s, transient, subtransient. Chapter 4 - Series Resistance of Transmission Lines

R438 A.V.R. Installation and maintenance. This manual is to be given to. the end user CALL US TODAY POWER-58. SHOP ONLINE

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

SAMSUNG ELECTRO-MECHANICS CO., LTD

PART 1 OWNER/APPLICANT INFORMATION

Conventional Paper-II-2013

K Factor Power Transformers

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

DATAMAX GENERATORS DATA C E NT E R A P P L I C AT I O N S, TO K W LOW A N D H I G H VO LTAG E, 6 0 A N D 5 0 H Z

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

Code No: R Set No. 1

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Standard & Optional Items, Certifications and RFQ

OBICON. Perfect Harmony. Short overview. ROBICON Perfect Harmony. System Overview. The Topology. The System. ProToPS. Motors.

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

1 INTRODUCTION ORDER CODE / INFORMATION

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Orbital GFI Inverter Series

Transcription:

Alternators: LSA 5, XL8 Ratings 5 Hz 5 rpm kva 66 V 4 poles kva / kwe - Cos φ =,8 3 phase Duty / Ambient Continuous duty (BR) / 4 C PR* / 4 C PR* / 7 C Temperature Rise Class.H/5 K Class.F/5 K 5 K 63 K Tension (*) 63 V - 66 V 63 V - 66 V 63 V - 66 V 63 V - 66 V kva 84 kwe 6 459 696 76 (*) Y connection * PR= Peak rating Reactances (%) - class H / 66 V - kva Short-circuit ratio Direct axis synchronous reactance Quadrature axis synchronous reactance Direct axis transient reactance Quadrature axis transient reactance Direct axis subtransient reactance Quadrature axis subtransient reactance Negative sequence reactance Zero sequence reactance Stator leakage reactance Rotor leakage reactance unsaturated saturated Kcc,53 Xd,5,887 Xq,3,3 X'd,8,94 X'q,3,3 X''d,6,7 X''q,58,34 X,4, X Xs or Xl Xr,9,63,8 Time constants ( s ) Open circuit direct axis transient time constant Open circuit quadrature axis transient time constant Short-circuit direct axis transient time constant Short circuit quadrature axis transient time constant Open circuit direct axis subtransient time constant Open circuit quadrature axis subtransient time constant Subtransient direct axis time constant Subtransient quadrature axis time constant Armature time constant T'do,88 T'qo NA T'd,9 T'q NA T''do,36 T''qo,4 T''d, T''q,8 Ta,4 Resistance Armature resistance X/R ratio Zero sequence resistance Negative sequence resistance Ra,3 X/R 9,478 R 3,67 R,84 Other data - Class H /66 V - kva no load excitation current full load excitation current full load excitation voltage Air flow Harmonic rate (**) total harmonic content line to line, at no load or with linear and balanced load. io ( A),7 ic (A) 4,7 uc (V) 5 M3/s,5 % NA Efficiencies ( % )(3 phase - Classe H - 66 V - kva) COS Ø =,8 COS Ø = 5% 5% 75% % % 5% 5% 75% % % 9,9 95,4 95,9 95,9 95,9 93,4 96, 96,8 97, 97,

Alternators: LSA 5, XL8 5 Hz 5 rpm kva 66 V 4 poles Efficiencies P.F. / P.F.,8 PF 98 PF,8 97 Efficiency - Rendement en % 96 95 94 93 9 9 9 5% 5% 75% % Load - Charge - % of rated electrical kw Transient voltage variation : 66 V - 5 Hz Transient voltage dip curve versus load impact 3% 5% Voltage dip - (% of rated voltage) % 5% % 5% PF = % PF =,8,,4,8,,6, Inrush - Appel de charge - % of rated kva Transient voltage rise curve versus load rejection % Voltage rise - (% of rated voltage) 5% % 5% PF =,8 %,,5,5,75,,5,5 kva shedding at P.F. - % of rated kva

Alternators: LSA 5, XL8 5 Hz 5 rpm kva 66 V 4 poles 3 phase short-circuit curves at no load and rated speed ( Y connection ) 4 Isc (Per unit - rms) Heat damage curve Symmetrical phase to neutral short circuit Symmetrical two phase short circuit Symmetrical three phase short circuit short circuit at generator terminals 8 6 4,,, Time (sec) Capability curve ( PQ diagram ),7 p.f.,8 p.f.,9 p.f. kwe / rated kva,944 p.f.,9 p.f.,875 p.f.,8 p.f.,7 p.f.,9,6 p.f.,8,7,6 p.f.,5 p.f.,6,5 p.f.,4 p.f.,5,4,4 p.f.,3 p.f.,3,3 p.f., p.f.,, p.f., p.f.,, p.f. - -,8 -,6 -,4 -,,,4,6,8 kvar / rated kva

SPECIALLY ADAPTED FOR GENSET APPLICATIONS The alternator is designed to be suitable for typical generator set applications,such as: backup, base production, cogeneration, marine applications, rental, telecommunications, etc. COMPLIANT WITH INTERNATIONAL STANDARDS The alternator conforms to the main international standars and regulations IEC 634, NEMA MG., ISO 853/3, CSA UL 446, UL 4B on request, marine regulations, etc. It can be integrated into a CE marked generator The alternator is designed, manufactured and marketed in an ISO 9 and ISO 4 environment. TOP OF THE RANGE ELECTRICAL PERFORMANCE - Class H insulation. - Standard 6-wire winding, /3 pitch for Low Voltage, and 5/6 pitch for Medium & High Voltage - Other voltages are possible with optional adapted windings. - High efficiency and motor starting capacity. EXCITATION AND REGULATION SYSTEM SUITED TO THE APPLICATION The alternator can be supplied with 'AREP+PMI' or PGM excitation system, according to the alternator specification. standard excitation system is AREP with R449 A.V.R. Excitation system regulator AREP+PMI PMG C.T. R76 R73 mains // mains // 3 phase sensing external Pot. R 449 std D 5 included included voltage regulation accuracy ±,5% PROTECTION SYSTEM SUITED TO THE ENVIRONMENT The alternator is IP 3 in standard. - Standard winding protection for clean environments with relative humidity 95%, including indoor marine environments. s : IP43 - IP44 : filters on air inlet and air outlet, water mist separator Winding protections for Harsh environments and relative humidity greater than 95% Space heaters. Thermal protection for winding.(pt) REINFORCED MECHANICAL STRUCTURE USING FINITE ELEMENT MODELLING -Compact and rigid assembly to better withstand genset or engine vibrations. - Steel frame. - Cast iron flanges and shields. -Twin-bearing and single-bearing versions designed to be suitable for most engines on the market. -Half-key balancing. -Regreasable bearings. ACCESSIBLE TERMINAL BOX PROPORTIONED FOR OPTIONAL EQUIPMENT - Easy access to the voltage regulator and to the connections. - Possible incorporation of accessories for parralleling, protection and measurement. Regulation options COMMON DATA insulation class winding pitch terminals drip proof altitude overspeed H /3 (n 6S) 6 IP 3 m 5 min- excitation system regulation accuracy (*) sustained short-circuit current Total harmonic (**) TGH / THC waveform : NEMA= TIF - (**) Waveform : C.E.I. = FHT - (**) (*) steady state duty. (**) total harmonic content line to line, at no load or full rated linear and balanced load. AREP+PMI ou PMG ±,5 % 3% (3 IN) : S < 3,5% < 5 < % Products and materials shown in this catalog may, at any time, be modified in order to follow the latest technological developments, improve the design or change conditions of utilization. Their description cannot, in any case, engage LEROY-SOMER liability. The values indicated are typical values.

Thermal damage curve Stator current (per rated current) 3,5,5 Negative phase sequence current (per rated current) 3 Maximum duration (seconds) Unbalanced load curve Maximum duration of fault (seconds) Stator Earth Fault Current Fault Current (A) 75 5 5 A B C C : Extensive damage B : Considerable damage A : Acceptable damage 3 4 5 6 7 8 9 Maximum duration of fault (seconds)