HIGH SPEED, HIGH RESOLUTION AND LOW COST DIGITAL RADIOGRAPHY

Similar documents
REAL-TIME X-RAY IMAGE PROCESSING; TECHNIQUES FOR SENSITIVITY

Amorphous Selenium Direct Radiography for Industrial Imaging

Digital Radiography : Flat Panel

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

Gamma Spectrometer Initial Project Proposal

Radiographic sensitivity improved by optimized high resolution X -ray detector design.

Photomultiplier Tube

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

X-ray light valve (XLV): a novel detectors technology for digital mammography*

Hardware for High Energy Applications 30 October 2009

COMPUTED TOMOGRAPHY 1

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

Real Time Linear Array Imaging. Brian Caccamise

Components of Optical Instruments

Digital Detector Array Image Quality for Various GOS Scintillators

10/26/2015. Study Harder

Film Replacement in Radiographic Weld Inspection The New ISO Standard

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

EVOLUTION OF THE CRYOGENIC EDDY CURRENT MICROPROBE

A high energy gamma camera using a multiple hole collimator

Development of Solid-State Detector for X-ray Computed Tomography

Charge-Coupled Device (CCD) Detectors pixel silicon chip electronics cryogenics

10/3/2012. Study Harder

Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT

Center for Nondestructive Evaluation 304 Wilhelm Hall Iowa State University Ames, Iowa 50010

Gamma Ray Spectroscopy with NaI(Tl) and HPGe Detectors

SYLLABUS. 1. Identification of Subject:

Optical Power Meter Basics

X-RAY COMPUTED TOMOGRAPHY

Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams

Digital Radiography for the Inspection of Small Defects

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

Electronic Instrumentation for Radiation Detection Systems

Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM

Synchrotron X-ray tomographic microscopy Theory vs. practice

Detectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014

SYLLABUS. TITLE: Equipment Operation I. DEPARTMENT: Radiologic Technology

Pinhole collimator design for nuclear survey system

Week 9: Chap.13 Other Semiconductor Material

Quality control of Gamma Camera. By Dr/ Ibrahim Elsayed Saad 242 NMT

Light Microscopy for Biomedical Research

Acquisition, Processing and Display

THE USE OF CdTe DETECTORS FOR DENTAL X-RAY SPECTROMETRY

X-ray backscattering: Variable irradiation geometry facilitates new insights

Digital Radiology with Photon Counting Detectors

Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications

OPTIMIZING SPATIAL RESOLUTION WITH THE MECHANICAL DESIGN OF AN X-RAY COMPU1ED TOMOGRAPHY SCANNER

50 MHz Voltage-to-Frequency Converter

Performance evaluation of a photon counting detector for high energy NDT applications

CR Basics and FAQ. Overview. Historical Perspective

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

Time Delay Integration (TDI), The Answer to Demands for Increasing Frame Rate/Sensitivity? Craige Palmer Assistant Sales Manager

QUANTITATIVE COMPUTERIZED LAMINOGRAPHY. Suzanne Fox Buchele and Hunter Ellinger

Charge Loss Between Contacts Of CdZnTe Pixel Detectors

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

A NEW LINEAR DETECTOR ARRAY CONCEPT FOR ACCELERATOR BASED DIGITAL RADIOGRAPHY OF THE FINAL DISPOSAL CANISTERS FOR SPENT NUCLEAR FUEL

Digital radiography: Practical advantages of Digital Radiography. Practical Advantages in image quality

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

CSPADs: how to operate them, which performance to expect and what kind of features are available

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

Use of Back Scattered Ionizing Radiation for Measurement of Thickness of the Catalytic Agent Active Material

SPECTROMETRIC CHARACTERISTIC IMPROVEMENT OF CdTe DETECTORS*

Citation X-Ray Spectrometry (2011), 40(4): 2. Right final form at

Visibility of Detail

Color X-ray photon counting image sensor

RaySafe X2. Effortless measurements of X-ray

Fundamentals of CMOS Image Sensors

A Prototype Amplifier-Discriminator Chip for the GLAST Silicon-Strip Tracker

Development of Personal Dosimeter Using Electronic Dose Conversion Method

X-ray Tube and Generator Basic principles and construction

Shad-o-Box HS Product Family

JEFFERSON COLLEGE COURSE SYLLABUS BET220 DIAGNOSTIC IMAGING. 3 Credit Hours. Prepared by: Scott Sebaugh Date: 2/20/2012

Large-Area CdTe Photon-Counting Pixel Detectors

Recommended Training Curriculum For Digital Radiography Personnel (Level II)

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

Interface Electronic Circuits

ANALYTICAL MICRO X-RAY FLUORESCENCE SPECTROMETER

RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II

TDI Imaging: An Efficient AOI and AXI Tool

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Marten Bosma 1, Alex Fauler 2, Michael Fiederle 2 en Jan Visser Nikhef, Amsterdam, The Netherlands 2. FMF, Freiburg, Germany

Properties of a Detector

Advances in High Energy X-ray Digital Detector Arrays

Unit thickness. Unit area. σ = NΔX = ΔI / I 0

Recent Development and Study of Silicon Solid State Photomultiplier (MRS Avalanche Photodetector)

Mobile digital radiography system for nondestructive testing of large diameter pipelines

Portable Wide- Angle y-ray Vision Systems

Soft X-Ray Silicon Photodiodes with 100% Quantum Efficiency

RADIOGRAPHIC EXPOSURE

A 1.3 Megapixel CMOS Imager Designed for Digital Still Cameras

Current technology in digital image production (CR/DR and other modalities) Jaroonroj Wongnil 25 Mar 2016

Designing an MR compatible Time of Flight PET Detector Floris Jansen, PhD, Chief Engineer GE Healthcare

Scintillation Counters

IQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison

Image acquisition. In both cases, the digital sensing element is one of the following: Line array Area array. Single sensor

High Energy Digital Radiography & 3D-CT for Industrial Systems

Digital Signal Processing for HPGe Detectors

Migrating from traditional to Digital Radiography in Aerospace

Introduction. Lighting

Transcription:

HIGH SPEED, HIGH RESOLUTION AND LOW COST DIGITAL RADIOGRAPHY AND COMPUTED TOMOGRAPHY SYSTEM Kasiviswanathan Rangarajan1,2 and T. Jensen 1 Department of Computer Engineering 2 Center for Nondestructive Evaluation Iowa State University Ames, IA 50011 INTRODUCTION The basic inspection techniques of X-ray digital radiography and computed tomography use some kind of X -ray detector in the form of an array or a single point. Most of the detectors available today have high performance characteristics in certain areas but not all. For example, a collimated germanium detector has good energy sensitivity and can provide high spatial resolution. But it has the disadvantages of being very slow and having to be operated at liquid nitrogen temperatures. An array detector such as an image intensifier viewed by a CCD camera has the advantage of being very fast, but it has poor dynamic range compared to a germanium detector. An X-ray detector can be operated in photon counting mode or in current mode. In photon counting mode, each incident X-ray produces many electron-hole pairs due to the photoelectric effect. This results in small current pulses or light scintillations across the detector material. The resulting current pulses are integrated using a charge sensitive preamplifier and counted. Sensitivity to variation in X-ray flux is determined by the statistical accuracy, which will depend on the total counting time and on the rate at which the pulses can be processed. Since shaping of individual pulses requires a minimum time, photon counting systems tend to be slow. To increase the speed of operation of the system, X -ray detectors can be operated in current mode. In this mode, electron-hole pairs constitute a short circuit current commensurate with the transit time of the charge carriers. The short circuit current can be measured using sensitive instrumentation which provides a measure of the incident flux. In this paper, we describe a digital radiography and computed tomography system based on a current mode X-ray detector that has high spatial resolution, large dynamic range, high speed of operation, is low in cost, compact in size and operates at room temperature. In addition, the system is adaptable to many types of detector material, including semiconductor X-ray detectors and scintillation based X-ray detectors. Results obtained from the system are presented and suggestions for future improvements are made. Review of Progress in Quantitative Nondestructive Evaluation. Vol. 14 Edited by D.O. Thompson and D.E. Chimenti, Plenum Press. New York. 1995 673

CURRENT MODE X-RAY DETECTOR DESIGN AND DEVELOPMENT Figure 1 shows the circuit diagram of the current mode X-ray detector we have designed and built. The current source in Fig. 1 represents the X-ray transducer, which could be of a variety of materials. For an X-ray detector to operate in current mode, two qualities of the detector material are of extreme importance: dark current stability and minimum afterglow. Even when no radiation source is present a small current (dark current) will be generated due to the thermal motion of electron-hole pairs in a material. For some semiconductor detectors to operate efficiently, a bias voltage must be applied across the detector material. Due to this bias and the resistivity of the detector material, an even larger current will flow in the detector. This dark current has to be extremely stable for proper operation because any changes in the dark current will be indistinguishable from changes in photon produced current. Certain excited electronic states in crystalline materials can trap charges for an extended period of time, thus resulting in photocurrent or light output from the detector for a measurable time even after a radiation source is removed. This property is referred to as afterglow. If a detector has high afterglow, the speed with which it can respond to changes in X-ray flux will be correspondingly reduced. The current measuring instrumentation shown in Fig. 1 consists of a very low noise current-to-voltage converter (Analog Devices AD515AL) followed by a differential voltage amplifier (Analog Devices instrumentation amplifier AD524C) and a low pass filter to filter out noise as well as to avoid aliasing effects during digitization. The analog output voltage from the detector is digitized using a 12-bit commercially available NO converter. This arrangement allows for the greatest flexibility in implementing the detector circuitry. The tofal scale factor of the instrumentation by which the input current signal is multiplied is 101. To achieve such a high gain in a single stage, very high value resistors would be +15V IGQ Figure 1. Circuit diagram of current mode X-ray detector. -I5V 674

required. These resistors tend to be expensive as well as noisy. Also, the dark current in a semiconductor detector with an applied bias voltage tends to be high. If a high gain is chosen so as to sense very low current values (typically in the 100 femto ampere range) the dark current also gets multiplied and the amplifier output saturates. By using two gain stages it is possible to introduce an offset voltage at the second stage if necessary to compensate for the dark current The instrumentation of Fig. 1 can sense a current signal in the range from 100 fa to 100 pa. We have used an NO converter sampling the output voltage at 50 khz. By averaging many consecutive samples, we significantly improve the signal to noise and extend the dynamic range. Greater detail on circuit design and construction can be found in Ref. [1]. As part of the research work, the semiconductor material CdZnTe[2-5] was evaluated for current mode of operation. The current source in Fig. 1 was substituted by a CdZnTe crystal with a bias voltage applied across the detector, and performance characteristics were evaluated. Figure 2a shows the dark current of CdZnTe measured over a period of 10 hours. It can be seen that the variation in the dark current is substantial. Figure 2b shows the variation in temperature adjacent to the CdZnTe crystal over the same time period. A remarkable correlation is noticed between temperature and dark current. Use of this material as a current mode X-ray detector would require stabilization of the temperature. However, other studies indicated that the afterglow for CdZnTe runs into seconds for continuous exposure to X-ray radiation. Although other investigators have used this material for applications with flash X-ray beams[2,6], the unacceptable amount of afterglow makes it infeasible to use CdZnTe in current mode with continuous exposure to radiation. a) 0.31 0.30 >- 0.29.S... ::s.& ::s 0.28 0 '"'.9 I -; I 0.26 2 0.27 0 / "- / ""-... b) a 'tj :<l U.S nl... 24.6 24.5 24.4 24.3 24.2 24.1 24.0 -I I I I lj 0.25 23.9 o 2 4 6 8 10 o 2 4 6 8 10 Time in Hours Time in Hours Figure 2. a) CdZnTe detector output vs. time. b) Detector temperature vs. time 675

After finding it infeasible to use CdZnTe in current mode of operation, attention was turned towards scintillation mode crystals such as NaI(TI)[7]. These crystals give out visible light scintillations in response to X-ray photons. To convert these light scintillations into usable current signal, a photodiode was used. Due to reasons of thermal stability and low dark current, a photodiode with an effective area of 2.4 mm x 2.4 mm (S1337-33BQ from Hamamatsu) was chosen. Since NaI crystals of 10 mm diameter were already available, a tapered light guide was used to couple the NaI crystal to the photodiode. The photodiode was connected to the instrumentation shown in Fig. 1. The entire system was electrically shielded from external noise sources. Measurement of the output over time showed good stability and far less temperature sensitivity than the CdZnTe detector. Details on the performance of this system are presented in the following section. DIGITAL RADIOGRAPHY AND COMPUTED TOMOGRAPHY RESULTS The X-ray detector described above was used in conjunction with a 320 kv generator (IRT IXRS 320/3200) to obtain digital radiographs and computed tomographs of a variety of objects. The output of the detector was digitized and 5000 samples were averaged for each data point. To achieve the scanning motion, the objects were placed on a computer controlled positioner stand located between the generator and detector. The best achievable spatial resolution from a system depends on a number of factors, such as the noise performance of the X-ray detector, the collimator size, and collimator alignment. The prototype system was evaluated using a 0.025 inch diameter collimator. Figure 3a shows a digital radiograph of a resolution gauge indicating spatial resolution of up to 2.5 lp/mm; this limit being due to the size of the collimator and mechanical alignment difficulties. Figure 3b shows a digital radiograph of a 150 micron diameter tungsten wire placed over a one inch thick titanium block. The tungsten wire can easily be seen, demonstrating the finer spatial resolution that can be achieved using the system. A measure of the contrast sensitivity ofthe prototype system is indicated in Fig. 3c which shows a digital radiograph of a 0.02 inch thick penetrameter placed over a one inch thick aluminum block. From the figure, the penetrameter can easily be seen, demonstrating a 2% contrast resolution for the prototype system. The dynamic range of the prototype system is best demonstrated by Fig. 3d which shows a digital radiograph of an aircraft turbine blade made of nickel. The thickest part of the sample is about 0.6 inch thick while the thinnest section is 0.2 inch thick. In order to get through the thick part of the sample, the X-ray intensity has to be high, which will result in saturation in the thin region for most detectors such as image intensifiers. From Fig. 3d, it can be seen that our detector does not saturate, demonstrating the wide dynamic range of the system. (Note that the images presented here are photographs from a display terminal which is limited to 256 grey levels. Much greater information is available in the collected data.) Using the prototype scan programs, an average scan time of one second per point was observed. To achieve comparable contrast sensitivity using a germanium detector requires about 15 seconds per point. It was also observed that 80 % of this average scan time is spent in moving the sample as opposed to actual data acquisition. Thus, further improvement in speed could be obtained by implementing more efficient motion control. Figure 4 shows some tomographic images of a variety of samples made of different materials and scanned under different X-ray intensities. All these images were acquired 676

a b c Figure 3. Digital radiographs of a) resolution gauge, b) 150 micron diameter tungsten wire on top of 2.5 cm thick titanium block, c) 0.02 inch thick aluminum penetrameter on one inch thick aluminum block, and d) nickel aircraft turbine blade. sn

Figure 4. Tomographic images of a) OS' xl" aluminum block containing 1mm diameter holes (the lower left hole contains a piece of iron), b) 1.25" diameter dry-pressed alumina ceramic sample showing internal fine structure, c) rock approximately one inch across containing uranium ore (white areas), and d) a vial of diameter 1" containing rock pieces. 678

using the same prototype detector system. The tomographic images were reconstructed using a filtered back-projection reconstruction algorithm[8]. These images demonstrate the versatility of the system in terms of handling samples of different materials and sizes. CONCLUSIONS AND FUTURE WORK We have developed a X-ray digital radiography and computed tomography system based on a current mode X-ray detector. This is a low cost, compact detector adaptable to a variety of inspection problems. It is especially useful for thick objects where X-ray scattering limits spatial resolution and contrast sensitivity for conventional imaging systems. Only a well collimated detector, such as ours, can minimize scattering problems. We are also using this detector as a beam stability monitor and generator diagnostic tool. The two-stage design of the amplifier allows for the best matching with a variety of X-ray transducers as well as with output digitizers. The second stage gain could be made software programmable to allow for further extension of the dynamic range. The averaging of digitizer samples is also adjustable, providing a tradeoff between speed and accuracy. Further improvements can be obtained by optimizing the coupling between scintillator and photodiode. Different scintillation materials such as CdWO 4 and CsI(Tl) will also be investigated. Finally, as we push the spatial resolution to finer values, better techniques for aligning the detector collimator with the incident X-ray beam will be required. ACKNOWLEDGMENT This material is based on work sponsored by NIST under cooperative agreement #70NANB9H0916. REFERENCES 1. Kasiviswanathan Rangarajan, M.S. Thesis, Iowa State University, (1994). 2. J.F. Butler et al., "Gamma and X-ray detectors manufactured from Cd1_xZnx Te grown by a high pressure Bridgman method", International Conference on Electronic Materials, Strasbourg, France, June 2-5, 1992. 3. J.F. Butler, F.P. Doty and C. Lingren, "Recent developments in CdZnTe gamma ray detector technology", Proceedings SPIE 1734, 131 (1992). 4. J.F. Butler, C.L. Lingren and F.P. Doty, "Cd1_xZnx Te gamma ray detectors", IEEE Transactions on Nuclear Science 39, 605 (1992). 5. J.F. Butler et al., "Progress in Cd1_xZnxTe radiation detectors", Proceedings, MRS-93 Conference, San Francisco, CA, April 12-16, 1993. 6. M. Cuzin et al., "Applications of CdTe detectors in X-ray imaging and metrology", Proceedings SPIE 2009, 192 (1993). 7. R.L Heath, R. Hofstadter and E.B. Hughes, "Inorganic Scintillators, A Review of Techniques and Applications", Nuclear Instruments and Methods 162,431, (1979). 8. Kini Vivekanand, M.S. Thesis, Iowa State University, (1994). 679