Acrowall-CP Cement-Plaster Stucco SYSTEM DESCRIPTION 1033764 Typical Details 1. ACROWALL-CP SYSTEM APPLICATION 2. ACROWALL-CP SYSTEM APPLICATION WITH EPS BOARD 3. ACROWALL-CP SYSTEM ISOMETRIC VIEW 4. SURFACE CONTROL JOINT (PLAN VIEW) 5. CLAD WINDOW JAMB (PLAN VIEW) 6. CLAD WINDOW HEAD 7. CLAD WINDOW SILL 8. PRIMED WINDOW HEAD 9. PRIMED WINDOW JAMB 10. PRIMED WINDOW SILL 11. HORIZONTAL EXPANSION JOINT AT FLOORLINE WOOD FRAME CONSTRUCTION 12. TERMINATION AT SOFFIT/GABLE END 13. DOWNSPOUT APPLICATION (PLAN VIEW) 14. PIPE PENETRATION 15. LIGHT FIXTURE 16. DRYER VENT 17. TERMINATION AT FOUNDATION 18. TERMINATION AT TOP OF DECK 19. TERMINATION AT BOTTOM OF DECK 20. METAL COPING 21. EPS SHAPE APPLICATION 22. CORNER BEAD (PLAN VIEW) 23. KICK-OUT FLASHING
ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing PERMALATH 1000 ACROPRIMER TM (OPTIONAL) 1. TYPICAL ACROWALL-CP SYSTEM APPLICATION 25 MM (1 ) TONGUE & GROOVE EPS PERMALATH 1000 ACROCRETE STUCCOBASE TM ACROPRIMER (OPTIONAL) 2. TYPICAL ACROWALL-CP SYSTEM APPLICATION ATION WITH EPS BOARD
NOTE: Framing, acceptable sheathing PERMALATH 1000 (ACROPRIMER TM OPTIONAL) OR WEEP SCREED 3. TYPICAL ACROWALL-CP SYSTEM ISOMETRIC VIEW OR AS REQUIRED BY CODE PERMALATH TM 1000 SURFACE MOUNTED CONTROL JOINT ACROCRETE STUCCOBASE TM 4. TYPICAL SURFACE CONTROL JOINT (PLAN VIEW)
ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 BOND BREAKER OR BACKER ROD AND SEALANT WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER CLAD WINDOW 5. TYPICAL CLAD WINDOW JAMB DETAIL (PLAN VIEW) A WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 ACROCRETE STUCCOBASE TM FLASHING SEALANT CLAD WINDOW 6. TYPICAL CLAD WINDOW HEAD DETAIL
NOTE: Framing, acceptable sheathing CLAD WINDOW WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER BOND BREAKER OR BACKER ROD AND SEALANT PERMALATH 1000 7. TYPICAL CLAD WINDOW SILL DETAIL OR AS REQUIRED BY CODE PERMALATH 1000 ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) SEALANT PRIMED WINDOW 8. TYPICAL PRIMED WINDOW HEAD DETAIL
ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing PERMALATH 1000 BOND BREAKER OR BACKER ROD AND SEALANT WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER OR AS REQUIRED BY CODE PRIMED WINDOW 9. TYPICAL PRIMED WINDOW JAMB DETAIL PRIMED WINDOW WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER OR AS REQUIRED BY CODE BOND BREAKER OR BACKER ROD AND SEALANT PERMALATH 1000 ACROCRETE STUCCOBASE TM 10. TYPICAL PRIMED WINDOW SILL DETAIL
NOTE: Framing, acceptable sheathing MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 DEEP V CONTROL JOINT OR BACK TO BACK WITH BACKER ROD AND SEALANT MIN. 13 MM (1/2 ) (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 11. TYPICAL HORIZONTAL EXPANSION JOINT AT FLOORLINE WOOD FRAME CONSTRUCTION BLOCKING SOFFIT TRIM FRIEZE BOARD OR AS REQUIRED BY CODE PERMALATH 1000 ACROCRETE STUCCOBASE TM 12. TYPICAL TERMINATION AT SOFFIT/GABLE END
ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing SET IN SEALANT SEALANT SLEEVE DOWNSPOUT STRAP DOWNSPOUT MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 13. TYPICAL DOWNSPOUT APPLICATION (PLAN VIEW) MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 SEALANT AT PERIMETER OF PENETRATION SEALANT ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 14. TYPICAL PIPE PENETRATION
NOTE: Framing, acceptable sheathing SET FLANGE IN SEALANT SMALL LIGHT FIXTURE MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 WIRE OPENING (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 15. TYPICAL LIGHT FIXTURE SET IN SEALANT SET FLANGE IN SEALANT DRYER VENT MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 16. TYPICAL DRYER VENT
ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing MINIMUM GRADE D BUILDING P WOVEN WIRE FABRIC OR 2.5 LB/SQ YD PERMALATH 1000APER WEEP SCREED NOTE: TERMINATE STUCCO SYSTEM 203 MM (8 ) MIN. ABOVE GRADE. 17. TYPICAL TERMINATION AT FOUNDATION TYPICAL WOOD OR AS REQUIRED BY CODE WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 ACROCRETE STUCCOBASE TM DECK FLASHING (SET IN SEALANT) JOIST SEALANT 18. TYPICAL TERMINATION AT TOP OF DECK
NOTE: Framing, acceptable sheathing JOIST FLASHING OR AS REQUIRED BY CODE PERMALATH 1000 19. TYPICAL TERMINATION AT BOTTOM OF DECK METAL COPING SEALANT ACCEPTABLE SHEATHING MIN. 50 MM (2 ) PERMALATH 1000 ACROCRETE STUCCOBASE TM 20. TYPICAL METAL COPING DETAIL
ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing MIN. 6:12 SLOPE MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) ACROCRETE BASE COAT EPS AESTHETIC BAND ACROCRETE LAMINA: ACROCRETE BASE COAT ACROCRETE REINFORCING MESH NOTE: OVERLAP ACROMESH 4 A MIN. 76 MM (3 ) ONTO ACROCRETE BASE COAT. 21. TYPICAL EPS SHAPE APPLICATION CORNER BEAD OR CORNER AID REINFORCEMENT MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD PERMALATH 1000 MIN. 50 MM (2 ) MAX. 305 MM (12 ) ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 22. TYPICAL CORNER BEAD DETAIL (PLAN VIEW)
NOTE: Framing, acceptable sheathing STEP FLASHING PERMALATH 1000 AND ACROCRETE FINISH BACKER ROD AND SEALANT MIN. 50 MM (2 ) MIN. 100 MM (4 ) NOTE: KICK-OUT FLASHING MUST BE ANGLED 100 MIN. TO ALLOW FOR PROPER DRAINAGE. SOLDERED OR SEALED WITH APPROPRIATE SEALANT. TERMINATE ACROWALL-CP SYSTEM 50 MM (2 ) MIN. ABOVE ROOF. BUILDING PAPER ROOF SHINGLES DRIP EDGE KICK-OUT FLASHING 23. TYPICAL KICK-OUT FLASHING DETAIL
NOTES
NOTES
RESIDENTIAL POLICY On one and two-family residential framed construction, BASF Wall Systems requires that the wall system selected be one that includes provisions for management of incidental moisture. The choices include water-managed EIFS, Acrowall-CP, and Acrowall-CBS. Acrowall Surfacing Systems for insulating concrete forms are also acceptable. There are no exceptions to this policy. Under no circumstances will BASF Wall Systems warrant the use of any other system on this type of construction without expressed written permission from BASF Wall Systems [Residential construction using EIFS on masonry (CMU) or poured concrete does not require the additional water management provisions described above.] Consult BASF Wall Systems Technical Services Department for specific recommendations concerning all other applications. Consult the Acrocrete web-site, www.acrocrete.com for additional information about products and systems and for updated literature. DISCLAIMER This information and all further technical advice are based on BASF s present knowledge and experience. However, BASF assumes no liability for providing such information and advice including the extent to which such information and advice may relate to existing third party intellectual property rights, especially patent rights. In particular, BASF disclaims all CONDITIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. BASF SHALL NOT BE RESPON- SIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. BASF reserves the right to make any changes according to technological progress or further developments. It is the customer s responsibility and obligation to carefully inspect and test any incoming goods. Performance of the product(s) described herein should be verified by testing and carried out only by qualified experts. It is the sole responsibility of the customer to carry out and arrange for any such testing. Reference to trade names used by other companies is neither a recommendation, nor an endorsement of any product and does not imply that similar products could not be used. BASF Wall Systems 3550 St. Johns Bluff Road South Jacksonville, FL 32224-2614 P: 800.221.9255 F: 904. 996.6300 www.acrocrete.com 2006 BASF Printed in U.S.A. 11/06