Acrowall-CP Cement-Plaster Stucco

Similar documents
Pebbletex Adhered Mat Design. Typical Details

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

Quick Reference Guide For MoistureFree Certified Inspectors and Contractors

CFDTT-01. Control Joint Study (General)

3M Air and Vapour Barrier 3015 Technical guide

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

TYPAR WEATHER PROTECTION SYSTEM TABLE OF CONTENTS. SPECIAL INSTALLATION CONSIDERATIONS Stucco** Brick** Stone Veneer** Wood Siding**

All Window Installation Instruction

Installation Instructions for Panel Siding and Soffit

ForceField Air & Water Barrier System. installation instructions

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

Eagle clad double-hung window installation instructions

DW HORIZONTAL INSTALLATION

Installation Guide for E-Series/Eagle Clad Mechanically Fastened Windows

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

Building Wrap and Flashing

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

26- H i n g e d P a t i o D o o r s - I n s w i n g

Flashing Materials. Rough Opening Preparation

PRIMED STRAND REVERSIBLE SHAKE

NEW CONSTRUCTION, REPLACEMENT AND FLUSH FIN REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

Building Wrap and Flashing

Installation Instructions for TruWood Reversible Trim

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

Installation Instructions for Old Mill Shingle and Designer Shake Lap Siding

Installation Manual for Thermo Panel

Installation Instructions

Installation Guide - Evolution Series Wood Siding

900 SERIES WALL PANELS

LP SmartSide Soffit ON SITE STORAGE PREPARATION. Application Instructions Vented and Non-Vented Smooth Finish or Cedar Texture. General Information

Integrity Polygon and Round Top Installation and Finishing Instructions

ASPHALT T E C H N O L O G I E S

Tools required by installer: Materials required by installer:

DW VERTICAL INSTALLATION

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

SERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION

Installation Instructions

400 SERIES VERTICAL INSTALLATION

Installation Recommendations for Finless Frame Doors

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS

Adorn Mortarless Stone Veneer Installation Natural Concrete Products

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS

UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER

The Beauty Of Wood. Made Better. Product Specifications LPZB0590

WALL TO FABRICATED FLOOR

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

HowtoPlans. 24'x8' Walk In Chicken Coop Plan. Designed for up to 50 chickens. .org

Before installation, check your local and state requirements for this type of install.

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

AIA Specification. Section Slate Shingles PART 1 GENERAL

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans

HowtoPlans..org. 12'x20' Garden Shed Plan

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

8 x 10 Timber-frame Garden Shed

UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS STANDARD

DETAIL CROFT FARM OUTBUILDING RESTORATION TOWNSHIP OF CHERRY HILL, NEW JERSEY

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET

3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25

The City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.

GENERAL INSTALLATION GUIDELINES

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)

GENERAL INSTALLATION GUIDELINES

HowtoPlans..org. DuraMax 8'x12 Garden Shed Plan

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nail Fin (JII025) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

How To Install Windows: Nail-Fin Application

Sections & Details VOCABULARY

TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING

Ekoroof LiteTile Dimensions

Appendix A. Additional Information ATTACHING JAMES HARDIE PRODUCTS TO INSULATED CONCRETE FORMS (ICF)

SERIES 300 SINGLE HUNG WINDOW INSTALLATION

SHEET METAL FLASHING AND TRIM Christ on the Mountain

Definitions and Design Considerations... W-CR-2

TABLE OF CONTENTS A. PBR

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023)

INSTALLATION INSTRUCTIONS DOUBLE-HUNG WINDOW WITH FINS

Slate Shingle Specifications

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

12x12 Shed Plans and Building Guide

INSTALLATION INSTRUCTIONS for Wood Patio Doors with Exterior Trim or Nailing Fin (JII026)

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

HydroGap Drainable Housewrap: Installation Instructions

8x8 Shed Plans and Building Guide

INSTALLATION MANUAL. ZIP System Roof & Wall Sheathing FASTER. TIGHTER. ENERGY EFFICIENT.

1 Exam Prep Prov Module: Exterior Finishing Questions and Answers

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

Materials. Description Quantity/Size Material Foundation Drainage material. 1.4 cu. yd. Compactible gravel

Installation Instructions

(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.

Technical Note No. 026

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016

Vinyl Windows Manufactured by VPI Quality Windows

SPRINGLOK SPRINGLOK FLASHING SYSTEM PRODUCT BROCHURE ENGINEERED PRODUCT SYSTEMS

PANELTEK ENGINEERED SIDING/PANELLING INSTRUCTIONS

Transcription:

Acrowall-CP Cement-Plaster Stucco SYSTEM DESCRIPTION 1033764 Typical Details 1. ACROWALL-CP SYSTEM APPLICATION 2. ACROWALL-CP SYSTEM APPLICATION WITH EPS BOARD 3. ACROWALL-CP SYSTEM ISOMETRIC VIEW 4. SURFACE CONTROL JOINT (PLAN VIEW) 5. CLAD WINDOW JAMB (PLAN VIEW) 6. CLAD WINDOW HEAD 7. CLAD WINDOW SILL 8. PRIMED WINDOW HEAD 9. PRIMED WINDOW JAMB 10. PRIMED WINDOW SILL 11. HORIZONTAL EXPANSION JOINT AT FLOORLINE WOOD FRAME CONSTRUCTION 12. TERMINATION AT SOFFIT/GABLE END 13. DOWNSPOUT APPLICATION (PLAN VIEW) 14. PIPE PENETRATION 15. LIGHT FIXTURE 16. DRYER VENT 17. TERMINATION AT FOUNDATION 18. TERMINATION AT TOP OF DECK 19. TERMINATION AT BOTTOM OF DECK 20. METAL COPING 21. EPS SHAPE APPLICATION 22. CORNER BEAD (PLAN VIEW) 23. KICK-OUT FLASHING

ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing PERMALATH 1000 ACROPRIMER TM (OPTIONAL) 1. TYPICAL ACROWALL-CP SYSTEM APPLICATION 25 MM (1 ) TONGUE & GROOVE EPS PERMALATH 1000 ACROCRETE STUCCOBASE TM ACROPRIMER (OPTIONAL) 2. TYPICAL ACROWALL-CP SYSTEM APPLICATION ATION WITH EPS BOARD

NOTE: Framing, acceptable sheathing PERMALATH 1000 (ACROPRIMER TM OPTIONAL) OR WEEP SCREED 3. TYPICAL ACROWALL-CP SYSTEM ISOMETRIC VIEW OR AS REQUIRED BY CODE PERMALATH TM 1000 SURFACE MOUNTED CONTROL JOINT ACROCRETE STUCCOBASE TM 4. TYPICAL SURFACE CONTROL JOINT (PLAN VIEW)

ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 BOND BREAKER OR BACKER ROD AND SEALANT WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER CLAD WINDOW 5. TYPICAL CLAD WINDOW JAMB DETAIL (PLAN VIEW) A WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 ACROCRETE STUCCOBASE TM FLASHING SEALANT CLAD WINDOW 6. TYPICAL CLAD WINDOW HEAD DETAIL

NOTE: Framing, acceptable sheathing CLAD WINDOW WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER BOND BREAKER OR BACKER ROD AND SEALANT PERMALATH 1000 7. TYPICAL CLAD WINDOW SILL DETAIL OR AS REQUIRED BY CODE PERMALATH 1000 ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) SEALANT PRIMED WINDOW 8. TYPICAL PRIMED WINDOW HEAD DETAIL

ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing PERMALATH 1000 BOND BREAKER OR BACKER ROD AND SEALANT WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER OR AS REQUIRED BY CODE PRIMED WINDOW 9. TYPICAL PRIMED WINDOW JAMB DETAIL PRIMED WINDOW WRAP OPENING WITH MINIMUM GRADE D BUILDING PAPER OR AS REQUIRED BY CODE BOND BREAKER OR BACKER ROD AND SEALANT PERMALATH 1000 ACROCRETE STUCCOBASE TM 10. TYPICAL PRIMED WINDOW SILL DETAIL

NOTE: Framing, acceptable sheathing MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 DEEP V CONTROL JOINT OR BACK TO BACK WITH BACKER ROD AND SEALANT MIN. 13 MM (1/2 ) (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 11. TYPICAL HORIZONTAL EXPANSION JOINT AT FLOORLINE WOOD FRAME CONSTRUCTION BLOCKING SOFFIT TRIM FRIEZE BOARD OR AS REQUIRED BY CODE PERMALATH 1000 ACROCRETE STUCCOBASE TM 12. TYPICAL TERMINATION AT SOFFIT/GABLE END

ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing SET IN SEALANT SEALANT SLEEVE DOWNSPOUT STRAP DOWNSPOUT MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 13. TYPICAL DOWNSPOUT APPLICATION (PLAN VIEW) MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 SEALANT AT PERIMETER OF PENETRATION SEALANT ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 14. TYPICAL PIPE PENETRATION

NOTE: Framing, acceptable sheathing SET FLANGE IN SEALANT SMALL LIGHT FIXTURE MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 WIRE OPENING (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 15. TYPICAL LIGHT FIXTURE SET IN SEALANT SET FLANGE IN SEALANT DRYER VENT MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 16. TYPICAL DRYER VENT

ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing MINIMUM GRADE D BUILDING P WOVEN WIRE FABRIC OR 2.5 LB/SQ YD PERMALATH 1000APER WEEP SCREED NOTE: TERMINATE STUCCO SYSTEM 203 MM (8 ) MIN. ABOVE GRADE. 17. TYPICAL TERMINATION AT FOUNDATION TYPICAL WOOD OR AS REQUIRED BY CODE WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 ACROCRETE STUCCOBASE TM DECK FLASHING (SET IN SEALANT) JOIST SEALANT 18. TYPICAL TERMINATION AT TOP OF DECK

NOTE: Framing, acceptable sheathing JOIST FLASHING OR AS REQUIRED BY CODE PERMALATH 1000 19. TYPICAL TERMINATION AT BOTTOM OF DECK METAL COPING SEALANT ACCEPTABLE SHEATHING MIN. 50 MM (2 ) PERMALATH 1000 ACROCRETE STUCCOBASE TM 20. TYPICAL METAL COPING DETAIL

ACROWALL-CP DETAILS NOTE: Framing, acceptable sheathing MIN. 6:12 SLOPE MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD EXPANDED METAL LATH OR PERMALATH 1000 (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) ACROCRETE BASE COAT EPS AESTHETIC BAND ACROCRETE LAMINA: ACROCRETE BASE COAT ACROCRETE REINFORCING MESH NOTE: OVERLAP ACROMESH 4 A MIN. 76 MM (3 ) ONTO ACROCRETE BASE COAT. 21. TYPICAL EPS SHAPE APPLICATION CORNER BEAD OR CORNER AID REINFORCEMENT MIN. 20 GAUGE 1 GALVANIZED STEEL WOVEN WIRE FABRIC OR 2.5 LB/SQ YD PERMALATH 1000 MIN. 50 MM (2 ) MAX. 305 MM (12 ) ACROCRETE STUCCOBASE TM (MIN. 10 MM (3/8 ) MAX. 19 MM (3/4 ) 22. TYPICAL CORNER BEAD DETAIL (PLAN VIEW)

NOTE: Framing, acceptable sheathing STEP FLASHING PERMALATH 1000 AND ACROCRETE FINISH BACKER ROD AND SEALANT MIN. 50 MM (2 ) MIN. 100 MM (4 ) NOTE: KICK-OUT FLASHING MUST BE ANGLED 100 MIN. TO ALLOW FOR PROPER DRAINAGE. SOLDERED OR SEALED WITH APPROPRIATE SEALANT. TERMINATE ACROWALL-CP SYSTEM 50 MM (2 ) MIN. ABOVE ROOF. BUILDING PAPER ROOF SHINGLES DRIP EDGE KICK-OUT FLASHING 23. TYPICAL KICK-OUT FLASHING DETAIL

NOTES

NOTES

RESIDENTIAL POLICY On one and two-family residential framed construction, BASF Wall Systems requires that the wall system selected be one that includes provisions for management of incidental moisture. The choices include water-managed EIFS, Acrowall-CP, and Acrowall-CBS. Acrowall Surfacing Systems for insulating concrete forms are also acceptable. There are no exceptions to this policy. Under no circumstances will BASF Wall Systems warrant the use of any other system on this type of construction without expressed written permission from BASF Wall Systems [Residential construction using EIFS on masonry (CMU) or poured concrete does not require the additional water management provisions described above.] Consult BASF Wall Systems Technical Services Department for specific recommendations concerning all other applications. Consult the Acrocrete web-site, www.acrocrete.com for additional information about products and systems and for updated literature. DISCLAIMER This information and all further technical advice are based on BASF s present knowledge and experience. However, BASF assumes no liability for providing such information and advice including the extent to which such information and advice may relate to existing third party intellectual property rights, especially patent rights. In particular, BASF disclaims all CONDITIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. BASF SHALL NOT BE RESPON- SIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. BASF reserves the right to make any changes according to technological progress or further developments. It is the customer s responsibility and obligation to carefully inspect and test any incoming goods. Performance of the product(s) described herein should be verified by testing and carried out only by qualified experts. It is the sole responsibility of the customer to carry out and arrange for any such testing. Reference to trade names used by other companies is neither a recommendation, nor an endorsement of any product and does not imply that similar products could not be used. BASF Wall Systems 3550 St. Johns Bluff Road South Jacksonville, FL 32224-2614 P: 800.221.9255 F: 904. 996.6300 www.acrocrete.com 2006 BASF Printed in U.S.A. 11/06