WT300 Series THE 5TH GENERATION OF THE WORLD'S BEST SELLING POWER METER

Similar documents
WT300 Series THE 5TH GENERATION OF THE WORLD'S BEST SELLING POWER METER

The world s best seller. WT300E Series Digital Power Meter. Bulletin WT300E-01EN

WT Series. Power Analyzer WT series WT500 WT3000 WT1800 WT330 WT310. Basic Accuracy: 0.2% Basic Accuracy: 0.06% Frequency range: DC, 0.

WT300 Series THE 5TH GENERATION OF THE WORLD'S BEST SELLING POWER METER. High Performance and Reliability DIGITAL POWER METER. Digital Power Meter

Digital Sampling Power Meter. Digital Power Meter and Power Analyzer WT210/WT230 WT1600 WT2010/WT2030 PZ4000

WT Series & PZ. Power Analyzer WT series & PZ WT500 WT3000 WT1800 WT230 WT210 PZ4000. Basic Accuracy: 0.2%

WT210/WT at rated. 5 ma range. input Low current (WT210) DC 0.5 Hz. to100 khz. Digital Power Meters ±0.2% WT210/WT230 Digital Power Meters

ENERGY SAVING TOOLS. Digital Sampling Power Meters with Superior Cost Performance. Digital Power Meters

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN

WT to 40 A. 15 to 1000 V 0.2% DC 0.5 Hz to 100 khz. Power Analyzer. Power Analyzer WT500

Digital Power Meter. IM E 4th Edition

APPLICATIONS. Oscilloscope Display. Harmonic Measurement. High Precision Measurement up to 0.1% Power Supplies Tests Motor Tests

High-accuracy measurement of standby to operating power

High-accuracy measurement of standby to operating power

Next generation in precision. WT5000 Precision Power Analyzers. Bulletin WT EN

APPLICATIONS. Oscilloscope Display. Harmonic Measurement. High Precision Measurement up to 0.1% Input Range 1000Vrms/50Arms

The PW3336 (2-channel) and PW3337 (3-channel) can measure DC and a variety of power connections ranging from single-phase 2-wire to 3-phase 4-wire*.

Programmable AC Power Source Model 9801

STANDBY MODE OFF MODE. POWER HiTESTER. Accurate evaluation of consumption power of electrical products. An Energy Saving Support Tool

DM-5 Power Quality Analyzer

Accurately measure devices up to 1000 V/65 A AC/DC with direct input

Wide-band Models from DC to 100 MHz

Input Elements Max. 6 Current Measurement 100 µ A to 55 A Fast data Capturing 5 ms Response *Max.1ms (When External Sync ON)

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

Effective solution for AC power calibration. LS3300 AC power calibrator. Bulletin LS EN

Wide-band Models from DC to 100 MHz

PA3000 Four-channel, Multi-phase AC/DC Power Analyzer

Explanation of options and accessories for the GP102 and GP102 -PAV

Agilent 34405A Multimeter

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES

Wide-band Models from DC to 100 MHz

3331, 3332 POWER HiTESTER

METRAClip85 and 86 Clamp Multimeters

Keysight 34401A Multimeter

METRAClip87 and 88 Clamp Multimeters

Cost-effective Digital Sampling Power Analyzer. Digital Power Meter

WT to 40 A. 15 to 1000 V 0.2% DC 0.5 Hz to 100 khz. Power Analyzer. Power Analyzer WT500

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

World-Class Accuracy & Measurement Range (40 Conventional Models)

True RMS Bench Multimeters 2831E and 5491B

PA1000 Single Phase AC/DC Power Analyzer Datasheet

PM6000. Voltech. Power Analyzer

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display

California Instruments BPS Series kva V A / Phase. Overview. High Power AC Source. Expandable Power Levels.

Agilent U2500A Series USB Simultaneous Sampling Multifunction DAQ Devices

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

True RMS Bench Multimeters 2831E and 5491B

Portable Multi-Channel Recorder Model DAS240-BAT

High-precision portable RESISTANCE METER

Burst mode - This is incorporated to simulate simultaneous analog input. Compatible with a range of Application Development Environments

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

Agilent U2300A Series USB Modular Multifunction Data-Acquisition Devices

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX

Wide Spectrum Power Meter for Comprehensive Device Assessment

Precision Power Analyzer

Manage Electrode Reaction Resistance, Electrolyte Resistance, and Welding Resistance

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection

Power Analyzer. IM E 5th Edition

DECLARATION OF CONFORMITY

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

AC Power Source/Analyzers...

LEAK CURRENT HiTESTER ST5540/ST Washington Street Melrose, MA Phone Toll Free

Fluke 3540 FC Three-Phase Power Monitor

CLAMP ON HiTESTER SERIES

Fluke Norma 4000/5000

POWER HiTESTER 3331, 3332

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Fluke 3540 FC Three-Phase Power Monitor

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

7075 WAVEFORM GENERATOR SIGNAL SOURCE

Datasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function

USER'S MANUAL DMR-6700

Network Analyzer for Low-, Medium- and High-Voltage Networks

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

True RMS Bench Multimeter 5492B

DM-III Multitest & DM-III Multitest F Power Quality Recorders

Arbiter Systems, Inc Vendels Circle, Suite 121 Paso Robles, CA USA

AC POWER SOURCES DP SERIES PROGRAMMABLE AC/DC POWER SOURCE. A powerful and reliable AC power source for customers. Options.

HP 34401A Specifications 8

Arbitrary power supplies. 160 W to 5200 W

DIGITAL HiTESTER 3237, 3238, 3239

DC MHZ PXI Differential Instrumentation Amplifier

Complimentary Reference Material

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

RS232 AC-DC VOLTAGE POWER AMPLIFIERS PCU-10K / 15K / 20K / 24K-AB/4G/HP PERFORMANCES APPLICATIONS DESCRIPTION COMMERCIAL REFERENCES

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards

DIGITAL POWER METER MODEL 66203/66204 MODEL 66203/ Digital Power Meter

Bipolar Output Working Standard

For easy-to-use loggers, look no further! WIRELESS MINI LOGGER LR8512, LR8513, LR8514, LR8515

FLEXIBLE CURRENT PROBES

EAC/AFV-P SERIES. High performance programmable AC power source 600 VA to 5 kva only in 2 U or 5 U

Handy and Easy to Use Power Management Support

HMC-T2220B. Portable & Battery Operated! Portable Synthesized Signal Generator, 10 MHz to 20 GHz. Instrumentation Product Support at

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

DM-III MULTITEST Power Quality Recorder

KMT - Kraus Messtechnik GmbH

Green LED (right of 'D' type connector)

Transcription:

Digital Power Meter WT300 Series DIGITAL POWER METER THE 5TH GENERATION OF THE WORLD'S BEST SELLING POWER METER High Performance and Reliability l Basic Accuracy of 0.% of Reading l Low Measurement down to 50 micro-amps l DC, 0.5 Hz to 00 khz Frequency Range l Standard USB, and GPIB or RS232 Interfaces

Yokogawa s new compact WT300 series for reliable power measurement The WT300 series is the 5th generation of Yokogawa s compact power meter portfolio. The world s best selling power meter is the power meter of choice in multiple industries from production lines to R&D applications. Wide current input range with high performance and reliability Wide current input ranges The WT300 series offers customers a wide range of current inputs from a few ma right up to 40Arms. It can measure both AC and DC. Ranges 5.000 to 600.00V 0.5000A to 20.000A 5.0000mA to 20.000A.0000A to 40.000A Fast display and data update rate The fast display and 00ms maximum data update rate of the WT300 series offers customers a short tact time in their testing procedures. Consistent Basic Measurement Accuracy for all input ranges. 0.% of reading + 0.% of range (50Hz/60Hz) WT30(ch) Simultaneous measurement of all parameters A WT300 series can measure all DC and AC parameters. It can also measure harmonics and perform integration simultaneously without changing the measurement mode. The WTViewerFreePlus software is used to monitor and save all these parameters. Example of WTViewerFreePlus display Convenient measurement functions - MAX hold function The maximum values of RMS/PEAK voltage & current active power, reactive power and apparent power can be held. - Line filter and frequency filter capability These filter functions will cut off unnecessary noise & harmonic components for fundamental waveform measurements. WT30HC(ch, MAX40A) PC, Data Logger and External Sensors connectivity Customers therefore have the flexibility to choose according to their application needs e.g. from production lines to engineering test benches. Customers can use WTViewerFreePlus software to set up all kinds of measurements. Additionally, the numeric values, waveform display* and trend graphs of the measurement data can be displayed and saved. The D/A option is used to output,, Power and other measured data for recording to data loggers (+/-5Vdc outputs). (WT30/WT30HC 4CH, WT332/WT333 2CH) WT332(2ch)/WT333(3ch) The WT300 series offers a wide range of communication interfaces such as USB, GP-IB or RS-232 (Selectable) and Ethernet (Optional). * Waveform display requires the /G5 Harmonic option D/A output for measurement recording Test bench Air conditioner evaluation Production line test system sensor input Customers have the option to select either 2.5V to 0V range (/EX option) or 50mV to 2V range (/EX2 option) inputs for measuring large currents using current clamps or current sensors with voltage outputs. Motor s Megawatts External input for current sensor Key Features Applications Software & Tool First in Class* and First in Industry* First in class : Auto ranging function available in selected ranges The auto-range function is used to select/change the range automatically in specific ranges. This results in shorter range changing times and thus quicker and more efficient testing. Image of Range skip (configuration) function operation Action of Yokogawa s previous model Input signal changes Range change ends Change available ranges stepwise Action of WT30/WT330 series Range change ends Change to selected next range First in industry : Integration measurement auto ranging function Conventionally, when power meters operate in an integration mode to measure power consumption and standby power, the measuring ranges need to be fixed. However, if the level of the input exceeds the maximum of the selected range, the results will be incorrect and the test will need to be repeated with higher ranges applied. The WT300 series has a high speed automatic ranging capability in integration mode which removes this need to repeat the test and integration is continuous and accurate. This function is not only available for +/- Wh but also for Ah and DC current. * According to YOKOGAWA survey by Dec, 202 02 03

WT300 power meters are easy to use, cost effective and accurate for a wide range of applications in Production, Testing, Evaluation and R&D. For Home appliances and Office equipment For Industrial equipment and Transportation Development and evaluation tool for home appliances Automotive - Battery or DC driven device evaluation - Compact half rack mount size helps customers build smaller test systems with a better Return on Investment (ROI). - D/A output function for data recording - Multiple communication interfaces. USB, RS-232 or GP-IB and Ethernet capability. - 5mA range helps small current measurement (WT30) - Auto ranging function under Integration mode - Range skip (range configuration) function provides the ability to select the usable ranges in advance. Auto ranging enables the WT300 series to rapidly adapt to changing input conditions. - Accurate DC measurement: 0.3% total (WT30HC: 0.5% total) - Direct high current measurement up to 40A without any external current sensor (WT30HC). - Charge/Discharge (+/-Wh, +/-Ah) energy measurement for batteries The range skip function reduces the range change transition period. The WT30 can measure both large and small currents accurately in a single test. This can reduce the total evaluation period or removes the need to use two rather than one power meters for the application, thereby saving capital cost. - Integration measurement for long period - D/A output function for data recording - DC, 0.5Hz to 00kHz broad bandwidth capability The WT300 series provides reliable current integration (Ah) and Energy (Wh) measurement for up to 0,000 hours (approx. year). The D/A option is used to save and monitor the measurement results (WT30/WT30HC: 4ch, WT332/WT333: 2ch). An external recorder or data logger like, a ScopeCorder, can be used to save this D/A function data along with other parameters such as temperatures, torque and rotation speed. The WT30HC can measure currents up to 40A directly. This provides a cost effective and accurate method for testing DC driven devices in vehicles without having to use extra sensors. Applications The simultaneous measurement of power consumption parameters such as U, I, P, frequency, Power Factor and Harmonics for production line or QA testing results in reduced tact times. Thus testing is faster and cheaper. The DA output and communication interfaces enable data to be remotely and flexibly captured. Duration testing and efficiency measurement for industrial motors and rotating machinery Key Features Production line or QA testing of electric Devices Navigation device Image of range configuration function for WT300 series Input signal changes Action of Yokogawa s previous model* Change available ranges stepwise Range change ends system Range change ends External input for current sensor Audio Visual device for vehicle Change to selected next range * Comparison with Yokogawa s previous model WT20/WT230 - The WT30 has a high measurement resolution of Max. 00µW under the 5mA range setting. - Simultaneous measurement of normal power parameters, harmonic components and THD. - Dynamic input capability of crest factor Max 300 (Peak value / minimum effective RMS value) - Free PCM software for IEC6230 testing Evaluation of large current equipment such as Induction Heaters/Cookers - Direct high current measurement up to 40Arms without using external current sensors (WT30HC). - Auto ranging function for Integration mode The WT30HC allows 40Arms to be directly inputted without the requirement to use current clamps or current sensors. This not only provides more precise measurement but also saves on investment costs. The wide current ranges are from A to 40A and voltage ranges are from 5 V to 600 V. Customers can use it for the evaluation of special waveform driven devices such as IH cookers and heaters. The WT30 together with the power consumption measurement (PCM) software enables users to perform standby power testing according to international standard. Evaluation testing of special waveform driven devices and distorted waveforms (including DC component) Conformance and evaluation testing of uninterruptable power supplies (UPS) - DC, 0.5Hz to 00kHz broad bandwidth capability - Average active power measurement under integration mode - Maximum order setting for THD calculations - Efficiency measurements using a single power meter - Average active power measurement under integration Mode The WT300 series has a broad frequency capability of DC and from 0.5Hz to 00kHz. It can measure the RMS value of distorted waveforms like square waveforms or special waveform driven devices. The average active power measurement function gives accurate power consumption data for fluctuating power devices such as burst waveform operated devices. Therefore the customer can perform accurate distorted waveform measurements without using special mode settings. Testing to international standards, such as IEC6230, Energy Star and SPECpower Software & Tool Motor s Megawatts Action of WT30/WT330 series range configration The WT300 series enables users to conduct conformity tests according to UPS performance testing standards. The WT300 series is used to measure and calculate input & output levels, the efficiency, frequency and THD. The average active power data also provides accurate values of power consumption. The WT300 series along with the WTViewerFreePlus software helps to simultaneously measure all the necessary parameters required to test a UPS thereby reducing the evaluation time. UPS I WTViewerFreePlus PCM software U DUT t Single Phase voltage IH Cooking Heater Please visit the URL below which shows many applications and examples. It will be regularly updated with the latest applications. 04 Burst Waveform t Square Waveform WTViewerFreePlus : PC Software http://tmi.yokogawa.com/technical-library/application-notes/ 05

Easy set up and display of Numeric data, Trend graphs and Waveforms using PC application software Support tools for creating dedicated programs! WTViewerFreePlus For WT300 Series (included) LabVIEW Drivers Programming tool samples The WTViewerFreePlus software can capture measured numeric values, harmonic values and waveform data. The data can be transferred to a PC via a USB, GP-IB/RS-232 or Ethernet communication interface, and it can be displayed* and saved on the PC. Setting Window As well as using the WT300 series front panel to setup the powermeter, you can use the software to quickly set up your favorite conditions. It also shows all the setting parameters and the status at a glance. In particular, you can set up the range-skip function (range -configuration setting) and specify the maximum order used for the THD calculation. Measurement Window The software can display items which cannot be shown on the display of the WT300 series, such as multiple numeric measurement parameters, the harmonics data of each order, bar graphs, trend graphs and voltage & current waveforms. The free software thus adds additional performance to the WT300 series. * Please check the Instruction manual in the CD for more information. Standby power measurement conforming to IEC6230 Ed2.0 Power Consumption Measurement Software (Free) * Waveform display requires /G5 Harmonic option. The Power Consumption Measurement Software together with a WT30 (or another WT series instrument) provides a trustworthy power measurement solutions for testing the standby and off mode power of household products and office equipment. The solution enables testing to be performed according to the IEC6230 Ed.0 and Ed2.0 standards which specify the use of special algorithms for determining the power stability in the device under test. The software thus gathers all the required measurement data from the WT30, which includes not only voltage/ current/ power/ frequency but also the total harmonic distortion (THD) and the crest factor (CF) of the AC power supply. We therefore also recommend that the WT30 is installed with the harmonic option (/G5) and that a low distortion power supply is used for the test. Data acquisition is possible using LabVIEW. LabVIEW drivers can be downloaded from our Web site. (Free of charge) * LabVIEW is a registered trademark of NATIONAL INSTRUMENTS Corporation in the U.S.A. DC power measurement accracy *: Simultaneous, mode independent measurement using the WTViewerFreePlus PC software. *A command compatible mode for the previous WT200 series is prepared. (IEEE488.2 only) In that mode, the WT300 series works identically to a WT200 series except for the Store (and recall operation) and the Compare functions. To help you create dedicated programs for your system, we provide sample programs which support Visual Basic/Visual C++/Visual Basic.NET and Visual C# *. The sample programs support communication via USB, GP-IB/RS-232 or Ethernet interfaces and can be downloaded from our Web site. * Visual Basic, Visual C++, Visual Basic.NET and Visual C# are registered trademarks of MICROSOFT Corporation in the U.S.A. Comparison between WT20/230 series and WT30/330 series range Direct input (Crest factor=3) External current input Effective input range for voltage & currnet (CF=3) Maximum displaying value for voltage & current (CF=3) 0<PF< Simultaneous measurement of RMS, VotageMEAN & DC Frequecy measurement Number of display item Sampling rate Harmoinc measurement THD calculation maximum order setting Auto ranging of integaration USB GP-IB Communication interface RS-232 Ethernet IEEE stanndard for GP-IB Comparetor function Viewer software (setting & data capturing) Coming soon WT30/WT332/WT333 0.% of reading+0.2% of range 5m/0m/20m/50m/00m/200m/ 0.5//2/5 /0/20[A] (WT30) 0.5//2/5/0/20[A] (WT332/WT333) EX: 2.5//5/0[V] EX2: 50m/00m/200m/500m//2[V] (OP.) % to 30% % to 40% Power reading x {power reading error + (power range / apparent power reading) + tanø x (influence when PF = 0)} % * 2 channels (voltage and current) 4 items Approximately 00 ks/s (OP, / G5) (OP, -50th) GP-IB or RS-232 GP-IB or RS-232 (OP) IEEE488.2 Free (included) WT30HC 0.3% of reading+0.2% of range /2/5/0/20/40[A] EX: 2.5//5/0[V] EX2: 50m/00m/200m/500m//2[V] (OP.) % to 00% (40A range only) % to 0% (40A range only) Power reading x {power reading error + (power range / apparent power reading) + tanø x (influence when PF = 0)} % * 2 channels (voltage and current) 4 items Approximately 00 ks/s (OP, / G5) (OP, -50th) GP-IB or RS-232 GP-IB or RS-232 (OP) IEEE488.2 Free (included) WT20/WT230 0.3% of reading+0.2% of range 5m/0m/20m/50m/00m/200m/ 0.5//2/5 /0/20[A] (WT20) 0.5//2/5/0/20[A] (WT230) EX: 2.5/5/0[V] EX2: 50m/00m/200m[V] (OP.) % to 30% % to40% Add the power reading x {tanø x (influence when PF = 0)}%. selected voltage or current (one) 3 items Approximately 50 ks/s (OP, / HRM) (OP) GP-IB or RS-232C (OP) GP-IB or RS-232C IEEE488. and IEEE488.2 Free (download) Superior points Changed points Key Features Applications Software & Tool Rear View Configuring and Establishing a New Connection between the WT30 and a PC Test Report input terminals 2 Input terminals 3 3 External current sensor input 5 4 3 4 USB communication interface 2 5 GP-IB/RS-232 (Standard) 6 Ethernet (Optional) 7 D/A output connector 7 6 2 5 4 6 7 06 07

Example of basic characteristics Error [% of range] Error [% of VA] 0% 5% 0% - 5% - 0% 0 00,000 0,000 00,000 Frequency [Hz] 0% 5% 0% - 5% Example of Frequency -power Accuracy Characteristics WT30 50V/A range WT30_Spec and reference values_upper WT30_Spec and reference value_lower WT30HC 50V/0A range WT30HC_Spec and reference values_upper WT30HC_Spec and reference values_lower Example of frequency versus power accuracy characteristic (power specification for cosø=0) WT30 50V/A range WT30HC 50V/0A range Spec and reference values_upper Spec and reference values_lower - 0% 0 00,000 0,000 00,000 Frequency [Hz] 79 Input Input terminal type Input format Measurement range 250 23 88 9 73 23 359 356 Error [% of range] Error [% of range].00% 0.0% Total power Error with rated range input for an arbirtary power factor (f=50/60hz) 0.0% 0.00 0.00 0.00.000 Power Factor 5% 4% 3% 2% % Exterior View WT30 series Unit : mm s Plug-in terminal (safety terminal)) Floating input through resistive voltage divider Floating input through shunt 3 Effect of common mode voltage on reading value (Common 600Vrms) WT30 5V range WT30 0.5A range Spec and reference values 0% 0 00,000 0,000 00,000 Frequency [Hz] Input impedance 23 32 20 * Performance of WT332/WT333 is same as that of WT30 23 327 34 28.5 WT330 series Unit : mm with the resistance, + 0 m with the resistance with the resistance ( period, for 20 ms) (for s) terminals shorted. ranges of WT30/WT332/WT333, A, 2 A, 5 A, 0 A, 20 A, 40A ranges of { 0.00 f% of range} current input of WT30/WT332/WT333 and 40 A for the current input terminal of { 0.0002 f% of range} { 0.0 f% of range} and Accuracy s After warm-up time has passed Accuracy (at 2 months) WT30,WT330 WT30HC WT30HC sensor input) +0.2% of range) +0.2% of range) +0.2% of range) +0.2% of range) +0.2% of range) +0.2% of range) f +0. % of range) +0. % of range) +0. % of range) +0.2 % of range) +0.2 % of range) +0.2 % of range) +0.3 % of range} +0.3 % of range} +0.3 % of range) +0.5 % of range) (5/range) % of range (0.005/range) % of range (0.5/range) % of range (/range) % of range (2.5/range) % of range (0.05/range) % of range Add 0.000000 U 2 % of reading to the AC voltage accuracies. Add 0.000000 U 2 % of reading + 0.000000 U 2 voltage reading (V). even if voltage input decreases. Add 0.0003 I 2 % of reading to the AC current accuracies. Add 0.0003 I 2 % of reading + 0.004 I 2 ma (0.5A/A/2A/5A/0A/20A range) or 0.0003 I 2 % of reading + 0.00004 I 2 I is the current reading (A). 2 % of reading to the AC current accuracies. 2 % of reading + 0.00 I 2 Add 0.0003 I 2 % of reading to the AC current accuracies. Add 0.0003 I 2 % of reading + 0.002 I 2 even if current input decreases. reference values. Input range to 30% with respect to the rated range of voltage or current. (It displays up to40%) rated range.) f f f f f f Accuracy when the Active Power Accuracy s Same as the conditions for voltage and current. Accuracy (at 2 months) WT30, WT332, WT333, WT30HC f Key Features Applications Software & Tool 08 09

Key Features Applications Software & Tool 0

g Rack Mount Model/parts number Product Description 75533-E2 For WT30 series EIA standalone installation 75533-J2 For WT30 series JIS standalone installation 75534-E2 For WT30 series EIA connected installation 75534-J2 75533-E3 75533-J3 75534-E3 75534-J3 For WT30 series JIS connected installation For WT330 series EIA standalone installation For WT330 series JIS standalone installation For WT330 series EIA connected installation For WT330 series JIS connected installation Ask Yokogawa for information on rack mounts in which WT30 and WT330 str combined. g Accessory (sold separately) General s s Warm-up time Approx. 30 minutes Operating environment Temperature: 5 C to 40 C Humidity: 20%RH to 80%RH ( condensation) Elevation: 2000m or less Installation location Indoors Storage environment Temperature: 25 C to 60 C Humidity: 20%RH to 80%RH ( condensation) Rated supply voltage 00 VAC to 240 VAC Permitted supply 90 VAC to 264 VAC range voltage Rated supply frequency 50/60 Hz Permitted supply voltage 48 Hz to 63 Hz frequency range Maximum power WT30, WT30HC: 50VA, WT332/WT333: 70VA Consumption External dimensions WT30, WT30HC: Approx. 23 (W) 88 (H) 379 (D) mm (excluding protrusions.) WT332/WT333: Approx. 23 (W) 32 (H) 379 (D) mm Weight WT30, WT30HC: Approx. 3 kg WT332/WT333: Approx. 5 kg Battery backup Setup parameters are backed up with a lithium battery. Model/parts number Product Description Order Q ty 75897 Test lead set A set of 0.8 m long, red and black test leads 758922 Small alligator-clip Rated at 300 V and used in a pair 758929 Large alligator-clip Rated at 000 V and used in a pair 758923 Safety terminal adapter (spring-hold type) Two adapters to a set 75893 Safety terminal adapter (screw-fastened type) Two adapters to a set.5 mm hex Wrench is attached 758924 Conversion adapter BNC-banana-jack (female) adapter 366924 * BNC-BNC cable m 366925 * BNC-BNC cable 2 m 75892 Fork terminal adapter Banana-fork adapter, Two adapters to a set B9284LK External sensor cable sensor input connector, Length 0.5 m 705926 Connection Cable m, For DA4, DA2 option Due to the nature of this product, it is possible to touch its metal parts. Therefore, there is a risk of electric shock, so the product must be used with caution. * Use these products with low-voltage circuits (42 V or less). g AC/DC sensor /Clamp on Probe Model Product Name Description CT000 AC/DC sensor DC~300 khz, ±(0.05% of reading +30uA), 000 Apk CT200 AC/DC sensor DC~500 khz, ±(0.05% of reading +30uA), 200 Apk CT60 AC/DC sensor DC~800 khz, ±(0.05% of reading +30uA), 60 Apk 75552 Clamp-on probe 30 Hz~5 khz, 400 Apeak(000 Arms) 96030 Clamp-on probe 20 Hz~20 khz, ±0.5% reading, 200 Arms 75574 AC/DC sensor DC~00 khz, 600 Apeak(400 Arms) * CT series do not conform CE Marking. * For detailed information, see Power Meter Accessory Catalog Bulletin CT000-00E Order Q ty g Model and Suffix Codes Model SuppixCode Description WT30 Input element model Power Cord -D UL, CSA standard, PSE -F VDE standard -R AS standard -Q BS standard -H GB standard -N NBR standard ( for Brazil ) Communication Interface -C GP- IB *USB is standard -C2 RS- 232 Optional function /C7 Ethernet interface /EX External sensor input 2.5V/5V/0V /EX2 External sensor input 50mV/00mV/200mV/500mV/V/2V /G5 Harmonics Measurement /DA4 D/A- output(4ch) Model Suppix-Code Describe WT30HC Input element /High current model Power Cord -D UL, CSA standard, PSE -F VDE standard -R AS standard -Q BS standard -H GB standard -N NBR standard ( for Brazil ) Communication Interface -C GP- IB *USB is standard -C2 RS- 232 Optional function /C7 Ethernet interface /EX External sensor input 2.5V/5V/0V /EX2 External sensor input 50mV/00mV/200mV/500mV/V/2V /G5 Harmonics Measurement /DA4 D/A- output(4ch) Model Suppix-Code Describe WT332 2 Input elements model WT333 3 Input elements model Power Cord -D UL, CSA standard, PSE -F VDE standard -R AS standard -Q BS standard -H GB standard -N NBR standard ( for Brazil ) Communication Interface -C GP- IB *USB is standard -C2 RS- 232 Optional function /C7 Ethernet interface /EX External sensor input 2.5V/5V/0V /EX2 External sensor input 50mV/00mV/200mV/500mV/V/2V /G5 Harmonics Measurement /DA2 D/A- output(2ch) Standard accessories Power cord(set), Rubber foot(set), input protective cover(each set), Start up guide(set), Connector (provided only with /DA4 or /DA2, each set), Safety terminal adapter 75893(provided two adapters in a set times input element number), CD (piece,included the startup guide, user guide, instruction manual and the communication manual by PDF data, and Viewer Software) 75897 Test lead set Two leads in a set. Use 75897 in combination with 758922 or 758929. Total length: 75 cm Rating: 000 V, 32 A 75893 * Safety terminal adapter set Screw-fastened adapters. Two adapters in a set..5 mm Allen wrench included for tightening. 758922 Small alligator adapters For connection to measurement leads (75897). Two in a set. Rating: 300 V B9284LK * 2 External Sensor Cable For connection the external input of the WT500 to current sensor. Length: 50 cm 758929 Large alligator adapters For connection to measurement leads (75897). Two in a set. Rating: 000 V 709526 26-pin cable for options DA4 and DA2 758923 * Safety terminal adapter set (spring-hold type) Two adapters in a set. Due to the nature of this product, it is possible to touch its metal parts. Therefore, there is a risk of electric shock, so the product must be used with caution. * Maximum diameters of cables that can be connected to the adapters 758923 core diameter: 2.5 mm or less; sheath diameter: 4.8 mm or less 75893 core diameter:.8 mm or less; sheath diameter: 3.9 mm or less *2 The coax cable is simply cut on the current sensor side. Preparation by the user is required. Sensorik Messtechnik A-800 Graz, Riesstraße 46 Tel.: +43 36 40 28 05, Fax: 40 25 06 Handelsgesellschaft m.b.h. Subject to change without notice. [Ed : 0/b] Printed in Japan, 30(KP) All Rights Reserved, Copyright 203, Yokogawa Meters & Instruments Corporation.