Standard Recovery Diodes, (Stud Version), 300 A

Similar documents
Standard Recovery Diodes (Stud Version), 12 A

Standard Recovery Diodes (Stud Version), 400 A

Standard Recovery Diodes, (Stud Version), 200 A

Standard Recovery Diodes (Stud Version), 150 A

Standard Recovery Diodes, (Stud Version), 400 A

VS-85HF(R), VS-86HF(R), VS-87HF(R), VS-88HF(R) Series Standard Recovery Diodes, (Stud Version), 85 A

Standard Recovery Diodes (Stud Version), 300 A

Standard Recovery Diodes, Generation 2 DO-5 (DO-203AB) (Stud Version), 80 A

Standard Recovery Diodes, Generation 2 DO-5 (Stud Version), 80 A

Standard Recovery Diodes, (Stud Version), 85 A

Standard Recovery Diodes Generation 2 DO-5 (DO-203AB) (Stud Version), 95 A

Standard Recovery Diodes (Stud Version), 150 A

Standard Recovery Diodes (Stud Version), 70 A

Standard Recovery Diodes, (Stud Version), 40 A

Power Rectifier Diodes (T-Modules), 2200 V, 20 A

Standard Recovery Diodes, (Hockey PUK Version), 800 A

VS-1N1183, VS-1N3765, VS-1N1183A, VS-1N2128A Series Power Silicon Rectifier Diodes, (Stud Version), 35 A, 40 A, 60 A

Fast Recovery Diodes (Stud Version), 40 A, 70 A, 85 A

VS-1N1183, VS-1N3765, VS-1N1183A, VS-1N2128A Series Power Silicon Rectifier Diodes, (Stud Version), 35 A, 40 A, 60 A

Standard Diodes (Super MAGN-A-PAK Power Modules), 600 A

VS-T40HF..., VS-T70HF..., VS-T85HF..., VS-T110HF... Series Power Rectifiers Diodes (T-Modules), 40 A to 110 A

Standard Recovery Diodes, 400 A

Standard Recovery Diodes (Stud Version), 150 A

Fast Recovery Diodes (Stud Version), 6 A, 12 A, 16 A

Standard Recovery Diodes (Stud Version), 150 A

Phase Control Thyristors (Stud Version), 110 A

Standard Recovery Diodes, (Hockey PUK Version), 2100 A

Medium Power Silicon Rectifier Diodes, (Stud Version), 12 A

Standard Recovery Diodes, (Hockey PUK Version), 3000 A

Standard Recovery Diodes, (Stud Version), 85 A

Three phase bridge. (Power Module), 200 A

Single phase bridge. (Power Modules), 25 A / 35 A

Single phase bridge. (Power Modules), 25 A, 35 A

Fast Recovery Diodes (Stud Version), 6 A, 12 A, 16 A

Single phase bridge. (Power Modules), 25 A/35 A

Power Modules, Passivated Assembled Circuit Elements, 40 A

VS-VSKD91.., VS-VSKC91.., VS-VSKJ91.., VS-VSKE91.. ADD-A-PAK Gen 7 Power Modules Standard Diodes, 100 A

Inverter Grade Thyristors (Stud Version), 85 A

301U(R) SERIES 300A. Stud Version STANDARD RECOVERY DIODES. Features. Typical Applications. Major Ratings and Characteristics

Phase Control Thyristors (Stud Version), 300 A

Phase Control Thyristors (Stud Version), 330 A

Power Modules, Passivated Assembled Circuit Elements, 25 A

Single Phase Bridge Rectifier, 2 A

Three Phase Bridge (Power Modules), 25 A to 35 A

Three Phase Bridge (Power Modules), 25 A to 35 A

Medium Power Phase Control Thyristors (Stud Version), 16 A

Standard Recovery Diodes, (Hockey PUK Version), 3800 A

Medium Power Phase Control Thyristors (Stud Version), 50 A

High Voltage, Input Rectifier Diode, 20 A

Single Phase Rectifier Bridge, 1.9 A

Single Phase Rectifier Bridge, 1.2 A

Three Phase Bridge, 160 A (Power Modules)

Three Phase Bridge, 300 A (Power Modules)

Thyristor / Diode (Super MAGN-A-PAK Power Modules), 570 A

Power Rectifier Diodes (T-Modules), 40 A to 110 A

Fast Recovery Diodes (Hockey PUK Version), 920 A, 1050 A

VS-VSKD91.., VS-VSKC91.., VS-VSKJ91.., VS-VSKE91.. Series ADD-A-PAK Generation VII Power Modules Standard Diodes, 100 A

Phase Control Thyristors (Stud Version), 110 A

Three Phase Bridge, 130 A to 160 A (Power Modules)

Medium Power Phase Control Thyristors (Stud Version), 50 A

Input Rectifier Diode, 80 A

Insulated Single Phase Hyperfast Bridge (Power Modules), 60 A

HEXFRED Ultrafast Diodes, 100 A (INT-A-PAK Power Modules)

High Voltage, Input Rectifier Diode, 10 A

Inverter Grade Thyristors (Stud Version), 300 A

Input Rectifier Diode, 60 A

High Performance Schottky Rectifier, 240 A

Phase Control Thyristor RMS SCRs, 25 A, 35 A

High Voltage Surface Mountable Input Rectifier Diode, 8 A

Three Phase Bridge (Power Modules), 25/35 A

Single Phase Rectifier Bridge, 3 A, 6 A

HEXFRED Ultrafast Diodes, 300 A (INT-A-PAK Power Modules)

Surface Mount Fast Soft Recovery Rectifier Diode, 10 A

Phase Control Thyristors (Hockey PUK Version), 1745 A

Single Phase Bridge (Power Modules), 25/35 A

HEXFRED Ultrafast Diodes, 300 A (INT-A-PAK Power Modules)

FRED Pt Gen 4 Single Ultrafast Diode, 500 A (INT-A-PAK Power Modules)

VS-70TPS12PbF, VS-70TPS16PbF High Voltage Series Thyristor High Voltage, Phase Control SCR, 70 A

High Performance Schottky Rectifier, 100 A

Single Phase Rectifier Bridge, 2 A

Thyristor/Thyristor, 150 A (INT-A-PAK Power Module)

Ultrafast Soft Recovery Diode, 150 A FRED Pt

Phase Control Thyristors (Hockey-PUK Version), 2310 A

Phase Control Thyristors (Hockey PUK Version), 1350 A

Three Phase Bridge (Power Modules), 25/35 A

Single Phase Rectifier Bridge, 1.2 A

HEXFRED Ultrafast Soft Recovery Diode, 275 A

Three Phase Bridge (Power Module), 45 A to 100 A

Thyristor/Thyristor (MAGN-A-PAK Power Modules), 320 A

High Performance Schottky Rectifier, 100 A

Ultrafast Soft Recovery Diode, 150 A FRED Pt

High Performance Schottky Rectifier, 400 A

Input Rectifier Diode, 10 A

70HF(R) SERIES 70 A. Stud Version STANDARD RECOVERY DIODES. Features. Typical Applications. Major Ratings and Characteristics

AAP Gen 7 (TO-240AA) Power Modules Thyristor/Thyristor, 105 A

High Performance Schottky Rectifier, 1 A

Single Phase Rectifier Bridge, 1.9 A

Insulated Gen 2 Schottky Rectifier Module, 300 A

Fast Recovery Diodes (Hockey PUK Version), 375 A

Fast Soft Recovery Rectifier Diode, 60 A

Transcription:

Standard Recovery Diodes, (Stud Version), 300 A DO-9 (DO-205AB) PRIMARY CHARACTERISTICS I F(AV) 300 A Package DO-9 (DO-205AB) Circuit configuration Single FEATURES Wide current range High voltage rating up to 2500 V High surge current capabilities Stud cathode and stud anode version High resistance to acceleration Designed and qualified for industrial level Material categorization: for definitions of compliance please see /doc?99912 TYPICAL APPLICATIONS Converters Power supplies Machine tool controls High power drives Medium traction applications MAJOR RATINGS AND CHARACTERISTICS 301U(R) PARAMETER TEST CONDITIONS UNITS 160 TO 200 250 330 300 A I F(AV) T C 120 120 C I F(RMS) 520 470 A 50 Hz 8250 6050 I FSM A 60 Hz 8640 6335 I 2 t 50 Hz 340 183 60 Hz 311 167 ka 2 s V RRM Range 1600 to 2000 2500 V T J -40 to +180-40 to +180 C ELECTRICAL SPECIFICATIONS VOLTAGE RATINGS TYPE NUMBER VOLTAGE CODE V RRM, MAXIMUM REPETITIVE PEAK REVERSE VOLTAGE V V RSM, MAXIMUM NON-REPETITIVE PEAK REVERSE VOLTAGE V I RRM MAXIMUM AT T J = T J MAXIMUM ma VS-301U(R) VS-303U(R) VS-305U(R) VS-307U(R) VS-309U(R) 160 1600 1700 200 2000 2 250 2500 2600 15 Revision: 11-Jan-18 1 Document Number: 93509 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?90

FORWARD CONDUCTION PARAMETER SYMBOL TEST CONDITIONS 301U(R) 160 TO 200 250 UNITS Maximum average forward current 330 300 A I at case temperature F(AV) 180 conduction, half sine wave 120 120 C Maximum RMS forward current I F(RMS) DC at T C = 115 C (up to 2000 V), T C = 102 C (2500 V) 520 470 A t = 10 ms No voltage 8250 6050 Maximum peak, one cycle forward, t = 8.3 ms reapplied 8640 6335 I non-repetitive surge current FSM t = 10 ms % V RRM 6940 5090 A t = 8.3 ms reapplied Sinusoidal half wave, 7270 5330 t = 10 ms No voltage initial T J = T J maximum 340 183 Maximum I 2 t for fusing I 2 t t = 8.3 ms reapplied 311 167 t = 10 ms % V RRM 241 129 ka 2 s t = 8.3 ms reapplied 220 118 Maximum I 2 t for fusing I 2 t t = 0.1 to 10 ms, no voltage reapplied 3400 1830 ka 2 s Low level value of threshold voltage V F(TO)1 (16.7 % x x I F(AV) < I < x I F(AV) ), T J = T J maximum 0.77 0.90 High level value of threshold voltage V F(TO)2 (I > x I F(AV) ), T J = T J maximum 0.84 0.97 V Low level value of forward slope resistance r f1 (16.7 % x x I F(AV) < I < x I F(AV) ), T J = T J maximum 0.49 0.59 High level value of forward slope resistance r f2 (I > x I F(AV) ), T J = T J maximum 0.49 0.55 m I Maximum forward voltage drop V pk = 942 A, T J = T J maximum, t p = 10 ms sinusoidal FM wave 1.22 1.46 V SPECIAL SELECTION FORWARD VOLTAGE (T j = 25 C) DEVICE CLASSIFICATION BAND MIN. UNIT TEST CONDITIONS VS-305U250P4 VS-307UA250P4 VS-305UR250P4 VS-307URA250P4 P4 1.31 1.40 V 0 A pk THERMAL AND MECHANICAL SPECIFICATIONS PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS Maximum junction operating temperature range T J -40 to 180 Maximum storage temperature range T Stg -40 to 200 C Maximum thermal resistance, junction to case R thjc DC operation 0.14 Maximum thermal resistance, case to heatsink R thcs Mounting surface, smooth, flat and greased 0.08 K/W Maximum allowed mounting torque Not lubricated threads 37 +0-20 % Lubricated threads 28 N m 301U 250 ± 5 303U 152 ± 5 Weight 305U 177 ± 5 g 307U 197 ± 5 309U 160 ± 5 Case style See dimensions - link at the end of datasheet DO-9 (DO-205AB) Revision: 11-Jan-18 2 Document Number: 93509 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?90

R thjc CONDUCTION SINUSOIDAL CONDUCTION RECTANGULAR CONDUCTION CONDUCTION ANGLE TEST CONDITIONS UNITS 80 TO 200 250 80 TO 200 250 180 0.015 0.015 0.011 0.011 120 0.018 0.018 0.019 0.019 0.023 0.023 0.025 0.025 0.034 0.034 0.035 0.035 30 0.056 0.056 0.057 0.057 T J = T J maximum Note The table above shows the increment of thermal resistance R thjc when devices operate at different conduction angles than DC K/W Maximum Allowable Case Temperature ( C) 180 301U(R) Series(1600V to 2000V) 170 R thjc (DC) = 0.14 K/W 160 Conduction Angle 140 130 120 30 180 120 110 0 50 200 250 300 350 Maximum Allowable Case Temperature ( C) 180 170 R thjc (DC) = 0.14 K/W 160 Conduction Angle 140 30 130 120 120 180 110 0 50 200 250 300 350 Average Forward Current (A) Average Forward Current (A) Fig. 1 - Current Ratings Characteristics Fig. 2 - Current Ratings Characteristics Maximum Allowable Case Temperature ( C) 180 170 160 140 301U(R) Series(1600V to 2000V) R thjc (DC) = 0.14 K/ W Conduction Period 130 30 120 110 120 180 DC 0 200 300 400 500 600 Maximum Allowable Case Temperature ( C) 180 170 160 140 130 R thjc (DC) = 0.14 K/ W Conduction Period 120 30 110 120 180 DC 90 0 200 300 400 500 Average Forward Current (A) Average Forward Current (A) Fig. 1 - Current Ratings Characteristics Fig. 3 - Current Ratings Characteristics Revision: 11-Jan-18 3 Document Number: 93509 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?90

Maximum Average Forward Power Loss (W) 400 350 300 250 200 180 120 30 RMS Limit Conduction Angle R = 0.1K/W - Delta R 301U(R) Series 50 (1600V to 2000V) T J = 180 C 0 0 50 200 250 300 350 20 40 60 80 120 140 160 180 Average Forward Current (A) Maximum Allowable Ambient Temperature ( C) 0.2 K/ W 0.3 K/W 0.7 K/ W 1.5 K/W 3 K/ W thsa Fig. 4 - Forward Power Loss Characteristics Maximum Average Forward Power Loss (W) 550 500 DC 180 450 120 400 350 30 300 250 RMS Limit 200 Conduction Period 301U(R) Series (1600V to 2000V) 50 T J = 180 C 0 0 200 300 400 500 600 20 40 60 80 120 140 160 180 Average Forward Current (A) Maximum Allowable Ambient Temperature ( C) R = 0.1 K/ W - Delta R thsa 0.2 K/W 0.3 K/ W 0.7 K/W 1.5 K/W 3 K/W Fig. 5 - Forward Power Loss Characteristics Maximum Average Forward Power Loss (W) 450 400 350 300 250 200 180 120 30 RMS Limit R = 0.1 K/ W - Delta R Conduction Angle 50 T J = 180 C 0 0 50 200 250 300 20 40 60 80 120 140 160 180 Average Forward Current (A) Maximum Allowable Ambient Temperature ( C) 0.2 K/ W 0.3 K/W 0.7 K/W 1.5 K/W 3 K/ W thsa Fig. 6 - Forward Power Loss Characteristics Revision: 11-Jan-18 4 Document Number: 93509 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?90

Maximum Average Forward Power Loss (W) 600 500 400 300 200 DC 180 120 30 RMS Lim it Conduction Period T J = 180 C R = 0.1 K/ W - Delta R 0 0 200 300 400 500 20 40 60 80 120 140 160 180 Average Forward Current (A) Maximum Allowable Ambient Temperature ( C) thsa 0.2 K/ W 0.3 K/ W 0.7 K/W 1.5 K/W 3 K/W Fig. 7 - Forward Power Loss Characteristics Peak Half Sine Wave Forward Current (A) 8000 7000 6000 5000 4000 3000 At Any Rated Load Condition And With Rated V RRM Applied Following Surge. Initial T J= 180 C @ 60 Hz 0.0083 s @ 50 Hz 0.0 s 301U(R) Series (1600V to 2000V) 2000 1 10 Peak Half Sine Wave Forward Current (A) 6000 5500 5000 4500 4000 3500 3000 2500 2000 At Any Rated Load Condition And With Rated V RRM Applied Following Surge. Initial T J= 180 C @ 60 Hz 0.0083 s @ 50 Hz 0.0 s 0 1 10 Number Of Equal Amplitude Half Cycle Current Pulses (N) Number Of Equal Amplitude Half Cycle Current Pulses (N) Fig. 8 - Maximum Non-Repetitive Surge Current Fig. 10 - Maximum Non-Repetitive Surge Current Peak Half Sine Wave Forward Current (A) 9000 8000 7000 6000 5000 4000 3000 2000 Maximum Non Repetitive Surge Current Versus Pulse Train Duration. Initial T J= 180 C No Voltage Reapplied Rated V RRM Reapplied 301U(R) Series (1600V to 2000V) 0 0.01 0.1 1 Pulse Train Duration (s) Pea k Ha lf Sine Wave Forward Current (A) 6000 5000 Maximum Non Repetitive Surge Current Versus Pulse Train Duration. Initial T J= 180 C No Voltage Reapplied Rated V RRM Reapplied 4000 3000 2000 0 0.01 0.1 1 Pulse Train Duration (s) Fig. 9 - Maximum Non-Repetitive Surge Current Fig. 11 - Maximum Non-Repetitive Surge Current Revision: 11-Jan-18 5 Document Number: 93509 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?90

00 00 Instantaneous Forward Current (A) 0 T = 25 C J T = 180 C J 301U(R) Series (1600V to 2000V) 10 0 0.5 1 1.5 2 2.5 3 Instantaneous Forward Current (A) 0 T = 25 C J T = 180 C J 10 0 0.5 1 1.5 2 2.5 3 3.5 Instantaneous Forward Voltage (V) Instantaneous Forward Voltage (V) Fig. 12 - Forward Voltage Drop Characteristics Fig. 13 - Forward Voltage Drop Characteristics Transient Thermal Impedance Z (K/ W) thjc 1 0.1 0.01 Steady State Value: R thjc = 0.14 K/ W (DC Operation) 301U(R) Series 0.001 0.001 0.01 0.1 1 10 Square Wave Pulse Duration (s) Fig. 14 - Thermal Impedance Z thjc Characteristic Revision: 11-Jan-18 6 Document Number: 93509 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?90

ORDERING INFORMATION TABLE Device code VS- 30 1 U A 250 P4 1 2 3 4 5 6 7 1 - product 2-30 = essential part number 3-1 = standard device 3 = top threaded version 5 = type for rotating application with top threaded version 3/8 16UNC-2A 7 = type for rotating application with flexible lead 9 = type for rotating application with top threaded version 3/8 24UNF 4 - U = stud normal polarity (cathode to stud) UR = stud reverse polarity (anode to stud) 5 - A = maximum leakage selection I RRM = 2 ma, T J = 25 C 6 - Voltage code x 10 = V RRM (see Voltage Ratings table) 7 - Refer special selection table for applicable parts Dimensions LINKS TO RELATED DOCUMENTS /doc?95337 Revision: 11-Jan-18 7 Document Number: 93509 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?90

DO-205AB (DO-9), B-60, B-61, B-41, B-40 for 301U(R), 307U(R), 305U(R) and 309U(R) Series DIMENSIONS FOR 301U(R) SERIES - DO-205AB (DO-9) in millimeters (inches) Outline Dimensions Ceramic housing 19 (0.75) 24 (0.94) Ø 8.7 (0.34) 140 (5.51) 146 (5.75) 28 (1.10) 21(0.83) 3/4"-16UNF-2A for metric device: M16 x 1.5 contact factory 32 (1.26) 3.9 (0.15) Document Number: 95337 For technical questions, contact: indmodules@vishay.com Revision: 22-Jul-08 1

Outline Dimensions DO-205AB (DO-9), B-60, B-61, B-41, B-40 for 301U(R), 307U(R), 305U(R) and 309U(R) Series DIMENSIONS FOR 307U(R) SERIES - B-60 in millimeters (inches) Ceramic housing 19 (0.75) 11 (0.43) NOM. 12 (0.47) MIN. Ø 8.5 (0.33) 140 (5.51) 148 (5.83) 54 (2.13) 21 (0.83) 3/4"-16UNF-2A 32 (1.26) 3.9 (0.15) For technical questions, contact: indmodules@vishay.com Document Number: 95337 2 Revision: 22-Jul-08

DO-205AB (DO-9), B-60, B-61, B-41, B-40 for 301U(R), 307U(R), 305U(R) and 309U(R) Series Outline Dimensions DIMENSIONS FOR 305U(R) SERIES - B-61 in millimeters (inches) Ceramic housing 3/8"-16UNC-2A 6.4 (0.25) 98 (3.86) 59 (2.32) 7 (0.28) 21 (0.83) 3/4"-16UNF-2A 32 (1.26) 16 (0.63) DIMENSIONS FOR 309U(R) SERIES - B-41 in millimeters (inches) Ceramic housing 3/8"-24UNF-2A 7.6 (0.3) 97 (3.82) 60 (2.36) 7 (0.28) 21 (0.83) 3/4"-16UNF-2A 32 (1.26) 17.5 (0.69) Document Number: 95337 For technical questions, contact: indmodules@vishay.com Revision: 22-Jul-08 3

Outline Dimensions DO-205AB (DO-9), B-60, B-61, B-41, B-40 for 301U(R), 307U(R), 305U(R) and 309U(R) Series DIMENSIONS FOR 303U(R) SERIES - B-40 in millimeters (inches) Ceramic housing 3/8"-24UNF-2A 16.5 (0.65) 59.7 (2.35) 29 (1.14) Ø 27.3 (1.07) 9 (0.35) 21 (0.83) 3/4"-16UNF-2A 32 (1.26) 17.5 (0.69) For technical questions, contact: indmodules@vishay.com Document Number: 95337 4 Revision: 22-Jul-08

Legal Disclaimer Notice Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, Vishay ), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer s technical experts. Product specifications do not expand or otherwise modify Vishay s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. 2017 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED Revision: 08-Feb-17 1 Document Number: 90