RENDER TIMBER FRAMING WALL UNDERLAY CONTINUOUS AROUND CORNERS, POLYPROPYLENE TAPE APPLIED TO PROTECT WALL UNDERLAY 75mm MIN.WIDE CLIP ON MS SEALANT ON PEF ROD SEALANT TO JUNCTION PROPRIETARY MANUF.STONE CLADDING FIXED ACCORDINGLY TO NOTE: FINISH CLADDING BEFORE INSTALLING STONE CLADDING CONSTRUCTION EXT.CORNER - MANUF.STONE/ SL 840
TIMBER FRAMING WALL UNDERLAY CONTINUOUS AROUND CORNERS E2/AS1 COMPLIANT BACK PROPRIETARY STONE VENEER CLADDING FIXED ACCORDING TO PLASTER WITH STO upvc CLIPON STO PREMESHED PVC CNR.ANGLES ON ALL EXT.CNRS CONSTRUCTION BOXED EXTERNAL CORNER - STONE VENEER/ SL 841
WALL UNDERLAY CONTINUOUS AROUND CORNERS RENDER CLIP ON MS SEALANT ON PEF ROD PROPRIETARY MANUF.STONE CLADDING FIXED ACCORDING TO 8 E2/AS1 COMPLIANT 50x50mm CORNER 8mm BETWEEN SHEETS, MS SEALANT JOINT TIMBER FRAMING DOUBLE STUD REQUIRED NOTE: INSTALL FC SHEET AND FINISH CLADDING BEFORE INSTALLING STONE CONSTRUCTION INTERNAL CORNER - MANUF.STONE/ SL 842
50mm MIN. COVER 50mm MIN. COVER E2/AS1 COMPLIANT BACK RENDER STO upvc CLIP ON PROPRIETARY MANUF.STONE CLADDING OVER FIXED ACCORDING TO MS SEALANT ON PEF ROD CONSTRUCTION VERTICAL JUNCTION - MANUF.STONE/ SL 843
TIMBER FRAMING 20mm DRAINED CAVITY 6mm FIBRE CEMENT SHEET RENDER WALL UNDERLAY CONTINUOUS AROUND CONERS,POLY PROPYLENE TAPE APPLIED TO PROTECT WALL UNDERLAY 75mm MIN.WIDE INSTALL FC SHEET AND FINISH CLADDING BEFORE INSTALLING SCHIST OR STONE CLIP ON MS SEALANT ON PEF ROD SCHIST OR STONE VENEER CLADDING FIXED ACCORDING TO CONSTRUCTION EXT.CORNER - SCHIST or STONE VENEER/ SL 844
RENDER WALL UNDERLAY CONTINUOUS AROUND CORNERS MS SEALANT ON PEF ROD SCHIST OR STONE VENEER CLADDING AN FIXED ACCORDING TO 50mm MIN. 8mm BETWEEN SHEETS, MS SEALANT 8 E2/AS1 COMPLIANT BACK WITH 50mm MIN. COVER TO CLADDING TIMBER FRAMING NOTE: INSTALL FC SHEET AND FINISH CLADDING BEFORE INSTALLING STONE DOUBLE STUD REQUIRED CONSTRUCTION INT.CORNER - SCHIST or STONE VENEER/ SL 845
50mm COVER 50mm COVER MS SEALANT ON PEF ROD E2/AS1 COMPLIANT BACK WITH 50mm MIN.CLADDING COVER CAVITY BATTENS RENDER STO upvc CLIP ON SCHIST OR STONE VENEER CLADDING FIXED ACCORDING TO CONSTRUCTION VERTICAL JUNCTION - SCHIST or STONE VENEER/ SL 846 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
RENDER 35mm COVER TAPE ONTO BUILDING UNDERLAY AND OVER COMPLIANT METAL VERMIN TRAY BY OTHERS upvc CLIP ON 10mm GAP NOTE: SCHIST OR STONE VENEER CLADDING FIXED ACCORDING TO TOP PIECE OF SCHIST OR STONE MUST EITHER BE PLACED OR CUT SO A 15 SLOPE IS FORMED ON THE SILL CONSTRUCTION HORIZ.JUNCTION - SCHIST or STONE VENEER/ SL 847