S4L1D-G41 Wdg Technical Data Sheet

Similar documents
S4L1S-D4 Wdg.17 - Technical Data Sheet

S0L1-J1 - Technical Data Sheet

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Technical Data Sheet

PI734A - Technical Data Sheet

WDG 12 - Technical Data Sheet

PM734B - Technical Data Sheet. Generator Solutions AS

WDG 71 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 51 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 13 - Technical Data Sheet

WDG 61 - Technical Data Sheet

WDG 07 - Technical Data Sheet

WDG 83 - Technical Data Sheet

440 (12) 416 (12) 416 (12) 440 (12)

PARTNER ALTERNATORS LSA 40-4 Pole

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Low Voltage alternators - 4 pole LSA 46.2

Low Voltage alternators - 4 pole LSA 47.2

PARTNER ALTERNATORS LSA Pole

LSA Pole. R 726 Mains paralleling

TAL 049 Low Voltage Alternator - 4 pole

TAL 047 Low Voltage Alternator - 4 pole

TAL 044 Low Voltage Alternator - 4 pole

Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

Spec Information. Reactances Per Unit Ohms

GENERATOR DATA JANUARY 30, 2015

Spec Information. Reactances Per Unit Ohms

HCM634G - Technical Data Sheet

ALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx

AGN 034 Alternator Reactance

Packaged Generators: New Kato Engineering Packaged Generator Line: Over 75 Years of Experience: Conformity: Service: Quality Standards:

Technical Data Sheet for AvK-Alternators

Technical Data Sheet for AvK-Alternators

Technical Data Sheet for AvK-Alternators

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

Technical Data Sheet for AvK-Alternators

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

AGN 005 Fault Currents and Short Circuit Decrement Curves

Generator Advanced Concepts

Generation Interconnection Study Data Sheet Synchronous Machines

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW

Application Guidance Notes: Technical Information from Cummins Generator Technologies

AGN 124 AVR Power Supplies

State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

PART 1 OWNER/APPLICANT INFORMATION

STEADY STATE REACTANCE

SPECIFICATION, CONTROLS AND ACCESSORIES

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

AGN 124 AVR Power Supplies

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

APPENDIX B: Generation Interconnection Application Form

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS

Code No: R Set No. 1

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW

SYNCHRONOUS MACHINES

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

Conventional Paper-II-2013

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

1 INTRODUCTION ORDER CODE / INFORMATION

Conventional Paper-II-2011 Part-1A

Impact Assessment Generator Form

Code No: R Set No. 1

Electrical Workstation Nvis 7089B

ECP3 4. Rev. 1. Powered by TCPDF (

Owner/Customer Name: Mailing Address: City: County: State: Zip Code: Phone Number: Representative: Address: Fax Number:

STAR ELECTRIC COMPANY

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

SPECIFICATION, CONTROLS AND ACCESSORIES

Servomotors Order Catalogue. LSN - Servomotors with stall torque 0.26 to 60 Nm

NPE32 4. Rev. 1. Powered by TCPDF (

TABLE OF CONTENT

TETRA COMPACT LOW VOLTAGE BRUSHLESS SERVOMOTORS

APPLICATION FOR INTERCONNECTION & OPERATIONS OF MEMBER-OWNED GENERATION

SPECIFICATION, CONTROLS AND ACCESSORIES

Electrical Workstation Nvis 7089A

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

Sizing Generators for Leading Power Factor

Connection Impact Assessment Application


Low Voltage Alternators

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

Kestrel Power Engineering

CONTENTS 1. SCOPE 3 2. ELECTRICAL 3 3. MATERIAL 4 4. MECHANICAL NOISE MEASUREMENT RELIABILITY PRODUCT LABEL...

AGN 022 Conditions for Parallel Operation

Downloaded From All JNTU World

DATAMAX GENERATORS DATA C E NT E R A P P L I C AT I O N S, TO K W LOW A N D H I G H VO LTAG E, 6 0 A N D 5 0 H Z

Transcription:

- Technical Data Sheet Standards Stamford industrial alternators meet the requirements of the relevant parts of the BS EN 60034 and the relevant section of other international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100 and AS1359. Other standards and certifications can be considered on request. Quality Assurance Alternators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001. Excitation and Voltage Regulators Excitation System AVR Type AS440 MX341 MX321 Voltage Regulation ± 1% ± 1% ± 0.5% with 4% Engine Governing AVR Power Self-Excited PMG PMG No Load Excitation Voltage (V) No Load Excitation Current (A) Full Load Excitation Voltage (V) Full Load Excitation Current (A) Exciter Time Constant (seconds) 12-10 0.7-0.6 48-45 2.6-2.4 0.105 Page 1

Electrical Data Insulation System Stator Winding Winding Pitch Class H Double Layer Lap Two Thirds Winding Leads 12 Winding Number 311 Number of Poles 4 IP Rating RFI Suppression IP23 BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. Refer to factory for others Waveform Distortion NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% Short Circuit Ratio 1/Xd Steady State X/R Ratio 15.8292 Cooling Air 0.78 m³/sec 0.94 m³/sec Voltage Star Xq Quad. Axis Reactance X''q Quad. Axis Subtransient XL Stator Leakage Reactance X2 Negative Sequence Reactance X0 Zero Sequence Reactance 380 400 415 440 416 440 460 480 kva Base Rating (Class H) for Reactance Values 430 450 450 430 500 535 540 560 Saturated Values in Per Unit at Base Ratings and Voltages Xd Dir. Axis Synchronous X'd Dir. Axis Transient X''d Dir. Axis Subtransient 50 Hz 60 Hz Telephone Interference THF<2% TIF<50 3.39 3.20 2.97 2.53 3.96 3.79 3.50 3.33 0.18 0.17 0.16 0.13 0.20 0.19 0.18 0.17 0.11 0.10 0.09 0.08 0.13 0.12 0.11 0.11 2.63 2.48 2.31 1.96 3.07 2.93 2.71 2.58 0.32 0.30 0.28 0.24 0.37 0.36 0.33 0.31 0.09 0.09 0.08 0.07 0.10 0.10 0.09 0.09 0.19 0.18 0.17 0.15 0.22 0.21 0.19 0.19 0.03 0.03 0.02 0.02 0.03 0.03 0.03 0.02 Unsaturated Values in Per Unit at Base Ratings and Voltages Xd Dir. Axis Synchronous X'd Dir. Axis Transient X''d Dir. Axis Subtransient Xq Quad. Axis Reactance X''q Quad. Axis Subtransient XL Stator Leakage Reactance Xlr Rotor Leakage Reactance X2 Negative Sequence Reactance X0 Zero Sequence Reactance 4.07 3.84 3.57 3.03 4.75 4.54 4.20 4.00 0.20 0.19 0.18 0.15 0.23 0.22 0.20 0.19 0.13 0.12 0.11 0.09 0.15 0.14 0.13 0.13 2.71 2.56 2.38 2.02 3.16 3.02 2.79 2.66 0.38 0.36 0.34 0.29 0.45 0.43 0.39 0.38 0.10 0.10 0.09 0.08 0.12 0.11 0.10 0.10 0.11 0.11 0.10 0.09 0.13 0.13 0.12 0.11 0.23 0.22 0.21 0.17 0.26 0.25 0.23 0.22 0.03 0.03 0.03 0.02 0.03 0.03 0.03 0.03 Page 2

Time Constants (Seconds) T d TRANSIENT TIME CONST. T d SUB-TRANSTIME CONST. T do O.C. FIELD TIME CONST. Ta ARMATURE TIME CONST. T q SUB-TRANSTIME CONST. Resistances in Ohms (Ω) at 22 0 C Stator Winding Resistance (Ra), per phase for series connected Rotor Winding Resistance (Rf) Exciter Stator Winding Resistance Exciter Rotor Winding Resistance per phase PMG Phase Resistance (Rpmg) per phase Positive Sequence Resistance (R1) Negative Sequence Resistance (R2) Zero Sequence Resistance (R0) Saturation Factors 400V 0.068 0.014 2.1 0.016 0.0092 0.0066 1.44 18 0.068 1.9 0.00825 0.009504 0.00825 480V SG1.0 SG1.2 Mechanical Data Shaft and Keys 0.24 0.24 0.99 0.99 All alternator rotors are dynamically balanced to better than BS6861: Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. 1 Bearing 2 Bearings SAE Adaptor SAE 0.5, 1 Moment of Inertia Weight Wound Stator Weight Wound Rotor Weight Complete Alternator Shipping weight in a Crate Packing Crate Size 5.6754kgm 2 561kg 482kg 1190kg 1260kg 155 x 87 x 107 (cm) Maximum Over Speed 2250 RPM for two minutes Bearing Drive End Bearing Non-Drive End Ball 6314 Page 3

THREE PHASE EFFICIENCY CURVES 50Hz 60Hz insert curves of 50Hz insert curves of 60Hz Page 4

Locked Rotor Motor Starting Curves - Separately Excited 50Hz insert 35 curve 380V 400V 415V 440V 30 PER CENT TRANSIENT VOLTAGE DIP 25 20 15 10 5 0 0 200 400 600 800 1000 1200 LOCKED ROTOR kva 60Hz insert 35 curve 416V 440V 460V 480V 30 PER CENT TRANSIENT VOLTAGE DIP 25 20 15 10 5 0 0 200 400 600 800 1000 1200 LOCKED ROTOR kva Transient Voltage Dip Scaling Factor PF Factor < 0.5 1 0.5 0.97 0.6 0.93 0.7 0.9 0.8 0.85 0.9 0.83 Transient Voltage Rise Scaling Factor For voltage rise multiply voltage dip by 1.25 Page 5

Locked Rotor Motor Starting Curves - Self Excited 50Hz insert 35 curve 380V 400V 415V 440V 30 PER CENT TRANSIENT VOLTAGE DIP 25 20 15 10 5 0 0 100 200 300 400 500 600 700 800 LOCKED ROTOR kva 60Hz insert 35 curve 416V 440V 460V 480V 30 PER CENT TRANSIENT VOLTAGE DIP 25 20 15 10 5 0 0 100 200 300 400 500 600 700 800 900 1000 LOCKED ROTOR kva Transient Voltage Dip Scaling Factor PF Factor < 0.5 1 0.5 0.97 0.6 0.93 0.7 0.9 0.8 0.85 0.9 0.83 Transient Voltage Rise Scaling Factor For voltage rise multiply voltage dip by 1.25 Page 6

Three-phase Short Circuit Decrement Curve insert curve 10000 50Hz SYMM. ASYMMETRICAL CURRENT (Amps) 1000 100 0.001 0.01 0.1 1 10 TIME (secs) insert curve 60Hz Sustained Short Circuit = 1680 Amps 10000 SYMM. ASYMMETRICAL CURRENT (Amps) 1000 100 0.001 0.01 0.1 1 10 TIME (secs) Note 1 The following multiplication factors should be used to adjust the values from curve between time 0.001 seconds and the minimum current point in respect of nominal operating voltage : Sustained Short Circuit = 1920 Amps Note 2 The following multiplication factor should be used to convert the values calculated in accordance with NOTE 1 to those applicable to the various types of short circuit : 50Hz 60Hz 3-phase 2-phase L-L 1-phase L-N Voltage Factor Voltage Factor Instantaneous x 1.00 x 0.87 x 1.30 380V X 1.00 416V X 1.00 Minimum x 1.00 x 1.80 x 3.20 400V X 1.05 440V X 1.06 Sustained x 1.00 x 1.50 x 2.50 415V X 1.09 460V X 1.10 Max. sustained duration 10 sec. 5 sec. 2 sec. 440V X 1.16 480V X 1.15 The sustained current value is constant irrespective of voltage level All other times are unchanged Note 3 Curves are drawn for Star connected machines under no-load excitation at rated speeds. For other connection the following multipliers should be applied to current values as shown : Parallel Star = Curve current value X 2 Series Delta = Curve current value X 1.732 Page 7

Typical Alternator Operating Charts 400V/50Hz Inser chart 480V/60Hz Inser chart Page 8

RATINGS AT 0.8 POWER FACTOR Class - Temp Rise Standby - 163/27 C Standby - 150/40 C Cont. H - 125/40 C Cont. F - 105/40 C 50 Hz Series Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440 kva 475 500 500 475 455 480 480 455 430 450 450 430 390 410 410 390 kw 380 400 400 380 364 384 384 364 344 360 360 344 312 328 328 312 Efficiency (%) 92.9 92.8 93.0 93.4 93.1 93.0 93.2 93.6 93.3 93.3 93.5 93.7 93.7 93.7 93.8 94.0 kw Input 409 431 430 407 391 413 412 389 369 386 385 367 333 350 350 332 60 Hz Series Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480 kva 565 600 600 625 535 575 575 600 500 535 540 560 455 485 490 510 kw 452 480 480 500 428 460 460 480 400 428 432 448 364 388 392 408 Efficiency (%) 92.9 92.9 93.1 93.1 93.2 93.1 93.3 93.3 93.4 93.4 93.6 93.6 93.7 93.8 93.9 93.9 kw Input 487 517 515 537 459 494 493 514 428 458 462 479 388 414 418 435 De-Rates All values tabulated above are subject to the following reductions: - 5% when air inlet filters are fitted - 3% for every 500 meters by which the operating altitude exceeds 1000 meters above mean sea level - 3% for every 5 C by which the operational ambient temperature exceeds 40 C - For any other operating conditions impacting the cooling circuit please refer to applications Note: Requirement for operating in an ambient exceeding 60 C and altitude exceeding 4000 meters must be referred to applications. Dimensional and Torsional Drawing For dimensional and torsional information please refer to the alternator General Arrangement and rotor drawings available on our website (http://stamford-avk.com/) Note: Continuous development of our products means that the information contained in our data sheets can change without notice, and specifications should always be confirmed with Cummins Generator Technologies prior to purchase. Page 9

Follow us @stamfordavk Cummins Generator Technologies View our videos at youtube.com/stamfordavk news.stamford-avk.com For Applications Support: applications@cummins.com For Customer Service: service-engineers@stamford-avk.com For General Enquiries: info@cumminsgeneratortechnologies.com Copyright 2016. Cummins Generator Technologies Ltd. All rights reserved. Cummins and the Cummins logo are registered trade marks of Cummins Inc. STAMFORD is a registered trade mark of Cummins Generator Technologies Ltd.