TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

Similar documents
TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

TT-SI 9001 / TT-SI MHz Active Differential Probes

TT-SI MHz DIFFERENTIAL PROBE

TT-SI MHz Active Differential Probe

TT-SI MHz Active Differential Probe

MD 200A High voltage differential probe

TA MHz oscilloscope probe TA MHz oscilloscope probe

TETRIS User's Guide. High Impedance Active Probe DO177-1

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

Operator s Manual. PP016 Passive Probe


PT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 MANUAL INSTRUCTION

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

N2792A and N2793A Differential Probes User s Guide

Active: Active probes achieve low input capacitance and high sensitivity by buffering and amplifying the signal close to the point of measurement.

400 MHz Passive High-Voltage Probe R&S RT-ZH

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

User s Manual Current Probe. IM E 2nd Edition IM E

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

Operator s Manual. PP017 and PP018 Passive Probes

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

User s Manual Current Probe IM E. 8th Edition

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

Operator s Manual. PP022 Passive Probe

PHV RO High Voltage Passive Probe. Instruction Manual

Digital Clamp Meter Model: &

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

TETRIS 1000 High Impedance Active Probe. Instruction Manual

Quick Start RSDPB5000/RSDPB4000. High Voltage Differential Probe Series

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

# Digital Multimeter

Keysight N2790A Differential Voltage Probe. User Guide

PKT 512A-RO High Impedance Passive Cable Divider

Wide-band Models from DC to 100 MHz

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

AC/DC CLAMP METER USER S MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL

N2790A Differential Voltage Probe

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

The Meter Structure The Figure 2-1 shows the Meter structure.

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

KMD-S04 Multímetro de bolsillo

BENNING. CM7 Electrical Tester. Service Information

RIGOL. User s Guide. RP1003C/RP1004C/RP1005C Current Probe. Mar RIGOL Technologies, Inc

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, this instruction manual is the description about t

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

Agilent N2780A, N2781A, N2782A, and N2783A Current Probes

DM-45 Digital Multimeter

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, the product specification is about the function, u

9 Specifications. Specifications NOMINAL CHARACTERISTICS

Pen-type DIGITAL MULTITESTER

INSTRUCTION MANUAL CLAMP ON PROBE

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

User s Manual Current Probe IM E. 6th Edition

5MHz FUNCTION GENERATOR

T5-600/T Electrical Tester

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

5MHz FUNCTION GENERATOR

DMM8900 SERIES USERS MANUAL

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

Choosing the right Pico Technology active differential probe

AP034-OM-E Rev D ISSUED: January 2000 ²

Documentation. PerfectPulse Fast Edge Signal Generator

DS1000E, DS1000D Series Digital Oscilloscope

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

Oscilloscope Probes and Accessories

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

EC Declaration of Conformity

Digital Multimeter, Pen Type

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Keysight N2771B 30 kv High Voltage Probe

AX-C Introduction. 2. Safety Information

80i-110s AC/DC CURRENT PROBE

Digital Clamp Meter. User Manual

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

CONTENTS MS2033A. 1.Introduction Safety Information...01

Preface First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention

374/375/376 Clamp Meter

Model 4007DDS. 7 MHz Sweep Function Generator

PicoSource PG900 Series

Model UT10A: OPERATING MANUAL Table of Contents (1)

PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip

DVM1190 DIGITAL MULTIMETER

User Manual Current Probe Instruction Manual

374/375/376 Clamp Meter. Users Manual

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Transcription:

TA041 25 MHz ±700 V Differential Probe User s Manual This probe complies with IEC-1010.1, IEC-1010.2-031 CAT III, Pollution Degree 2. 1. Safety terms and symbols Terms appearing in this manual: WARNING Warning statements identify conditions or practices that could result in injury or death. CAUTION Caution statements identify conditions or practices that could result in damage to this product or other property. Symbols appearing on the product: Danger High Voltage Protective (Earth) Terminal Attention Refer to Manual DO141-4

TA041 User s Manual Pico Technology 2. General safety summary Please review the following safety precautions to avoid injury and prevent damage to this probe or any products that are connected to it. Observe maximum working voltage To avoid any injury, do not use the probe above 1000 V RMS CAT III between each input lead and earth or between the two input leads. This voltage rating applies to both the 1:10 and the 1:100 settings. Ground the probe This probe is grounded with the shell of the BNC connector and an auxiliary grounding terminal. WARNING Before making connections to the input leads of this probe, ensure that its output lead is grounded. You may do this either by connecting the BNC shell to a grounded measurement instrument, or by connecting the auxiliary grounding terminal to a reliable ground point. Read the next paragraph for further advice. You must verify that the probe is securely grounded before connecting the probe input leads. Some types of measuring instrument, such as a USB oscilloscope connected to a laptop, are unlikely to be grounded even if the laptop is powered from the mains. Bench-top oscilloscopes are usually grounded, but in some cases may have been isolated from ground. A USB oscilloscope connected to a desktop computer is usually grounded. In any case, do not assume that the measurement instrument is grounded. Always verify the ground connection for yourself before connecting the probe input leads. Use fused test prods if necessary If this probe is intended to use for measurements in circuits of INSTALLATION CATEGORY III, it should incorporate with fused test prods. Do not operate without covers To avoid electric shock or fire hazard, do not operate this probe with the covers removed. Do not operate in wet or damp conditions To avoid electric shock, do not operate this probe in wet or damp conditions. Do not operate in explosive atmosphere To avoid injury or fire hazard, do not operate this probe in an explosive atmosphere. 2 Copyright Pico Technology 2008 2012 DO141-4

Pico Technology TA041 User s Manual Avoid exposed circuitry To avoid injury, remove jewelry such as rings, watches and other metallic objects. Do not touch exposed connections and components when power is present. Use proper power source To ensure proper functioning of this probe, use four AA cells, a 6 V DC 60 ma mains adaptor, a 9 V DC 40 ma mains adaptor, or power leads. Do not operate the probe if it is damaged If you suspect there is damage to this probe, have it inspected by qualified service personnel. 3. Description By enabling conventional oscilloscopes to display and measure in-circuit waveforms that are referenced to high common-mode voltages, this differential probe extends the measurement capability of oscilloscopes to electronic power converters, inverters, motor speed controls, switch-mode power supplies and many other applications. 4. Installation Simply plug in the BNC output connector to the vertical input of a general-purpose oscilloscope or other measurement instrument, and connect the auxiliary grounding terminal to a proper ground. The measurement instrument must have a ground reference. Install four AA cells or connect an appropriate power source to this probe. Select the proper attenuation ratio. When measuring signals below 70 V, switch the attenuation ratio to 1:10 in order to get higher resolution and less noise. Otherwise, set the attenuation to 1:100. WARNING To protect against electric shock, use only the accessories designed for use with this differential probe. Using the appropriate probe accessories, connect the input to the circuits under measurement. CAUTION This probe is designed for carrying out differential measurements between two points on the circuit under test. It is not intended for electrically insulating the circuit under test and the measuring instrument. DO141-4 Copyright Pico Technology 2008 2012 3

TA041 User s Manual Pico Technology 5. Signal leads a b c a. Output Lead. The BNC output connector and an auxiliary grounding terminal are connected to the oscilloscope. b. Input Leads. The input leads of the differential probe connect to sprung hooks that come with the probe. c. Sprung Hooks. The sprung hooks are connected safely to test points in the circuits under test. 6. Power leads Two types of power leads are available for use with this instrument: 1. Lemo Lead: For oscilloscopes with Lemo power connectors. 2. Probus Lead: For oscilloscopes with Probus power connectors. Oscilloscope front 4 Copyright Pico Technology 2008 2012 DO141-4

Pico Technology TA041 User s Manual 7. Specifications Bandwidth DC to 25 MHz (-3 db) Attenuation ratio 1:10 or 1:100 switchable DC accuracy ±2% Rise time 14 ns Input Impedance 4 MΩ 5.5 pf each side to ground Input Voltage Differential Range* (1/10) Differential Range* (1/100) Common Mode Range* ±70 V (DC + Peak AC) or 70 V RMS ±700 V (DC + Peak AC) or 700 V RMS ±700V (DC + Peak AC) or 700 V RMS (1:10 and 1:100) Absolute Max. Voltage* ±1400 V (DC + Peak AC) or 1000 V RMS CAT III (Differential or common-mode) (1:10 & 1:100) Output Swing ±7 V into 2 kω load Offset (typical) <±5 mv Noise (typical) 0.7 mv RMS Source Impedance (typical) 1 Ω @ 1 khz, 8 Ω @ 1 MHz CMRR (typical) 86 db @ 50 Hz; 66 db @ 20 khz Ambient Operating Temperature 10 to +40 C Ambient Storage Temperature 30 to +70 C Ambient Operating Humidity 25 to 85% RH Ambient Storage Humidity 25 to 85% RH Power Requirements Standard 4 AA cells or 6 V DC 60 ma mains adaptor** or regulated 9 V DC 40 ma mains adaptor** Options Power leads Length of Input Leads 45 cm Length of BNC Lead 95 cm Weight 400 g (inc. probes and PVC jacket) Dimensions 170 x 63 x 21 mm (LxWxH) * Voltage limit is the lesser of the DC+Peak AC and RMS values. ** 1. The supplied voltage must be less than 12 V and greater than 4.4 V, otherwise the probe could be damaged or might not operate properly. 2. Polarity is + inside and outside. If the polarity is wrong, a built-in circuit protects the probe so that no danger or damage will occur. 3. When the voltage of the cells becomes too low, the power indicator on the panel will flicker. DO141-4 Copyright Pico Technology 2008 2012 5

Voltage (V RMS) TA041 User s Manual Pico Technology 8. Derating curve The derating curve for absolute maximum input voltage is as follows: 10000 1000 1000 1000 700 100 150 1.E+06 1 M 1.E+07 10 M 100 1.E+08 M Frequency (Hz) 6 Copyright Pico Technology 2008 2012 DO141-4

Pico Technology TA041 User s Manual 9. Test procedure 1. Connect the BNC output connector to the vertical input of a general-purpose oscilloscope. 2. Install four AA cells or connect an appropriate mains adaptor to this probe. 3. Set the oscilloscope input coupling to DC and 1 V/div. Center the trace on the display. 4. Connect the sprung hooks of the probe to power lines. 5. Set the range of the probe to 1:100. 6. A 50 Hz or 60 Hz sine wave of proper amplitude will be displayed on the screen of the oscilloscope. This means the probe is working properly. 10. Calibrating the unit There are three main sources of uncertainty when calibrating a Pico differential probe in addition to any uncertainty in the test setup. These are: 1. The stated DC accuracy of the probe under test (±2%). 2. Any DC offset or noise in the probe output. The values in this manual are typical, so to find the DC offset for a given unit a reading must be taken with the inputs to the probe shorted together. 3. The AC performance of the probe. This is specified as being within 3 db over the entire frequency range of the probe. Any absolute voltage accuracy testing must be done under DC conditions. One other possible source of noise is the power source for the probe. It is recommended that where possible the probes are calibrated using a battery supply rather than a mains supply unit. The adjustment procedure is available from Pico Technology on request. 11. Cleaning Use a soft cloth to clean the probe, taking care not to cause damage. 1. Do not immerse the probe. 2. Do not use abrasive cleaners. 3. Do not use chemicals containing benzene or similar solvents. DO141-4 Copyright Pico Technology 2008 2012 7

Issue history: 1 28.08.08 First issue. 2. 24.09.08 Renamed to TA041. 3. 06.08.10 Reformatted derating curve axis labels. Corrected Swing data. 4. 11.04.12 Added calibration notes. Pico Technology James House Colmworth Business Park St. Neots Cambridgeshire PE19 8YP United Kingdom www.picotech.com Lemo, Probus and Pico Technology are registered trademarks. Manufactured in Republic of China. 8 Copyright Pico Technology 2008 2012 DO141-4