Power Quality Analyser TOPAS 1000

Similar documents
Power Quality Analyzer Topas 2000

Power Quality Analyser MEMOBOX 300 smart

Fluke Three-Phase Power Quality Recorder Topas. Class-A compliance for the most demanding power quality tests

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Digital-Multimeter UNIGOR 380, UNIGOR 390

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

Network Analyzer for Low-, Medium- and High-Voltage Networks

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards

Network Analyzer for Low-, Medium- and High-Voltage Networks

Network Analyzer for Low-, Medium- and High-Voltage Networks

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Power Quality Analyzer / High Frequency Recorder

Side view View from below Rear view

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

Smart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE

METRAClip87 and 88 Clamp Multimeters

High precision measurement system for current and voltage IHC-A/B-RM01/03

MEASURING INSTRUMENTS AND TESTERS

Operating Instructions

Choosing your power quality analyzer

Digital-Multimeter UNIGOR 380, 390

UMG 509-PRO. Multifunction power analyser with RCM

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

Fluke 1750 Three-Phase Power Recorder

02/11/2015

02/11/2015

UMG 103-CBM. Universal measurement device for DIN rails

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

Fluke 3540 FC Three-Phase Power Monitor

Low Frequency Measuring System

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Fluke Norma 4000/5000

Supervision and analyse of the electrical network EN50160 & POWER QUALITY

PQM3000R Class A network analyzer according to EN for power quality monitoring

A Power Quality Interface for Low and Medium Voltage Smart Grids

E6500 Power Quality Analyzer

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

Fluke Norma 4000/5000

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals

PQube 3 Specifications

CMC 256plus - protection relay test set and universal calibrator

ULTRA RAPID POWER QUALITY ANALYZER

Energy Explorer PROFESSIONAL POWER & HARMONICS ANALYSER

NI 6731/6733 Specifications

PQM3000RGW Class A rack 19 power quality analyzer with Rogowski coils

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

Fluke 3540 FC Three-Phase Power Monitor

PEM353. Universal measuring device

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Fluke Advanced Test Equipment Rentals ATEC (2832) Three-Phase Power Recorder

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

PQM3000 Class A rack 19 power quality analyzer for CTs or current clamps

HAWK5000 Operators Manual

C.A 8332 C.A Advanced Test Equipment Rentals ATEC (2832) Display your network analysis all in picture format!

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

METRAClip85 and 86 Clamp Multimeters

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

Three Phase Power Calibrator and Tester of Power Engineering Devices

Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

Complimentary Reference Material

Power Analyser AM-10-PA2

C.A 8332 C.A Display your network analysis all in picture format! OBSERVE, DIAGNOSE, MONITOR... Three Phase Power Quality Analysers

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

Reliable Power Meters Multipoint Power Recorder

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

DM-5 Power Quality Analyzer

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

RCTrms Technical Notes

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

SOLAR300N Rel /01/10

Moving Test - MT3000

Data Sheet. RISH Master Record %THD

GAMMA 20 DIGITAL MULTIMETER

With any other power quality analyzer you re just wasting energy.

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

SIEMOS PQ The Multi-Functional Power Quality Analyzer for Low and Medium-Voltage Networks

1587/1577 Insulation Multimeters

Fluke Three-Phase Power Recorder. Plug and play: Set up in minutes with selfidentifying

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Voltage Transient Emission Test

DOBLE F6150e TECHNICAL SPECIFICATIONS

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

Electrical Network Analyzers

Fluke Three-Phase Power Recorder. Never miss capturing a disturbance - with the exclusive threshold-free measurement system, it s automatic.

DOBLE F6150SV TECHNICAL SPECIFICATIONS

Power Quality and Energy Measurement PEM575

Transcription:

Power Quality Analyser TOPAS 1000 Effecting measurement tasks in medium and low voltage networks faster and with a single tool: Analysis of disturbances and their causes Determine reserves of transformer/feeder Acquire and analyse transient events Power quality as per EN 50160 Detection of interferences, power peaks Function test of ripple control systems Day extreme values Report writer General Measuring System TOPAS 1000 is a power network analyser that can be used to locate interference sources and assess mains voltage quality in compliance with the applicable standards. The extremely rugged mechanical construction (IP65) of TOPAS 1000 is highly estimated especially under harsh or wet conditions. The large data memory (512 MB Compact Flash-card, optional 1 GB or 2 GB) provides effecting long-term recordings. These recordings are the basis for detailed evaluations and analyses to assess disturbances and the mains voltage quality. TOPAS 1000 was developed in cooperation with power utilities optimised for field applications and the requirements of operating electrical energy assets. TOPAS 1000 fields of applications: Disturbance source detection Voltage, current and power analysis Load and energy measurements Transient analysis Signalling voltage analysis (ripple control systems) Power quality analysis as per EN 50160 Measurement methods, evaluations: Assessment of PQ as per EN50160 rms values with adjustable intervals Sample values (oscilloscope) Amplitude spectrum Signalling voltage analysis (ripple control systems) Transients General specification Intrinsic error: Quality system: refers to reference conditions and is guaranteed for two years developed, manufactured as per DIN ISO 9001 Environment conditions: Operating temp. range: 0 C... +40 C Storage temp. range: -20 C... +70 C Relative humidity: 10... 80, no dewing Operating altitude: max. 2000 m Reference conditions: 23 C ±2K, 230 V ±10, 50 Hz / 60 Hz 10 minute intervals, PF=1.0 Housing: Protection: Safety: insulated, robust housing IP65 as per EN 60529 with interface cover closed TOPAS 1000 is conform to CE-marking, complies to EN 61010-1 EMC: Emission: EN 61326-1: 1997 p. 12, table 3: limits for class A equipment Immunity: Voltage inputs: EN 61326-1: 1997, EN 61326-6/7, amendment A1: 1998

Power supply: Range Safety: Power consumption: AC: 83 V 264 V, 45...65Hz DC: 100 V... 375 V IEC/EN 61010-1 300 V CAT II, class I max. 30 VA In case of a power supply failure an internal accumulator maintains the supply for up to 3 minutes. Afterwards, or in case of discharged accumulators the TOPAS 1000 is turned off and continues the measurements as soon as the supply voltage returns. The accumulator can be replaced by the user. Display TOPAS 1000 features 9 LEDs as status display for the 8 channels and the power supply. Power LED Permanent light: normal power supply from mains. Flashing light: supply via internal accumulator in case of a power failure. Channel LEDs OFF, brief light ON: too low or no measuring signal ON, brief light OFF: overload Permanent light: channel o.k. Rapid flashing: sensors incorrectly connected. Data memory: Memory model: Internal 512 MB Compact Flash card, 1 GB, or 2 GB CF-card optional linear or circular Interfaces: Ethernet (100MB/s, compatible to Windows 98/ME/NT/2000/XP RS 232 external modem connected to RS 232 Baudrate for RS 232: 9600 Baud 115 kbaud Dimensions: 325 mm x 300 m x 65 mm (H x W x D) Weight: Warranty: appr. 4 kg (without accessories) 2 years Calibration interval: 2 years recommended Self-test TOPAS 1000 features comprehensive functions for system diagnosis. The internal data memory, input channels, sensors, interfaces and battery are tested and a diagnosis protocol is created. The analogue channels are tested by measuring the noise voltage and the offset voltage. Block diagram 83... 264 V AC 100...375 V DC Overvoltage protection Mains detection Mains/Accu Accu Signal conditioning Sampling The sampling rate is synchronised to mains frequency in the range from 45-65 Hz with a resolution of 10 ppm and is 6.400 Hz in the 50 Hz network. The absolute error for frequency measurements is 200 ppm. Measurement intervals Voltage, current rms values: 10 ms, 3 s, 10 min, 24 h. Min-, Max-values: 10 ms rms values Transients: 100 khz 10 MHz sample rate per channel Frequency: 10 s, 3 s, 10 min, 1 h, 24 h Harmonics: 160 ms / 320 ms Flicker: as per EN 61000-4-15: 10 min (Pst), 2 h (Plt) Measurement inputs TOPAS 1000 features 8 galvanically isolated inputs for voltage and current measurements. Safety: Nominal voltage (rms): Range (peak value): Overload capacity (rms): Voltage rise rate: Input resistance: Input capacitance: Intrinsic error: 200 mv 280 mv 1000 V, continuously max. 15 kv/µs 1 MΩ 5 pf < 1 between 0 2500 Hz Intrinsic error for harmonics: class A as per EN 61000-4-7 Each channel is equipped with a passive low-pass filter, an antialiasing filter and a 16-bit A/D converter. All channels are sampled synchronously with a common quartz-controlled clock pulse. The filters protect against voltage transients and limit the signal rise rate, reduce high frequency components and especially the noise voltage above half the sampling rate of the A/D converter by 80dB, thus achieving very small measuring errors in an exceptionally large amplitude range. This is also valid under extreme operating conditions like transient voltages at the output of converters. TOPAS 1000 effects measurements with precisely defined frequency response. Between the 3dB limit frequency at 0.45-fold sampling frequency and the 1.2 higher frequency the amplitude response falls 80dB below the A/D converter s resolution. Particular attention is paid to identical phase responses of the analogue inputs in order to avoid errors during power measurement. Frequency response 0 Hz to 2500 Hz Signal level: 100, sampling rate fs = 10.24 khz: AC DC Accu- Management V-Sensor EEPROM Ethernet I-Sensor EEPROM Sensor-ID evaluation RS 232 FIFO Dig. I/O Clock generation Synchronisation CPU 512 MB CF-card 2

Frequency response from 0 Hz to 100 khz - Signal level: 100 Phase difference between any input channels Signal frequency: 0 0.54 fs Linearity - Signal frequency: 50Hz, sampling rate fs = 6.4 khz: Accuracy The total measuring error of the measurement system TOPAS 1000 including voltage or current sensor is far below class 0.5 and the error for harmonics complies with class A of standard EN 61000-4-7. TOPAS 1000 is suited for current, voltage and power measurements at the output of frequency converters. Current measurements on the converter with shunts are possible. Taking into account the maximum voltage rise rate the same error indications apply. The total error results from the error of the TOPAS 1000 measurement channel and the error of the connected sensor. The error values apply to reference conditions, warmed up instrument without sensors up to the maximum voltage rise rate. Frequency Signal level Errors U, I in of m. v. Errors for power, PF=1 in of m. v. 50 Hz 100 <0.1 <0.2 50Hz >1 <0.5 <1 <2500 Hz 100 <1 <1.2 <2500 Hz >1 <1.2 <2.2 Common mode rejection Common mode rejection between 0 Hz and 100 khz: -130 db of measuring range. Temperature drift Change of amplification through temperature: < 150 ppm / K. Ageing Change of amplification due to ageing: < 0.06 / year. Noise Noise voltage, input short-circuited: < 20 µv. Spectral noise voltage density: 0.4 µv / Hz. Measurement functions TOPAS 1000 is a data logger recording measuring data for long periods of time or transferring them online to an analysis computer (typically a notebook). Measuring data can be retrieved during data logger operation without interrupting the measurements via one of the existing interfaces. An online display is also available. TOPAS 1000 measures 4 currents and 4 voltages or 8 voltages alternatively. Data Logger mode Assessment of the power quality as per EN 50160, rms values, extreme values, Flicker intensity, voltage dips, voltage interruptions (long and short), voltage swells, voltage unbalance, harmonics, THD, inter-harmonics, signalling voltages, power harmonics (amplitude and phase angle), transients are recorded with various averaging intervals. Online mode Sample values (waveforms, oscilloscope) of current and voltage, amplitude spectrum of active and reactive power and transients, rms values, active power, power factor, phasor diagrams of voltage, current, and apparent power are available in the online mode.. Measurement methods Assessment of the power quality as per EN 50160 Harmonics THD U Flicker Voltage events Unbalance Frequency Averaging intervals for 20 ms... 24 h rms values of voltage, current Active power Apparent power Power factor Energy Day extreme values Oscilloscope presentation of Voltage Current Transients (optional) Recording of 4 voltage channels 100 khz up to 10 MHz sampling rate per channel 20 ms to 2 s recording period Triggering at voltage levels of high-frequency signal components 6 kv input voltage range Amplitude spectrum of Voltage, current Active power, reactive power Ripple control signals Ripple control signals (voltage, current, active power, power factor) Frequency Level Course versus time Symmetrical components Zero-, positive negative sequence 3

Measurement functions - overview Power quality all parameters as per EN50160 1 day average values Free intervall (1 min 1 day) 10 minute average values: voltage, current, frequency, Flicker, power values, symmetrical components Events, triggers Dips, swells, interruptions 3 sec average values: Harmonics, THD Rms values Averaging time adjustable between 10 ms 1 day Sample rate: 10,24 khz / channel Transients: 100 khz 10 MHz / channel Ripple control signals on phases and N-conductor Voltage, current active power Trigger conditions TOPAS 1000 can determine the trigger thresholds automatically. This operating mode requires no settings. The trigger thresholds can also be set manually by the user. If the trigger thresholds are exceeded harmonics, rms values and powers, oscilloscope views of current and voltage, transients and signalling voltages can be recorded. It is also possible to trigger upon exceeding one or more harmonics (1 50). For all channels it is possible to trigger on upper or lower violation of oscilloscope or rms threshold values. Hardware settings Current and voltage sensors can be connected to any channel. The assignment measured quantity channel and the setting of the measuring range are effected during configuration. Certain measuring ranges or sensors can be predefined. If the wrong sensor is connected in that case the measuring instrument will react by flashing the LED of the respective channel. An additional scaling factor can be entered for each channel: the transformer ratio of current or voltage transformers can be taken into account. Measuring data analysis The measuring results are presented graphically as level time diagrams, or cumulative frequency functions, or bar diagrams. Different data can be superimposed in one diagram. Each data point can be selected by cursor and its data displayed in numerical fields. Sections of a diagram can be exported as a text table. Copy & Paste via the Windows clipboard is possible. ASCII-tables can be imported into spreadsheet applications. Day extreme value presentations compress data out of long-term recordings to comprehensive evaluations. A configurable report writer provides repetitive protocol generation. EN 50160 analysis This analysis provides a rapid overview of the power quality. By red and green bars we can see whether the PQ is compliant or if further investigations are necessary. Online mode oscilloscope transients events 4 Configuration Before starting data logging TOPAS 1000 must be configured with a computer and the TOPAS software. Configuration files can be stored, loaded and compiled with menu-guidance. The configuration menu provides for the following settings: Descriptive text A descriptive text can be entered into a text box with information on the measurement. Nominal values and limit values All the limits complying with EN 50160 can be set. Interharmonics The rms value of all interharmonics and the TID is measured. If a preset threshold is exceeded oscilloscope values are recorded and the interharmonics can be evaluated. Measuring time Start time and stop time for measurement campaigns can be defined. A universal time trigger records pre-selected parameters during defined time periods, also periodically if required. Memory management The amount of memory for various measurement parameters can be reserved. This will avoid the memory being filled unintentionally e.g. with oscilloscope values. The memory management can be circular or linear. Linear: no more data is stored on reaching the memory limit. Circular: the oldest data records are overwritten.

Power quality overview as per EN50160 in CODAM format: Day extreme values In this presentation the measurement data of a long period are presented as a day profile. A compliance report (text protocol) can be issued immediately. Events list A compact overview of all events that occurred (30.000 events occupy 1MB of memory only). This list can be transferred without problems even via modem connections. Oscilloscope The oscilloscope function is used to evaluate current and voltage waveforms. Highly distorted voltages cause thermal overloads of neutral wires and transformers. With the sorting functions it is possible to select and analyse the most important events. Clicking on the items in the list opens immediately detailed presentations (level-time diagrams) for further analysis. Transients Transient short voltage swells caused by switching in the network or lightning strikes can destroy electronic devices. Only by means of transients analysis such influences can be examined. CBEMA presentation The events can also be displayed in the CBEMA (ANSI) diagram events are classified according to amplitude and duration. Electronic devices can also be the reason for such interferences which can be located only with fast-sampling transient analysis. Amplitude spectrum of voltage, current and power is provided. 5

Ripple control signal analysis Some equipment like street lighting and heating devices are remote controlled by means of signalling voltages. Multi-tariff meters can also be switched with these signals. Interferences may result in comprehensive, time-consuming analysis and damage to equipment. Order number Input resistance 2) Intrinsic error Safety EP1012A 1 MOhm - 300 V CAT II A 6805 02004 16 kohm 0.15 300 V CAT II EP 1002A 16 kohm 0.15 300 V CAT II EP 1110A 16 kohm 0.15 300 V CAT II A 6805 02001 2 MOhm 0.15 A 6805 02002 2 MOhm 0.15 A 6805 02002 1) 2 MOhm 5 EP1011A 4 MOhm 0.2 EP1011A 1) 2 MOhm 5 EG 0001Z 2 MOhm 0.15 A 6805 02007 2 MOhm 0.15 EP 1010A 4 MOhm 0.15 CAT IV 1) with TOPAS 1000 with Transient option only 2) input resistance between red and black connector This function provides a very useful tool to detect the source of interferences. All quantities which could influence these signals are analysed and displayed (signal level too low, pulse rise rate too low,...) Test probes technical specification Voltage probes for various ranges between 200 mv and 1000 V are available for TOPAS 1000. Current sensors for direct current measurement (shunts) are available between 20 ma and 5 A. Passive current clamps (AC only) are available in ranges with 1 A up to 1000 A, 2 ranges can be selected in the TOPAS software. Flexible current sensors (LEM~flex) are available for ranges between 100 A and 6000 A AC, 2 ranges can be selected in the TOPAS software. All probes contain a memory for calibration factors, sensor identity and serial number which is read automatically by TOPAS 1000. Ranges can be selected in the TOPAS software. Other measuring transducers can be used in front of these standard sensors. Voltage Sensors Temperature drift: 100 ppm / K Aging: <0.06 / year All voltage sensors are suitable for DC... 3 khz. Order number Trans. Option U nom Range rms U max contin. EP1012A - 0.2 V 0.01 0.2 V 100 V A 6805 02004-1 V 0.01 1.7 V 100 V EP 1002A - 5 V 0.05 8.5 V 100 V EP 1110A - 10 V 0.1 17 V 100 V A 6805 02001 yes 100 V 1 170 V 1000 V A 6805 02002 yes 400 V 4 680 V 1000 V A 6805 02002 1) yes 6000 V 6000 V <1 ms 1000 V EP1011A yes 400 V 4 680 V 1000 V EP1011A 1) yes 750 V 5 750 V 1000 V EG 0001Z yes 480 V 4.8 820 V 1000 V A 6805 02007 yes 830 V 10 1400 V 1000 V EP 1010A yes 1000 V 10 1700 V 2000 V Current sensors - specification Sensor type ranges Peak current *) Clip-on current transformers for AC current 1 A / 10 A A 6805 01049 5 A / 50 A A 6805 01048 20 A / 200 A A 6805 01050 100 A / 1000 A A 6805 01052 LEM~flex for AC current 100 A / 500 A EP 1205A 200 A / 1000 A EP 1210A 3000 A / 6000 A EP 1360A 0.01 A...1 A 0.1 A...10 A 0.05 A 5 A 0.5 A...50 A 0.2 A...20 A 2 A...200 A 1 A 100 A 10 A 1200 A 1 A...100 A. 5 A 500 A 2 A...200 A 10 A 1000 A 30 A 3000 A 60 A 6000 A Shunts for AC and DC currents **) 20 ma 0 55 ma A 6805 01057 1 A A 6805 01054 5 A A 6805 01055 0 2.8 A 0 10 A 3.7 A 37 A 18 A 180 A 74 A 300 A 370 A 1700 A 240 A 1350 A error 0.5 0.5 0.5 0.5 1 480 A 2700 A 1 10 ka 19 ka 77,8 ma I max =1,5A 4,0 A I max =6,5 A 21,9 A Imax=10 A 1 0.2 0.2 0.2 Frequency range 40 Hz 10 khz 40 Hz... 10 khz 40 Hz... 10 khz 40 Hz... 10 khz 45 Hz... 45 Hz... 45 Hz... DC... DC... DC... Phase error 0.1 0.1 0.1 Errors in of measuring range at 23 C ±3K, for 48 65 Hz Phase angle error at nominal current *) for sinusoidal currents **) I max maximum current without time limit operating voltage 300 V CAT II 300 V CAT II 300 V CAT II 6

Scope of delivery, accessories, service Power Quality Analyser TOPAS 1000 Standard equipment 8 channels (4 x current / 4 x voltage or 8 x voltage), EN50160 + Ripple control option, Ethernet, RS232 interface, 512 MB CF-card A 5505 10010 TOPAS 1000 TS TOPAS 1000 3 LEM~flex 200 A / 1000 A, 3 sensors 400 V, trigger option, carrying case A 5505 10011 TOPAS 1000 S TOPAS 1000 3 LEM~flex 200 A / 1000 A, 3 sensors 400 V EP1130A TOPAS 1000 S TOPAS 1000 3 x 1 A / 10 A current probes, 3 sensors 400 V, EP1140A TOPAS 1000 S TOPAS 1000 3 sensors 400 V EP1150A Options Trigger function EN50160 Transient analysis 10MHz Transient analysis 500kHz automatic, manual triggers for 4 voltage channels and 4 current channels or 8 voltage channels, harmonics, THD A 5505 00110 EN50160 option for evaluation of power quality + ripple control option EP0160A for 4 voltage channels, sampling rate: 100 khz - 10 MHz, range: 6 kv, event storage depth 20 ms - 2 s A 5505 00210 for 4 voltage channels, sampling rate: 100 khz - 500 khz, range: 6 kv, event storage depth 400 ms - 2s A 5505 00211 NOTIFY Fault messaging software EK 2100Z Relay box 8 digital alarm outputs A 5505 00320 1 GB CF-card Memory expansion A 5505 00351 2 GB CF-card Memory expansion EP1523A Accessories LEM~flex 100 A / 500 A, 45 cm, 2 m cable EP1205A 200 A / 1000 A, 61 cm, 2 m cable EP1210A 3000 A / 6000 A, 91 cm, 4 m cable EP1360A Current probes 1 A / 10 A, max. conductor cross section 15 mm, 2 m cable A 6805 01049 5 A / 50 A, max. conductor cross section 15 mm, 2 m cable A 6805 01048 20 A / 200 A, max. conductor cross section 15 mm, 2 m cable A 6805 01050 100 A / 1000 A, max. conductor cross section 54 mm, 2 m cable A 6805 01052 Voltage sensors 0.1 V EP1012A 1 V A 6805 02004 5 V EP1002A 10 V EP1110A 100 V A 6805 02001 400 V A 6805 02002 480 V EG 0001Z 400V / 750 V EP1011A 830 V A 6805 02007 1000 V EP1010A Shunts 20 ma A 6805 01057 1 A A 6805 01054 5 A A 6805 01055 GSM modem set A 5505 00330 ETHERNET cable set EP0004A Adapter for current and power measurements A 6045 10200 Safety adapter with high performance fuse A 6805 02003 Attachement for belt assembly 2 attachements, 1 carrying belt A 5505 00411 Carrying case A 5505 00410 ASC-02 certificate with measurement values E012000030 7

Distributor: www.lem.com Printed in EU Technical modifications reserved Publication A24330E LEM NORMA GmbH LEM HEME LTD. LEM Instruments Inc. LEM Instruments, Inc. LEM BE sa/nv Export department Geneva Court 23822 Hawthorne Boulevard #100 Av. Camino Real, 871 Avenue Newton, 8 Liebermannstraße F01 1 Penketh Place US-TORRANCE, CA 90505 dpto. 502 B-1300 Wavre CAMPUS 21 West Pimbo TEL: +1 310 373 09 66 San Isidro - Lima 27 - Perú TEL: +32 10 22 67 16 A-2345 BRUNN AM GEBIRGE Skelmersdale, UK-Lancashire WN8 9QX FAX: +1 310 373 90 56 TEL: +51-1- 422 03 08 FAX: +32 10 22 69 98 TEL: +43(0)2236 691 502 TEL: +44(0)1 695 72 07 77 E-mail: liu@lem.com Mobile:+51-1- 9844 55 59 E-mail: lbe@lem.com FAX: +43(0)2236 691 400 FAX: +44(0)1 695 50 704 FAX: +51-1- 221 64 92 E-mail: lna@lem.com E-mail: luk@lem.com E-mail: cpg@lem.com