R1 Q2 Q1 F2 F1 N A1 A2 FUSE V AC S UF OE SL UF OE R150 R150. AVRs. Installation and maintenance

Similar documents
R180. AVRs. Installation and maintenance

V S UF OPEN IN 60Hz OE UF SL R120 V N1 U N F1 F2 A.V.R. R120. Installation and maintenance

R1 Q2 Q1 F2 F1 N A1 A2 FUSE V AC S UF OE SL UF OE R150 A.V.R. R150. Installation and maintenance

A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. REQUEST A QUOTE

R438 A.V.R. R438. Installation and maintenance X2 Z1 X1 Z2 E+ E- 0V REQUEST A QUOTE

R / 8000 RAPIDE FAST RAPIDE 3 PAHASES SENSING SHUNT / AREP SERIES PMG NORMAL NORMAL NORMAL NORMAL 5000 / 6000 LSA 46 / 47

R438 A.V.R. Installation and maintenance. This manual is to be given to. the end user CALL US TODAY POWER-58. SHOP ONLINE

R450 T DETECT. 3 PH 3 PH. SENSING 7000 / 8000 RAPIDE FAST RAPIDE VOLTAGE 80V ~ 320V SHUNT / AREP SERIES PMG NORMAL NORMAL NORMAL NORMAL 5000 / 6000

R448 & R448 V50 A.V.R.

R448 & R448 V50 A.V.R. Installation and maintenance R 448 ST5 ST3 ST10. Armature + 6- Field X2 Z1 X1 Z2 E+ E- 0V Slow fuse 250V 10 A

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

r 450 Installation and maintenance This manual is to be given to the end user R 450 VOLT. STAB. I EXC STAT. AREP PMG FUSIBLES / FUSES

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

R 450. AVRs. Installation and maintenance. This manual is to be given to. the end user R 450 VOLT. STAB. I EXC STAT. LEDS PMG

VOLTAGE REGULATOR R 449. Installation and maintenance. This manual must be sent to the end user R 449 X2 Z1 X1 Z2 E+ E- (12V - 10A)

SPECIFICATION, CONTROLS AND ACCESSORIES

SPECIFICATION, CONTROLS AND ACCESSORIES

R241 A. 400 Hz A.V.R. Installation and maintenance. This manual is to be given to. the end user C B. Air craft p

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

SPECIFICATION, CONTROLS AND ACCESSORIES

Using the VR448 in place of the Marathon DVR 2000

GX 340 SERIES (AUTOMATIC VOLTAGE REGULATOR)

ADVR-053. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

WDG 07 - Technical Data Sheet

WDG 13 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 83 - Technical Data Sheet

WDG 71 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

WDG 61 - Technical Data Sheet

Instructions AVC125-10: Voltage Regulator. Voltage Range. Maximum Continuous Burden. Voltage Range. Nominal Frequency

M40FA640A/A - Mark I. User Manual SIN.NT Automatic Voltage Regulator for Three-phase Synchronous Generators. (Issued: 04.

WDG 51 - Technical Data Sheet

Power-Tronics, Inc. Electronic Voltage Regulators and Static Exciters P.O. Box , Kerrville, Texas 78029

ADVR-16. Hybrid Universal Analog Digital Voltage Regulator Operation Manual. Self Excited 16 Amp Analog / Digital Voltage Regulator

D510 C A.V.R. Installation and maintenance D 510C W V U X2 Z1 X1 Z2 F+ F- + - L1 L2 U V W. Volt. Exc. Fault. Manu U = U. Power USB +10V - A 1 - A 2 -

Generator Advanced Concepts

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

AGN 124 AVR Power Supplies

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

PM734B - Technical Data Sheet. Generator Solutions AS

PI734C - Technical Data Sheet

R 181 Replacement of the CIN 81

PI734A - Technical Data Sheet

AGN 124 AVR Power Supplies

Low Voltage alternators - 4 pole LSA 47.2

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

Trouble Shooting MagnaPLUS / Mariner / Harsh Duty

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

SERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

D510 c Automatic Voltage Regulators (AVRs)

Your Global Flow Control Partner. Series 70 SERVO PRO Version 3.0 Operation and Maintenance Manual

Rev.8.8 SSRMAN-1P SERIES USERS MANUAL SSR INTELLIGENT PHASE ANGLE CONTROL MODULE COPYRIGHT 2015 NUWAVE TECHNOLOGIES, INC.

TAL 047 Low Voltage Alternator - 4 pole

TAL 049 Low Voltage Alternator - 4 pole

PARTNER ALTERNATORS LSA Pole

TAL 044 Low Voltage Alternator - 4 pole

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY

1. SUMMARY 2. SPECIFICATION 3. WIRING. 3.3 Power Input Voltage Selection. 3.1 A to C: Sensing Input. 3.2 B to C: Power Input

EA06 (220V) Generator Automatic Voltage Regulator Operation Manual

KEY FEATURES. Selectable modes of control : Phase Angle or Burst Fire (Single- Cycle/Dual-Cycle & adjustable STD Burst Firing)

BC145 SIGNAL ISOLATOR BOARD

GX 600 SERIES (AUTOMATIC VOLTAGE REGULATOR)

LSA Pole. R 726 Mains paralleling

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

SRI VIDYA COLLEGE OF ENGG AND TECH

Spec Information. Reactances Per Unit Ohms

GTT 25A - 40A - 60A - 90A - 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL

Operation and Maintenance Manual

M16FA655A - Mark V. User Manual SIN.NT Automatic Voltage Regulator for Three-phase Synchronous Generators

Industrial Systems Design & Implementation

Instruction Manual. Description Calibration. Excitation Sensor and Reverse Power Relay

MASTERFLEX L/S ECONOMY 200 RPM DRIVE 115 VOLT MASTERFLEX L/S ECONOMY 200 RPM DRIVE 230 VOLT

+ 24V 3.3K - 1.5M. figure 01

ADVR-053. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

Excitation Systems. Service Generators SIPOL. Transistorized Excitation Systems for Synchronous Generators. Power Generation

EVC600C User Manual EVC600C SERIES. EVC600C User Manual. Date Version Note. Version. Page 1 of 6. Ver 1.

Low Voltage alternators - 4 pole LSA 46.2

Excitation Systems RG3 - T4. Transistorized Excitation Systems for Synchronous Generators. Power Generation

GENERATOR DATA JANUARY 30, 2015

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

Operating Instructions. for. Controller SMS 150 / 151

X1 Z1 X2 Z2 B+ B- V = IV USB IW PID CAN-H CAN-L PT100/CTP DSP PT100 PT100 A.V.R. AI 1 AI 2 DI1 DI2 D510 C. Installation and maintenance

PARTNER ALTERNATORS LSA 40-4 Pole

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

STEADY STATE REACTANCE

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW

TIG 250 AC-DC. POWER SOURCE art

New Redundant Automatic Voltage Regulator (AVR) Solution

TC1028 series. Thyristor units. Control of single-phase resistive or inductive loads. User manual (300A to 500A rated units)

Transcription:

Droop R2 R1 Q2 Q1 F2 F1 N W V A1 A2 FUSE V AC S UF OE SL UF OE 50 Hz 60 Hz

This manual concerns the alternator AVR which you have just purchased. We wish to draw your attention to the contents of this maintenance manual. SAFETY MEASURES Before using your machine for the first time, it is important to read the whole of this installation and maintenance manual. All necessary operations and interventions on this machine must be performed by a qualified technician. Our technical support service will be pleased to provide any additional information you may require. The various operations described in this manual are accompanied by recommendations or symbols to alert the user to potential risks of accidents. It is vital that you understand and take notice of the following warning symbols. WARNING Warning symbol for an operation capable of damaging or destroying the machine or surrounding equipment. Warning symbol for general danger to personnel. Warning symbol for electrical danger to personnel. All servicing or repair operations performed on the AVR should be undertaken by personnel trained in the commissioning, servicing and maintenance of electrical and mechanical components. When the generator is driven at a frequency below 28 Hz for more than 30 seconds with an analogue AVR, its AC power supply must be disconnected. WARNING This AVR can be incorporated in a ECmarked machine. This manual is to be given to the end user. - We reserve the right to modify the characteristics of this product at any time in order to incorporate the latest technological developments. The information contained in this document may therefore be changed without notice. This document may not be reproduced in any form without prior authorisation. All brands and models have been registered and patents applied for. 2

CONTENTS 1 - GENERAL DESCRIPTION...4 2 - OPERATION OF THE AVR...4 3 - TECHNICAL SPECIFICATION...5 4 - MAIN FUNCTION OF THE AVR...6 5 - AVR SETTINGS...7 5.1 - V-TRIM: V...7 5.2 - FRO: UF...7 5.3 - STAB: S...7 5.4 - EXC LIMIT: OE...7 5.5 - QUADRATURE DROOP...7 5.6 - A1&A2 DC VOLTAGE INPUTS: AC...7 6 - AVR CONTROLS...7 7 - TROUBLESHOOTING CHART...8 8 - MULTIMETER CHECKS...9 9 - STATIC TEST PROCEDURE...10 10 - DIMENSIONS... 11 11 - SPARE PARTS...12 11.1 - Designation...12 11.2 - Technical support service...12 Disposal and recycling instructions 3

1 - GENERAL DESCRIPTION The automatic voltage regulator (AVR) is a compact, high-performance encapsulated unit. It incorporates the latest technology and efficient components to achieve a high degree of miniaturisation when applied to a 3-phase and 1-phase AC brushless generator, within its input and output limits. The unit offers excellent reliability. The AVR provides DC excitation to the exciter field of a brushless generator to keep the voltage within the approximate operating limits from NO-LOAD to FULL LOAD. The typical recovery time in the event of sudden loading is around 0.5 sec. to recover 98% of the rated voltage. Transient performance such as voltage dip and recovery time is mainly determined by the generator and exciter design parameters. Optimum AVR performance can be obtained by keeping full-load excitation to around 60 VDC. The generator uses a true average sensing circuit, dv/dt snubber and special filter circuits to manage NON-LINEAR loads such as battery chargers, DC motors, etc. Voltage regulation is only guaranteed for linear loads. Severely distorting NON- LINEAR loads can cause regulation problems. Each AVR is tested prior to dispatch as part of a quality plan, for standard voltage and frequency. The AVR is provided with two accessory input terminals A1 and A2. Injecting ± 4.5 VDC into these terminals will change the generator voltage by ± 10%. The AVR allows a shunt power supply from the generator output voltage. A soft-start circuit is included which provides smooth control of the build-up of generator output voltage. A frequency roll-off circuit continuously monitors the generator underspeed protection by reducing the generator output voltage in proportion with the speed below a threshold. The AVR has the facility for droop CT connection, which is required for equal KVAR load sharing during parallel operation. 2 - OPERATION OF THE AVR The AVR is powered by the line-to-neutral terminal of the AC generator, with 277 VAC rms at 50 Hz or 60 Hz. The sensing voltage, which is the regulated voltage, is based on line-to-line (for 3-phase) and line-to-neutral (for 1-phase). The AVR forms an important part of the closed loop system comprising the generator field, generator armature and the AVR. The AVR first builds up the generator voltage from its residual levels. When the generator is loaded, the sensed voltage decreases and generates an error voltage, which is required in order for the closed loop system to work. The AVR contains a high gain amplifier, ramp and a pedestal circuit. Depending upon the value of the amplifier voltage (either high or low) the ramp intersects the amplified voltage at a point, which is either early or late in the half-cycle. At this intersection point a starting pulse is produced to trigger the power device. When the power device is triggered early in the half-cycle, more voltage is transmitted to the field and when triggered late in the halfcycle, less voltage is transmitted to the field. In order to reduce the generator voltage at low speed, a signal inversely proportional to the speed is generated as an extra input. At higher speeds the voltage decreases at a faster rate than in proportion with the speed. The AVR has two additional terminals A1 and A2. These inputs can be used to connect an external control signal from controllers such as APFC, Auto Synchronizer, etc. It is important that the DC power supply should be electrically isolated from the line terminals. 4

3 - TECHNICAL SPECIFICATION 1) Sensing input - Voltage: 240 VAC ± 10% for 1-phase, 380 V to 480 VAC ± 10% for 3-phase, 2-line sensing. The AVR senses the true average of the line-to-line waveform. Use the resistor (SMD) network for trouble-free sensing and control of sensed voltage/regulation. 2) Input power - Voltage: 415 V for 3-phase and 240 V for 1-phase - Frequency: 50/60 Hz 3) Output power - Voltage: 105 VDC at 240 VAC input - Current: 6 A DC 8 A for 30 sec. (when allowed by the field resistance) 4) Operating temperature: -20ºC to +70ºC 5) Storage temperature: -40ºC to +80ºC 6) Voltage setting: min ± 10% of rated voltage. 7) Stability setting: can be adjusted to obtain a correct transient response in steady state. 8) 2 to 2.5 kohm external setting potentiometer for 1 Watt to get a voltage setting range of ± 10%. 9) Quadrature droop setting for parallel operation: 4% droop for an output current from the 5 A CT placed on the U phase. 10) Auxiliary inputs A1 and A2: ± 4.5 VDC will change the voltage by ± 10%. 11) Under frequency roll-off setting: available below 46 Hz for 50 Hz and below 56 Hz for 60 Hz. 12) Voltage build-up: 2 V (L-N). 13) Voltage regulation: ± 0.8% at the AVR terminals. 14) Thermal drift: ± 1% for a 30ºC change in temperature. 15) Response time: less than 50 ms. 16) Closed loop response: typically 0.5 sec to recover 98% of the defined voltage for a field forcing ratio of 1:2. 17) Sensing loss protection: the voltage should disappear when the sensing circuit is open. 18) Overexcitation protection: 10 VDC to 85 VDC. Setpoint : 60 VDC. 19) Protection fuse: 6 A, 240 VAC. 20) Potentiometer sealing: except for the V-trim potentiometer, all potentiometers are sealed. 21) Frequency roll-off indicator: LED provided (UF). 22) Sensing loss indicator: LED provided (SL). 23) Overexcitation indicator: LED provided (OE). 24) Protection on the devices: suitable R-C snubber to be provided for the device used to protect against voltage surges. 25) Potting/Encapsulation details: the components on the AVR should be completely encapsulated with suitable PU resin compound to absorb transients/ vibrations during operation. 26) Alternator excitation details: (typical) - Full load: Excitation voltage: 40 to 50 V Excitation current: 2.5 to 5.0 A 27) Terminal marking: see diagram 28) AVR testing: dielectric test, thermal cycling, Static test, voltage variation check, U/F curve, stability check, field excitation limit, external voltage setting check, DC input voltage check. 29) Dimensions: - Overall: 135 x 110 x 47.5 (mm) - Mounting: 115 x 90 (mm) - Mounting hole dia: 9 (mm) 30) Weight: 320 g 5

4 - MAIN FUNCTION OF THE AVR The AVR is powered by the line-to-neutral terminals of the AC generator with 240 VAC at 50/60 Hz. The regulated sensing voltage is based on the generator line-to-line terminals. STATOR: 6 wires (T1 to T6 identification) MAIN FIELD EXCITER T1 U1 T2 V1 T3 W1 Armature Varistor Delta configuration Exciter field + - red or white black or blue 2K/2.5K (1W) 8 7 Rotating rectifiers blue green yellow optional ST1 ST2 Droop R2 R1 Q2 Q1 F2 F1 N W V 8 7 T4 U2 P2 S2 TI04 S1 P1 T5 V2 Star configuration T6 W2 Options: Q1 and Q2: CT for parallel operation TI04 (remove ST2) R1 and R2: 2/2.5 kohm external potentiometer (remove ST1) A1 and A2: isolated voltage ± 4.5 VDC A1 A2 FUSE V AC S UF OE SL UFOE 50 Hz 60 Hz Depending upon the value of the amplified voltage, the ramp intersects the amplified voltage at a point which is early or late in the half-cycle. At this intersection point, a starting pulse is produced to trigger the power device. The AVR builds up the generator voltage from its residual voltage to rated voltage. When the generator is loaded, the sensed voltage decreases and generates an error signal, which is required in order for the closed loop system to work. Only qualified personnel should replace/ work on the AVR. Do not increase the voltage beyond the rated voltage. 6

5 - AVR SETTINGS 5.1 - V-TRIM: V This function is provided for setting the voltage up to ± 12% of rated voltage by means of a potentiometer. Turn the potentiometer clockwise to increase the voltage and vice versa, once the rated speed has been reached. It is also possible to connect an external potentiometer. 5.2 - UF - Under frequency knee point setting This function is provided to protect the AC generator from sustained low speed operation through a potentiometer. The AVR will reduce the voltage in proportion with the speed below the defined value. The procedure for setting the UF potentiometer is as follows: First run the generator at full speed (50 Hz) and turn the UF potentiometer by a few turns clockwise, making sure that the voltage does not increase. Now turn the UF potentiometer slowly anticlockwise. At a particular point the red LED glows and the voltage will start to decrease. Stop turning the potentiometer at this point and turn the potentiometer clockwise by two turns after rated voltage is restored. The factory default setting is 46 Hz. For 60 Hz operation, the knee point position is set to 56 Hz. 5.3 - STAB: S This function is provided to stop voltage hunting by means of a potentiometer. Turn clockwise to increase stability (to stop oscillation). Turning too far clockwise will result in a sluggish response and possibly also oscillations. The factory default setting is slightly higher than critical damping (around halfway). 5.4 - EXC LIMIT: OE This function is provided to protect the Exciter Field from overexciting by turning a potentiometer clockwise to increase the excitation limit. It is factory-set at 105 V. The red LED lights up when the ceiling has been reached for more than 10 s. 5.5 - QUADRATURE DROOP This potentiometer is used to adjust the voltage droop to balance the reactive load in parallel operation. Follow the instructions for connecting the CT (current transformer) which is essential for this function, as per the AVR connection diagram. Turn the potentiometer clockwise to increase % droop and vice versa. 5.6 - A1&A2 DC VOLTAGE INPUTS: AC These accessory terminals A1 and A2 are used to inject ± 1.0 to 4.5 VDC. The variation in terminal voltage will be ± 10% of the rated voltage. Warning: A Vishay spectrol model 8 type screwdriver should be used to adjust the potentiometer. 6 - AVR CONTROLS No. Control Function Direction V VOLTS Sets the generator output voltage Turn clockwise to increase output voltage UF UFRO Sets the Under frequency knee point Turn clockwise to reduce the knee point S STAB Stops voltage hunting Turn clockwise to increase stability OE OVER EXC Sets the overexcitation limit Turn clockwise to increase the limit DROOP DROOP Sets voltage droop Turn clockwise to increase the droop AC ACC (DC i/p) Used for Auto synchronization Turn clockwise to increase the gain 7

7 - TROUBLESHOOTING CHART Symptom Cause Action No voltage build-up Fuse blown Low residual voltage across U and N terminals Check and replace If the generator s residual voltage at rated speed is less than 2.5 VAC (L-N), disconnect the AVR and connect a 24 VDC battery, keeping F1 as positive and F2 as negative. Connecting a freewheel diode (BY 127) across the field with the diode cathode to F1 and the anode to F2 during field flashing will help restore the residual voltage. WARNING: Remove the diode (BY-127) after field flashing. The 24 V battery positive terminal must only be connected to F1 and the negative to F2. Swapping the connection will cause diode BY127 to explode instantly. High voltage build-up Low voltage build-up Voltage oscillation Incorrect regulation Incorrect wiring Rotating diodes and/or fuse failed Voltmeter on the front defective AVR defective (repeated fuse blowing) Earthed exciter field Loose or missing connection to AVR U terminal AVR defective Low prime mover speed Sensing loss in circuit AVR defective Incorrect stability potentiometer sealing Prime mover speed hunting Load hunting, fluctuates rapidly High percentage of non-linear loads High reactance in generator (during non-linear loading) The exciter field s requirement is higher than 105 VDC Check wiring Check and replace Check and correct Replace after performing a static test Check and correct Check and correct Perform a static test and replace if necessary Check and correct Check and correct Replace the AVR Turn clockwise until hunting stops Check and adjust the controller Check and correct Check and reduce the non-linear load Consult the generator manufacturer Wrong selection or very low P.F. load. Check and correct. Prime mover speed drops too much when on load (kw load) Adjust the controller and reduce the active load 8

8 - MULTIMETER CHECKS Equipment: Digital multimeter. Select Diode mode on the digital multimeter. The resistance between F1 and F2 (with the multimeter jack common applied to F1 of the AVR) should be between 0.4 and 0.6 V, and vice versa (with the multimeter jack common applied to F2 of the AVR) should give INFINITY. ZERO indicates a power device failure in both cases. No further tests (static or dynamic) are allowed, as they would lead to the fuse blowing. The resistance between F2 and U (both sides) should be 180 kw. The resistance between F2 and V (with the multimeter jack common applied to the AVR V terminal should be approximately 2. 2 MW in the 10 MW range and vice versa (with the multimeter jack common applied to the AVR F2 terminal) should be 15 MW. ZERO indicates power device failure in both cases. No further tests (static test or dynamic tests) are allowed, as they would to the fuse blowing. The resistance between U and V should be 300 kw to 400 kw. Open circuit indicates AVR failure. During a static test the lamp will not turn OFF or, when connected to the generator it will produce ceiling voltage (for 3-phase ONLY). The resistance between U and N1 should be between 200 kw and 260 kw. Open circuit indicates AVR failure. During a static test, the lamp will not turn OFF or, when connected to the generator, it will produce a ceiling voltage (for 1-phase ONLY). The resistance between N and F1 should be very low or ZERO ohms. If the circuit is open, the lamp will not glow when the static test is performed. 9

9 - STATIC TEST PROCEDURE For 3-phase circuit AVR (3-PH) Model: F2 F1 N W V VAC 0-500 V F1 R LAMP 100 W 230 V F2 F3 Y B 415 V, 3Ø, 50 Hz, WITH NEUTRAL N VARIAC 8 A, 415 V STATIC TEST CONNECTION DIAGRAM OF 3-PH AVR This test should only be attempted after making sure that the AVR has passed all multimeter checks. Connect the AVR to the three-phase variable voltage source as shown in diagram for 3-phase installation in this manual. 1. Keep V-TRIM in the minimum position. 2. Keep UF in the fully maximum position. 3. Increase the applied voltage. The lamp should glow increasingly brightly. At a voltage of around 360-380 V. The lamp should go out slowly. Increase the voltage again up to 415 V. The lamp should stay OFF. Decrease the voltage to below 360 V. The lamp should glow brightly again. 4. Turn the UF potentiometer anticlockwise; the lamp should go out slowly. Now turn the UF potentiometer clockwise. The lamp should glow brightly again. 5. It is difficult to prescribe a static test for checking the stability, as this is more easily detected during closed loop tests. However, a healthy AVR will behave as described below. First keep the STAB potentiometer in the fully anticlockwise position. Perform the static test as described in steps 1, 2 and 3. The lamp will go out fairly quickly at 360-380 V and come on again quickly when the voltage is reduced to below 360 V. Now keep the STAB potentiometer fully clockwise, and perform the static test as in 1, 2, and 3. The lamp should go out much more slowly and come on again much more slowly. At the end of this test reset the potentiometer in the middle position. If the AVR behaves as described above then the regulator is healthy. 10

10 - DIMENSIONS 135 mm 110 mm A1 A2 V AC S UF OE SL UF OE Droop R2 R1 Q2 Q1 F2 F1 N W V FUSE 90 mm 10 50 Hz 60 Hz 10 115 mm 11

11 - SPARE PARTS 11.1 - Designation Description Type Code AVR 5014127 11.2 - Technical support service Our technical support service will be pleased to provide any additional information you may require. For all spare parts orders or technical support requests, send your request to service.epg@leroy-somer.com or your closest contact, whom you will find at www.lrsm.co/support indicating the type and the code number of the AVR. To ensure that our products operate correctly and safely, we recommend the use of original manufacturer spare parts. In the event of failure to comply with this advice, the manufacturer cannot be held responsible for any damage. 12

Disposal and recycling instructions We are committed limiting the environmental impact of our activity. We continuously monitor our production processes, material sourcing and products design to improve recyclability and minimise our environmental footprint. These instructions are for information purposes only. It is the user s responsibility to comply with local legislation regarding product disposal and recycling. Waste & hazardous materials The following components and materials require special treatment and must be separated from the alternator before the recycling process: - electronic materials found in the terminal box, including the automatic voltage regulator (198), current transformers (176), interference suppression module (199) and other semi-conductors. - diode bridge (343) and surge suppressor (347), found on the alternator rotor. - major plastic components, such as the terminal box structure on some products. These components are usually marked with information concerning the type of plastic. 13

14

Service & Support Our worldwide service network of over 80 facilities is at your service. This local presence is our guarantee for fast and efficient repair, support and maintenance services. Trust your alternator maintenance and support to electric power generation experts. Our field personnel are 100% qualified and fully trained to operate in all environments and on all machine types. We have a deep understanding of alternator operation, providing the best value service to optimise your cost of ownership. Where we can help: Design Consulting & specification Maintenance contracts Life Extension Reconditioning System upgrade Start-up Commissioning Training Optimisation Monitoring System audit Operation Genuine spare parts Repair services Contact us: Americas: +1 (507) 625 4011 Europe & Rest of the world: +33 238 609 908 Asia Pacific: +65 6250 8488 China: +86 591 88373036 India: +91 806 726 4867 Middle East: +971 4 811 8483 service.epg@leroy-somer.com Scan the code or go to: www.lrsm.co/support

www.leroy-somer.com/epg Linkedin.com/company/Leroy-Somer Twitter.com/Leroy_Somer_en Facebook.com/LeroySomer.Nidec.en YouTube.com/LeroySomerOfficiel