Industrial Serie +600S

Similar documents
NEVO+1200M. 6 x6 x W. 1.2kg DATA SHEET MAIN FEATURES

Voltage Adjustment. Load Regulation

(*) Reference the User Manual or contact the factory for parallel operation between modules plugged into slots 1/2/3/4 and slots 5/6/7/8.

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

General. Environmental. EMC & Safety

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

LB115S 115W Single Output

solo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2 FEATURES APPLICATIONS INCLUDE

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

General. Environmental. EMC & Safety

LFWLP W 12V 15.00A 25.00A 92%

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

Electrical Specifications

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

NFF Series. CoolX600 NFF Series Cool. Patent Pending Resonant Technology. NFF Series; No Fan Featured

C B. Models. Models 2MOPP

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

TB65 65W Single Output Test and Measurement/Industrial Series

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

IP67 DESCRIPTION KEY FEATURES MARKET SEGMENT AND APPLICATIONS TRC ELECTRONICS, INC

TE60 60W Single Output External Power Test & Measurement/Industrial Series

Electrical Specifications

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

Output Voltage* (nom.)(adjustable)

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

50W Constant Current (700mA) Dimming LED Driver

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

150 Watt Industrial (WLT)

VCCM600S INDUSTRIAL AC/DC CONDUCTION COOLED CONFIGURABLE POWER SUPPLY

18093-PS PHIHONG TECHNOLOGY CO., LTD. General Specification PSM (DC)

Medical / Industrial AC-DC Power Supply 1200W with 5V/2A Standby / MEB-1K2A series

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

TE60 60W Single Output External Power Test & Measurement/Industrial Series

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

IEC/EN/UL60950 & CE certified, EN55032 Class B

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

TE W Single Output External Power Test & Measurement/Industrial Series

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

DDP400 and MDP400, SC series, are sealed, full potted, compact, high efficiency, small form factor AC-DC power supplies.

300µA max at 264Vac & 63Hz (normal condition, 500µA Single Fault Condition) Adjustment Range V V. Channel

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

CCH400 & CCH600 Series

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

CB Scheme UL508 UL ATEX II3G

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Doc. EA Model Number:

Output Power (W) Industry Leading Performance. Fuse

CoolX CoolPac. CoolPac Slots Power. CoolX CoolMod. Vnom (V) CoolModel. Single Output Modules (1 Slot) High Power Modules (3 Slot)

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

75W Constant Current (700mA) LED Driver

Cool. NFF Series. CoolX600 NFF Series. Patented Resonant Technology. NFF Series; No Fan Featured

DDP400 SERIES KEY FEATURES DESCRIPTION MARKET SEGMENTS AND APPLICATIONS

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

Low Profile. 3 Year Warranty

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

Features. Regulated Converter. RAC10-K/ Watt 2 x 1 Single and Dual Output RAC10- K/277. AC/DC Converter

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

Parameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

VOF XX - XXX - X

Output Voltage (Vfan) & Current

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

HEC-45LTN-45PFAS Rev A

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

TE90 90W Single Output External Power Test & Measurement/Industrial Series

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

08/07/2015

MB120S 120W Single Output Medical Series

Transcription:

D A T A S H E E T Industrial Serie +6S Modular Configurable Reduced fan noise Enhanced Line Derating 6 watts in the palm of your hand The +6S series fetures improved low input line derating delivers 6 watts without the need to derate for line voltages above 12Vac making the +6S the ultimate power solution for products destined for the global market. Through the implementation of a fan control circuit the +6S also features reduced fan noise. The +6S delivers up to 6 watts from a 6 gram 5 x 3 x 1U package and consists of an input module together with up to four isolated output modules. The series carry full UL695 safety approvals and comply with EN61 3, EN61 4 and EN5522 B EMC standards. MAIN FEATURES: No Line derating above 12VAC Reduced fan noise High reliability High efficiency up to 89% 6 watt output Only.6kg 1W/kg RoHS compliant 5 x 3 x 1U footprint I 2 C control option Field configurable Accurate current sharing 5V 2mA bias supply High power density (25W/in 3 ) Remote current/voltage programming Two year warranty Industrial approvals Current output signal SYSTEM SPECIFICATIONS INPUT ELECTRICAL AC Input Voltage Nominal range is 1Vrms to 24Vrms 85 264 Vrms AC Input Frequency Contact factory for 4Hz 5/ 47 operation. 6 63 Hz DC Input Voltage Standard 12 37 Vdc Power Rating See graphs for deratings 6 Watts Input Current 6Watts output at 12Vrms input 6 Amps Inrush Current 265Vrms (cold start) 2 Amps Fusing 5x2 Fast acting 8 Amps Input Current Limit Maintains power factor 8 Amps Efficiency See graphs 86 89 % Idle Power All outputs fitted and enabled 28 Watts Idle Power All outputs fitted and Disabled 21 Watts Power Factor Typical value for 3Watts output at 24Vrms input.96.99 Holdup 6Watts output at 12Vrms input 17 2 21 ms UVLO Turn on only 78 84 Vrms Over temperature Internally monitored. Reliability 4 C 8% load 2 FPMH S i g n a l s Bias Voltage 4.8 5 5.2 V Bias current 2 ma Power Good PNP open collector with internal voltage 1k pull down resistor 8 1 15 V Power Good current 2 ma Inhibit voltage 2 15 V Inhibit current 1k ohm input impedance.2 1.5 ma Global inhibit voltage 3 15 V Global inhibit current 5k ohm input impedance.6 3 ma AC_OK voltage 1 4 V AC_OK current 1 2 ma AC_OK warning See user manual for exceptions 5 ms INSTALLATION Parameter Details Parameter Details Equipment class I Flammability rating 94V 2 Installation category II IP Rating IP1 Pollution degree 2 ROHS Compliance 22/95/EC Material group IIIb (indoor use only) RELIABILITY Component Details Min Max Units FAN Mag Lev Std 2.7 FPMH INPUT Excluding FAN 2 FPMH OUTPUT See individual output datasheets 1 FPMH SAFETY Parameter Details Min Max Units Input to Output 4 Vac Isolation Input to Chassis 15 Vac Voltage Output to Chassis 25 Vdc Output to Output 25 Vdc Isolation Clearance Isolation Creepage Primary to Secondary (Reinforced) 7 mm Primary to Chassis (Basic) 2.5 mm Primary to Secondary (Reinforced) 12 mm Primary to Chassis (Basic) 4 mm Leakage Current Standard: 265Vac, 63Hz, 25 C 15 ua Parameter Weight Mounting MECHANICAL Details 77.7mm x 133.7mm x 41.mm (all external dimensions ± 1.mm) 36 gram +6 gram per output module Bottom or Side mounting (See diagram for details)

Industrial Serie +6S S t o r a g e O p e r a t i o n ENVIRONMENTAL Parameter Details Min Max Units 4 +85 C Humidity Relative, non condensing 5 95 % Altitude 2 5 m Air Pressure 54 16 kpa Full power 2 5 C Derate input and outputs at 2.5%/ C 5 7 C Humidity Relative, non condensing 5 95 % Altitude ( 2 to 2m for UL661 1) 2 3 m Air Pressure 78 16 kpa Noise Level Shock Vibration Variable. Measured 1m from fan intake 3 bumps at 1G (16ms) half sine wave 36 6 dba 1.5G 1 to 2Hz sine wave, 2G for 15min in 3 axes random vibration AGENCY APPROVALS Standard Details Standard Details IEC/EN695 1 UL695 1 CSA C22.2 No. 695 1 3 CE MARK LVD 73/23/EEC UL file number UL: E316486 CB certificate and report available on request Emissions Immunity EMC Parameter Standard Level Radiated electric field EN5511, EN5522, FCC B Conducted emissions EN5511, EN5522, FCC B Harmonic Distortion EN61 3 2 Compliant Flicker & Fluctuation EN61 3 3 Compliant Electrostatic discharge EN61 4 2 (15kV air, 8kV contact) 4 Radiated RFI EN61 4 3 (1V/m) 3 Fast Transient burst EN61 4 4 (4kV) 4 Input line surges EN61 4 5 (1kV L N, 2kV L E) 3 Conducted RFI EN61 4 6 (1V) 4 Power Freq. Magnetic Field EN61 4 8 (1A/m) 3 Voltage Dips EN61 4 11 (EN5524) Compliant Efficiency.9.85.8.75.7 Typical Load Efficiency OP2-22V OP1-22V OP3-22V 5 15 25 35 45 55 65 Watts Out Efficiency.9.89.88.87.86.85.84.83.82.81.8 Typical Line Efficiency OP1-4W OP2-4W OP3-4W OP1-5Wout OP2-6Wout OP3-6Wout 1 12 14 16 18 2 22 24 26 RMS input Voltage Power out 65 6 55 5 45 4 35 3 25 Line Derating 8 1 12 14 16 18 2 22 24 26 Vinrms Power out 65 6 55 5 45 4 35 3 25 Derating -3-1 1 3 5 7 9

Industrial Serie +6S MECHANICAL DIMENSIONS AND MOUNTING SCREWS SCREWS MH1, MH2, MH3, MH4, MH5 Screw type M4 Tightening Tighten to 1.5 Nm Penetration depth 4.mm max including chassis OUTPUT MODULES x 8 Screw type M3x5, C/Sink, Posi, Stainless Steel Tightening Tighten to.75 Nm Penetration depth Defined by screw CHASSIS x 5 Screw type M3x5, C/Sink, Posi, Stainless Steel Tightening Tighten to.75 Nm Penetration depth Defined by screw FAN x 2 Screw type M3x24, C/Sink, Posi, Stainless Steel Tightening Tighten to.75 Nm Penetration depth Defined by screw

Industrial Serie +6S Circuit 1 Live 2 Earth 3 Neutral Circuit 1 Power Good PINOUTS J1 Details J2 Details Slot A J1 CONNECTORS 2 Inhibit 3 Power Good Slot B 4 Inhibit 5 Power Good Slot C 6 Inhibit 7 Power Good Slot D 8 Inhibit 9 Global Inhibit 1 AC OK 11 +5V 2mA Bias Supply 12 COM J5 J3 Circuit Details Positive Output 1 Sense J4 2 +Sense Negative Output 3 Voltage Control 4 Current Control / Share / Out 5 COM 6 +5V local bias supply REF. DETAILS MANUFACTURER TERMINAL J1 MAINS INPUT: 3 Pin, 5.8mm, with Friction Lock, 18 24 AWG MOLEX 87131 J2 GLOBAL SIGNALS: 12 Pin, 2mm, with Friction Lock, 24 3 AWG MOLEX 5394851 J2 IDT ALTERNATIVE FOR J2 MOLEX N/A J3/4(1) OUTPUT POWER TERMINAL: TAB SIZE 6.35mmx.8mm VARIOUS N/A J5 OUTPUT SIGNALS: 6 Pin, 1.25mm, with Friction lock, 28 32 AWG MOLEX 151216 5588 Notes 1. Terminal and Wire current rating must exceed maximum short circuit output current. Eg. Output 1 = 25A*1.25 = 31.25Amps 2. Direct equivalents may be used for any connector parts 3. All cables must be rated 15 C min, equivalent to UL115 PART NUMBERING SYSTEM NEVO+ Power series NEVO+ 6 S 1 1 2 3 Factory Use Leakage Current S Standard Use for unused slots. Blanking plates will be inserted at factory Slot A Output # Slot D Output # Slot B Output # Slot C Output # When initially ordering non nominal voltage settings add /Voltage after each output # where a special voltage setting is required E.g. If 3.3Vdc is required in slot B and all other slots require nominal voltages then use: NEVO+ 6S 1 1/3.3 2 3 The factory will then issue a 3 digit code for your specific configuration that can be used for all future orders of the same configuration When ordering an input unit with no outputs inserted, simply order + 6S

OP1 module 125W Output voltage range 1,5V-7,5V 25A OUTPUT 1 SPECIFICATIONS Output voltage range See table 1.5 5 7.5 V Rated current 25 A Average output power 125 Watts Peak output power See graph, < 5 seconds 5% duty cycle 187.5 Watts Initial voltage accuracy Factory set units.5.5 % Manual Voltage Adjust 11 turn potentiometer.545 V/turn Load Regulation Measured at sense terminals 5 5 mv Line Regulation Measured at sense terminals.1.1 %Vnom Cross Regulation Measured at sense terminals.2.2 %Vnom Minimum Load Watts coefficient.2.2 %/ C Ripple and Noise 2MHz BW, pk pk 1 %Vnom 1A/us 1 V Recovery to within 1% of 1 us Turn on rise time Monotonic 1% to 9% 1.5 3.5 ms Turn on overshoot.1 % AC to PG 6 75 ms En to PG 15 2 ms Current share accuracy 5 %Imax Open sense offset Open sense, voltage offset due to bias currents 2 %Vnom Holdup voltage 6 V Isolation to ground Each terminal 25 V % of rated current 15 125 %rated % of rated current 6 %rated (Hiccup mode) Period 125 ms Duty cycle 3 % Voltage threshold (Measured at sense terminals) 1 V 9.5 V Over Internally monitored. Sense cable Positive 1 2 V Negative 1 V Power Good threshold Low threshold only 9 % Current output signal I SIG =.6+I OUT /(I RTD *1.25) 11 %Irated Current limit control I LMT = (V CTRL.6)*I RTD *1.25 11 %Irated Remote voltage control V OUT =V SET ((1.8 V CTRL )/.6) 3 % Bias supply 1mA max 4.5 5 5.2 V Reliability 4 C 8% load 1 FPMH Wire 12 1 AWG Weight 6 Grams 6mm x 35mm x 17mm 1 9 8 7 6 5 4 3 2 Manual trim range OUTPUT 1 POWER PROFILE CONTINIOUS POWER OVP Peak power 1 HICCUP 5 1 15 2 25 3 Amps RIPPLE.2.15.1.5 -.5 -.1 -.15 -.2 2 4 6 8 1 12 14 16 18 2 us 125W OCP

OP2 module 15W Output voltage range 4,5V-15V 15A OUTPUT 2 SPECIFICATIONS Output voltage range See table 4.5 12 15 V Rated current 15 A Average output power 15 Watts Peak output power See graph, < 5 seconds 5% duty cycle 225 Watts Initial voltage accuracy Factory set units.5.5 % Manual Voltage Adjust 11 turn potentiometer.954 V/turn Load Regulation Measured at sense terminals 1 1 mv Line Regulation Measured at sense terminals.1.1 %Vnom Cross Regulation Measured at sense terminals.2.2 %Vnom Minimum Load Watts coefficient.2.2 %/ C Ripple and Noise 2MHz BW, pk pk 1 %Vnom.5A/uS 1.5 V Recovery to within 1% of 1 us Turn on rise time Monotonic 1% to 9% 1.5 3.5 ms Turn on overshoot.1 % AC to PG 6 75 ms En to PG 15 2 ms Current share accuracy 5 %Imax Open sense offset Open sense, voltage offset due to bias currents 2 %Vnom Holdup voltage 12.5 V Isolation to ground Each terminal 25 V % of rated current 15 125 %rated % of rated current 6 %rated (Hiccup mode) Period 125 ms Duty cycle 3 % Voltage threshold (Measured at sense terminals) 2 V 18 V Over Internally monitored. Sense cable Positive 1 2 V Negative 1 V Power Good threshold Low threshold only 9 % Current output signal I SIG =.6+I OUT /(I RTD *1.25) 11 %Irated Current limit control I LMT = (V CTRL.6)*I RTD *1.25 11 %Irated Remote voltage control V OUT =V SET ((1.8 V CTRL )/.6) 3 % Bias supply 1mA max 4.5 5 5.2 V Reliability 4 C 8% load 1 FPMH Wire 16 14 1 AWG Weight 6 Grams 6mm x 35mm x 17mm 2 18 16 14 12 1 8 6 Manual trim range OUTPUT 2 POWER PROFILE CONTINIOUS POWER OVP Peak power 4 2 HICCUP 2 4 6 8 1 12 14 16 18 Amps 15W TRANSIENT RESPONSE 1.5.75 2 -.75 15-1.5 1-2.25-3 5-3.75-4.5 -.75 -.55 -.35 -.15.5.25 ms RIPPLE.4.3.2.1 -.1 -.2 -.3 -.4-1 -8-6 -4-2 2 4 6 8 1 us OCP Amps

OP3 module 15W output range 9V- 3V 7,5A OUTPUT 3 SPECIFICATIONS Output voltage range See table 9 24 3 V Rated current 7.5 A Average output power 15 Watts Peak output power See graph, < 5 seconds 5% duty cycle 225 Watts Initial voltage accuracy Factory set units.5.5 % Manual Voltage Adjust 11 turn potentiometer 1.9 V/turn Load Regulation Measured at sense terminals 15 15 mv Line Regulation Measured at sense terminals.1.1 %Vnom Cross Regulation Measured at sense terminals.2.2 %Vnom Minimum Load Watts %/ C.2.2 coefficient Ripple and Noise 2MHz BW, pk pk 1 %Vnom.25A/uS 3 V Recovery to within 1% of 1 us Turn on rise time Monotonic 1% to 9% 1.5 3.5 ms Turn on overshoot.1 % AC to PG 6 75 ms En to PG 15 2 ms Current share accuracy 5 %Imax Open sense offset Open sense, voltage offset due to bias currents 2 %Vnom Holdup voltage 25 V Isolation to ground Each terminal 25 V % of rated current 15 125 %rated % of rated current 6 %rated (Hiccup mode) Period 125 ms Duty cycle 3 % Voltage threshold (Measured at sense terminals) 3.5 V 36 V Over Internally monitored. Sense cable Positive 1 2 V Negative 1 V Power Good threshold Low threshold only 9 % Current output signal I SIG =.6+I OUT /(I RTD *1.25) 11 %Irated Current limit control I LMT = (V CTRL.6)*I RTD *1.25 11 %Irated Remote voltage control V OUT =V SET ((1.8 V CTRL )/.6) 3 % Bias supply 1mA max 4.5 5 5.2 V Reliability 4 C 8% load 1 FPMH Wire 2 18 1 AWG Weight 6 Grams 6mm x 35mm x 17mm 4 35 3 25 2 15 1 Manual trim range OUTPUT 3 POWER PROFILE CONTINIOUS POWER OVP Peak power 5 HICCUP 1 2 3 4 5 6 7 8 9 Amps 15W TRANSIENT RESPONSE 3 12 1.5 1 8-1.5-3 6-4.5 4-6 2-7.5-9 -.75 -.55 -.35 -.15.5.25 ms RIPPLE.5.4.3.2.1 -.1 -.2 -.3 -.4 -.5-1 -8-6 -4-2 2 4 6 8 1 us OCP Amps

OP4 module 15W Output voltage range 18V-58V 3,75A OUTPUT 4 SPECIFICATIONS Output voltage range See table 18 48 58 V Rated current 3.75 A Average output power 15 Watts Peak output power See graph, < 5 seconds 5% duty cycle 225 Watts Initial voltage accuracy Factory set units.5.5 % Manual Voltage Adjust 11 turn potentiometer 3.6 V/turn Load Regulation Measured at sense terminals 3 3 mv Line Regulation Measured at sense terminals.1.1 %Vnom Cross Regulation Measured at sense terminals.2.2 %Vnom Minimum Load Watts %/ C.2.2 coefficient Ripple and Noise 2MHz BW, pk pk 1 %Vnom.25A/uS 3 V Recovery to within 1% of 1 us Turn on rise time Monotonic 1% to 9% 1.5 3.5 ms Turn on overshoot.1 % AC to PG 6 75 ms En to PG 15 2 ms Current share accuracy 5 %Imax Open sense offset Open sense, voltage offset due to bias currents 2 %Vnom Holdup voltage 5 V Isolation to ground Each terminal 25 V % of rated current 15 125 %rated % of rated current 6 %rated (Hiccup mode) Period 125 ms Duty cycle 3 % Voltage threshold (Measured at sense terminals) 3.5 V 66 V Over Internally monitored. Sense cable Positive 3 3 V Negative 2 V Power Good threshold Low threshold only 9 % Current output signal I SIG =.6+I OUT /(I RTD *1.25) 11 %Irated Current limit control I LMT = (V CTRL.6)*I RTD *1.25 11 %Irated Remote voltage control V OUT =V SET ((1.8 V CTRL )/.6) 3 % Bias supply 1mA max 4.5 5 5.2 V Reliability 4 C 8% load 1 FPMH Wire 2 18 1 AWG Weight 6 Grams 6mm x 35mm x 17mm

OP5 module 15W Dual output voltage range 5V-15V 5A OUTPUT 5 SPECIFICATIONS Output voltage range Each channel 5 12 15 V Rated current Each channel 5 A Average output power Each channel 75 Watts Initial voltage accuracy Factory set units 1 1 % Manual Voltage Adjust 11 turn potentiometer.9 V/turn Load Regulation Measured at terminals 5 5 mv Line Regulation Measured at terminals.1.1 %Vnom Cross Regulation Measured at terminals.2.2 %Vnom Minimum Load Watts coefficient.2.2 %/ C Ripple and Noise 2MHz BW, pk pk 15 mv.5a/us 1 V Recovery to within 1% of 1 us Turn on rise time Monotonic 1% to 9% 1.5 3.5 ms Turn on overshoot.1 % AC to PG 6 75 ms En to PG 15 2 ms Holdup voltage 12 V Isolation to ground Each terminal 25 V % of rated current 11 15 %rated None Period 125 ms Duty cycle 3 % (Hiccup mode) 2 V Over Internally monitored. Power Good threshold Low threshold only 9 % Reliability 4 C 8% load 1 FPMH Wire 2 18 1 AWG Weight 6 Grams 6mm x 35mm x 17mm REF. DETAILS MANUFACTURER HOUSING TERMINAL J1 OUTPUT POWER CONNECTOR: 4 Pin, with Friction lock, 2 24 AWG MOLEX 43254 4331 Notes: 1. Terminal and Wire current rating must exceed maximum output current. 2. Direct equivalents may be used for any connector parts 3. All cables must be rated 15 C min, equivalent to UL115

OP6 module 5W Dual output voltage range 1,8V-5V 5A OUTPUT 6 SPECIFICATIONS Output voltage range Each channel 1.8 3.3 5 V Rated current Each channel 5 A Average output power Each channel 16.5 25 Watts Initial voltage accuracy Factory set units 1 1 % Manual Voltage Adjust 11 turn potentiometer.3 V/turn Load Regulation Measured at sense terminals 5 5 mv Line Regulation Measured at sense terminals.1.1 % Cross Regulation Measured at sense terminals.2.2 % Minimum Load Watts drift 2 C to +5 C.2.2 %/ C Ripple and Noise 2MHz BW, pk pk 2 % 1A/uS.5 V ( = 3.3V) Recovery to within 1% of 1 us Turn on rise time Monotonic 1% to 9% 1 3.5 ms Turn on overshoot.1 % AC to PG 6 75 ms En to PG 15 2 ms Holdup voltage 5 V Isolation to ground Each terminal 25 V % of rated current 15 13 %rated None Period 3 ms Duty cycle 1 % (Hiccup mode) 8 V Over Internally monitored. Power Good threshold High and low window 68 12 % Reliability 25 C 1% load Telcordia 1 FPMH Wire 24 22 2 AWG Weight 6 Grams 6mm x 35mm x 17mm REF. DETAILS MANUFACTURER HOUSING TERMINAL J1 OUTPUT POWER CONNECTOR: 4 Pin, with Friction lock, 2 24 AWG MOLEX 43254 4331 Notes: 1. Terminal and Wire current rating must exceed maximum output current. 2. Direct equivalents may be used for any connector parts 3. All cables must be rated 15 C min, equivalent to UL115

OUTPUT 7 SPECIFICATIONS Output voltage range Top/Bottom channel 1.8/5 3.3/12 5/15 V Rated current Each channel 5 A Average output power Top/Bottom channel 6/16.5 75/25 Watts Initial voltage accuracy Factory set units 1 1 % Manual Voltage Adjust 11 turn potentiometer.3/.9 V/turn Load Regulation Measured at sense terminals 5 5 mv Line Regulation Measured at sense terminals.1.1 % Cross Regulation Measured at sense terminals.2.2 % Minimum Load Watts drift 2 C to +5 C.2.2 %/ C Ripple and Noise 2MHz BW, pk pk 2 % 1A per us 1/.5 V ( = 5V/3.3V) Recovery to within 1% of 1/1 us Turn on rise time Monotonic 1% to 9% 1 3.5 ms Turn on overshoot.1 % AC to PG 6 75 ms En to PG 15 2 ms Holdup voltage Top/Bottom channel 12/5 V Isolation to ground Each terminal 25 V % of rated current 15 13 %rated None Period 3 ms (Hiccup mode) Duty cycle 1 % Top/Bottom channel 2/8 V Over Internally monitored. Power Good threshold High and low window 68 12 % Reliability 25 C 1% load Telcordia 1 FPMH Wire 24 22 2 AWG Weight 6 Grams 6mm x 35mm x 17mm REF. DETAILS MANUFACTURER HOUSING TERMINAL J1 OUTPUT POWER CONNECTOR: 4 Pin, with Friction lock, 2 24 AWG MOLEX 43254 4331 Notes: 1. Terminal and Wire current rating must exceed maximum output current. 2. Direct equivalents may be used for any connector parts 3. All cables must be rated 15 C min, equivalent to UL115