Paper Towel, Toilet Paper, Soap and Hand Sanitizer Dispensers

Similar documents
ACCESSIBILITY DETAILS FOR RESTROOMS AND DRINKING FOUNTAINS

WEST HOLLYWOOD ACCESSIBLE UNISEX BATHROOMS: COMMERCIAL CLEARANCES. Accessible Unisex Bathrooms: Commercial Page 1 of 5

Priority 3 - Toilet Rooms

2016 CALIFORNIA BUILDING CODE - SECTION 11B-213 & DIVISION 6 GENERAL REQUIREMENTS FOR TOILET & BATHING FACILITIES

Priority 3 - Toilet Rooms

Accessible Toilet Stalls 6/18/03 1

ACCESSIBILITY REQUIREMENTS FOR SINKS

KEYS TO COMPLIANCE ASSEMBLY AND MERCANTILE OCCUPANCIES ACCESSIBLE TOILET COMPARTMENTS. Figure 16 Handrail cross section {505.7}

WALKS AND SIDEWALKS REQUIREMENTS:

NCIDQ Restroom Drawing. Answers to the most common questions about this drawing for the Practicum Qpractice

A.1 KING RESTROOM DEMOLITION PLAN. KING PARK 725 Monte Diablo Ave, San Mateo, CA LEGEND A.2 4 SCALE:

atm installation for accessibility a guide to ada/aba accessibility guidelines

REAR FRONT 93' 20' 12' 48' 120' 30' 52' 75' Sample Shopping Center. Unit # 5 +/- 10,920 GLA GROUND FLOOR. Width +/- 105' Depth +/- 120' Site Map

CKBD Peakes Bath Scoresheet

grab BarS and rails 800 SerieS

ADA Barrier-Free Bathware for Assisted Living

404 Doors, Doorways, and Gates

TOILET ROOM ACCESSORIES Concrete Unit Masonry Carpentry Ceramic Tile Solid Plastic Toilet Partition.

The following information supplements and/or supersedes the bid documents issued on July 10, 2017.

Kitchen and Bath Design Planner

***************************************************************************************************************

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

A. It is preferred that all submittals to be submitted electronically in PDF format.

Americans with Disabilities Act and Architectural Barriers Act Accessibility Guidelines

MODULE 4 Planning your house continued

WASHROOM ACCESSORIES 2013 CATALOG

Chapter General. Accessible built-in storage facilities shall comply with Section 905. Chapter 9. Built-in Furnishings and Equipment

Bathroom Fittings. Hardware Bathroom Washroom Handrail Wardrobe Signs KNUD HOLSCHER H DESIGN

Hardware Bathroom Washroom Handrail Signs. Bathroom Fittings

SECTION PLUMBING FIXTURES

Advisory Raised Characters. Signs that are designed to be read by touch should not have sharp or abrasive edges.

SECTION 10520: FIRE EXTINGUISHERS AND CABINETS

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

Environmental component, the complete Housing Enabler instrument. Susanne Iwarsson & Björn Slaug Yes

IN T E R N A T I O N A L

HMMA 841 TOLERANCES AND CLEARANCES FOR COMMERCIAL DOORS AND FRAMES HOLLOW METAL -07 MANUAL AMERICAN NATIONAL STANDARD ANSI/ NAAMM METAL DOORS & FRAMES

ADDENDUM NOTICE INTERIOR RENOVATIONS AT THE BATHURST CLARK RESOURCE LIBRARY, 900 CLARK AVENUE WEST, VAUGHAN, ON

INSTALLATION INSTRUCTIONS

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

How-to-Measure Guide. for Kitchens & Baths

Das Haus additional options for interior design

2.0 Ergonomics. 2.1 General. 2.2 Disabled Access

Grab Bars. Wall-Mounted Grab Bars

TOLERANCES AND CLEARANCES FOR COMMERCIAL HOLLOW METAL DOORS AND FRAMES

UNIFIED FACILITIES GUIDE SPECIFICATIONS

ACCESSORIES

Jan H: ARCHITECTURAL WOODWORK (06410-H)

ProLine PL60 - PL70 - PL80 RETURN PANEL SUPPLEMENT

REVIVAL ACCESSORIES BEFORE YOU BEGIN A. HOW TO USE THESE INSTRUCTIONS B. PRODUCT NOTES C. ORDERING INFORMATION D. REQUIRED TOOLS AND MATERIALS

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 2

PRODUCT DATA SHEET DATI TECNICI. SHELL and CONSUMABLES MA-X AVAILABLE COLOURS X-FO X-TO X-TF

Last updated 8/26/2013

SECTION (10670) - WIRE CLOSET AND UTILITY SHELVING

Letter of Transmittal

Schematic Floor Plans Best Practices

SECTION IDENTIFYING DEVICES

North East Toilet Cubicles Ltd.

APPENDIX 1: CONSTRUCTION PLAN CHECKLIST

Required Tools: Suggested Additional Tools: 1 Cordless Drill with Robertson Bits 1 Ratchet Wrench 1 7/16 or 11mm socket 1 7/16 or 11mm Gear Wrench

Plain-O Helpers Grab bar installation guidelines, 2/5/16, 3/16/16. Grab Bar Installation Guidelines

SECTION (10670) - WIRE CLOSET AND UTILITY SHELVING

Chapter 4. Accessible Routes

DESIGN INSTRUCTIONS TO ARCHITECTS AND ENGINEERS [ ] SCHEMATICS [ ] DESIGN [ ] CONSTRUCTION

Never fill any required clearance space with insulation or any other building materials surrounding the chimney.

ID0.1 PALO VERDE 8000 WEST US HIGHWAY 290 AUSTIN, TX SHEET INDEX: CONTACT INFORMATION: DISCLOSURES: DOCUMENT GENERAL NOTES:

HOME MODIFICATIONS. Page H-3. Home Safety Check List Top Ten Things You Can Do To Help Other Accessibility Products To Consider H-5 H-9

Dry Toilet, Version 2.0 June 17, 2015

Installation Manual. Solid Plastic Toilet Partitions. IN CANADA & AREAS OTHER THAN U.S.A.: IN THE U.S.A.:

DRAWING MANUAL PROCLIP SYSTEM

SECTION FRAMELESS GLASS SLIDING BI-FOLD SHOWER DOOR HARDWARE

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

Installation Instructions 3040 (05-09) 9/16 9/ /32 9/32. Checking Adjustments

1. Field measurements must be taken to verify existing conditions prior to installation.

Installation of Balustrade Systems

Independent Containment System (ICS)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Tuxedo Console Table INSTALLATION INSTRUCTIONS P73037, P73038, P _2_B Page 1 of 5

Exhibit Design Regulations

Made possible by a generous grant from. Guidelines for Display Rules & Regulations 2014 Update

Frameless Inline Door QCI5250

Exhibit Design Regulations

COOL LINE. STAINLESS STEEL Designed and produced in DENMARK

Concinnity Transitional Kitchen Faucets

WADE 2-1. Universal Carrier. Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains.

SCHOOL SUPPLIES LIST PRE-KINDERGARTEN. $20.00 Activity Fee. pump dispenser bottles of antibacterial soap (7.5 oz)

STUDIO TO TRANSMITTER LINKING SYSTEM

FIXED PANEL SLIDER QCI5241

Matte Black NEW! D Series. Ask about other finishes! D D D D Fasteners Included M4 x 25

SINGLE TRACK BYPASS (patent pending) barn door hardware

FOLIO COUNTERTOP LAVATORY

Lesson 6. The Peg Game

June Advisory Services on Rewiring Works of Existing Buildings

Frameless Inline Door QCI5254

SOLAR SHADING SYSTEMS Manual Cordless Solar Shade

FRAMELESS DOOR / PANEL WITH WALL MOUNT HINGES QCI5274

Automatic Silverware Napkin Wrapping Machine: Phase II

Special Care. Care products 1:12:1 1:12:2. Rails and hinged supports. Icon key. Special Care. Blue Book Armitage Shanks. Residential.

Title: Test on 5.8 GHz Band Outdoor WiFi (802.11b/g) Wireless Base Station

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU SIGNS SUPPLEMENTAL ACCESSIBILITY PLAN REVIEW CHECKLIST NO.

MIND BLOWING MELT & POUR

Transcription:

Paper Towel, Toilet Paper, Soap and Hand Sanitizer Dispensers 4.2.5* Forward Reach. If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a)) <http://www.access-board.gov/adaag/html/figures/fig5a.html>. The minimum low forward reach is 15 in (380 mm). If the high forward reach is over an obstruction, reach and clearances shall be as shown in Fig. 5(b) <http://www.access-board.gov/adaag/html/figures/fig5b.html>. Appendix Note <http://www.access-board.gov/adaag/html/adaag.htm#a4.2.5> Figure 5a High Forward Reach Limit Forward reach range shown in profile and plan view to be 48 inches maximum and 15 inches minimum. Forward reach range shown in profile and plan view to be 48 inches maximum and 15 inches minimum. Figure 5b Maximum Forward Reach over an Obstruction The maximum level forward reach over an obstruction with knee space below is 25 inches (635 mm). When the obstruction is less than 20 inches (510 mm) deep, the maximum high forward reach is 48 inches (1220 mm). When the obstruction projects 20 to 25 inches (510 mm to 635 mm), the maximum high forward reach is 44 inches (1120 mm). (4.2.5, 4.25.3). Figure 5b Maximum Forward Reach over an Obstruction 4.2.6* Side Reach. If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9 in (230 mm) above the floor (Fig. 6(a) <http://www.access-board.gov/adaag/html/figures/fig6a.html> and (b)) <http://www.access-board.gov/adaag/html/figures/fig6b.html>. If the side reach is over an obstruction, the reach and clearances shall be a shown in Fig 6(c) <http://www.access-board.gov/adaag/html/figures/fig6c.html>. Appendix Note <http://www.access-board.gov/adaag/html/adaag.htm#a4.2.5> Figure 6(a) Clear Floor Space - Parallel Approach The 30 by 48 inch clear floor space is located a maximum 10 inches (255 mm) from the wall. s Top view of the 30 by 48 inch clear floor space for a wheelchair, shown a maximum of 10 inches from the wall along side it, on which an element, such as a light switch, might be located

Figure 6(c) Maximum Side Reach over Obstruction If the depth of the obstruction is 24 inches (610 mm) and the maximum height of the obstruction is 34 inches (865 mm), the maximum high side reach over the obstruction is 46 inches (1170). Front view of a wheelchair user reaching to the side over a counter 34 inches high, maximum, and 24 inches deep, maximum. The maximum high reach is 46 inches Toilet Paper Dispensers: 604.7 Dispensers. Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser. The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow. Advisory 604.7 Dispensers. If toilet paper dispensers are installed above the side wall grab bar, the outlet of the toilet paper dispenser must be 48 inches (1220 mm) maximum above the finish floor and the top of the gripping surface of the grab bar must be 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor. 609.4 Position of Grab Bars. Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except that at water closets for children s use complying with 604.9, grab bars shall be installed in a horizontal position 18 inches (455 mm) minimum and 27 inches (685 mm) maximum above the finish floor measured to the top of the gripping surface. The height of the lower grab bar on the back wall of a bathtub shall comply with 607.4.1.1 or 607.4.2.1. 609.3 Spacing. The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum. The space between the grab bar and projecting objects above shall be 12 inches (305 mm) minimum.