SGS United Kingdom Ltd. International Electrical Approvals. Electromagnetic Compatibility. RF Card Entry System. PAC International Ltd.

Similar documents
TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

TEST REPORT. PolyComp 32X80P7.621YHB Electronic Sign. tested to the. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices

TEST REPORT FROM RFI GLOBAL SERVICES LTD

STC Test Report. Date : Page 1 of 13 No. : HM161169

FCC Test Report. : ASE Group 4F,No 133, Sec 4, Mingsheng E Rd, Songshan Dist, Taipei, Taiwan

Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart C - Intentional Radiators

Page 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

EMI -- T E S T R E P O R T

Page 1 of 19 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

TEST REPORT. Table of Contents

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD

FCC 47 CFR PART 15 SUBPART B

Spurious Emissions & Emission Mark Report

DATES OF TESTS: From 03/10/2014 to 20/10/2014 and 25/02/2015. Open area test site in Aunainville (28) - FRANCE. Page 2 out of 54

Itron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards:

TEST REPORT. Report Number: MPK-007 Project Number: Report Date: August 31, 2007

RF test report AU01+W02

FCC Verification TEST REPORT

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : Fax:

: M Leach, Principal EMC Engineer.

Title: Test on 5.8 GHz Band Outdoor WiFi (802.11b/g) Wireless Base Station

UL Japan, Inc. Head Office EMC Lab Asama-cho, Ise-shi, Mie-ken JAPAN Telephone : Facsimile :

F2 Labs Peters Road Middlefield, Ohio United States of America

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards

FCC Report for Parts ,

Total number of pages : 116

Verification Test Report

EMI T E S T R E P O R T

DIGITAL OUTSTATION WITH RESPECT TO THE FCC RULES CFR 47, PART 90 INTENTIONAL RADIATOR SPECIFICATION ON BEHALF OF PALMER ENVIRONMENTAL

8370 Court Avenue, Suite B-1 Ellicott City, Maryland (410) FCC CERTIFICATION

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

CERTIFICATE. Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01

FCC CLASS B COMPLIANCE REPORT (DOC)

FCC C2PC Test Report

FCC/IC Test Report. : 2AOIMOMATA1 Equipment authorization required : SDoC IC ID

A RADIO TEST REPORT FOR. G4S Monitoring Technologies LTD. OM247 SOLO2 3G 915MHz DOCUMENT NO.TRA WUS4

Compliance Engineering Ireland Ltd

VCCI TEST REPORT. According to. Class B ITE. Equipment : USB video camera

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

C E R T I F I C A T I O N

APPROVED BY: DATE: 19-Aug-2011 Brian Boyea, EMC Engineer. TESTED BY: DATE: 12-Aug-2011 Arturo Ruvalcaba, EMC Engineer

FCC PART TEST REPORT. Weccan Industrial Limited

TRFWL. Autostart Inc Rue Paré Mont-Royal, Québec Canada, H4P 2M2 EZSNAH2503

TEST REPORT FROM RFI GLOBAL SERVICES LTD

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd

EMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight

TEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.:

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

FCC Certification Test Report for the MEI Cashflow RFID Reader Base FCC ID: QP8EASITRAXRB

TEST REPORT FROM RFI GLOBAL SERVICES LTD

Certification Test Report

TEST REPORT. Table of Contents

Advanced Compliance Solutions, Inc FAU Blvd, Suite 310 Boca Raton, Florida (561)

HID GLOBAL CORPORATION

QI HARDWARE INC. Ben NanoNote. Model: Ben NanoNote September Report No.: (This report supersedes NONE)

f02 January 11, TÜV Rheinland Nederland B.V. P.O. Box AA Leek (NL) Eiberkamp VT Leek (NL)

TEST REPORT CONCERNING THE COMPLIANCE OF PART 15 JBP

Test Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

TEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

IST EMC LAB. EMISSION TEST REPORT. : DSP-4284GM Basic Alternate. : PDP(Plasma Display Panel) : Daewoo Electronics Corp. : Daewoo Electronics Corp.

TEST SUMMARY. Prüfbericht - Nr.: Test Report No FIELD STRENGTH OF FUNDAMENTAL RESULT: Passed % BANDWIDTH RESULT: Passed

EMI T E S T R E P O R T

FCC MEASUREMENT REPORT

FCC DoC TEST REPORT To: PARTICLE INDUSTRIES, INC To: - Attn: Eric Attn: - Address: 1400 Tennessee St, #4 San Francisco, CA Address: -

TEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen

Test Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards:

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15.

Matric Limited Hill City Road R.R. #1 Box 421A Seneca, PA 16346

To «Test_Standards» Test of: Radwin Ltd. Outdoor Subscriber Radio Unit. To: FCC CFR 47 Part 15B; ICES-003 Issue 6: 2016

FCC Certification Test Report For the Mars Electronics (MEI) easitrax FCC ID: QP8EASITRAX

COMMUNICATION CERTIFICATION LABORATORY 1940 West Alexander Street Salt Lake City, UT

TEST REPORT CONCERNING THE COMPLIANCE OF AN INDUCTIVE LOOP VEHICLE DETECTOR, BRAND NORTECH, MODEL PD231 AND PD234 WITH 47 CFR PART

Test Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.

Electromagnetic Compatibility Test Report

TEST REPORT. Table of Contents

5. Maximum Conducted Output Power

T E S T - R E P O R T. Test Report No (Edition 1) for RF340-R. Inductive Tag Reader

FCC TEST REPORT. for. 47 CFR, Part 15, Subpart C. SPORTON International Inc.

FCC TEST REPORT. SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.

TRANSMITTER MODEL: KAS-2030M

Quality Auditing Institute # Schoolhouse Street, Coquitlam, BC, V3K 4X9, Canada. ISO Accreditation:

SILENT PARTNER Model No.: SCOOP FCC ID: WXMSCOOP. In Accordance With

F2 Labs Peters Road Middlefield, Ohio United States of America

ITL Page 2 of 71 Report No.:

Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E

TEST REPORT Title 47-Telecommunication

Transcription:

South Industrial Estate Bowburn Co. Durham DH6 5AD United Kingdom Tel: +44 (0) 191 377 2000 Fax: +44 (0) 191 377 2020 email: sgsiea@sgs.com SGS United Kingdom Ltd. International Electrical Approvals Electromagnetic Compatibility Test of: RF Card Entry System Model Number: Refer to page 5 Applicant: Test Type: Test Specification: Test Result: SGS Serial Number: PAC International Ltd Compliance FCC CFR47, parts 15.107, 15.109, 15.207 and 15.209 Complied DUR 24095/EMC/LS/02 Date of Receipt: 10 th June 2002 Date of Test(s): 10 th June 2002 20 th June 2002 Date of Issue: 9 th January 2003 This report refers only to the sample submitted for test. This report shall not be reproduced except in full without the written approval of the testing laboratory. Test Engineer L.Steel Authorised Signatory A. Reynard Technical Manager Page 1 of 15 Member of the SGS Group (Société Générale de Surveillance) Registered in England No. 1193985. Registered Office: Inward Way, Rossmore Business Park, Ellesmere Port, Cheshire, CH65 3EN.

Page 2 of 15 CONTENTS Page Number 1. Client Information... 3 2. Details Of Test Laboratory... 3 3. Equipment Under Test (EUT)... 4 3.1 Identification Of EUT... 4 4. Test Specification, Methods and Procedures... 4 4.1 Test Specification(s)... 4 4.2 Purpose Of Test... 4 4.3 Methods and Procedures... 4 EUT System Diagram... 5 5. Deviations or Exclusions from the Test Specifications... 6 6. Operation of the EUT During Testing / Configuration and Peripherals... 6 6.1 Operation of EUT during testing.... 6 6.2 Configuration and Peripherals... 6 7. Test Results... 7 7.1 General Comments... 7 7.2 Modifications Made to the EUT... 7 7.3 Summary of Test Results... 7 7.4 Conducted Emissions Test Results 15.107/15.207... 8 7.5 Radiated Emissions Test Results 15.109... 12 7.6 Radiated Emissions Test Results 15.209... 14

Page 3 of 15 1. Client Information Company Name: Address: Contact Person: PAC International Ltd 1 Park Gate Close, Bredbury, Stockport, SK6 2SZ. Shaun Byrne Telephone: 0161 406 3400 Facsimile: 0161 430 8658 2. Details Of Test Laboratory Company Name: SGS International Electrical Approvals UKAS Accreditation Number: 1116 Address: Contact Persons: South Industrial Estate, Bowburn, Co. Durham, DH6 5AD. Mr Alan Reynard Telephone: 0191 377 2000 Facsimile: 0191 377 2020

Page 4 of 15 3. Equipment Under Test (EUT) 3.1 Identification Of EUT Model Number: Refer to page 5. Unique Identifier: Refer to page 5 Description of EUT: RF Card Entry System Internal Clock Frequencies: Refer to page 5. Supply Voltage: (To Controller) Classification: Refer to page 5. Accessories Supplied: Refer to page 5. 16.5v ac, 12v dc or 15v dc, via adapters (see page 5) NOTE: All other parts of the system obtain their power via the controller. 4. Test Specification, Methods and Procedures 4.1 Test Specification(s) Specification(s) FCC CFR 47 : October 1999 Parts 15.107/15.207, 15.109 and 15.209 Title Code Of Federal Regulations 4.2 Purpose Of Test 1) To test the whole system to clauses 15.107/15.207 and 15.109 2) To test the 21446/2 front panel card reader only, to the requirements of 15.209 (Up to 30 MHz only). 4.3 Methods and Procedures The standard listed above refers to the following tests: - CFR 47 Clause Test 15.107/15.207 Conducted Emissions (Intentional and Unintentional Radiators) 15.109 (30-1000 MHz) 15.209 (9 khz to 30 MHz) Radiated Emissions (Intentional and Unintentional Radiators) Radiated Emissions (Intentional Radiator)

Page 5 of 15 EUT System Diagram 21446/2 Controller AC in 21446/2 Front panel card reader (part of controller) - Intentional Radiator DC in Reader Port 1 Lock Port Relay Port Reader Port 2 Lock Port Relay Port *1 *2 *1 *2 20422 Card Reader 20382 Card Reader 120V AC IN 120v ac/15v dc Switch mode adapter Model: MA15-120 Serial: none Manufacturer: Meanwell *1=150Ω/100nF networks as terminations. *2=150Ω resistors as terminations. *NOTE 3 120V AC IN 120v ac/16.5v ac adapter Model: Not supplied Serial: Not supplied Manufacturer: Basler Electric USA. NOTE 1: All interconnecting cables 1m long. Interconnecting cables are signal/low voltage dc. NOTE 2: Power adapters are not supplied by PAC. They are typical power supplies, supplied in order to perform the conducted emissions tests. Also note that the product operates from one adapter or the other i.e. they are not used simultaneously. NOTE 3: For testing to 15.107/15.207 a different ac/dc adapter was used to that shown above. The details of the adapter used for the Conducted Emissions are as follows: Manufacturer: Ecopac Power UK Ltd, Model: SA60-12v, Voltage: 12 v dc Component Model No. Serial No. Descsription Intentional/ Unintentional Radiator? Highest Generated/Used 21446/2 None Controller Unintentional 12.28 MHz 21446/2 None Front Panel Intentional and Unintentional 12.28 MHz 20422 1974357 Card Reader Intentional and Unintentional 614 khz 20382 1973947 Card Reader Intentional and Unintentional 614 khz

Page 6 of 15 5. Deviations or Exclusions from the Test Specifications There were no deviations from the test specifications. 6. Operation of the EUT During Testing / Configuration and Peripherals 6.1 Operation of EUT during testing. Refer to individual test results sections for details of EUT operation during testing. 6.2 Configuration and Peripherals Refer to page 5 for details.

Page 7 of 15 7. Test Results 7.1 General Comments The test methods used are referred to in the individual test results sections of this test report. 7.2 Modifications Made to the EUT No modifications were made to the EUT during the testing process. 7.3 Summary of Test Results CFR 47 Clause Test Result 15.107/15.207 Conducted Emissions (Whole EUT system tested) Complied 15.109 Radiated Emissions Complied (Whole EUT system tested) 15.209 Radiated Emissions Complied (PAC 21446/2 front panel card reader only) Result i) In the configuration tested, the whole system complies with the requirements of Clauses 15.107/15.207 and 15.109 of CFR 47 : October 1999. ii) In the configuration tested, the PAC 21446/2 front panel card reader complies with the requirements of Clause 15.209 of CFR 47 : October 1999, across the frequency range 9 khz to 30 MHz. Full details of all tests can be found in the test results section of this report.

Page 8 of 15 7.4 Conducted Emissions Test Results 15.107/15.207 Operating Mode CFR 47 Clause: 15.107/15.207 s: CISPR 22, Class B (As specified in FCC document FCC 02-157 (ET Docket No. 98-80), adopted May 23 rd 2002). Range 0.15 30 MHz. The compliance test was performed with authorised cards presented to the controller front panel reader, the 20422 reader and the 20382 reader. NOTE: s were performed at the AC mains of the controller: a) whilst operating via the AC/AC Adapter b) whilst operating via the AC/DC adapter. Test Method As per ANSI 63.4 : 1992 detector details: Quasi-Peak, 9 khz bandwidth Test Results NOTE: The test results shown have automatically been corrected to account for LISN attenuation and cable loss, via measurement software.

Page 9 of 15 Test Results a) whilst operating via the AC/AC Adapter Live Terminal Worst Case Emissions (MHz) Average Average 0.168 55.4 65.1 25.7 55.1 0.195 53.99 63.8 25.2 53.8 0.249 50.78 61.8 22.38 51.8 0.276 48.46 60.9 19.56 50.9 0.294 46.55 60.4 19.55 50.4 0.312 44.75 59.9 19.55 49.9 Neutral Terminal Worst Case Emissions (MHz) Average Average 0.150 55.15 66 26.45 56 0.168 55.44 65.1 25.64 55.1 0.195 54.03 63.8 24.43 53.8 0.204 53.43 63.4 24.43 53.4 0.258 50.3 61.5 21.4 51.5 0.294 46.79 60.4 19.59 50.4

Page 10 of 15 b) whilst operating via the AC/DC Adapter Live Terminal Worst Case Emissions (MHz) Average 0.177 42.34 64.63 54.63 0.240 44.01 62.1 52.1 0.303 29.48 60.16 50.16 1.203 35.49 56 46 1.626 35.48 56 46 11.922 28.67 60 50 NOTE: Average measurements not performed since Quasi-Peak measurements are below the Average limit. Neutral Terminal Worst Case Emissions (MHz) Average Average 0.184 45.37 64.3 43.47 54.3 0.246 44.77 61.9 44.17 51.9 0.426 40.7 57.3 40.5 47.3 1.07 34.47 56 31.67 46 15.5 31.85 60 28.85 50 28.91 17.68 60 9.18 50

Page 11 of 15 Conducted Emissions Test Configuration Conducted Emissions Environmental Conditions Power Supply (to controller) 120V, 60Hz Temperature 19.5 C Relative Humidity 43% Barometric Pressure 994mb Conducted Emissions Uncertainties Amplitude ± 200kHz ± 3.0dB The uncertainties stated are calculated in accordance with the requirements of UKAS with a confidence level of 95%. Test Equipment Used Equipment Type Model Number Last Calibration Date LISN (50Ω) Thurlby Thandar Jan 02 TTi 1600 Chase Receiver LHR7000 Sep 01 SGS Screened Room - - Spectrum Analyser HP8563E Nov 00 Check Equip. PLC 1C -

Page 12 of 15 Issue Date:23 rd December 2002 Issue Number: 2 7.5 Radiated Emissions Test Results 15.109 Operating Mode Test Results CFR Clause 15.109 s Class A Range 30-1000 MHz The compliance test was performed with authorised cards presented to the controller front panel reader, the 20422 reader and the 20382 reader. NOTE: The EUT was tested whilst powered by the AC/AC adapter. Worst Case Emissions MHz Quasi-Peak @10m (dbµv/m) Quasi-Peak @10m (dbµv/m) Antenna Polarity 66.342 20.34 39 Vertical 71.255 21.94 39 Vertical 81.125 26.64 39 Vertical 83.987 31.64 39 Vertical 86.004 33.04 39 Vertical 125.327 30.14 43.5 Vertical 130.243 32.14 43.5 Vertical 135.155 31.84 43.5 Vertical 140.100 32.34 43.5 Vertical 245.792 22.24 46.4 Vertical NOTE 1: The test results shown have automatically been corrected to account for Antenna factors, preamplifier gain and cable losses, via measurement software. NOTE 2: Vertical antenna polarity was worst case for all emissions, hence results for horizontal antenna polarity were not recorded. Test Method As per ANSI 63.4 : 1992 s performed at a test distance of 3m and extrapolated to an equivalent 10m value, by deducting an extrapolation factor of 20dB per decade. detector details: Quasi-Peak, 120 khz bandwidth

Page 13 of 15 Issue Date:23 rd December 2002 Issue Number: 2 Radiated Emissions Test Configuration Radiated Emissions Environmental Conditions Power Supply (to controller) 120V AC, 60 Hz Temperature 12 C Relative Humidity 67% Barometric Pressure Radiated Emissions Uncertainties 998mb Amplitude ± 200kHz ± 4.6dB The uncertainties stated are calculated in accordance with the requirements of UKAS with a confidence level of 95%. Test Equipment Used Equipment Type Model Number Last Calibration Date Receiver System HP 8573B Nov 01 Biconical Antenna EMCO 3110 Nov 00 Log Periodic Antenna EMCO 3146 Aug 01 Pre-amplifier ZHL 1042J Jan 02 Check Equip. York CNE III - Software Open Site HP85879 -

Page 14 of 15 Issue Date:23 rd December 2002 Issue Number: 2 7.6 Radiated Emissions Test Results 15.209 Operating Mode Test Results CFR Clause 15.209 Range 9 khz to 30 MHz The compliance test was performed with an authorised card presented to the controller front panel reader. Peak s MHz Corrected Peak (dbµv/m) (dbµv/m) *0.154-22.94 23.87 0.041-33.97-22.94 0.123-44.82-22.94 1 0.250-53.98-22.94 1 0.550-54.08-22.94 1 0.700-54.08-22.94 1 0.850-54.08-22.94 1 0.900-54.08-22.94 *Indicates EUT carrier frequency. The supply voltage to the controller was varied between 85% and 115% to maximise the carrier level. 1 Indicates typical noise floor figures of test equipment. Note: for spurious emissions is the measured level at the fundamental frequency, as per sec 15.209c. Test Method As per ANSI 63.4 : 1992 s performed at a test distance of 1m and extrapolated to correct distance of 300m, using a factor of 40 db/decade, hence a correction factor of 99.08 was used. The corrected levels are shown above. detector details: Peak Detector, 300 Hz bandwidth where F=<150kHz, 10 khz bandwidth where F=>150 khz

Page 15 of 15 Issue Date:23 rd December 2002 Issue Number: 2 Radiated Emissions Test Configuration Radiated Emissions Environmental Conditions Power Supply (to controller) 120V AC, 60 Hz Temperature 13 C Relative Humidity 59% Barometric Pressure Radiated Emissions Uncertainties 976mb Amplitude ± 200kHz ± 4.6dB The uncertainties stated are calculated in accordance with the requirements of UKAS with a confidence level of 95%. Test Equipment Used Equipment Type Model Number Last Calibration Date Loop Antenna EMCO 6502 Dec 00 Spectrum Analyser HP8563E Nov 00