High Voltage Instrumentation Cables for the ITER Superconducting Magnet Systems

Similar documents
High Performance Engineering

POLYIMIDE INSULATED WIRES AND CABLES, LOW FREQUENCY, 600V, -200 TO +200 C BASED ON TYPE SPL. ESCC Detail Specification No.

Testing of the Toroidal Field Model Coil (TFMC)

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

MATEFU Insulation co-ordination and high voltage testing of fusion magnets

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Technical Specifications: Supply of Seamless Grade TP304L Pipe and Grade WP304L Pipework Fittings to the ITER Organization (IO).

Tratos High Voltage cables

Testing Manual for Electrical Equipment

ITER NEWSLINE - Central solenoid fabrication: a photo reportage. 18 Jul,

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

The Results of the KSTAR Superconducting Coil Test

conductor Extruded Cross - Linked Polyethylene Insulated (XLPE) Power Cable Rated Voltage U 0 /U = 12/20 kv U 0 /U = 18/30 kv

Drexan Energy Systems Inc.

Status of Japanese DA

Market Survey. Technical Description. Supply of Medium Voltage Pulse Forming System for Klystron Modulators

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

Type 297, High-Voltage Mica Capacitors Corona-free Mica Coupling Capacitors for Medium-Voltage PDA s

REPORT OF PERFORMANCE TIC

THERMISTORS (THERMALLY SENSITIVE RESISTORS), NTC, RANGE 2000 TO OHMS AT +25 O C WITH A TEMPERATURE RANGE OF -60 O C TO +160 O C

INNOVATIVE PERSPECTIVES FOR ELECTRICITY TRANSPORT

Medium Voltage Power Cables

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

Technical Specification. for 1.1 KV Copper Control Cable

HIGH POWER COUPLER FOR THE TESLA TEST FACILITY

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

EXTRUDED, CROSS-LINKED FLUOROPOLYMER INSULATED WIRES AND CABLES ON SILVER-PLATED COPPER CONDUCTOR, LOW FREQUENCY, 600V, -100 TO +200 C

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

2.3 PF System. WU Weiyue PF5 PF PF1

HTS PARTIAL CORE TRANSFORMER- FAULT CURRENT LIMITER

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

COIL WINDING ISSUES P. Fabbricatore INFN Genova LCD - Magnet 13Oct09. Coil winding issues

STATUS OF THE KOLKATA K500 SUPERCONDUCTING CYCLOTRON

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

DEMO 5: HVDC Superconducting Link

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

Cryogenic Testing of Superconducting Corrector Magnets for the LHC Main Dipole

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

4. Superconducting sector magnets for the SRC 4.1 Introduction

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

STATUTORY INSTRUMENTS SUPPLEMENT No th June, 2016 STATUTORY INSTRUMENTS SUPPLEMENT

Market Survey on availability of engineering effort to perform R&D, preparatory and final design for diagnostics Remote Handling connector

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

RF CABLE ASSEMBLY, TNC, VERY HIGH POWER, 50 OHMS, SEMI-RIGID AND FLEXIBLE CABLE, DC TO 8GHZ BASED ON TYPE TNC-VHP

Sample Specification Electrical Heat Tracing Cables Metric Units

HV SYSTEMS. Prysmian HV Systems Product Range 66kV & 132 kv

Surface Mount Resistor Kit 0603 Case Size

SI.No Parameters CPRI Specification/Requirements To be Completed by the Bidder Guaranteed Technical

Metal Film Resistor Kit

Metal Film Resistor Kit

Pre-printed PVC Cable Markers O-Type, K-type, Z-type, V-Type

STATUS OF THE SUPERCONDUCTING CYCLOTRON PROJECT AT VECC

ECP HV INSULATION TESTING

Physical Properties Measurement System (PPMS): Detailed specifications: Basic unit cryogen- free

EDS LV WAVEFORM MAINS CABLE RATINGS

TECHNICAL SPECIFICATION FOR. CONTACT WIRE HARD-DRAWN COPPER 161mm2

Liquid-Filled Transformers

Services of a Neutral Beam Specialist for the Neutral Beam Section of the Heating & Current Drive Division of ITER. Technical Specifications

SECTION - II BID DATA SHEET

Underground System Design TADP 547

76 / 132 (145) kv 1x1200 mm 2 CU/XLPE/CWS/AL/HDPE

TECHNICAL SPECIFICATIONS

REQUEST FOR INFORMATION (RFI) RFI NO: /WJG

The RSM shall be extensively used in field & laboratory for verification of the accuracy of all types of single-phase energy meters.

Application Guidance Notes: Technical Information from Cummins Generator Technologies

MILITARY SPECIFICATION LIGHTING, INSTRUMENT, INTEGRAL, WHITE GENERAL SPECIFICATION FOR

Impulse testing of coils and magnets: present experience and future plans

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

SECTION COMMUNICATIONS COPPER BACKBONE CABLING

Signal converter for electromagnetic flowmeters

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

TESLA RF POWER COUPLERS DEVELOPMENT AT DESY.

DNVGL-CP-0400 Edition December 2015

25th SOFT Page 1 of 11

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

J O I N T I N D U S T R Y S T A N D A R D. Requirements for Soldering Pastes J Standard 005A. December 2011

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

Surface Mount Resistor Kit 0603 Case Size

SECTION COMMUNICATIONS COPPER BACKBONE CABLING

JB/T Translated English of Chinese Standard: JB/T

3.7 Grounding Design for EAST Superconducting Tokamak

Miljardkonferensen Procurement at CERN

Task on the evaluation of the plasma response to the ITER ELM stabilization coils in ITER H- mode operational scenarios. Technical Specifications

HV BOARDS and MUMETAL Integration. Claudio Arnaboldi Tito Bellunato Emanuele Panzeri Gianluigi Pessina (*) INFN Milano Bicocca

EDS KV SINGLE CORE XLPE CABLES

INDEX OF REVISIONS DESCRIPTION AND/OR AFFECTED SHEETS

ASSEMBLY TOOLS FOR SCREWS & NUTS. Part 1: Insulated hand operated socket drive wrenches and screw drivers

Status of ATLAS & CMS Experiments

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

TESLA Quad Package With BPM

Transcription:

High Voltage Instrumentation Cables for the ITER Superconducting Magnet Systems Summary for Call for Nominations 1. Background and scope ITER will be the world's largest experimental facility to demonstrate the scientific and technical feasibility of fusion power. The superconducting magnets providing the magnetic fields necessary to the generation and operation of the plasma contain many different sensors. Each sensor measures a specific physical parameter of the magnet system (voltage, helium mass flow, pressure, temperature, strain, displacements, etc.). The instrumentation wires of all those sensors at a temperature level of around 4.2 K will be routed from the inside of the cryostat to the feedthroughs located at the feeders cryostat wall at room temperature. A large quantity of these sensors e.g. voltage taps and some temperature measurements are on high voltage (HV) and accordingly also the instrumentation cables for these sensors. This document outlines the technical requirements for the high voltage cables, their testing as well as the qualification to meet ITER requirements. 2. Strategy ITER IO is conducting a call for nominations with the DAs in the frame of the procurement of high voltage (HV) instrumentation cables. The call for nominations is for companies in the domain of instrumentation cables for high voltage and low temperature (4.5 K) application and for which a high degree of reliability is required. ITER IO will select companies with whom to launch qualification contracts for the production a short unit length of 200 m. These companies will be selected following the qualification criteria as indicated in the section below. Once these qualification contracts are concluded, and as a part of the same process, a call for tender will be performed with successful companies (the ones having submitted the final products within the specification). As a result of the tender action, one (or more) companies will be awarded the final production contract (or a large fraction of it). It is expected that if possible at least two companies will be involved in the production. This will help keeping competition and is a fallback solution in case of problems.

3. Schedule and milestones The following is a forecast of the overall process including series production: - Call for nominations for qualification prototypes by January 2012 - Contracts for development and qualification prototypes placed by April- May 2012 - Submission of prototypes with certificates by July 2012 - Call for tender for final production by September 2012 - Final contract(s) awarded by December 2012 4. Quantities As indicated above, the call for nominations for prototypes requires the production and delivery of a continuous unit length of 200 metres. As additional information for companies, it is announced that the total length for the series production will be approximately 80 km, with the possibility of different numbers of individual wires. The design will be the same independent of the number of wires. 5. Technical requirements The HV instrumentation cables integrate wires for the connection of the terminal of protection resistors at high voltage to the feedthrough on the surface of the vacuum vessel. The protection resistors are installed next to the voltage taps sitting on high voltage pipes of the superconducting coil. The HV instrumentation cables basically must: - Give the following galvanic separation at high voltage from the individual wire and the HV shield with respect to the ground shield around it (see Fig. 1): Rated voltage 30 kv DC 20 kv AC Test voltage 56 kv DC 40 kv AC The DC test voltage of 56 kv and AC voltage of 40 kv is only applied during the tests of the HV cable itself and together with the attached feedthrough. The test voltage must be applied at least for 10 min. During routine tests once cables are attached to the superconducting coils, only a test voltage of 30 ka DC will be applied without a limit for time or number of tests. - Give galvanic separation between the individual wires (in the range from 2 to 6) and also to the HV shield, Rated voltage 2.5 kv DC 1.8 kv AC Test voltage 5 kv DC 3.5 kv AC

- Assure the galvanic separation in Paschen condition of helium around the HV instrumentation cable and this requires a continuous manufactured dielectric insulation (for example extruded) and explicitly excludes techniques based only on wrapping of tapes, which may be porous to gaseous helium, - Include individual wires made of copper filament wires (between AWG19 and AWG28), silver coated and twisted as pairs. The twist pitch can be defined at a later stage, - Have the HV shield as well as the ground shield fabricated from copper mesh, silver coated and should cover at least 85 % of the surface, - Use the following insulation materials, or combination of them, in extruded or film conditions can be used for all insulation steps as far as the other requirements like HV Paschen tightness can be met: o high density thermoplastic polyethylene (HDPE), o cross-linked polyethylene (XLPE) o polyimide (PI), - Have the individual wires coulored/numbered coded every 100 mm, - Tolerate an operating temperature which is between 4.2 K at the cold end on the superconducting coils side and room temperature at the warm feedthrough of the vacuum port, - Have an outer diameter (which depends on the number of wires and on the required HV insulation) as small as possible for flexibility and space reasons - Allow integration as well as Paschen-tight curing into the epoxy resin on the cold side to the protection resistor and the warm side to the feedthrough, - Have an gassing rate in the range of 1 x 10-9 Pa m 3 s -1 m -1 at 20C after 100 hrs under vacuum, - Be able to withstand an integrated dose of at least 100 kgy. This will prevent from using insulation materials which are not suited for this level of radiation, - Allow a bending radius smaller than 300 mm. - Have a high degree of reliability for an operating life of 30 years. Ground Insulation Fig. 1 Cross section of an example of a HV cable [1]

6. Test programme The HV and partial discharge tests carried out by the Contractor during the prototype production must confirm the quality of the insulation. All the other tests -marked below with an *- will be carried out by Associated Institutes to the ITER Organisation (IO). The Contractor shall propose a detailed test programme for the tests carried out by its means. Test certificates must be provided accordingly with respect to the established standards. The IO Associated Institutes will provide test reports to the suppliers for tests carried out at their premises. This should be considered as an advantage by the Contractors who will receive complete datasheets for their records providing considerable added value. o AC and DC voltage tests in air using the following voltages: wire to wire and wire to HV shield 5 kv and wire and HV shield to ground shield 56 kv, and corresponding AC values, o *AC and DC voltage tests with low pressure helium around the cable in Paschen condition and the same voltages as above, o *Fatigue bending test at room temperature and at 77 K, o Partial discharge test: the partial discharge inception and extinction voltages shall be determined at a discharge magnitude of 5 pc, the sensitivity of the detector shall be better than 1 pc, o *Radiation resistance, and in particular fatigue bending tests at 77 K after irradiation, o *Outgassing test at room temperature o *Assembly tests with a subsequent HV and Paschen test to a feedthrough, a coil sensor mock-up including the protection resistor During prototype and series production all manufactured items will pass a strict quality control test procedure which shall be proposed by the Contractor. The detailed HV and partial discharge test programme for the prototype production shall include at least: Equipment Testing plans Testing electrical diagrams Ambient atmosphere temperature and relative humidity Method of voltage application Acceptance criterion Calibration of equipment plans Non-conformances report and corrective actions Identification and traceability plans Reports templates The detailed HV and partial discharge test programme shall be submitted to IO for approval prior to the start of high voltage testing operations.

7. Pre-qualification criteria In order to be pre-qualified, Companies must have in hand all the following aspects of proven experience and know-how for at least the last 10 years: - Experience in the domain of high voltage instrumentation cables (PQC1) - Experience with insulation materials used in applications at cryogenic temperatures (supercritical, super fluid or liquid Helium) (PQC2) - Experience with insulation materials used in applications under radiation loads (PQC3) - Experience with Partial Discharge measurements and related equipment (PQC5) Companies must be equipped with all machines and equipment which allow the complete in-house manufacturing of the cables (stranders, braders, film-insulating machines, continuous extruders, jacketing lines, etc) (PQC6) Companies must have in possession an ISO 9001 certificate or equivalent. (PQC7) 8. References [1] The electrical insulation system of a forced flow cooled superconducting magnet, K. Bauer et al. (ITP-FzK, Leopoldshafen, Germany), Cryogenics 38 (1998) 1123-1134. 9. Candidature Participation is open to all legal persons participating either individually or in a grouping (consortium) which is established in an ITER Member State. A legal person cannot participate individually or as a consortium partner in more than one application or tender. A consortium may be a permanent, legally-established grouping or a grouping, which has been constituted informally for a specific tender procedure. All members of a consortium (i.e. the leader and all other members) are jointly and severally liable to the ITER Organization. The consortium cannot be modified later without the approval of the ITER Organization. Legal entities belonging to the same legal grouping are allowed to participate separately if they are able to demonstrate independent technical and financial capacities. Bidders s (individual or consortium) must comply with the selection criteria. IO reserves the right to disregard duplicated references and may exclude such legal entities form the tender procedure.