SDN-C Single and three phase power supplies Product Guide

Similar documents
Power Supplies 3. SDN-C Compact DIN Rail Series

Single or parallel use selectable by user Adjustable output voltage. New narrow width saves panel space

Related Products SDP Series SFL Series SCP Series SCL Series SDU UPS

Power Supplies. SCL Series. Features. Related Products. Applications

DC Power Supply Selection Process...99 DIN Rail Selection Tables...100

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

CB Scheme UL508 UL ATEX II3G

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Output Voltage* (nom.)(adjustable)

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Switching Power Supply Type SPP1 60W Enclosed type

Type CP-S, CP-C & CP-A Switch mode

Power Conditioners product guide

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Switching power supplies CP range, Linear power supplies CP-L range. Content

CP-T range Product group picture

Power Supplies. Visit our website at or Contact Technical Services at (800) with any questions.

LB115S 115W Single Output

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply.

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Metal Case Power Supplies

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

General. Environmental. EMC & Safety

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

Electrical Specifications

Power supply CP-E 24/0.75

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

CP-E range Benefits and advantages

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

Power supply CP-D 24/4.2 Primary switch mode power supply

TE60 60W Single Output External Power Test & Measurement/Industrial Series

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

Watts HCP Series

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms. 100mVp-p 200mVp-p 120mVp-p 240mVp-p -25 C - 70 C 48Vout 240mVp-p

Power supply CP-T 24/20.0 Primary switch mode power supply

CP-T range Benefits and advantages

C B. Models. Models 2MOPP

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

Doc. EA Model Number:

Electrical Specifications

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

Power supply CP-E 24/20.0

General. Environmental. EMC & Safety

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

TE60 60W Single Output External Power Test & Measurement/Industrial Series

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

Primary switch mode power supplies Product group picture

4.59A 2.36A 6.8A 13A 3.85W 2.85W ms 21ms. 31ms 100ms 48Vout 49ms 100ms. 240mVp-p 480mVp-p C 48Vout 480mVp-p

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE BPS-460RDX 6-OUTPUT 460W+460W BEST POWER SOLUTIONS, INC.

Power supply CP-E 24/2.5

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Power supply CP-T 24/10.0 Primary switch mode power supply

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

Power supply CP-T 48/20.0 Primary switch mode power supply

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

Power Supplies. Certifications and Compliances Recognized Component, ITE - UL Certified, ITE - CSA C22.2 CSA

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Electrical Specifications

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Power supply CP-T 24/40.0 Primary switch mode power supply

TE W Single Output External Power Test & Measurement/Industrial Series

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Output Voltage nom. (adjustable)

LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features

TE40 40W Single Output External Power Test & Measurement/Industrial Series

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

QUINT-PS/ 3AC/24DC/10

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

Line Reg Load Reg Ripple Efficiency *Model Number Output V Output I (nom/max) (nom/max) & Noise (min/nom)

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

SPECIFICATIONS. Input Output Approvals

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

Power supply CP-T 48/5.0 Primary switch mode power supply

FEATURES AND BENEFITS. Compact size: 6.5 x 2.8 x 1.5

Transcription:

SDN-C Single and three phase power supplies Product Guide

Compact PERFORMANCE DIN RAIL Series Our next-generation SDN-C power supplies offer high efficiency in a compact size, providing up to 960 Watts of output power in both single- and three-phase models. Featuring diagnostic LEDs, sag immunity, power factor correction and universal voltage, these are the highest performing DIN rail-mounted power supplies available for industrial use. Applications Industrial/machine control Process control Conveying equipment Material handling Vending machines Packaging equipment Amusement park equipment Semiconductor fabrication equipment Features Compact packaging saves space on the DIN rail Visual diagnostic LEDs provide input and output status at a glance Higher efficiency saves energy and lowers amount of heat generated inside the panel PowerBoost overload capability starts high inrush loads without foldback or shutdown Accepts Universal voltage 85-264 Vac, 50/60 Hz input Single phase models meet SEMI F47 sag immunity Active power factor correction Class I Zone 2 hazardous locations rating ATEX approved on select models User adjustable output voltage accessible via front face Parallel capability standard Industrial grade design -25 C to 60 C operation without derating High MTBF means high reliability and long life RoHS compliant Highly efficient switching technology Five-year warranty Certifications and Compliances All Models: Listed, Ind. Control Equipment, E61379 - UL 508, CSA C22.2 No. 107.1 UL Recognized Component, ITE, E137632 - UL 60950-1/CSA C22.2 No. 60950-1, 2nd Edition - Low Voltage Directive - IEC/EN60950-1, 2nd Edition Sag Immunity: SEMI F47 RoHS Compliant Models SDN 20-24-480CC, SDN 40-24-480C: UL Recognized Component, Haz. Loc., E234790 - ISA 12.12.01, CSA C22.2 No. 213 - Class I, Division 2, Groups A, B, C, D Models SDN 5-24-100C, SDN 10-24-100C, SDN 20-24-100C,SDN40-24-100C, SDN 5-24-480C, SDN 10-24-480C: UL Recognized Component, Haz. Loc., E234790 - UL 60079-15/CSA E60079-15 - Class I, Zone 2, AEx nc IIC, Ex nc IIC ATEX Directive - EN60079-0, EN60079-15 - II 3 G, Ex na nc IIC Gc IECEx Certified - IEC 60079-0, IEC 60079-15 - Ex na nc IIC Gc

? versatile power supply for single and three phase input power A B C F D E H G IECEx E61379 E137632 E234790 A B C PowerBoost Powers high inrush loads without shutdown or foldback Allows designers to save money by sizing for peak loads Industrial Grade Design Metal enclosure with small vents to keep small parts from falling in Patented durable mounting clip (designed to withstand 40G of shock without falling off rail) Wide temperature performance: guaranteed reliability at full load over a wide temperature range of -10 C to +70 C (+14 F to +158 F) with no derating until after +60 C (+140 F) DC OK Signal Allows remote notification of DC power loss to the controller F G 3 LED Diagnostics Shows status of input power, output power and alarm condition Valuable troubleshooting aid to reduce system downtime Wide Range Input With Sag Immunity No need to worry about different wiring or switch positions when applying different input voltages All single phase models can operate from 100, 110, 115, 120, 127, 200, 208, 220, 230 or 240 Vac inputs with no jumper or switch changes Easily handles sags down to half the line voltage with no disruption in output power, increasing equipment reliability and availability Models comply with SEMI F47 standards for the semiconductor machine builder industry at all input line and output load conditions D E Adjustable Voltage Flexibility to set DC voltage perfectly for application requirements Single or Parallel Use Selectable One model to stock for single or multiple applications Easily scalable for higher power applications Current sharing for maximum reliability External modules available for full redundancy H Compliances Listed, Industrial Control Equipment, E61379 ITE, E137632 Haz. Loc., E234790 - Class 1, Div 2/Zone 2 Non-Incendiary Temperature class T3 or T4, groups IIC ATEX Approved on select models for Low Voltage and EMC Directives - Power factor correction (low frequency emissions)

C US LISTED SDN-C Series Dimensions W D Catalog Number Dimensions - mm (in) H W D + + - - 24 VDC /2.5 A OK SDN 5-24-100C 123.0 (4.85) 50.0 (1.97) 111.0 (4.36) OK 24-28 V NEC Class 2 Power Supply SDN 10-24-100C 123.0 (4.85) 60.0 (2.36) 111.0 (4.36) H Single Parallel S O L A Power Supply SDN5-24-100C 2.5-24-100P SDN 20-24-100C 123.0 (4.85) 87.0 (3.42) 127.0 (4.98) SDN 5-24-480C 123.0 (4.85) 50.0 (1.97) 111.0 (4.36) SDN 10-24-480C 123.0 (4.85) 60.0 (2.36) 111.0 (4.36) SDN 20-24-480CC 123.0 (4.85) 85.0 (3.35) 119.0 (4.68) U L 115/230 VAC 1.3-0.7 A 50/60 HZ N L SDN 40-24-100C and SDN 40-24-480C Dimensions W D 139.96 mm (5.51 in.) H Power Supply Signal Connector 1 D + 13.80 mm (0.54 in) Catalog Number Dimensions - mm (in) H W D SDN 40-24-100C 123.0 (4.85) 180.0 (7.09) 118.0 (4.66) SDN 40-24-480C 123.0 (4.85) 180.0 (7.09) 122.0 (4.81) 1. SDN 40-24-100C and SDN 40-24-480C output signaling terminal block features: Shut Down, Power Good, Current Monitor, Current Balance, GND, and active current sharing through I_SHARE connectors (See Signals Manual for connection information).

SDN-C Specifications (Single Phase) Description Nominal Voltage -AC Range -DC Range 1 -Frequency SDN 5-24-100C Catalog Number Input 115-230 Vac 85-264 Vac 90-375 Vdc 43-67 Hz SDN 10-24-100C Nominal Current 2 1.65-0.55 A 3.2-1.0 A -Inrush current max. Typ. < 15 A Typ.< 30 A Efficiency (Losses 3 ) > 88% typ. (14 W) > 90% typ. (24 W) Power Factor Correction Active power factor correction to better than 0.92 Output Nominal Voltage 4 24 V (23.5~28.5 Vdc Adj.) -Tolerance < ±2 % overall (combination Line, load, time and temperature related changes) Initial Voltage Setting 24.5 V ± 1% -Ripple 5 PARD Overvoltage Protection Power Back Immunity < 50 mvpp PARD (Periodic and Random Deviation) = 100 mv peak-peak max > 30.5 but < 33 Vdc, auto recovery Nominal Current 5 A (120 W) 10 A (240 W) -Peak Current 6 -Short Circuit Current -Current Limit Parallel Operation Holdup Time Voltage Fall Time < 35 V 1.5 Nominal Current for 4 seconds minimum while holding voltage > 20 Vdc 1.5 x Nominal Current at near zero volts at short circuit condition PowerBoost Switch selectable single unit or parallel unit operation. Units will not be damaged by parallel operation (regardless of switch position setting). >20 ms (Full load, 100 Vac Input @ T amb = +25 C (+77 F) to 95% output voltage <150 ms from 95% to 10% rated voltage @ full load (T amb = +25 C (+77 F) Line and Load Regulation < 0.5% EMC: -Emissions -Immunity Temperature 7 MTBF 8 Warranty General Protection/ Safety Status Indicators Fusing -Input -Output Mounting Connections General EN61000-6-2:2001, EN61000-6-3:2001, Class B EN55011, EN55022 Radiated and Conducted including Annex. A, EN61000-3-2 EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3, EN61000-4-4 Level 4 input and level 3 output. EN61000-4-5 Isolation class 4, EN61000-4-11, IEC 61000-4-34 voltage dip immunity standard Storage: -40 C to + 85 C (-40 F to +185 F), Operation -25 C to +60 C (-13 F +140 F) to full power, with linear derating to half power from +60 C to +70 C (+140 F to +158 F)(Convection cooling,no forced air required). Operation up to 50% load permissible with sideways or front side up mounting orientation. > 550,000 hrs 5 Year Limited Warranty Protected against continuous short -circuit, continuous overload, continuous open circuit. Protection Class 1 (IEC536), degree of protection IP20 (IEC60529) Safe low voltage: SELV (acc. IEC60950-1) Visual: 3 status LEDs (Input, Output, Alarm) Relay: N.O. contact rated 200ma/50 Vdc Installation Internally fused Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping. Simple snap-on to DIN TS35/7.5 or TS35/15 rail system. Input: Screw terminals, connector size range: 16-10 AWG (1.5-6 mm 2 ) for solid conductors. Screw torque: 4.4 lb-inch (~ 50 N-cm). Output: Two terminals per output, connector size range: 16-10 AWG (1.5-6 mm 2 ) for solid conductors. Screw torque: 7 lb-inch (~ 80 N-cm). Fully enclosed metal housing with fine ventilation grid to keep out small parts. 25 mm above and below, 10 mm left and right, 15 mm in front Case -Free Space H x W x D inches mm (in) 123.0 x 50.0 x 110.0 (4.85 x 1.97 x 4.36) 123.0 x 60.0 x 110.0 (4.85 x 2.36 x 4.36) Weight kg (lbs) 0.50 (1.1) 0.80 (1.7 ) 1. Not UL listed for DC input. 2. Input current ratings are conservatively specified with low input, worst case efficiency and power factor. 3. Losses are heat dissipation in watts at full load, nominal input line. 4. 24-28 Vdc adjustable guaranteed at full load. 5. Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor. 6. Peak current is calculated at 24 Volt levels. 7. Contact tech support for operation at -25 o C. 8. Demonstrated through extended life test.

SDN-C Specifications (Single Phase) SDN 20-24-100C Catalog Number SDN 40-24-100C Description Input Nominal Voltage 115-230 Vac -AC Range 85-264 Vac -DC Range 1 90-375 Vdc -Frequency 43-67 Hz Nominal Current 2 6-3 A 12-4 A -Inrush current max. < 40 A Typ. <60 A Efficiency (Losses 3 ) > 92% (38 W) > 93 % (67 W) Power Factor Correction Active power factor correction to better than 0.92 Output Nominal Voltage 4 24 V (23.5~28.5 Vdc Adj.) -Tolerance < ±2 % overall (combination Line, load, time and temperature related changes) Initial Voltage Setting 24.5 V ± 1% -Ripple 5 <100 mvpp < 100 mvpp PARD PARD (Periodic and Random Deviation) = 100 mv peak-peak max Overvoltage Protection > 30.5 but < 33 Vdc, auto recovery Power Back Immunity < 35 V Nominal Current 20 A (480 W) 40 A (960 W) -Peak Current 6 1.5 Nominal Current for 4 seconds minimum while holding voltage > 20 Vdc -Short Circuit Current 1.5 x Nominal Current at near zero volts at short circuit condition -Current Limit PowerBoost Parallel Operation 7 Switch selectable single unit or parallel unit operation. Units will not be damaged by parallel operation (regardless of switch position setting). Holdup Time >20 ms (Full load, 100 Vac Input @ T amb = +25 C (+77 F) to 95% output voltage Voltage Fall Time <150 ms from 95% to 10% rated voltage @ full load (T amb= +25 C (+77 F) Line and Load Regulation < 0.5% General EMC: -Emissions -Immunity EN61000-6-2:2001, EN61000-6-3:2001, Class B EN55011, EN55022 Radiated and Conducted including Annex. A, EN61000-3-2 EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3, EN61000-4-4 Level 4 input and level 3 output. EN61000-4-5 Isolation class 4, EN61000-4- 11, IEC 61000-4-34 voltage dip immunity standard EN61000-6-3, EN61000-6-4, Class B EN55011, EN55022 Radiated and Conducted including Annex A, EN61000-3-2, EN61000-3-3 EN61000-6-1, EN61000-6-2, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-4 Level 4 input and Level 3 output, EN61000-4-5 Installation Class 4, EN61000-4-6 Level 3, EN61000-4-8, EN61000-4-11, SEMI F47 Sag Immunity, Transient protection according to VDE 0160/W2 over entire load range. Storage: -40 C to +85 C (-40 F to +185 F), Operation -25 C to +60 C (-13 F to +140 F) full power, with linear derating to half power Temperature 8 from +60 C to +70 C (+140 F to +158 F) (Convection cooling, no forced air required). Operation up to 50% load permissible with sideways or front side up mounting orientation. MTBF 9 > 450,000 hrs > 500,000 hours demonstrated Warranty 5 Year Limited Warranty General Protection/ Safety Status Indicators Fusing -Input -Output Mounting Connections 10 Protected against continuous short -circuit, continuous overload, continuous open circuit. Protection Class 1 (IEC536), degree of protection IP20 (IEC60529) Safe low voltage: SELV (acc. IEC60950-1) Visual: 3 status LEDs (Input, Output, Alarm) Relay: N.O. contact rated 200ma/50 Vdc Installation Internally fused Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping. Simple snap-on to DIN TS35/7.5 or TS35/15 rail system. Input: Screw terminals, connector size range: 16-10 AWG (1.5-6 mm 2 ) for solid conductors. Screw Torque: 4.4 lb-in (~ 50 N-cm). Output: Two terminals per output, connector size range: 16-10 AWG (1.5-6 mm 2 ) for solid conductors. Screw Torque: 7 lb-inch (~ 80 N-cm) Input: Screw terminals, connector size range: 16-10 AWG (1.5-6 mm 2 ) for solid conductors. Screw Torque: 4.4 lb-inch (~ 50 N-cm). Output: Two terminals per output, connector size range: 10-6 AWG (6-14 mm 2 ) for solid conductors. Screw Torque: 15.6 lb-inch (~ 176 N-cm) Case Fully enclosed metal housing with fine ventilation grid to keep out small parts. -Free Space 25-40 mm above and below, 10 mm left and right, 15 mm in front Dimensions mm (in) H x W x D 123.0 x 87.0 x 127.0 (4.85 x 3.42 x 4.98) 123.0 x 180.0 x 122.0 (4.85 x 7.09 x 4.81) Weight kg (lbs) 1.20 (2.6) 2.75 (6.0) 1. Not UL listed for DC input. 2. Input current ratings are conservatively specified with low input, worst case efficiency and power factor. 3. Losses are heat dissipation in watts at full load, nominal input line. 4. 24-28 Vdc adjustable guaranteed at full load. 5. Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor. 6. Peak current is calculated at 24 Volt levels. 7. All models except the 40amp unit are capable of parallel operation by use of a jumper pin, accessible by the end user. 40 amp unit will have active current sharing signal. 8. Contact tech support for operation at -25 o C. 9. Demonstrated through extended life test. 10. SDN 40-24-100C only = Output signaling terminal block features (Shut down, Power Good, Current Monitor, Current Balance, signal GND).

SDN-C Specifications (Three Phase) Catalog Number SDN 5-24-480C SDN 10-24-480C SDN 20-24-480CC SDN 40-24-480C Description Input Nominal Voltage 380-480 Vac Two - phase input Yes 1 -AC Range 2 320-540 Vac -DC Range 450-760 Vdc 450-760 Vdc 450-760 Vdc 10 N/A -Frequency 50/60 Hz Nominal Current 3 3 x 0.5 or 2 x 0.7 A 3 x 0.8 or 2 x 1.2 A 3 x 0.9 or 2 x 1.3 A 3 x 1.6 A -Inrush current max. Typ. <25 A Negligible Negligible Efficiency (Losses 4 ) > 85% (18 W) 91.2% (23.6 W) 93% (42 W) 94% (78 W) Power Factor Correction Power factor correction to meet EN61000-3-2 Class A Active Power Factor Correction Output Turn on time Typ. 1s Voltage Rise Time ca. 5-20 ms <100 ms full resistive load (T amb = +25 C (+77 F) Power Back Immunity <35 V Overvoltage Protection >30.5 but <33 Vdc auto recovery Nominal Voltage 5 24 V (23.5~28.5 Vdc Adj.) Voltage Regulation < ±2 % overall Initial Voltage Setting 24.5 V ± 1% -Ripple 6 <100 mvpp PARD PARD = 100 mv peak-peak max PARD = 200 mv peak-peak max Nominal Current 5 A (120 W) 10 A (240 W) 20 A (480 W) (constant power, not constant current) 40 A (960 W) -Peak Current 7 6A, 2 Nominal Current <2sec 12A, 2 Nominal Current <2sec 1.5 Nominal Current for 4 sec minimum while holding voltage > 20Vdc -Current Limit PowerBoost Derating typ. 6 W/ o C typ. 12 W/ o C typ. 24 W/ o C typ. 48 W/ o C Holdup Time >20 ms >15 ms Voltage Fall Time <150 ms from 95% to 10% rated voltage @ full load <50 ms from 95% to 10% rated voltage @ full load (T amb= +25 C (+ 77 F) (T amb=+25 C (+ 77 F) Parallel Operation 8 operation, use of external diode module is preferred Single or Parallel operation selectable via front switch. For redundant Active Paralleling General Case Fully enclosed metal housing with fine ventilation grid to keep out small parts. Min. Required 25mm above and below or 15mm in front 25mm above and below or 10mm in front 70mm above and below or 25mm in front and 25mm left & right 123.0 x 85.0 x 119.0 (4.85 x 3.35 x 4.68) 70mm above and below, 15mm in front, 25mm left & right Free Space Dimensions mm (in) H x W x D 123.0 x 50.0 x 111.0 (4.85 x 1.97 x 4.36) 123.0 x 60.0 x 111.0 (4.85 x 2.36 x 4.36) 123.0 x 180.0 x 119.0 (4.85 x 7.09 x 4.66) Weight kg (lbs).52 (1.2) 0.70 (1.5) 1.30 (2.9) 2.40 (5.3) EMC: -Emissions EN61000-6-3:2001, Class B EN55011, EN55022 Radiated and Conducted including Annex. A, EN61000-3-2 -Immunity EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3, EN61000-4-4 Level 4 input and level 3 output. EN61000-4-5 Isolation class 4, EN61000-4-11 Storage : -40 C to +85 C (-40 F to +185 F), Operation -25 C to +60 C (-13 F to +140 F) full power,with linear derating to half power Temperature from +60 C to +70 C (140 F to 158 F) (Convection cooling, no forced air required). Operation up to 50% load permissibl with sideways or front side up mounting orientation. Humidity < 90% RH, noncondensing; IEC 60068-2-2, 68-2-3 Altitude 0 to 3000 meters (0 to 10,000 feet) Vibration 2.5(g) RMS, 10-2000 Hz (random); three axes for 20 minutes each - IEC 60068-2-6 Shock 3(g) peak, three axes, 11mseconds for each axis - IEC 60068-2-27 Warranty 5 Year Limited Warranty MTBF >500,000 hrs MTBF (Nominal voltage, full load, T amb = +25 C (+77 F)) General Protection/ Safety Protected against short -circuit, overload, open circuit. Protection class 1 (IEC536), degree of protection IP20 (IEC 529) Safe low voltage: SELV (acc. EN60950) Over-temperature protection LED Alarm, Output shutdown with automatic restart Status Indicators Visual: 3 status LEDs (Input, Output, Alarm) Relay: SSR or dry relay contact, signal active when V out = 18.5 Vdc = +/-5% Installation Fusing: -Input Externally fused -Output Not fused. Output is capable of providing high currents (PowerBoost) for motor load startup. Mounting Simple snap-on to DIN TS35/7.5 or TS35/15 rail system. Unit should handle normal shock and vibration of industrial use and transportation without falling off the rail. Input: screw terminals, Wiring for the connector will be Ground on the left (when looking at the front of the unit),connector size range: Connections 9 16-10AWG (1.5-6mm 2 ) for solid conductors. Screw Torque: 4.4 lb-in (~ 50 N-cm). Output: connector size range, wire gauge 7-6 AWG (10.6-13 mm2) for solid conductors. Screw Torque: 15.6 lb-inch (~ 176 N-cm) for SDN40; all other models: 16-10AWG (1.5-6mm 2 ) for solid conductors. Screw Torque: 7 lb-inch (~ 80 N-cm) 1. SDN 20 will operate at 75% load; SDN 40 will operate at 50% load under loss of 1 phase; SDN 5 and SDN 10 will operate with single phase input power at 100% of load. Unit will shut down if thermal threshold is exceeded under this condition. 2. Unit passed input voltage overstress test at 600 Vac without failure. 3. Input current ratings are specified with low input, line conditions, worst case efficiency values and power factor spikes. Input current at nominal input settings will typically be half these values. 4. Losses are heat dissipation in watts at full load, nominal line. 5. 24-28 Vdc adjustable guaranteed at full load. 6. Ripple/noise is stated as typical values when measured with a 20 MHZ, bandwidth scope and 50 Ohm resistor. 7. SDN 20 and 40 unit will go to HICCUP mode. SDN 5 and 10 will maintain min 4 secs to deliver 150% load then drops to almost zero V out. The output voltage will immediately drop to almost zero when load rises above 150%. 8. All models except the 40amp unit are capable of parallel operation by use of a jumper pin, accessible by the end user. 40 amp unit will have active current sharing signal. 9. SDN 40-24-100C only = Output signaling terminal block features (Shut down, Power Good, Current Monitor, Current Balance, signal GND). 10. 70% maximum rated load.

Emerson brings integrated manufacturing solutions to diverse industries worldwide. Our comprehensive product line, extensive experience, world-class engineering and global presence enable us to implement solutions that give our customers the competitive edge. SolaHD is our premium line of power-conversion and power quality solutions products. For over 150 years, our electrical product brands have been providing a rich tradition of long-term, practical, high quality solutions with applications ranging from the construction and safe operation of petrochemical and process plants to providing quality power that precisely controls automotive robotic production. Engineers, distributors, contractors, electricians and site maintenance professionals around the world trust Emerson brands to make electrical installations safer, more productive and more reliable. The Appleton Group business unit of Emerson is organized into three focused groups that provide distributors and end users expert knowledge and excellent service. Electrical Construction Materials This group is made up of the Appleton and O-Z/Gedney brands. They manufacture a broad range of electrical products including conduit and cable fittings, plugs and receptacles, enclosures and controls, conduit bodies and industrial and hazardous lighting. Whether the application is hazardous location, industrial or commercial, the electrical construction materials group has the products to meet your needs. Power Quality Solutions The SolaHD brand offers the broadest power quality line, including uninterruptible power supplies, power conditioners, voltage regulators, shielded transformers, surge protection devices and power supplies. Heating Cable Systems This group is made up of the EasyHeat and Nelson brands. They offer a broad range of electrical heating cable products for residential, commercial and industrial applications. Asia/Pacific + 65.6891.7600 Australia + 61.3.9721.0348 Canada + 1.888.765.2226 China + 86.21.3338.7087 Europe + 33.3.22.54.27.54 Mexico/Latin America + 52.55.5809.5049 Middle East/Africa/India + 971.4.811.8100 United States + 1.800.621.1506 Appleton Group 9377 W. Higgins Road Rosemont, IL 60018 1.800.621.1506 solahd.com Appleton Grp LLC d/b/a Appleton Group. EasyHeat, Inc. is a wholly owned subsidiary of Appleton Grp LLC. All other product or service names are the property of their registered owners. The Emerson logo is a trademark and a service mark of Emerson Electric Co. Appleton Grp LLC. All rights reserved. 2016