Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS

Similar documents
RADIOGRAPHIC EXPOSURE

LECTURE 1 The Radiographic Image

Beam-Restricting Devices

X-RAYS - NO UNAUTHORISED ENTRY

1-1. GENERAL 1-2. DISCOVERY OF X-RAYS

STUDENT REVIEW QUESTION SET K CR/DR CONTENT AREA

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Contrast. Contrast: the difference in density on adjacent areas of a radiograph or other image receptor. Subjective. Long Scale (Low Contrast)

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Exposure System Selection

Visibility of Detail

X-RAY IMAGING EE 472 F2017. Prof. Yasser Mostafa Kadah

CR Basics and FAQ. Overview. Historical Perspective

DENTAL RADIOGRAPHY KAMARUL AMIN BIN ABU BAKAR

PD233: Design of Biomedical Devices and Systems

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT. Exam Content Specifications 8/22/2012 RADT 3463 COMPUTERIZED IMAGING

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

- KiloVoltage. Technique 101: Getting Back to Basics

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

Overview of Safety Code 35

INNOVATION BY DESIGN. Toshiba A History of Leadership REMOTE CONTROL R/F SYSTEM

10/3/2012. Study Harder

10/26/2015. Study Harder

Nuclear Associates , , , , , ,

SYLLABUS. TITLE: Equipment Operation I. DEPARTMENT: Radiologic Technology

Fabrício Sampaio Péres Kury Federal University of Rio de Janeiro Medical School

Essentials of Digital Imaging

The effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography

Artefacts found in computed radiography

MaxRay Handheld X-ray Systems Operator Training Exam

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

RULES OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF RADIOLOGICAL HEALTH CHAPTER USE OF X-RAY APPARATUS

Teaching Digital Radiography and Fluoroscopic Radiation Protection

Radiology. Radiograph: Is the image of an object made with use of X- ray instead of light.

The importance of radiation quality for optimisation in radiology

4. Contrast is the. There must The function of contrast is to:. The types of contrast are.

Digital Imaging Considerations Computed Radiography

Radiographic Testing (RT) [10]

1. Carlton, Richard R., and Arlene M. Adler. Principles of Radiographic Imaging: An Art and a Science, 5th edition (2013).

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

Nuclear Associates

X-ray Tube and Generator Basic principles and construction

Acquisition, Processing and Display

Photons interaction with matter

INTRODUCTION TO FLEXIBLE BRONCHOSCOPY. Fluoroscopy Synopsis HENRI G COLT MD SECOND EDITION THE BRONCHOSCOPY EDUCATION PROJECT SERIES

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

X-RAY. Lecture No.4. Image Characteristics:

3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development

COMPUTED RADIOGRAPHY (CR)

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.

Ludlum Medical Physics

Examination of Pipe Welds by Image Plate Based Computed Radiography System

China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW, 150kV Radiography System - HF50-R

Explain what is meant by a photon and state one of its main properties [2]

Course Instructions: Check your for your CE certification of completion (please check your junk/spam folder as well). About SMS CE courses:

Nuclear Associates

RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II

Ch. 223 VETERINARY MEDICINE CHAPTER 223. VETERINARY MEDICINE GENERAL PROVISIONS X-RAYS RADIOACTIVE MATERIAL. Authority

Seminar 8. Radiology S8 1

Small Animal Radiographic Techniques and Positioning COPYRIGHTED MATERIAL

BASICS OF FLUOROSCOPY

CARESTREAM INDUSTREX Digital Imaging Plates

Digital Imaging started in the 1972 with Digital subtraction angiography Clinical digital imaging was employed from the 1980 ~ 37 years ago Amount of

COMPUTED TOMOGRAPHY 1

10/15/2012 SECTION III - CHAPTER 6 DIGITAL FLUOROSCOPY RADT 3463 COMPUTERIZED IMAGING

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

LECTURE 20 ELECTROMAGNETIC WAVES. Instructor: Kazumi Tolich

Overview. Professor Roentgen was a Physicist!!! The Physics of Radiation Oncology X-ray Imaging

Principle of X-Ray Systems

Enhanced Functionality of High-Speed Image Processing Engine SUREengine PRO. Sharpness (spatial resolution) Graininess (noise intensity)

X-ray Tube and Generator Basic principles and construction

CARESTREAM INDUSTREX Digital Imaging Plates

Digital Imaging CT & MR

QC Testing for Computed Tomography (CT) Scanner

Nuclear Associates

Digital radiography. bucky table and wall stand as a dual detector or wireless system. Amadeo DR Systems

Comparison of computed radiography and filmõscreen combination using a contrast-detail phantom

SYLLABUS. 1. Identification of Subject:

Essentials of Digital Imaging

Current technology in digital image production (CR/DR and other modalities) Jaroonroj Wongnil 25 Mar 2016

MXHF-1500RF is controlled by Digital key panel console that displays KV, ma and mas with APR menu programmed.

DIGITAL RADIOGRAPHY ARTIFACTS

A Comprehensive Review of Image Production

U.S. ARMY MEDICAL DEPARTMENT CENTER AND SCHOOL FORT SAM HOUSTON, TEXAS PRINCIPLES OF RADIOGRAPHIC EXPOSURE SUBCOURSE MD0952 EDITION 200

Digital Image Processing

STUDENT REVIEW QUESTION SET I RANDOM CONTENT AREA RADT 2913 COMPREHENSIVE REVIEW

DIAGNOSTIC ACCREDITATION PROGRAM. Radiology and CT Quality Control Procedures Workbook

Half value layer and AEC receptor dose compliance survey in Estonia

Dental Radiography. One of the problems of dental radiography is having different dimensions than normal.

Diffraction-enhanced X-ray Imaging (DEXI) Medical Solutions. More information using less radiation

Photomultiplier Tube

Exposure Indices and Target Values in Radiography: What Are They and How Can You Use Them?

JEFFERSON COLLEGE COURSE SYLLABUS BET220 DIAGNOSTIC IMAGING. 3 Credit Hours. Prepared by: Scott Sebaugh Date: 2/20/2012

Sarah Hughes, MS, DABR Radiation Safety Officer

Digital radiography: Practical advantages of Digital Radiography. Practical Advantages in image quality

P R E S E N T E D B Y. K A M A R U L A M I N A B D U L L A H Dip. MED. IMG., BSc. MED. IMG. (UiTM)

ProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX.

Transcription:

Veterinary Science Preparatory Training for the Veterinary Assistant Floron C. Faries, Jr., DVM, MS

Radiology Floron C. Faries, Jr., DVM, MS

Objectives Determine the appropriate machine settings for making a radiograph Describe essential radiograph accessories Describe the positions used to perform radiographs from different views Describe safety precautions and discuss their importance

Terminology X-ray tube of radiograph machine Vacuum tube Cathode emits electrons Anode collects electrons Metal target on anode Electron beam (electrical current) perpendicularly directed X-rays (photons, radiation) emitted Patient s tissues absorb Strike patient and redirect (scatter radiation) High voltage power source 30-150 kilovolts (kv)

Milliamperage (ma) Unit of measure Controls amount of emitted x-rays ma x exposure time (S) = mas Kilovoltage peak (kvp) Value of voltage Controls radiographic contrast of image High mas and low kvp = black and white image Too high mas = black image (over-exposed) Too low kvp = white image (under-exposed) Low mas and high kvp = gray image

Source to image distance (SID) Distance from anode to receptor (film, plate) Increase distance = decreases beam intensity Lightens images Requires increasing mas settings Decrease distance = increases beam intensity Darkens images Requires reducing mas settings Reduces radiation exposure to patient

X-ray scatter control (reduces x-ray dose exposure to patient and x-ray scatter) Filtration device on x-ray tube Filtration device of lead strips (x-ray grid) Between anode and receptor (film, plate) Requires increasing mas settings Requires increasing kvp setting for large animal thorax

Determination of Machine Settings Measure thickness of patient s part Caliper instrument in centimeters Use technique chart for thickness measurement Position machine settings kvp ma Exposure time Set distance Set needle of voltage line meter 1/16 inch above center line Insures constant voltage coming into machine

Radiographic Positions Head, neck, body, tail Dorsal top view Ventral bottom view Lateral side view Leg Anterior front view Posterior back view Lateral outer side view Medial inner side view Two views One plane 90º angle to first view

Imaging Modalities Film/Screen Combinations Cassette holds film inside Image produced on film x-ray image (not visible) Film development image visible Chemical, water, and drying times Computer Radiology (CR) or Digital Radiography (DR) Cassette holds phosphor plate Image produced on plate x-ray image (not visible) Plate development image visible Plate in reader laser reads and digitizes into digital image Digital image sent to computer for viewing and storing Plate erased and refreshed for reuse by exposure to light

Computerized Axial Tomography (CAT) or Computerized Tomography (CT) Scan Utilizes x-rays Produces cross-sectional images of soft tissue and bone Ultrasonography (Ultrasound) Utilizes sound waves Produces images (sonograms) of soft tissues Motion images Still images Magnetic Resonance Imaging (MRI) Scan Utilizes radio waves Produces images in any plane of body

Images and Tissue Density Black image air Gray image soft tissue White image bone, minerals, sand, metal, dental enamel

Patient Motion Voluntary motion (controlled motion) restraint necessary Looking around Moving away Moving extremeties Paddling Pushing away Involuntary motion (uncontrolled motion) reduce exposure time, increase ma Heart beating Breathing Panting Discomfort moving

Heart, lungs, and thorax images Animal inhales make exposure Abdomen, pelvis, and spine images Animal exhales make exposure

Safety Devices and Precautions Remove anyone from the x-ray room that is not needed. Every person should wear a lead apron and lead gloves when holding the x-rayed animal. Check the condition of gloves and aprons periodically by using radiography to determine if they allow x-rays to pass through. Limit the beam to the size of the film with a cone or lead diaphragm. Do not direct the x-ray beam into another room or work area. Install an aluminum filter (1 to 2 mm thick) at the tube housing opening to eliminate radiation from useless wave lengths. Cover the bottom side of the x-ray table with lead to protect the feet. The hands should not be placed in the path of the direct beam. Do not use fluoroscopy when radiography will do the job. Fluoroscopy is more hazardous and requires additional safety precautions.

Lead Gloves and Aprons To help prevent deterioration of lead gloves and lead aprons: Roll or drape apron over curved surface rather than folding it. Store gloves by hanging or by placing cans with both ends open inside gloves to keep the gloves open and to allow moisture to evaporate.