Better system sensitivity through preamplifiers

Similar documents
Measurement of conducted EMI when using a switching power supply

EMC / Field strength Signal generation and analysis

EMI Test Receivers ESIB

R&S ZV-Z5x Calibration Units Specifications

EMC / FIELD STRENGTH Test receivers. Fast and straightforward: diagnostic and precompliance measurements with the R&S ESRP

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

STC Test Report. Date : Page 1 of 13 No. : HM161169

FCC PART TEST REPORT. Weccan Industrial Limited

Radiated Spurious Emission Testing. Jari Vikstedt

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

CENTRE OF TESTING SERVICE INTERNATIONAL

Advanced Compliance Solutions, Inc FAU Blvd, Suite 310 Boca Raton, Florida (561)

FCC PART & IC RSS GHz FHSS TEST REPORT

R&S ZV-Z5x Calibration Units Specifications

Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E

Measurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna

Voltage Sensors URV5-Z

EXHIBIT 10 TEST REPORT. FCC Parts 2 & 24

FCC PART 15B TEST REPORT SZ DJI TECHNOLOGY CO., LTD

Reducing Uncertainty in EMC Measurements

Specification for Conducted Emission Test

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 2.8GHz.

TRANSMITTER MODEL: KAS-2030M

Palstar, Inc. EMC TEST REPORT FOR. HF LDMOS Amplifier Model: LA-1K. Tested To The Following Standard: FCC Part 97 Subpart D. Report No.

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

Spurious Emissions & Emission Mark Report

The Value of Pre-Selection in EMC Testing. Scott Niemiec Application Engineer

APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 FCC ID: 2AAZPAC8

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd

For. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS

Utilizzo del Time Domain per misure EMI

TEST REPORT... 1 CONTENT...

15.247(d) RF Conducted Emissions & Band Edge

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz

EMC TEST REPORT RADISYS CORPORATION. Tel: Fax:

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

Compliance Engineering Ireland Ltd

Content. Report No. SH Page 2 of 22

Spectrum and signal analyzers for every requirement an overview

Handheld Spectrum Analyzer R&S FSH khz to 3 GHz

APPROVED BY: DATE: 19-Aug-2011 Brian Boyea, EMC Engineer. TESTED BY: DATE: 12-Aug-2011 Arturo Ruvalcaba, EMC Engineer

Itron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards:

Advanced Test Equipment Rentals ATEC (2832)

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

Spectrum Analyzers 2680 Series Features & benefits

T E S T - R E P O R T. Test Report No (Edition 1) for RF340-R. Inductive Tag Reader

Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI Report Constructed by: Zach Wilson, EMC Technician Signature: Date: June 21, 2017

FCC Radio Test Report

TEST REPORT FOR GSM TESTING

R&S ZN-Z5x Calibration Units Specifications. Data Sheet V03.00

T E S T - R E P O R T. No for. FHS 20/21 Typ 2 ASK 315 MHz. Remote Control Transmitter

F C C - TESTREPORT REPORT NO.: FCC-02/

EMC Precompliance Systems and Accessories Catalog

REPORT REVISION HISTORY...

FCC Radio Test Report. Orpak Systems Ltd.

MIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

Handheld Spectrum Analyzer R&S FSH 3

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Trade Name : Activision. Model Number: / FCC ID: XLU

R&S ZN-Zxxx Calibration Units Specifications. Data Sheet V04.00

HID GLOBAL CORPORATION

FCC REPORT. 570 E1 Camino Real #200, Redwood City, CA 94063, United Manufacturer:

Vector Network Analyzers ZVB

Handheld Spectrum Analyzer R&S FSH3

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

Verification On Behalf of Shenzhen Leer Chuang Technology Co., Ltd.

TEST REPORT FROM RFI GLOBAL SERVICES LTD

Dynamic Sciences International, Inc. Detection with Direction

MDS-21 Absorbing Clamp, EZ-24 Ferrite Clamp

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

FCC REPORT. Dongguan Hele Electronics Co., Ltd. J11, J12, J13, Q7, Q28, Q26, Q29

VCCI TEST REPORT. According to. V-3/ , TECHNICAL REQUIREMENTS, Class B ITE. Equipment : USB video camera. Model No. : V-U0017 / V-U0021

ENGINEERING TEST REPORT NUMBER: EUS1. ON Model No.(s): BB-BONE-000 IN ACCORDANCE WITH: CFR 47, PART 15, SUBPART B, CLASS B VERIFICATION

RADIO TEST REPORT. For MODEL NO FCC ID: C3K1703 IC ID: 3048A Test Report No. R-TR190-FCCIC-UNII-1 Issue Date: 14 September 2015

FCC Rules and Regulations / Intentional Radiators. Operational in the MHz, MHz, MHz, and

Test Report. Prepared for: Becker Avionics, Inc. Model: TG Description: Aeronautical basestation radio used for emergencies

FCC Test Report (TR )

9. MAXIMUM CONDUCTED OUTPUT POWER SPECTRAL DENSITY

King Pigeon Communication Co., Limited

TEST REPORT Part 95(A/B) & IC RSS-210(Issue 8)

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

EMI Test Receivers ESHS

Timing Considerations Using FFT-based Measuring Receivers for EMI Compliance Measurements

FCC Report for Parts ,

FCC TEST REPORT On Behalf of. Global Tech China Limited. Solar Light(Large)/28W,16W. Model No.: Additional Model No: Please Refer To Page 15

Calibration and Validation for Automotive EMC

FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U

Version TEST REPORT NO. DATE DESCRIPTION

TEST REPORT. : Masterbuilt Manufacturing Inc. 1 Masterbuilt Court Columbus, Georgia, 31907, USA

VCCI TEST REPORT. According to. Class B ITE. Equipment : USB video camera

FCC ID: B4OCC264BPA-S

Test specification: Section (e)(1), Radiated emissions below 40 GHz Test procedure: ANSI C63.4, Sections 8.3.2, 13.2, 13.4 Test mode: Compliance

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Wireless Speaker SRS-XB10 FCC ID: AK8SRSXB10

OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT

Accredited Standards Committee C63 - EMC

FCC Part 15B Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. FCC Part 15 Subpart B.

R&S ZVT Vector Network Analyzer Specifications

R&S FSC Spectrum Analyzer Specifications

Transcription:

EMC/IELD STRENGTH 4376/8 IG Whether with built-in or external preamplifier, the EMI Test Receivers R&S ESIB represent a superior complete test system, featuring excellent R and microwave characteristics. EMI Test Receivers R&S ESIB26 / R&S ESIB Better system sensitivity through preamplifiers High attenuation values significantly limit the sensitivity of a test system in the microwave range. Only the use of a broadband lownoise preamplifier makes it possible to fulfill the high sensitivity requirements defined for measuring radiated emissions (EMI) in compliance with standards. Measurements in line with standards mean high requirements The attenuation values and transducer factors of cables and antennas in the microwave range are so high that they considerably limit the sensitivity of a receiving system and thus the dynamic range for measurements. One solution is to use a broadband low-noise preamplifier directly on the antenna or before the receiver input which significantly improves the sensitivity of a test system. Only then is it possible to fulfill the high requirements placed on the Limit lines and transducer factors for the R&S ESIB ready for download; see page 46. sensitivity and performance of measuring instruments by test standards. Specifications for standard-conforming EMI emission measurements in commercial applications above GHz are defined in the basic standard CISPR 6- (999), which also defines requirements for the measurement environment and measuring instrument characteristics up to 8 GHz. Military applications are governed by standards such as the internationally recognized MIL-STD-46E and specifically parts RE02 and RE03 (RE: radiated emission) which requires EMI measurements up to GHz. 4 News from Rohde&Schwarz Number 78 (03/II)

EMC/IELD STRENGTH The EMI Test Receivers R&S ESIB26 and R&S ESIB (IG ) from Rohde & Schwarz offer superb R characteristics for sensitivity and dynamic range []. Equipped with the R&S ESIB-B2 option [2], both have an internal preamplifier (up to 26 GHz or GHz, respectively), which predestines them for measurements in line with the sophisticated MIL standard. Calculation of noise factor and noise figure Test systems for radiated emissions are fundamentally a cascade circuit consisting of receiving antenna, preamplifier, connecting cable and EMI test receiver, which in some cases is extended by an internal preamplifier (IG 2). The noise factor for this configuration can be calculated by subdividing the components into individual elements such as twoports and determining their separate contribution to the overall result. = n ( ) 2 3 n G G G2 G where i = noise factor of a given component G i = gain of a given component i = Within the equation, the third twoport will thus have a noise factor of 3 and a gain calculated from the two preceding values, G and G 2. Because an ideal, noise-free twoport has a noise figure of 0 db or a noise factor of, its contribution to the noise factor must yield zero. In the equation, this is expressed by: z = Calculation of noise factor The following example calculation of the noise factor is based on the setup shown in IG 2. Since a preamplifier cannot be placed in front of the receiv- i ing antenna, the first possible point of intervention is directly on the antenna output. The low-noise, broadband preamplifier must be dimensioned with respect to overload control in such a manner that it cannot be overdriven by broadband noise signal spectra and that it changes the antenna input parameters as little as possible. As a result, preamplifiers for frequencies up to 8 GHz, 26 GHz or GHz are relatively expensive. The noise factor for all four components connected after the antenna is calculated as follows on the basis of their noise factors and gain/attenuation G: = ( ) 2 3 4 G G G G G G 2 2 3 The numeric values in the following example calculation e.g. for 8 GHz are rounded up or down to obtain simple values that are easy to remember. The corresponding data sheets contain the exact specifications. The (dimensionless) noise factor of a twoport is the ratio of its S/N ratio at the input (S /N ) to the S/N ratio at the output (S 2 /N 2 ): S S N N = 2 2 This yields the noise figure N in db: N = 0 lg In addition, the noise factor and gain of twoports are a function of frequency, which means that the individual values for approximate calculations can be determined only for discrete frequency points. The noise factor of several twoports connected in series (IG 3) is obtained by adding together the noise factors of successive twoports while taking into consideration the gain G of each preceding port as shown in the following equation: IG 2 IG 3 Cascading of several twoports. Preamplifier Connecting cable Practical arrangement of twoports in EMI measurements. Internal preamplifier External preamplifier Connecting cable Internal preamplifier Test receiver, G 2, G 2 3, G 3 4 Noise figure N = f(f) Gain G = G (f) Noise figure N 2 = f(f) Gain G 2 = G 2 (f) Noise figure N 3 = f(f) Gain G 3 = G 3 (f) Noise figure N 4 = f(f) 42 News from Rohde&Schwarz Number 78 (03/II)

Preamplifier N = 3 db; = 2; Gain g = 30 db (G = 000) Cable RTK08 (IG 4) at 8 GHz N 2 = 5 db; 2 = 3.62; Attenuation a 2 = 5 db (G 2 = 0.0362) Internal preamplifier N 3 = 0 db; 3 = 0; Gain g 3 = db (G 3 = 00) IG 4 30 0 0 Utiflex Sucoflex RTK 08 3 5 8 0 8 26 requency / GHz Attenuation of cables with a length of meters. EMI test receiver N 4 = db; 4 = 00 This yields the following: 3. 62 z = ( 2 ) 000 0 00 000 0. 0362 000 0. 0362 00 = 0. 03062 0. 2846 0.03309 =.3465 = z = 2. 3465 Total noise figure N = 3.704 db Results from the calculation of the noise factor The example calculation shows that the noise of the entire circuit is determined primarily by the preamplifier characteristics. The subsequent components are largely insignificant due to the preamplifier s gain factor. Thus, the amplifier must not be overdimensioned (see also the comments regarding dynamic range on page 46). The choice of microwave cables is also important. The cables must be chosen with regard to optimum (minimum) length and attenuation. Long cables with high attenuation significantly increase the costs for improved sensitivity with preamplifiers. Investing several hundred to a thousand euros in suitable cables can eliminate the need for better amplifiers, which can cost up to 0000 euros depending on the frequency range. Cable length can be kept to a minimum in many cases by placing the test equipment located outside the anechoic chamber in a favourable position near the test antenna. Which amplifier for the given noise figure? When the minimum noise figure for the entire test system is in line with the test standards, the required preamplifier gain can also be determined. In the following example, the noise figure desired for the test system is 5 db. A preamplifier with a noise figure of N preamp = 3 db ( preamp = 2) is selected for the specified frequency range. The question is whether an amplifier with 0 db or db needs to be selected (G preamp 0 or 00). or example, the subsequent test receiver has a noise figure of N Rx = 5 db or Rx = 3.62. The following is obtained when these values are used in the simplified equation with a preamplifier preceding the test receiver: Rx z = ( preamp ) G preamp When G preamp = 0: 3. 62 z = ( 2 ) = 4. 062 0 = = 5. 062 z N =7.04dB When G preamp = 00: 3. 62 z = ( 2 ) =. 3062 00 = = 2. 3062 z N =3.62dB This shows that a noise figure of <5 db can be achieved only with a db amplifier. The criteria for using and selecting preamplifiers are thus as follows: The db preamplifier improves sensitivity from 5 db to 3.6 db, i.e. the dynamic range increases by.4 db at the lower end but decreases at the upper end. The maximum permissible input level with a db preamplifier decreases by db. Thus, the dynamic range loss is 8.6 db. Therefore, do not select more gain than absolutely necessary. Use an amplifier with suitable linearity. If broadband signals have high levels and a large occupied bandwidth, a preamplifier can be overdriven. Particular attention should 43 News from Rohde&Schwarz Number 78 (03/II)

EMC/IELD STRENGTH thus be paid to its linearity, especially when no preselection filters can protect the input stage of the measuring instrument. Attach a preamplifier directly to the antenna to ensure maximum increase in sensitivity. Use an amplifier with calibrated gain to minimize the measurement uncertainty of the entire system. What is the available dynamic range? 50 38 32 26 0 2 4 6 8 0 2 4 6 8 requency / GHz IG 5 Typical attenna factors for horn attennas. 60 56 52 48 5 25 30 35 requency / GHz When determining the minimum noise figure required for a complete test system, the dynamic range needs to be considered. or example, if the measurement bandwidth is MHz, the noise floor increases by 60 db in accordance with 0logRBW/ Hz. Due to the antenna factor, the dynamic range decreases further by approx. 45 db (at 8 GHz; see IG 5). IG 6 shows this reduction of the dynamic range as a result of a measurement bandwidth of MHz, the use of a preamplifier, allowance for antenna correction values as well as different detector types (peak or average value). The preamplifier reduces the permissible level at the test receiver input by 30 db, i.e. by its gain. The antenna correction factors represent attenuation values that require higher I gain, thus increasing the internal noise by the amount of the correction value, e.g. by 45 db. Thus, only high-quality test receivers with a basic dynamic range of approx. 00 db can be used for sophisticated measurements in line with test standards. The Test Receivers R&S ESIB26 and R&S ESIB feature these prop- IG 6 Numerous factors diminish the useful dynamic range. IG 7 Noise characteristic of the EMI Test Receiver R&S ESIB between GHz and GHz. Preamplifier 30 db m cable 5 db Max. permissible receiver input level Dynamic range Int. R attenuator 0 db Attenna factor 45 db Peak/AVG detector db RBW MHz / Hz 60 db Noise figure of measuring instruments db Noise 74 dbm 0 log RBW / Hz News from Rohde&Schwarz Number 78 (03/II)

State-of-the-art technology Low inherent noise Wide dynamic range Preselection preamplification Automatic overload control Pulse-protected 2nd R input ast overview measurements EMI measurements up to GHz conforming to standards Current standards Correct weighting of pulses to CISPR 6- and VDE 0876 All commercial and military standards like CISPR, EN, ETS, CC, VDE, ANSI, VCCI, MIL-STD, VG, DE-STAN, and many others Straightforward operation Active colour LCD Analog level display for each detector (parallel operation) Split-screen display for detailed analysis Receiver-oriented operating concept allowing manual operation for the EMI Test Receivers R&S ESIB26/R&S ESIB in the frequency range 7 GHz to 26.5/ GHz The internal preamplifier (option System noise figure improved by R&S ESIB-B2) is used to extend the frequency range of the preamplifier (9 khz to Nominal gain db 8 db typ. 7 GHz) integrated as standard in the EMI Multistage configuration up to Test Receivers R&S ESIB26 and 26.5 GHz or GHz R&S ESIB in the microwave range up to Connection irrespective of operating 26.5 GHz or GHz. mode: analyzer or receiver The preamplifier is used to improve the input sensitivity of the receivers by approximately 8 db so that cable losses and antenna correction values can largely be compensated in the GHz range. erties large dynamic range and low inherent noise. These receivers are indispensable because they offer high reproducibility of measured values and the capability to generate reports, which also makes them ideal as reference test instruments in the full compliance class, i.e. for EMC compliance testing to different standards in the certification of electrical and electronic components, instruments and systems in the civil and military area. IG 7 shows the typical noise characteristics of the EMI Test Receiver R&S ESIB between GHz and GHz with an activated db preamplifier, MHz measurement bandwidth and average detector. Including the correction values specified in IG 5 for the various horn antennas yields the noise curve shown in IG 8, recorded with a peak detector. The measurement not only meets the MIL-STD-46E RE02-4 standard when performed with an internal preamplifier but is actually up to 0 db below the required limit line for maximum permissible emissions. The cable selected determines whether a lownoise preamplifier with corresponding gain must be used. Summary To meet the strict requirements of the standards for the measurement of radiated emissions up to GHz while taking into account the receiver, connecting cable and antenna, it is necessary to include dimensioning fundamentals such as the determination of noise factor described here. The criteria for cable selection and dimensioning as well as a suitable amplifier are to be determined on the basis of the parameters of the antennas and EMI test receiver that are used. The EMI Test Receivers R&S ESIB26 and R&S ESIB with built-in preamplifier option R&S ESIB-B2 up to 26.5 GHz or GHz represent a superior complete test system with excellent R and microwave specifications. They can be used to successfully perform compliance testing to standard. Volker Janssen IG 8 Noise curve (peak) at MHz measurement bandwidth and attenna transducer factors. Level / dbµv/m 00 MIL Standard 46E-RE02-4 More information and data sheet at www.rohde-schwarz.com (search term: ESIB-B2) 80 60 EMI Test Receivers ESIB Internal Preamplifier (Option R&S ESIB-B2) Data sheet R&S ESIB Data sheet R&S ESIB-B2 LIM MIL 46E-RE02- Peak RE02- Peak Limit LIM MIL 46E-RE02- Peak** RE02- Peak Limit 0 db MES MIL 46E-RE02 Max. Peak 0 2 3 4 5 6 8 0 30 requency / GHz REERENCES [] EMI Test Receivers ESI: EMI professionals through to GHz. News from Rohde & Schwarz (999) No. 62, pp 7 9 [2] EMI Test Receivers R&S ESIB26 / R&S ESIB: Internal preamplifiers for improved sensitivity above 7 GHz. News from Rohde & Schwarz (02) No. 73, pp 28 29 News from Rohde&Schwarz 45 Number 78 (03/II)