XSD Single Fiber series DWDM passive optical components

Similar documents
CWDM Single Fiber series

DWDM Dual Fiber series

Overview. Highlights. General Specification. Datasheet

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 16 Channels C27-C42 Dual Fiber DWDM Mux Demux 1U Rack Mount, LC/UPC

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET FMU-MD08E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 4 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

Cisco Prisma Optical Passive Components

Data Center & Cloud Computing DATASHEET. 100 GHz DWDM Passive Optical Add/Drop Multiplexers Data Center & Cloud Computing Infrastruture Solutions

FMU-MC09-A/B, Pair Packaged DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

WaveSmart Wave Division Multiplexing (WDM)

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 8 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

DATASHEET FMU-MC04E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

Optical Passives (ISP)

Prisma DWDM Passives. Features. Optical Passive Components

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

XM40-QD20LD-J 40-ch Multiplexer/Demultiplexer

16 Channels C21-C36 Dual Fiber DWDM Mux Demux, w/expansion Port 1U Rack Mount, LC/UPC

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

WaveReady 40- and 44-Channel Multiplexer/ Demultiplexer with Test Channel. MDX-40MD101CB and MDX-44MD101CB

On the subsequent pages, you will find the full, parameter-for-parameter comparison. If you have any questions, please contact Fiberdyne Labs.

WDM -Transmission V-1.

DATASHEET FMU-MC04E-A/B, Pair Packaged, w/expansion Port

CWDM Cisco CWDM wavelengths (nm)

Prisma and Laser Link DWDM Passives for LGX-Compatible Systems

Dense Wavelength Division Multiplexer (DWDM) 200 GHz Spacing, Multi-Channel, 2ch, 4ch, 8ch, 16ch, 20ch in PEACOC Flexible Tray

GT Channel Ultra Compact CWDM Mux & DeMux

WaveReady Multi-Degree Reconfigurable Optical Add/Drop Multiplexer WRS-05AD1C00B

WaveReady 8-Channel DWDM OSP Optical Add/Drop Multiplexer for Splice Enclosures. MDF-08MD1N0xB and MDF-08MD1Z0xB

WaveReady Single-Channel DWDM Add/Drop for OSP Splice Enclosure. MDF-01AD10xx0

WaveReady CWDM Add/Drop for OSP Splice Enclosure

Datasheet. 40ch DWDM Mux Demux + Monitor Port 1U Rack Mount, LC/UPC. Overview. Highlights

50/100 GHz, 100/200 GHz Passive Interleavers. IBC Series

Class 1 LED of 850 nm for (short-range) applications. Class 1 laser of 1300 nm for (medium-range) applications.

Passive WDM Networking

Datasheet. FMU-MC04-A/B, Pair Packaged 4 Channels Single Fiber CWDM Mux Demux, Plug-in Module, LC/UPC. Overview. Highlights

Optical Passives and Accessories

OPCOM100-DMU40 40-Channel DWDM. Mux/Demux. Typical Application. Figure.1 Point to Point Topology. Datasheet. Raisecom Technology Co., Ltd.

OPC1600 MUX WDM OADM SPLITTER

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

CWDM. DATA SHEET DB4133-E Issue L Page 1 of 8

Digital Return System

Dual & Single Fiber Compact CWDM Mux Demux

LEAD Fiber Optics PRODUCT CATALOGUE

Transceiver, Chassis Connectors, and Cable and Adapter Specifications

OPCOM100-DAD4D 4-Channel Bidirectional DWDM ADM. Typical Application. Figure.1 Chain Topology. Datasheet. Raisecom Technology Co., Ltd.

Headend Optics Platform (CH3000)

Odd. Even. Insertion Loss (db)

M-FP ISOLATOR PIGTAILS

Digital Return System

100GHz WAVELENGTH DIVISION MULTIPLEXER/ DEMULTIPLEXER (APMUX1100 / APDMX1100)

Optiva OTS-2 18 GHz Amplified Microwave Band Fiber Optic Links

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

Pluggable Transceiver Modules

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

Cisco ONS Metropolitan Dense Wavelength Division Multiplexing 100-GHz FlexLayer Filter Solution

Further more all functions as well available in splice trays or splice enclosures (-40 to 85 C)

Optical Passives (OSP)

CISCO ONS /100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM

OMxxDyy-100zz-ab:cd-(M5)-XXYY

CISCO DWDM GBICS. Figure 1. Cisco DWDM GBICs. Main features of the Cisco DWDM GBICs:

Pass Cisco Exam

LEAD Fiber Optics PRODUCT CATALOGUE

DWDM Mux/Demux product range

Optiva 18 GHz Unamplified Microwave (MW) Transport System

Wavelength Selective Switch (WSS) 1x9

Cisco s CLEC Networkers Power Session

MEMS Tunable Filter Products

Prisma II 1 GHz 1550 nm Transmitters

OptiSheath Advantage Sealed Terminal Solution for WDM Applications, UCA4-XX An Evolant Solutions Product

Table of Contents INTERCONNECTS / CABLE ASSEMBLIES / PATCH PANELS

MEMS Variable Optical Attenuator (VOA)

DWDM SFP 4.25Gb/s Transceiver 30Km Hot Pluggable, Duplex LC, 3.3v C Band 100-GHz DWDM DFB-LD PDSFP-96-1XX12-22F

Opti Max Optical Node Series

Why Using Fiber for transmission

IBER OPTIC ATTENUATOR (FC/UPC, SC/UPC,

DATASHEET G Data Center Interconnect (DCI) 100G Embedded DWDM (DWDM transciever in to Ethernet switch with no OEO transponder requirement)

Advanced Test Equipment Rentals ATEC (2832)

Prisma II Multi-Wavelength High Density Transmitter

Wave Division Multiplexing. Passive Mux/Demux Modules & Cables. Datasheet. Features. Overview. Typical 2-Channel Passive Mux/Demux Application

Variable Optical Delay Line

Cisco Prisma II Quad Optical Input Enhanced Digital Return (EDR) Receiver for Compact Segmentable Nodes

Keysight Technologies IL and PDL spectra with the N7786B Polarization Synthesizer and the N7700A Photonic Application Suite.

GainMaker 1 GHz High Output 4-Port Node with 40/52 MHz Split

Model 6944 and 6940 Node bdr Digital Reverse 4:1 Multiplexing System designed for Prisma II Platform

/ On the web: / Telephone: IS-FIBER (800)

Cisco Enhanced Digital Return (EDR) 85 System Compact Segmentable Nodes

Datasheet. SFP Optical Transceiver Product Features SFP-11D-K0P5B31. Applications. Description. SFP Single Fiber 550m transceiver 1G BX Ethernet

CWDM PLUS/MAX Series OVERVIEW KEY FEATURES AND BENEFITS TECHNOLOGY.

Exam : : Cisco Optical SONET Exam. Title. Ver :

FUSED COUPLER C OR L BAND

Pluggable Transceivers

Optiva Un-Amplified MW Transport 40 GHz System

from ocean to cloud SEAMLESS OADM FUNCTIONALITY FOR SUBMARINE BU

This appendix lists the system messages for Cisco Transport Planner. They are classified as:

Optiva OTS-2 Ka-Band RF Fiber Optic Links

Transcription:

XSD Single Fiber DWDM Series XSD Single Fiber series DWDM passive optical components Features Optimized for single fiber applications Simplified component interconnection system using standard dual patch cords eliminates most interconnection errors High number of connections over single fiber. Limited only by system power budget. Very low inter-channel attenuation ripple Modular design enables later expansion Lower attenuation models available on request (for specific channel configurations) Standard versions available from stock Loss optimized versions available on request Typical Applications Optimization of fiber use in fiber based data transfer Concurrent transmission of different data formats i.e. thernet, Fiber Channel, TDM Out of band monitoring, fiber integrity and performance monitoring Description XSDO4L-SB-Bxx XSDO8L-SA-Bxx XSDO8L-0-SB-Bxx XSDO8L-SA-Bx XSDO4L-SB-Byy Single fiber Single fiber Single fiber Figure 1 Multichannel single fiber connection examples

XSD Single Fiber DWDM Series 2 XSD is a series of passive optical components optimized for use in single fiber DWDM transmission systems. All standard ITU C band 100GHz filters from CH 10 to Ch 66 are available filters Ch 17 to Ch 59 are usually on stock. Any channel combination can be implemented. Channel combinations with at least 4 sequential channels are available also as low attenuation models on request. Number of bidirectional channels concurrently transferred over standard single mode fiber G.652 is limited only by overall system power budget. All components are add/drop type (OADM) so they can be daisy-chained. System using multiple wavelength ranges can be easily integrated using standard components. In standard devices each bidirectional data channel consists of two consecutive wavelengths, each transferring data in one direction. Standard versions are intended mainly for unamplified applications. Special versions with channel arrangement suitable for optical amplification that still support simple local connections are also available. Terminal connections are designed so that standard dual SM patch cords can be used to connect to standard transponder equipment (i.e. SFP). ach type of optical component is available in two versions with different connector placement and filter order (A & B, C & D, ). Use of both versions one at each side assures that attenuation between different channels is balanced and correct channel to client TX and RX is connected when standard patch cables are used. Ordering XSDO2L-0-SA-Bxx XSDO2L-0-SB-Bxx XSDO4L-0-SA-Bxx XSDO4L-0-SB-Bxx XSDO8L-0-SA-Bxx XSDO8L-0-SB-Bxx XSDO8L-0-SC-XCx XSDO8L-0-SD-XCx XSDO8L-0-SA-XBx XSDO8L-0-SB-XBx 2 wavelengths (single channel single fiber) OADM, LGX, LC/UPC, 100GHz 4 wavelengths (dual channel single fiber) OADM, LGX, LC/UPC, 100GHz 8 wavelengths (quad channel single fiber) OADM, LGX, LC/UPC, 100GHz 8 wavelengths (quad channel single fiber) OADM, LGX, LC/UPC, 100GHz, modified connector placement, custom channel plan 8 wavelengths (quad channel single fiber) OADM, LGX, LC/UPC, 100GHz, modified connector placement, custom channel plan, Loss optimized to If wavelengths are all sequential xx is replaced by channel number of lowest channel in the component. If channels are not sequential xx is replaced with list of channels separated by»/«. Bxx in above designation is used for 100GHz filter channel spacing. For custom channel plans in designation is only index to description marked with leading letter X and two hex digits. Any combination of standard 100GHz DWDM (ITU-T G.694.1) wavelengths combinations can be ordered with delivery time of up to 6 weeks (4 weeks typical). Devices are installed in standard LGX module that snaps into 1U rack mount bracket. Up to three LGX modules can be inserted in single 1U rack mount bracket. There is also a selection of unmanaged transponder modules that can be installed in place of LGX module. Managed transponders must be installed in separate rack mount enclosure.

XSD Single Fiber DWDM Series 3 Following are some standard versions. Designation Description Similar Cisco Device XSDO8L-SA-XC2 XSDO8L-SB-XC2 XSDO8L-SA-XC3 XSDO8L-SB-XC3 XSDO8L-SA-XC4 XSDO8L-SB-XC4 XSDO8L-SA-XC5 XSDO8L-SB-XC5 sided, version A, 100GHz channels 21 to 24 and 26 to 29 sided, version B, 100GHz channels 21 to 24 and 26 to 29 sided, version A, 100GHz channels 31 to 34 and 36 to 39 sided, version B, 100GHz channels 31 to 34 and 36 to 39 sided, version A, 100GHz channels 41 to 44 and 46 to 49 sided, version B, 100GHz channels 41 to 44 and 46 to 49 sided, version A, 100GHz channels 51 to 54 and 56 to 59 sided, version B, 100GHz channels 51 to 54 and 56 to 59 XSDO8L-SA-XC2 and XSDO8L-SB-XC2 are usually available from stock FLA-8-60.6= ITU-100 GHz 8 Ch, FLA-8-60.6= ITU-100 GHz 8 Ch, FLA-8-52.5= ITU-100 GHz 8 Ch, FLA-8-52.5= ITU-100 GHz 8 Ch, FlexMod FLA-8-44.5= ITU-100 GHz 8 Ch, FLA-8-44.5= ITU-100 GHz 8 Ch, FLA-8-36.6= ITU-100 GHz 8 Ch, FLA-8-36.6= ITU-100 GHz 8 Ch, Typical connections layouts Figure 2 XCDO10L-SA-Bxx - Single fiber Single side 10 channels DWDM OADM version A Figure 3 XCDO10L-SA-Bxx - Single fiber Single side 10 channels DWDM OADM version B Figure 4 XCDO8L-SC-Bxx - Single fiber Single side 10 channels DWDM OADM version C Figure 5 XCDO8L-SD-Bxx - Single fiber Single side 10 channels DWDM OADM version D ponent with lower number connections have same layout, without higher number ports

XSD Single Fiber DWDM Series 4 Technical Specifications Parameters XSD Single fiber 100GHz thin film DWDM OADM 1 2 3 4 6 8 10 12 16 Wavelength ITU G.671 100G C20~C60 nm Channel Spacing 100 GHz Channel Passband Lc + 0.11 (min) nm Passband Ripple 0.45 to band C-Band except channels nm Insertion Loss - to < 1.2 < 2 < 2.5 < 2.9 < 3.7 < 4.6 < 5.4 < 6.2 < 7.9 Insertion Loss - A/B pair < 2.3 < 3.2 < 3.6 < 4 < 4.9 < 5.7 < 6.6 < 7.4 < 9.1 Insertion Loss - to < 0.9 < 1.4 < 1.9 < 2.3 < 3.1 < 4 < 4.8 < 5.6 < 7.3 to for signals > 13.2 > 13.6 > 14 > 14.4 > 15.3 > 16.1 > 16.9 > 17.8 > 19.5 Isolation adjacent channel 24 Isolation non adjacent channel 40 Insertion Loss Temperature Sensitivity 0.01 / o C Polarization Dependent Loss 0.25 Polarization Mode Dispersion 0.15 ps Return Loss 50 Directivity 50 Maximum Power Handling 300 mw Operating Temperature -5 to 70 o C Storage Temperature -40 to 85 o C Operating Humidity 5~95 non condensing Storage Humidity 5~95 non condensing Termination Package Dimension Note: 1. IL and all PDL within Operating Temperature and with connectors. 2. ponents used compliant to GR1209 & GR-1221. LC connector 1U LGX Unit Different packing and lower Insertion loss versions are available on request.

5 XSD Single Fiber DWDM Series Low loss optimized designs XSD XB and XSD X XSD series components are available also in special multistage designs that are built with several additional wide band filters in order to optimize optical loss on selected paths. Available are versions with minimized I L either on to path for applications with many OADM add/drop sites connected in series, and with minimized I L on to Add/Drop path for applications with low power budget margin. Technical specifications for some standard devices are shown below. Parameters (No. of BPF) 4 X XSD Single fiber 100GHz thin film DWDM loss optimized OADM 8 XB 8 X 12 XB 12 X 16 XB 16 X Wavelength ITU G.671 100G C20~C60 nm Channel Spacing 100 GHz Channel Passband Lc + 0.11 (min) nm Passband Ripple 0.45 to band C-Band except channels nm Insertion Loss - to (max) < 3.1 < 3.1 < 4 < 4 < 4.9 < 4.9 < 5.8 Insertion Loss - to (min) < 1.8 < 1.4 < 1.8 < 1.8 < 1.8 < 1.4 < 1.8 Insertion Loss - to < 0.5 < 2.3 < 1 < 2.8 < 1.5 < 4.1 < 1 Insertion Loss - A-B pair < 4.9 < 4.5 < 5.8 < 5.8 < 6.7 < 6.3 < 7.6 to for signals > 13 > 13 > 13.5 > 13.5 > 14 > 13 > 13.5 Isolation adjacent channel 24 Isolation non adjacent channel 40 Insertion Loss Temperature Sensitivity 0.01 / o C Polarization Dependent Loss 0.25 Polarization Mode Dispersion 0.15 ps Return Loss 50 Directivity 50 Maximum Power Handling 300 mw Operating Temperature -5 to 70 o C Storage Temperature -40 to 85 o C Operating Humidity 5~95 non condensing Storage Humidity 5~95 non condensing Termination Package Dimension Note: 1. IL and all PDL within Operating Temperature and with connectors. 2. Typical values of I L at 25C are less than 70Max IL for I L >1. 3. ponents used are compliant to GR1209 & GR-1221. LC connector 1U LGX Unit Other custom versions are also available.

XSD Single Fiber DWDM Series XSD Single Fiber DWDM Series 6 Following are some typical examples of loss optimized devices. Designation XSDO4L-SA-X2 XSDO4L-SB-X2 XSDO8L-SA-XB2 XSDO8L-SB-XB2 XSDO8L-SA-X2 XSDO8L-SB-X2 XSDO8L-SA-XB3 XSDO8L-SB-XB3 XSDO8L-SA-XB4 XSDO8L-SB-XB4 XSDO8L-SA-XB5 XSDO8L-SB-XB5 Description sided, version A, 100GHz channels 21 to 24 Low Loss path sided, version B, 100GHz channels 21 to 24, Low Loss path sided, version A, 100GHz channels 21 to 24 and 26 to 29, Low Loss sided, version B, 100GHz channels 21 to 24 and 26 to 29, Low Loss sided, version A, 100GHz channels 21 to 24 and 26 to 29, Low Loss path sided, version B, 100GHz channels 21 to 24 and 26 to 29, Low Loss path sided, version A, 100GHz channels 31 to 34 and 36 to 39, Low Loss sided, version B, 100GHz channels 31 to 34 and 36 to 39, Low Loss sided, version A, 100GHz channels 41 to 44 and 46 to 49, Low Loss sided, version B, 100GHz channels 41 to 44 and 46 to 49, Low Loss sided, version A, 100GHz channels 51 to 54 and 56 to 59, Low Loss sided, version B, 100GHz channels 51 to 54 and 56 to 59, Low Loss Accessories XMR1 XMR1R XMR2R XMR1B XMR1G1 19 rack mounting bracket accommodates up to 3 LGX modules in 1U height 19 rack mounting bracket accommodates up to 3 LGX modules in 2U height, recessed 19 rack mounting bracket accommodates up to 6 LGX1 modules or 3 LGX2 modules in 2U height, recessed blank panel for 19 rack mounting bracket Cable guide bracket enables guiding and fixing of all optical cables when installed with rack mount bracket Optional Services Optical fiber measurements and qualification Design and integration of complete system including active equipment Custom design and OM production is possible for orders with typically at least 10 equal components. XNYA d.o.o Celovška cesta 172, 1000 Ljubljana, SI +386 1 5140610 http://www.xenya.si sales@xenya.si XNYA d.o.o