Technical Data VARIABLES

Similar documents
Technical Data VARIABLES

Technical Data VARIABLES

Linear Open Style Suspended Ceiling Installation Guide

Panel Grille Suspended Ceiling Installation Guide

Wood Squares Installation Guide

METALWORKS TARTAN PANELS General Installation Instructions

Standard Solo 8 planks in maple veneer with aligned 1/2 reveal create a panelized appearance. 1/2 Reveal. Plank thickness 5/8 (16 mm)

INTERIOR INSTALLATION

AXIOM Classic Trim. Assembly and Installation Instructions

AXIOM Classic Trim Installation Instructions

WoodWORKS Channeled Plank

WOODWORKS Access Hook-on System

SECTION INTERIOR FINISH CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS

ROCKFON System Olympia Plus

SIDING INFORMATION. Red Cedar Douglas Fir Redwood Alder. Hemlock Poplar Pine Oak

4300 Install Guide. Attention. Ceiling Accessories

AXIOM Classic Trim. Assembly and Installation Instructions 1. GENERAL

A collection of impressive natural wood veneered acoustical finishes.

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. International Version

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS

A. Provide all finish carpentry needed for a complete and proper installation.

A. All trim that has been damages, broken, or missing shall be repaired or replaced with material of the same size, shape, and type.

SECTION FINISH CARPENTRY PART 1 GENERAL. 1.1 SECTION INCLUDES A. Interior Finish Carpentry Work: 1. Refer to schedule at end of Section.

WOODWORKS. Linear Solid Panels. Installation Instructions CEILING SYSTEMS. 1. General

Olympia Plus Sports Ceiling Impact Class 1A

WOODWORKS Grille System

METALWORKS Concealed. Installation Instructions

SAGIREV Installation Manual

SECTION INTERIOR FINISH CARPENTRY

CARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)

2. Skid should contain the following: A door & jamb B casing C seal cover kit & D extension jamb set (if ordered), E hardware box.

INTERIOR INSTALLATION

SECTION INTERIOR FINISH CARPENTRY. A. Lumber grading agencies, and the abbreviations used to reference them, include the following:

Linear Wood Grille Ceiling Systems

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

FAF. Catalog Price List SEPTEMBER 1, FINE ART FRAMES LLC BY JESSE GOSLEN Floaterframes.com Toll free

Ash Brook Golf Course Scotch Plains, New Jersey

ADDENDUM NO. 1 THOROUGHBRED ROOM RENOVATION PHASE II DINING AREA MURRAY STATE UNIVERSITY, MURRAY, KY PROJECT #

SECTION ARCHITECTURAL WOOD CASEWORK

Rockfon System OlympiaPlus A Impact 1A

WOODWORKS Linear Solid Panels

WOODWORKS Linear Solid Panels

***************************************************************************************************************

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

B. American Society for Testing and Materials (ASTM):

Finished Products Guide

St. Monica Food Pantry

WOODWORKS Concealed. Assembly and Installation Instructions

A. ASTM D Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.

Hospital Grade Welded Ceiling System

OWAtecta. OWA metal ceilings. OWAtecta Metal ceilings

SECTION CARPENTRY

SUBMITTAL SHEET. Project Submittals by

MITCHELL FURNITURE SYSTEMS, INC.

GUIDELINE SPECIFICATIONS

XL MAX. Suspension System Data Center Ceiling Solutions. Assembly and Installation Instructions

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

EDUCATOR SERIES. Wood Casework Solutions For Life. Learning. Discovery.

B. Related Requirements: 1. Section "Interior Painting" for priming and backpriming of interior finish carpentry.

Music Area Casework General 1.01 Summary Related Sections Definitions Qualifications and Quality Assurance

ACME 50 Application Guide

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

WALL TO FABRICATED FLOOR

LOCKER SPECIFIERS GUIDE. The standard of excellence for business, industry and institutions. Lockers Cabinets Shelving

ARMSTRONG METALWORKS BAFFLES Installation Guide

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

A. Boards or Strips: Lumber of less than 2 inches nominal size in least dimension.

PROJECT INSTRUCTIONS Roofing

Commercial Grade Welded Ornamental Steel Fence

Trim (Aluminum Substrate)

ARCHITECTURAL STICK SYSTEMS

Classic Exposed Tee System (24" x 24", 24" x 48", and 24" x 72") Floating Clouds and Perimeter Wall Attachment

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

WOODWORKS Walls. Installation Instructions WALL

Endura-Classic Craftsman Information

ROOFING City of Grand Rapids Building Safety Division

SECTION ARCHITECTURAL WOODWORK

make innovative projects.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION METAL LOCKERS

Acoustical Surfaces, Inc.

metalworks Vector Assembly and Installation Instructions

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

SECTION INTERIOR ARCHITECTURAL WOODWORK

Tools needed. Supplies Needed

SLATTEX (Textured Slatwall) INSTALLATION GUIDE

Apartment Dining Table

Installation Manual for Thermo Panel

metalworks Plank Assembly and Installation Instructions 2.1 Read this entire document before proceeding with installation.

Connector Technology, Shelf Supports Connection Fittings

SECTION HOLLOW METAL DOORS AND FRAMES

VERSAROC CEMENT BONDED PARTICLE BOARD ROOF SHEATHING VERSAROC CEMENT BONDED PARTICLE BOARD ROOF SHEATHING

TRINITY SURFACES PORTFOLIO HARDWOOD WALL PLANKS

DYNEX SOFFIT SYSTEM. Product. Scope. Building Regulations. Appraisal No. 908 [2016] Appraisal No. 908 (2016) BRANZ Appraisals

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

LuxCore Installation Instructions

FT DIX ELEMENTARY SCHOOL PHASE VII, CLASSROOM ADDITION PEMBERTON TOWNSHIP REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5349A

INSTALLATION, I O OPERATION & MAINTENANCE M A N U A L. Flowline. Architectural Linear Diffusers

DIVISION 6 WOOD AND PLASTICS

Attachment A BURLINGTON NORTHERN SANTA FE SPECIFICATIONS FOR CROSS TIES AND SWITCH TIES I. GENERAL

Installation guide. ROCKFON VertiQ. ROCKFON System T, ROCKFON System HAT. Impact-resistant and high impact-resistant acoustic wall panel solutions

Transcription:

Overview SYSTEM Rulon Linear Closed wood ceilings are designed with wood boards suspended parallel to the floor with lap joints and produces a 1/4 overlap between boards. The closed style gives an all-wood shiplap appearance. The system utilizes the Rulon Cliprail system eliminating heavy metal framing and support typically required to suspend nailed-in-place boards. Wood boards are installed continuously with tongue & groove ends to create a continuous, monolithic appearance. Standard lengths are 3-10. Linear Closed is available in only solid wood.

Technical Data VARIABLES ENGINEERING CONSIDERATIONS Linear Closed is manufactured at Rulon s plant in St. Augustine, FL. The Linear Clip H is a proprietary attachment method utilized by Rulon, and is simple for installers. All shop drawings and coordination details are produced by Rulon s engineering staff. ACCESSIBILITY Clips are mechanically fastened to both wood boards and heavy duty grid; removing wood boards would damage them. Primary Access Panels I can be coordinated and cut in-field. Limited access is available. ACOUSTICS Linear Closed is manufactured with lap joints between wood boards eliminating reveals to the plenum space beyond. Linear Closed systems provide a reflective surface. SUSTAINABILITY Linear Closed may contribute as required to the following LEED v4 credits: MR BPD&O Sourcing of Raw Materials, MR BPD&O Material Ingredients, EQ Low-Emitting Materials, EQ Minimum Acoustic Performance FIRE PERFORMANCE Linear Closed can be treated to meet Class A requirements as per ASTM E-84. Solid wood is treated with a finish additive. SEISMIC Linear Closed meet seismic code compliance via direct screw attachment to heavy duty grid. Local code requirements should be consulted in order to determine additional requirements. INTEGRATIONS Linear Closed can be easily trimmed in-field to accommodate MEP integrations. Touch-up finish is supplied to seal cut sections. In-factory cutouts can be achieved with dedicated coordination and in conjunction with the Integrated Lighting D program at Rulon. GENERAL COSTING Linear Closed is typically the one of the most economical systems depending on the material and manufacturing requirements and qualifies as $$$$ on the general costing scale. Local reps should be contacted in order to obtain a project-specific budget.

Specification COMPONENTS HANGERS #12- gauge wire hangers (contractor-supplied). SUSPENSION & ATTACHMENT Rulon cliprails are made from galvanized steel and are 12 feet long. They are factory-fabricated with Linear Clips H assembled onto standard heavy-duty 15/16 grid. The clips are made of spring-steel, with phosphate pretreatment and a corrosion-resistant coating. The assembled cliprails are provided by Rulon as part of the system. PROFILES Wood boards are 3/4" [19 mm] thick, with 4-1/4" [95 mm] face resulting in a 4" [102 mm] module. Sides of the wood boards are machined with male/female lap joints. PERIMETER TRIMS Ceiling termination at a wall or soffit is accomplished using Rulon perimeter trim #101 (see drawing LCC4N004). The standard perimeter for floating ceilings is Linear boards, turned 90 and pin-nailed into ceiling boards. CLAMPING TOOL A clamping tool can be used for rapid and easy assembly of wood boards to the cliprails (see drawing LCC4N002). WOOD SELECTIONS WOOD SPECIES Rulon Linear Closed may be specified in a variety of solid wood species. Current standard wood species are: Ash, Maple, Red Oak, White Oak, Beech, Poplar, and Cherry. Thermally Modified J wood species are also available. TEXTURES The standard surface texture is smooth-sawn. Faces are sanded. FINISHING & COMPONENTS WOOD FINISHES The standard finish is satin clear. Custom stains, opaque or semi-transparent colors are also available. All finishes are water based, low VOC-emitting, and do not contain solvents. SHIPPING & STORAGE SHIPPING Wood boards are shipped in 8-piece bundles, in shrink wrap packaging. Finished surfaces face one another to prevent marring.

STORAGE Linear Closed shall be stored flat and level, in a fully enclosed space. For a minimum of seventy-two (72) hours immediately prior to ceiling installation, the packaging shall be opened and the wood boards shall be stored in the room in which they will be installed. The temperature and humidity of the room shall closely approximate those conditions that will exist when the building is occupied. Wood boards must be stored off the floor. Typical Details 4 MODULE ASSEMBLY

Notes A B C D The Integrated Lighting program at Rulon is in partnership with GE Lighting and is an effort to coordinate MEPs more effectively and provide for a more streamlined process of integration. In practice, this effort begins with factory cutouts to accommodate light fixtures. E F G H The Linear Clip is a mechanical fastener that utilizes barbed inserts pressed into grooves in the backs of the wood boards creating positive attachment. The clips are made of spring-steel with phosphate pre-treatment and corrosion-resistant coating. I J Primary Access Panels are sections of a system that have been removed and assembled into a lift & shift panel for required-access locations. Thermally modified wood has been altered by a controlled process called pyrolosis which induces chemical changes to the cellular structure of the cell wall components of the wood material through heat to increase durability, shrink/swell factor, and biological resistance. K L