echnical data sheet Rotary actuator RF-MF(-O) Multifunctional rotary actuator with emergency control for and 3 way control ball valve orque Nm Nominal voltage AC/DC V Control: Modulating DC... V or variable Position feedback DC... V or variable Communication via Belimo -Bus Conversion of sensor signals RF-MF: deenergised NC RF-MF-O: deenergised NO echnical data Electrical data Nominal voltage AC V, /6 Hz / DC V Power supply range AC 9.... 8,8 V / DC.6... 8.8 V Power consumption In operation At rest For wire sizing. W at nominal torque W VA Connection Cable m, x.7 mm Parallel connection es Functional data Factory settings Variable Settings orque (nominal torque) Motor Spring-return Min. Nm at nominal voltage Min. Nm Control Control signal DC... V, input impedance kω Open-close, 3-point... Working range DC... V Start point DC.... 3 V End point DC.... 3 V... Position feedback (measuring voltage ) DC... V, max.. ma Start point DC.... 8 V End point DC.... V... ni-rotation ±% Direction of rotation Motor Spring-return RF-MF RF-MF-O Can be selected / Deenergised NC, ball valve closed (A AB = %) Deenergised NO, ball valve open (A AB = %) Direction of motion at = V In switch position or Electronically reversible... Manual override No Angle of rotation Max. 9 Running time Motor Spring-return 9 s / 9 < s @... C / max. 6 s @ 3 C 7... 3 s... Automatic adjustment of running time, Manual triggering of the adaption by Automatic adaption whenever operating range and measuring signal switching from to twice within s the supply voltage is switched to match the mechanical angle of rotation or with PC-ool. on, or manual triggering... Override control (with reference to the effective angle of rotation) Sound power level Motor Spring-return Service life Position indication Safety MAX (maximum position) = % MIN (minimum position) = % ZS (intermediate position, AC only) = % Max. 3 db (A) 6 db (A) Min. 6 emergency settings Mechanical Protection class III Safety extra-low voltage Degree of protection IP in all mounting positions EMC CE according to 89/336/EEC Mode of operation ype (to EN 673-) Rated impulse voltage.8 kv (to EN 673-) Control pollution degree 3 (to EN 673-) MAX = (MIN 3%)... % MIN = %... (MAX 3%) ZS = MIN... MAX... www.belimo.com
RF-MF(-O) Multifunctional rotary actuator AC/DC V, Nm echnical data (Continued) Safety Ambient temperature range... C emperature of medium... C (in the ball valve) Non-operating temperature... 8 C Ambient humidity range 9% r.h., non-condensating (to EN 673-) Maintenance Maintenance-free Dimensions/weight Dimensions See «Dimensions» on page Weight Approx. 6 g (without the ball valve) Safety notes Product features! Mode of operation Converter for sensors he actuator has been designed for use in stationary heating, ventilation and air conditioning systems and is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. It may only be installed by suitably trained personnel. All applicable legal or institutional installation regulations must be complied with. he device may only be opened at the manufacturer's site. It does not contain any parts that can be replaced or repaired by the user. he cable is not allowed to be removed from the unit. he device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. he actuator moves the ball valve into the operating position while simultaneously charging the return spring. he ball valve is turned back into the safety position by the application of spring energy when the power supply is interrupted. Conventional operation: he actuator is controlled with a standard modulating signal of DC... V and travels to the position defined by the control signal. Measuring voltage serves for the electrical display of the damper position... % and as slave control signal for other actuators. Operation on the -Bus: he actuator receives its digital positioning signal from the higher level controller via the -Bus and travels to the position defined. Connection serves as communication interface and does not supply an analogue measuring voltage Connection option for a sensor (passive or active sensor or switching contact). he actuator serves as an analogue/digital converter for the transmission of the sensor signal via -Bus to the higher level system. Parameterisable actuators Simple direct mounting High functional reliability Home position he factory settings cover the most common applications. Input and output signals and other parameters can be altered with the MF-H parameterising device or the BELIMO Service ool, MF-P. Simple direct mounting on the ball valve with only one screw. he mounting position in relation to the ball valve can be selected in 9 steps. he actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached. When the supply voltage is switched on, the actuator automatically detects its safety position (zero initialisation). his process, which takes place with the actuator stationary, lasts approximately s. RF-MF-O RF-MF L R Direction of rotation switch = = A AB = % Combination valve actuators Refer to the valve documentation for suitable valves, their permitted media temperatures and closing pressures. www.belimo.com
Multifunctional rotary actuator AC/DC V, Nm RF-MF(-O) Accessories Description Data sheet Electrical accessories Manual parameterising device MF-H - MF-H PC-ool MF-P - MF-P Position sensor SG.. - SG.. Digital position indication ZAD - ZAD Electrical installation Wiring diagram Conventional operation Operation on the -Bus Note Connect via safety isolation transformer.! Parallel connection of other actuators possible. Note the performance data. Control signal Measuring voltage Sensor Functions when operated on -Bus Connection on the -Bus Further actuators and sensors (max. 8) Supply and communication in one and the same 3-wire cable no shielding or twisting necessary no terminating resistors required Power topology here are no restrictions for the network topology (star, ring, tree or hybrid forms are permitted). Connection of active sensors Connection of external switching contact p Further actuators and sensors (max. 8) Further actuators and sensors (max. 8) Supply AC/DC A Output signal DC... V (max. DC... 3 V) Resolution 3 mv Switching current 6 ma @ V Start point of the operating range must be parameterised on the actuator as.6 V www.belimo.com 3
RF-MF(-O) Multifunctional rotary actuator AC/DC V, Nm Functions with basic values Override control with AC V with relay contacts a b c e.g. N 7 (DC... V) Functions a b c % Override control with AC V with rotary control switch 3 (DC... V) e.g. N 7 Pos % Functions ZS % (intermediate position) ZS % (intermediate position) % 3 % Control mode in accordance with Control mode in accordance with Remote control... % Minimum limit Z SGA SGF SGE Position sensor Z SGA SGF SGE Position sensor [V] (DC... V) min [%] Master/Slave control (position-dependent) Control with... ma via external resistance DC... V Ω () ()... ma DC... V o the following actuator DC... V Master actuator Slave actuator he Ω resistor converts the... ma current signal to a voltage signal DC... V Position indication Functional check ZAD Adapting the direction of rotation Procedure Apply AC V to connection and Disconnect connection 3: For direction of rotation : Actuator turns in the direction of For direction of rotation : Actuator turns in the direction of Short circuit connections and 3: Actuator runs in the opposite direction www.belimo.com
Multifunctional rotary actuator AC/DC V, Nm RF-MF(-O) Functions for actuators with specific parameters Override control and limiting with AC V with relay contacts a b c d e (DC... V) Functions a b c d e CLOSE ) Override control and limiting with AC V with rotary switch CLOSE ) MIN ZS MAX OPEN (DC... V) e.g. N 7 e.g. N 7 MIN ZS (intermediate position) MAX OPEN Control mode in accordance with ) Caution! his function is only guaranteed if the start point of the operating range is defined as min..6 V. 3-point control Open/close control a b RF-MF-O RF-MF e.g. N 7 a b L R Direction of rotation switch A AB = % A AB = % Dimensions [mm] Dimensional diagrams 8. 8 6 Further documentations Complete overview of actuators for water solutions Data sheets for butterfly valves Installation instructions for actuators and/or ball valves Notes for project planning (hydraulic characteristic curves and circuits, installation regulations, commissioning, maintenance etc.) www.belimo.com
. min. 8 6 8 min. X 736-.A RFD-MF (-O) (-) RF-MF (-O) (-) L H M DN Rp G PN mm AC V DC V DC... V DC... V RFD..(-O)(-) RF..(-O)(-) mm L H M X X R..K R3..K ³/₈ ³/₈ 3 8 8 8 R..K R..K ³/₈ ³/₄ 69 3. 3 8 8 R.. R3.. ¹/₂ ¹/₂ 67 39 9 8 R.. R.. ¹/₂ 7 38 9 8 R6..R R7..R ¹/₂ 6. 73 9 8
RFD.. (-) RF.. (-) R max. C max. C A B AB AAB= % BAB=% RFD..-O (-) RF..-O (-) AB A B AAB=% BAB=%