HYBRID RECORDER OUTLINE

Similar documents
µr SERIES RECORDERS VIEW RECORDERS 4365 & 4375 Recorders FUNCTIONS FEATURES

Easy-to-read in either English, French, or German; 20-digit, 2-line display; 6-channel simultaneous display possible

VIEW RECORDERS SPECIFICATIONS

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS

General Specifications

General Specifications

PROGRAM CONTROLLER OUTLINE

MICRO-CONTROLLER X (48mm 48mm)

SHIMADEN DIGITAL INDICATOR

General Specifications

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

SHIMADEN PROGRAM CONTROLLER

DPR100 C/D PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS

General Specifications

General Specifications

General Specifications

6/12/24 Dot Printing Model Smart Recorder SRF206/212/224

General Specifications

General Specifications

Fuzzy Temperature Controllers E5EF

General Specifications

General Specifications

MODEL: TC10EM. Temperature Controller TC10 Series

General Specifications

MICROJET RECORDER (100mm)

Process displays For standard signals, temperature, resistance measurement

DIGITAL PROGRAM CONTROLLER

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

General Specifications

General Specifications

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

High Performance Process & Temperature Controllers

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

REX-F400 REX-F700 REX-F900

Paperless Recorder PR20

MODEL: R30US4. Remote I/O R30 Series

MICRO-CONTROLLER X (48 48 mm)

Excellent low-cost Process & Temperature Controllers

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

PROCESS & TEMPERATURE CONTROLLERS

MODEL EPM-96 EPM-96F. ph 0 to ph14: Resolution 0.01pH 0 to 100 :Resolution temp. 1 (Selection display)

MICRO-CONTROLLER X mm

DIGITAL INDICATING CONTROLLER

Digital indicator for panel mounting With multi-function input Model DI25

BH Series 180mm CHART PEN-PRINTING TYPE HYBRID RECORDER

CompoBus/D-type Digital Controller

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

C1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

General. Specification FA-M3 F3CX04-0N. Temperature Monitoring Module GS 34M6H11-03E. General. Components and Functions. Model and Suffix Codes

ThermoPLUS Smart Temperature Transmitter

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

SHIMADEN PROGRAMMABLE CONTROLLER

PROGRAMMABLE CONTROLLER

General Specifications

SHIMADEN DIGITAL CONTROLLER

Fuzzy Temperature Controllers E5AF

General Specifications

SR100 (Multi-point Type)

Temperature measurement TMD 832 head transmitter

EX SERIES ELECTRONIC RECORDER

PROGRAMMABLE CONTROLLER

DC1010/DC1020/DC1030/DC1040

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

* Our controllers can be used with other brand of strain gauge sensors. Please contact RKC for more details. DO1 Control output (CH1)

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

DIGEM f 96 x 48 EK. Applications. Description

ADAM 4000/4100 Series


MODEL: 27HU-B 27-UNIT. [3] LED INDICATOR 0: Without 1: With (SIL not available)

1/16 DIN (48 48 mm) temperature controller PXR

CALYS 50. Field multifunction calibrator for basic use

APPENDIX APPENDIX A 1

Specifications. 744 Users Manual

MODEL: RZMS-U9. PC Recorders RZMS Series

Temperature Controller

MODEL: W2TS. Mini-MW Series

MICRO-CONTROLLER X (48 48 mm)

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

ONE CALIBRATOR ONLY MAIN FEATURES:

MICRO-CONTROLLER X (48 96 mm)

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

General Specifications

MICRO-CONTROLLER X (48 96 mm)

CALYS 75. Field documenting multifunction calibrator

General Specifications

v v PMA With numerous functions and robust construction, the KS 3930 A/B line recorders are ideal for universal industrial applications.

RZUS-U9 PC RECORDER MODEL. PC Recorders RZUS Series. (universal input, 12 points; isolated; bus-powered USB) MODEL & SUFFIX CODE SELECTION

Monitoring Relay MR 50

User s Manual. Models SR10001/SR10002/SR10003/SR10004/ SR SR10000 Recorder IM 04P03B01-01E. 3rd Edition. Yokogawa Electric Corporation

General Specifications

MEMOCAL 2000/2000S. Hand-held calibrator

DP2000 ORDERING GUIDE To Order MODEL NO.

CALYS 150. Advanced documenting multifunction calibrator thermometer

0 2 1 â Ó. itemp HART TMT182. Technical Information

MICRO-CONTROLLER X (96 96 mm)

Digital Indicator DS 96/48 PK

Transcription:

Specifications Sheet No.SPEC-33E (st Edition) RM0C HYRID RECORDER OUTLINE RM0C is 00mm calibrated hybrid recorder in a 44x44 DIN front panel and short depth of 50mm case housing. The recorder has versatility of universal input and scale in wide ranges and flexibility of user-reconfigurable unique functions. RM0C offers, continuous pen and 6 dot point models. FETURES Short case depth size of 50mm IP65: Dust-proof, Water-proof Wide LED with 8mm heights display llows user-selected consumables RS-3C communication interface in standard specifications UL, C-UL, CE approved Weights only.5kg (Multipoint type) Optional portable housing case available SPECIFICTIONS Input signal DC voltage: ± 0, 0 ~ 0, 0 ~ 50, ± 00 mv DC, ±, 0 ~ 5, ± 0 V DC Thermocouple:, R, S, K, E, J, T, C, u-fe, N, PR40-0, PLII, U, L Resistance temperature detector: Pt00, JPt00 DC current: 4 ~ 0m DC (with external shunt resistor: 50Ω <Charged: HMSU308>) Performance ccuracy: See RNGE TLE Dead band: Within 0.% (Pen Model only) Input impedance: 0MΩ min. in mv, TC input; 00kΩ min. in mv, TC input (with burnout protection); MΩ min. in Voltage input; 50Ω (External shunt resister) in m input llowable signal source resistance: 0kΩ max. in mv, TC input; 00Ω max. in mv, TC input (with burnout protection); kω max. in Voltage input; 0Ω max. per line in RTD input Normal mode reduction ratio: 60d min. (50/60 ± 0.Hz) Common mode reduction ratio: 40d min. (50/60 ± 0.Hz) Isolation resistance: 0.5kV DC 0MΩ min. between the each terminal and grounding terminal Dielectric strength:.5kv C for minute between power terminal and grounding terminal; 0.5kV C for minute between input terminal and grounding terminal; 0.kV C for minute between the input terminals Inter channel maximum noise voltage: 00 V C at 50/60 Hz Vibration resistance: 0 ~ 60Hz m/s max. Shock resistance: m/s max. Clock precision: ± 50ppm max. Chart feed accuracy: ± 0.% max. Structure Mounting: Panel mount llowable backward inclination: Within 30 Material (Color): Case, Polycarbonate (lack), Glass 0% UL94-V; Door, Polycarbonate, UL94-V (Clear) Dust-proof, Water-proof (Complies with the IEC59-IP65) Power Supply Voltage Power voltage (rated): 00 ~ 40V C Power voltage: 85 ~ 64V C Frequency (rated): 50/60Hz Frequency: 45 ~ 65Hz

Normal Operating Conditions mbient temperature: 0 ~ 50 C mbient humidity: 0 ~ 80%RH Supply voltage: 85 ~ 64V C larm (Relay output is optional) larm types: types(h,l),4 levels/channel larm output: 50 V C, 3 max. (resistance load) 5 V DC, 0.5 max.(resistance load) 30 V DC, 3 max.(resistance load) Hysteresis width: 0.5 ± 0. % Setting accuracy: ± 0.5 % Outputs: Pen Model, 3 point (uilt-in option, normally open); Multipoint Model, 6 point (uilt-in option, normally open) Safety Standard and EMI Standard Electrical safety: IEC00-,UL30- installation category II and pollution degree. UL30- Emissions: EN550 Group Class Immunity: EN5008- RS-3C (Standard): 00, 400, 4800, 9600 RS-485 (Option): 00, 400, 4800, 9600 DI function Function Description Chart Feed Start/Stop Close: Starts Open: Stops Change Chart Speed Close: Chart speed Open: Chart speed Comment Print Prints programmed characters (Multipoint model is up to 6 characters per line. Pen model is up to characters per line.) Manual Print Close: Start to print Date and Time Print Close: Start to print Up to 3 functions among above can be selected in one recorder. Option Chart sensor: Detects paper-out to output an alarm. Communication Interface INDIVIDUL SPECIFICTIONS lock Item Pen Model Multi point Model Input Measuring Point, 6 Unit Input Sampling 5ms 0s/6ch Display Interval.5s.5s Record Recording Form Disposable felt pen & Printing Form Wire dot (one color ink ribbon) Wire dot with 6-color ink ribbon Printer Recording Width 00 mm Step Response.0s max. to 95% of step-wise input - Dot Print Interval - 0s/ch (Note ) Chart Paper Length : 6m, Width : 4 mm Folding width : 40 mm (Note3) Chart Speed 5, 0, 5, 0, 5, 30, 40, 50, 60, 75, 80, 90, 00,0, 50, 60, 80, 00, 40, 300, 360, 375, 450, 600, 70, 750, 900, 00, 500, 800, 400, 3000, 3600, 4500, 4800, 5400, 6000, 700, 9000, 0800, 000 mm/h 0,,, 3, 4, 5, 0, 5, 0, 5, 30, 40, 50, 60, 75, 80, 90, 00,0, 50, 60, 80, 00, 40, 300, 360, 375, 450, 600, 70, 750, 900, 00, 50 mm/h (nalog recording is not done during the chart speed setting 0 mm/h.) Recording Color No. (Purple), No. (Red), No.3 (Green), pen (Red), pen (Green) (Note) No.4 (lue), No.5 (rown), No.6 (lack) Printing Color Purple Purple, Red, Green, lue, rown, lack Weight pen:.0kg max., pen:.5kg max,.5kg max. Power Consumption 30V max. (at 00VC) 5V max. (at 00VC) (Note ) User-changeable arbitrary colors with set-up configuration. (Note ) User-selective interval from 0, 0, 30 and 60 seconds. (Note 3) Clean Chart Paper: Length m

MESUREMENT RNGE The junction compensation accuracy is not calculated into digital readout accuracy and recording accuracy. The junction compensation accuracy is based on operating conditions: Temperature, 3 ± C; Humidity, 55 ± 0%RH; Power source 85 ~ 64V C; Frequency, 50/60Hz ± %; Warm-up time 30 minutes min.; No effect of vibration and shock of over recorder s resistibility. Junction compensation accuracy:, R, S, u-fe, PR40-0 ± C K, E, J, T, C, N, PLII, U, L ± 0.5 C Type DC Voltage/ Current Input Thermocouple Resistance Temperature Detector Range Measurement range ccuracy Measurement Digital Max. Resolution - 0.00 ~ 0.00mV ±(0.% of rdg + 3digits) 0µV 0.00 ~ 0.00mV ±(0.% of rdg + 3digits) 0µV 0.00 ~ 50.00mV ±(0.% of rdg + digits) 0µV - 00.0 ~ 00.0mV ±(0.% of rdg + 3digits) 00µV -.000 ~.000V ±(0.% of rdg + 3digits) mv 0.000 ~ 5.000V ±(0.% of rdg + digits) mv - 0.00 ~ 0.00V ±(0.3% of rdg + 3digits) 0mV 4 ~ 0m ±(0.% of rdg + digits) 0.0m 0.0 ~ 80.0 C ±(0.5% of rdg + C) (Note ) R 0.0 ~ 760.0 C ±(0.5% of rdg + C) (Note ) R 0.0 ~ 00.0 C ±(0.5% of rdg + 0.8 C) (Note ) S 0.0 ~ 760.0 C ±(0.5% of rdg + C) (Note ) K - 00.0 ~ 370.0 C ±(0.5% of rdg + 0.7 C) (Note 3) K - 00.0 ~ 600.0 C ±(0.5% of rdg + 0.4 C) (Note 3) K3-00.0 ~ 300.0 C ±(0.5% of rdg + 0.3 C) (Note 3) E - 00.0 ~ 800.0 C ±(0.5% of rdg + 0.5 C) E - 00.0 ~ 300.0 C ±(0.5% of rdg + 0.4 C) 0. C E3-00.0 ~ 50.0 C ±(0.5% of rdg + 0.3 C) J - 00.0~ 00.0 C ±(0.5% of rdg + 0.5 C) (Note 4) J - 00.0 ~ 400.0 C ±(0.5% of rdg + 0.4 C) (Note 4) J3-00.0 ~ 00.0 C ±(0.5% of rdg + 0.3 C) (Note 4) T - 00.0 ~ 400.0 C ±(0.5% of rdg + 0.5 C) (Note 4) T - 00.0 ~ 00.0 C ±(0.5% of rdg + 0.4 C) (Note 4) C 0.0 ~ 30.0 C ±(0.5% of rdg + C) u-fe.0 ~ 300.0K ±(0.5% of rdg + K) (Note 5) 0.K N 0.0 ~ 300.0 C ±(0.5% of rdg + 0.7 C) PR40-0 0.0 ~ 880.0 C ±(0.5% of rdg + C (Note 6) PLII 0.0 ~ 390.0 C ±(0.5% of rdg + 0.7 C) 0. C U - 00.0 ~ 400.0 C ±(0.5% of rdg + 0.5 C) (Note 7) L - 00.0 ~ 900.0 C ±(0.5% of rdg + 0.5 C) (Note 7) Pt00- - 00.0 ~ 650.0 C ±(0.5% of rdg + 0.3 C) Pt00- - 00.0 ~ 00.0 C ±(0.5% of rdg + 0. C) JPt00- - 00.0 ~ 630.0 C ±(0.5% of rdg + 0.3 C) 0. C JPt00- - 00.0 ~ 00.0 C ±(0.5% of rdg + 0. C) nalog ccuracy Digital accuracy ±(0.3% of span) Digital accuracy ±(0.3% of span) Digital accuracy ±(0.3% of span) Note : 400 ~ 600 C: ± C range under a span of 400 C: ccuracy is out of guarantee Note : 0 ~ 00 C: ± 3.7 C 00 ~ 300 C, ±.5 C Note 3: - 00 ~ -00 C: ± (0.5% of rdg + C) Note 4: - 00 ~ -00 C: ± (0.5% of rdg + 0.7 C) Note 5: ~ 0 K: ±.4 K Note 6: 0 ~ 300 C: ± 37.6 C 300 ~ 800 C, ±8.8 C Note 7: - 00 ~ -00 C: ± (0.5% of rdg + 0.7 C)

STNDRD FUNCTIONS CONFIGURLE FUNCTIONS Item nalog recording Digital display Logging print List print Engineering list print ffix print (Multipoint Model) Manual print Skip (Multipoint model) Programming Memory ackup larm Chart Speed Clock Indication Self Diagnostics Scaling Description Pen Models: Continuous pen tracing Multi point Model: Dot printing with 6- color ribbon cartridge Indicates channel no., process variable, date, chart speed, alarm set point in front display. Prints date, time, scale, chart speed, each channel s process variable and engineering unit at a programmed interval. Prints chart speed, type of input, range, engineering unit, alarm set point, comment print status, Printing description, logging print ON/OFF configuration, ZONE recording configuration, point focus configuration Prints configuration of channel/tag print switch, alarm print, logging print ON/OFF, reference time, interval, alarm hysteresis, burnout protection, scaling print ON/OFF, DI function (option) Prints Channel number besides analog recording line. Prints measured data by the front key operation. nalog recording stops during manual printing. bandon dot print of inputs as required. Programs chart speed, alarm set point, logging print interval, skip, date and time. ack-up for clock by built-in lithium battery for 0 years, 5 years in unpowered state. non-volatile memory stores configuration and calibration data. Sets types (H, L) of alarms per channel. Sets a total of 4 levels. Selects Chart speed from 4 types. Indicates Year, Month, Day, Hour and Minute. Sets the year in.d, and adjusts leap year automatically. Occurring some type of the defect to indicate ERROR. Indicates and record the input of a unification signal etc. is changed into the engineering scales. Function urnout protection Tag Number Temperature Compensation Copy Function Input offset ZONE Recording Point focus recording Decade Recording Indicating larm print larm recovery print Record start/end print Square root Integration Damping (Pen Model) larm Hysteresis Width Description Sets pointer at over 00% per inputs when input becomes open for T/C or ±50mV max. input. Tag number up to 5 characters for pen models/7 characters for multipoint model per channel can be programmed, and prints at logging print. Inside/outside of reference junction compensation (DE/DH connection) can be specified. Channel configuration data can be copied to another channel. Input offset per channel can be programmed. Recording on the chart track in specified range per channel. Recording by point focus to -crease line per channel. Records and indicates up to 5 decades. figures of effective number to indicate and print. Prints time, channel number, setting number and type of alarm in alarming. Prints recovery time, recovery channel number, setting number and type of alarm at recovery. Prints time and comment ( Start or End ) when record beginning or end. Square root available. Sum, balance, average among channels can be integrated. Digital filtering for measured data (PV) in unsteady process. Filter constant range ability:.0000 to 0.000 Formula is: k = 0.64/T I k = Filter constant T I = 99.5% damping larm hysteresis width can be programmed at 0% FS or 0.5% FS.

DIMENSIONS. 5 (Unit = mm) 4 4 3. 5 5 50 CH, NO. DT RUN LM ESC RUN MENU PRINT FEED ENT 7 max. (Panel thickness) 4 4 Panel Cutout (mm) 00 min. 38 + 0 00 min. + 38 0 TERMINL RRNGEMENT Multipoint Model Pen Model L N L N C C 3 3 C 4 4 C 5 5 C 6 6 C + C C 3 3 C + 4 + 4-4 5 + 5-5 6+ 6-6 C O M 3 C O M 3 + - + - 3+ 3-3 T D R D S G + - + - T D R D S G m V, V i n p u t T h e r m o c o u p l e i n p u t m i n p u t R T D i n p u t + + + - - + - + - + - b S hunt resistor R 5 0Ω <Charged HMSU308> Power Ground L N C I N

MODEL CODE NUMER 3 4 5 6 7 8 9 0 R M 0 C 0 Model 0 pen recorder 0 pen recorder 06 6 point recorder Communication (Note ) 0 RS-3C (Standard) RS-485(Option) Chart Sensor (Option) 0 None Yes DI/DO (Option) 0 None Relay output (Note ) 3 DI 3 3 DI + relay output (Note ) (Note ) Combination of RS-3C and RS-485 unavailable. (Note ) Nos. of relay outputs: 6 point recorder 6 relays; Pen recorder 3 relays CUTION Do not install this device before consulting instruction manual Specifications are subject to change without notice. For further information, a quotation or a demonstration please contact to: OHKUR ELECTRIC CO., LTD. Head Office / Factory Sales Offices URL e-mail (in English) Saitama, JPN Tokyo, Osaka, Nagoya, Kyushu, Tohoku http://www.ohkura.co.jp/ intsales@ohkura.co.jp Printed in Japan: ug. 006