Specifications and description Leuze electronic LSR 8 Throughbeam photoelectric sensors Dimensioned drawing,5 khz 0-30 V DC A 2 LS A²LS - active suppression of extraneous light Push-pull switching outputs M2 turning connector or cable connection Visible red light A B C D Transmitter/receiver Optical axis LED yellow 90 turning connector ISO 900 U L US C LISTED Electrical connection We reserve the right to make changes 8_a0e.fm IEC 60947... IEC 60947... Accessories: (available separately see page 74) M2 connectors (KD ) Ready-made cables (K-D ) Mounting systems Diaphragms Control guard IP 69K IP 67 Phone: 800.894.042 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
LSR 8 Specifications Optical data Typ. operating range limit ) Operating range 2) 2m Light source LED (modulated light) Wavelength 660nm (visible red light) Timing Switching frequency 500Hz Response time 0.33ms Delay before start-up 00ms Electrical data Operating voltage U B 0 30VDC Residual ripple 5% of U B Bias current 35mA Switching output/function /66 2 push-pull switching outputs 3) pin 2: PNP dark switching, NPN light switching pin 4: PNP light switching, NPN dark switching /44 2 PNP switching outputs pin 2: dark switching pin 4: light switching Signal voltage high/low (U B -2V)/ 2V Output current max. 00mA Sensitivity not adjustable Indicators LED yellow, receiver light path free LED yellow flashing, receiver light path free, no performance reserve Mechanical data Housing metal Optics cover glass Weight (plug/cable) 70g/40g Connection type M2 connector, 5-pin (turning), or cable: 2000mm, 5x0.25mm 2 Environmental data Ambient temp. (operation/storage) -40 C +60 C/-40 C +70 C Protective circuit 4) 2, 3 VDE safety class 5) II, all-insulated Protection class 6) IP 67, IP 69K 7) LED class (acc. to EN 60825-) Standards applied IEC 60947-5-2 ) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) The push-pull switching outputs must not be connected in parallel 4) 2=polarity reversal protection, 3=short-circuit protection for all outputs 5) Rating voltage 250VAC 6) In stop position of the turning connector (turning connector locked) 7) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test Tables without diaphragm: 0 2 20 with pin diaphragm in front of receiver ) : 0.8 2 with pin diaphragm in front of transmitter and receiver ) : 0 0.5 0.6 with slit diaphragm in front of receiver ) : 0 4.5 5 with slit diaphragm in front of transmitter and receiver ) : 0 2.5 3 Operating range [m] Typ. operating range limit [m] ) see remarks Diagrams Misalignment y [mm] 500 400 300 200 00 0-00 -200-300 y -400-500 0 5 0 5 20 Distance x [m] x Typ. response behaviour y Order guide Designation Part No. With M2 connector LSR 8/44-S2 Transmitter LSSR 8-S2 500 36354 Receiver LSER 8/44-S2 500 36356 With 2m cable LSR 8/44 Transmitter LSSR 8 500 36355 Receiver LSER 8/44 500 36357 With M2 connector LSR 8/66-S2 Transmitter LSSR 8-S2 500 36354 Receiver LSER 8/66-S2 500 36569 With 2m cable LSR 8/66 Transmitter LSSR 8 500 36355 Receiver LSER 8/66 500 36570 Remarks Smallest object for the complete operating range with - pin diaphragm: =0.7mm, - slit diaphragm: =.5mm Phone: 800.894.042 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
LSRL 8 Laser throughbeam photoelectric sensors Dimensioned drawing 2,8 khz 00m 0-30 V DC A 2 LS Laser, red light A²LS - active suppression of extraneous light Adjustable focus M2 turning connector or cable connection We reserve the right to make changes 8_a02e.fm ISO 900 IEC 60947... IEC 60947... Accessories: U L US C LISTED (available separately see page 74) M2 connectors (KD ) Ready-made cables (K-D ) Mounting systems Diaphragms Control guard IP 69K IP 67 A Receiver B Transmitter C Optical axis D Operational control E LED yellow F 90 turning connector Electrical connection Phone: 800.894.042 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
LSRL 8 Specifications Optical data Typ. operating range limit ) 00m Operating range 2) 60m Light spot diameter 0.mm adjustable (see diagrams) Focus adjustment range 40mm (see diagrams) Beam spread 0.5mrad Light source laser Wavelength 670nm (visible red light, polarised) Laser warning notice see remarks Timing Switching frequency 2800Hz Response time 0.8ms Delay before start-up 00ms Electrical data Operating voltage U B 0 30VDC Residual ripple 5% of U B Bias current 35mA Switching output PNP and NPN transistor output Function characteristics light switching Signal voltage high/low (U B -2V)/ 2V Output current max. 00mA Sensitivity adjustable with 270 potentiometer Indicators LED yellow, receiver light path free LED yellow flashing, receiver light path free, no performance reserve Mechanical data Housing metal Optics cover glass Weight (plug/cable) 70g/40g Connection type M2 connector, 5-pin (turning), or cable: 2000mm, 5x0.25mm 2 Environmental data Ambient temp. (operation/storage) -0 C +40 C/-40 C +70 C Protective circuit 3) 2, 3 VDE safety class 4) II, all-insulated Protection class 5) IP 67, IP 69K 6) Laser class 2 (acc. to EN 60825-) Standards applied IEC 60947-5-2 ) Typ. operating range limit: max. attainable range without performance reserve, focus = 2) Operating range: recommended range with performance reserve, focus = 2m 3) 2=polarity reversal protection, 3=short-circuit protection for all outputs 4) Rating voltage 250VAC 5) In stop position of the turning connector (turning connector locked) 6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test Tables without diaphragm: 0 60 00 with pin diaphragm in front of receiver ) : 0 8 0 with slit diaphragm in front of receiver ) : 0 6 20 Operating range [m] * Typ. operating range limit [m] ** * for focus adjusted to 2m ** for focus adjusted to ) see remarks Diagrams Diameter [mm] 00 0,0 A B C 0, 0 0, 0,3 0,5 2 3 4 6 8 0 6 A focus = 0.25m B focus = 2m C focus = 6m Typ. light spot Distance [m] Order guide Designation Part No. With M2 connector LSRL 8/24.9-S2 Transmitter LSSRL 8.9-S2 500 36358 Receiver LSERL 8/24.0-S2 500 36359 With 2m cable LSRL 8/24.9 Transmitter LSSRL 8.9 500 37083 Receiver LSERL 8/24.0 500 37084 Remarks Smallest object for the complete operating range with - pin diaphragm: =0.7mm, - slit diaphragm: =.0mm Phone: 800.894.042 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Specifications and description Leuze electronic ILSR 8 Throughbeam photoelectric sensors Dimensioned drawing A 2 LS A²LS - active suppression of extraneous light Integrated AS-i slave M2 turning connector or cable connection Visible red light A B C D Transmitter/receiver Optical axis LED yellow 90 turning connector ISO 900 Electrical connection We reserve the right to make changes 8_a04e.fm IEC 60947... IEC 60947... Accessories: (available separately see page 74) M2 connectors (KD ) Ready-made cables (K-D ) Mounting systems Diaphragms Control guard IP 69K IP 67 Phone: 800.894.042 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
ILSR 8 Specifications Optical data Typ. operating range limit ) Operating range 2) 2m Light source LED (modulated light) Wavelength 660nm (visible red light) Timing Switching frequency according to AS-i specifications (200Hz internally) Response time according to AS-i specifications (2.5ms internally) Delay before start-up 300ms Electrical data Operating voltage U B 26.5V 3.6V (according to AS-i specification) Bias current 35mA Sensitivity not adjustable Indicators LED yellow, receiver light path free LED yellow flashing, receiver light path free, no performance reserve Mechanical data Housing metal Optics cover glass Weight (plug/cable) 70g/40g Connection type M2 connector, 5-pin (turning), or cable: 2000mm, 5x0.25mm 2 Environmental data Ambient temp. (operation/storage) -40 C +60 C/-40 C +70 C Protective circuit 3) 2, 3 VDE safety class 4) II, all-insulated Protection class 5) IP 67, IP 69K 6) LED class (acc. to EN 60825-) Standards applied IEC 60947-5-2 AS-i data I/O code 7 ID/ID/ID2 Code A/7/E Address programmed by the user in the range of to 62 (default=0) Cycle time acc. to AS-i specification 0ms AS-i standard according to profile S-7.A.E (A/B-operation, user defined) ) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 2=polarity reversal protection, 3=short-circuit protection for all outputs 4) Rating voltage 250VAC 5) In stop position of the turning connector (turning connector locked) 6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test Tables without diaphragm: 0 2 20 with pin diaphragm in front of receiver ) : 0.8 2 with pin diaphragm in front of transmitter and receiver ) : 0 0.5 0.6 with slit diaphragm in front of receiver ) : 0 4.5 5 with slit diaphragm in front of transmitter and receiver ) : 0 2.5 3 Operating range [m] Typ. operating range limit [m] ) see remarks Diagrams Misalignment y [mm] 500 400 300 200 00 0-00 -200-300 y -400-500 0 5 0 5 20 Distance x [m] x Typ. response behaviour y Remarks Smallest object for the complete operating range with - pin diaphragm: =0.7mm, - slit diaphragm: =.5mm Order guide Designation Part No. With M2 connector ILSR 8/A.8-S2 Transmitter LSSR 8/A.8-S2 500 38787 Receiver ILSER 8/A-S2 500 38788 Phone: 800.894.042 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
ILSR 8 Throughbeam photoelectric sensors AS-i programming: transmitter LSSR 8/A.8-S2 DI 0 DI DI 2 DI 3 DO 0 DO DO 2 DO 3 Assignment: data bits Assignment: parameter bits Host level Sensor function Host level Sensor function P 0 P sensor not ready Ready P sensor ready 2 P 3 transmitter OFF transmitter ON Activation input DI (n) AS-i input DO (n) AS-i output AS-i programming: receiver ILSER 8/A-S2 DI 0 DI DI 2 DI 3 DO 0 DO DO 2 DO 3 Assignment: data bits Assignment: parameter bits Host level Sensor function Host level Sensor function object detected Switching output P no object 0 active dark switching Warning output P not active light switching Light/dark switching sensor not ready Ready P sensor ready 2 P 3 DI (n) AS-i input DO (n) AS-i output Phone: 800.894.042 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com