Reliable Power Meters Multipoint Power Recorder

Similar documents
Complimentary Reference Material

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 3540 FC Three-Phase Power Monitor

Fluke Three-Phase Power Recorder. Never miss capturing a disturbance - with the exclusive threshold-free measurement system, it s automatic.

Fluke 1750 Three-Phase Power Recorder

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

Pinpoint power quality problems faster

Fluke Advanced Test Equipment Rentals ATEC (2832) Three-Phase Power Recorder

Fluke Three-Phase Power Quality Recorder Topas. Class-A compliance for the most demanding power quality tests

Fluke 170 Series True-rms Digital Multimeters

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

Power Quality Analyzer Topas 2000

1587/1577 Insulation Multimeters

Fluke 83V and 87V Digital Multimeters

Pinpoint power quality problems faster

Troubleshooting. process loops. All. Application Note. Loop calibrators. ProcessMeter

Choosing the Right PowerSight Model

Fluke MDA-510 and MDA-550 Motor Drive Analyzer

Fluke Three-Phase Power Recorder. Plug and play: Set up in minutes with selfidentifying

6135A/PMUCAL Phasor Measurement Unit Calibration System

Choosing the Right PowerSight Model. Comparison Table between PowerSight models**

With any other power quality analyzer you re just wasting energy.

Power Analysis Summary

5080A Multi-Product Calibrator

5320A. Multifunction Electrical Tester Calibrator. Extended Specifications

Fluke Digital Multimeters Solutions for every need

Dranetz-BMI : the award-winning hand-held 3-phase power analyzer

Metering Devices, Protective Relays, Software and Connectivity

Fluke 8845A/8846A Digital Multimeters Extended Specifications

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM WHY BUY WHEN YOU CAN HIRE. Nationwide Low Call

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

IQ Analyzer 6400/6600 Series

Choosing the Right PowerSight Model. No matter what your needs or budget there is probably a PowerSight model that is right for you

5790A Automated AC Measurement Standard

Fluke 3540 FC Three-Phase Power Monitor

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals

1507/1503. Insulation Testers. Technical Data. Features and benefits:

Fluke Norma 4000/5000

Fluke 1587 FC/1577 Insulation Multimeters

3 Phase Power Quality Analy er

5520A. Multi-Product Calibrator. Extended Specifications 2005

5500A. Multi-Product Calibrator. Extended Specifications 2005

5522A Multi-Product Calibrator Extended specifications

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Fluke Norma 4000/5000

Fluke 430 Series II Three-Phase Power Quality and Energy Analyzers

ECE 528 Understanding Power Quality

POWER QUALITY MONITORING - PLANT INVESTIGATIONS

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications

DM-5 Power Quality Analyzer

Maintain power systems, troubleshoot power problems, diagnose equipment failures

E6000 E6000. Handheld Power Quality Analyzer. Features. Functions

Supervision and analyse of the electrical network EN50160 & POWER QUALITY

Network Analyzer for Low-, Medium- and High-Voltage Networks

5502A Multi-Product Calibrator. Extended specifications

PQube 3 Specifications

Installation Tester and DMM Kits

Fluke 712B and 714B Temperature Calibrators

UNIT-4 POWER QUALITY MONITORING

Electric Power Quality: Voltage Sags Momentary Interruptions

5520A. Multi-Product Calibrator. Extended Specifications

Measure voltage without test leads. Product Highlights

How adjustable speed drives affect power distribution

Oscilloscopes for field applications

MEASURING INSTRUMENTS AND TESTERS

Arbiter Systems, Inc Vendels Circle, Suite 121 Paso Robles, CA USA

The experience of the Qualistar ensuring high performance

Power Quality Recorders with Wireless Communications

Energy Explorer PROFESSIONAL POWER & HARMONICS ANALYSER

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Enabling Tomorrow s Technology Today

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators

ELITE PRO. Automation Components, Inc.

PQM3000 Class A rack 19 power quality analyzer for CTs or current clamps

Power Quality: Is my power good or bad?

Power quality report. A Manufacturing Plant

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Roadmap For Power Quality Standards Development

PQube 3 Specifications

Smart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

Fluke T5 Electrical Testers. Fluke T and T5-600 Voltage, Continuity and Current Testers

Fluke 1660 Series Multifunction Installation Testers

1650 Series Multifunction Installation Testers

Model 931A Power System Analyzer. Model 930A Three Phase Power Analyzer. Model 929A Three Phase Power Meter. with. Digital Signal Analysis

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

Power Quality and Circuit Imbalances Northwest Electric Meter School Presented by: Chris Lindsay-Smith McAvoy & Markham Engineering/Itron

Introduction to Harmonics and Power Quality

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Fluke 5820A Oscilloscope Calibrator Specifications

PQube 3 Firmware 3.5.0

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

PQ Monitoring Standards

QA-ES III Electrosurgical Analyzer

QA-ES III Electrosurgical Analyzer

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals

8845A/8846A 6.5 Digit Precision Multimeters

SIEMOS PQ The Multi-Functional Power Quality Analyzer for Low and Medium-Voltage Networks

Transcription:

Reliable Power Meters Multipoint Power Recorder High-speed capability for permanent installation Technical Data What is Full Disclosure Technology? Full Disclosure Technology is built into all Fluke and RPM three-phase power quality instruments. This technology makes the Multipoint Power Recorder a unique, professional instrument that increases your ability to maintain and troubleshoot your plant s power quality. Full Disclosure Technology uses patented sampling hardware and algorithms to record everything your loads see. The sampling system processes every cycle on all channels, recording min/max values and looking for sags, swells or waveform faults. The system can store 6000 events (up to 96,000 with Multi-session option). You can see everything from sub-cycle events to long-term outages with clear detail. Records power parameters, rms voltage, rms current, harmonics and monitors for power quality events on all channels simultaneously without having to reconfigure. No need to set thresholds. You won t be disappointed by missed events or a memory full of noise. Because there are no thresholds to set, Full Disclosure Technology system records any changes in measurements, even the ones that are almost out of tolerance. Full Disclosure Technology lets you plot events on any power tolerance curve. CBEMA, ITIC, and ANSI curves are included, or create your own. Full Disclosure Technology captures thousands of voltage events and related current information, without having to set thresholds.

Designed for permanent installations, Multipoint performs just like the portable Insite Power Recorder, simultaneously measuring all power quality parameters, as well as power consumption harmonics. The system consists of a detachable acquisition unit and a base that manages connections to your power system. 4 voltage channels - three phases plus neutralto-ground. 5 current channels allow you to monitor neutral and ground current in addition to phases Acquisition unit detaches from base with four screws, for easy calibration or maintenance of the measurement hardware. Measure and record Volts, Amps, frequency, Watts, VA s, VAR s, power factor, demand and harmonics using 128 samples per cycle on every cycle Capture up to 6,000 voltage events with simultaneous current, in each monitoring session Ethernet interface makes downloads fast and easy Models 1941 and 1948 are designed to connect to industry-standard 5- amp CT s Models 1942 and 1949 are designed for use with clamp on CT s or Flexi CT s Multi-session option allows for 16 sessions, effectively multiplying event capture capability to 96,000 events Models 1948 and 1949 feature a 2 MS/s sampling system for capturing and viewing highspeed transients Trend windows give you an overview of power parameters fast. Measurements are processed for every cycle. Min, max and average values are plotted so you can quickly see the worst-case. Real-time meters and vector diagrams display Watts, VA, VAR, power factor and displacement power factor. Real-time waveform displays show up to 9 channels (4 voltage, 5 current) including ground and neutral current. Track demand using averaging intervals from 5 minutes to 1 hour. Display harmonics up to the 63rd as a spectrum or a table. 2 Reliable Power Meters Multipoint Power Recorder

Standard Multipoint Measurement Features Basic Functions Logging RMS voltage and RMS current on all channels Phasor diagrams Frequency trends Real-time oscilloscope display of voltage and current on all channels 1652 Power Consumption Watts and demand trends (included) KWH, individual phases and total VA and VAR trends Power Factor trends, true and displacement Oscilloscope display of power meters for each phase 1653 Harmonics (included) Voltage and current THD trends Voltage and current imbalance Harmonic spectrum, phase, magnitude to 63rd harmonic Tracking of individual harmonics 1651 Power Quality (included) Voltage waveshape faults as short as 130 µs duration, 1000 V peak Voltage sags/swells Simultaneous current corresponding to correlated with voltage events Power tolerance curves 1658 High Speed Power Quality Voltage and current waveshape faults (included in 1948 and 1949) Voltage and current sags/swells Power tolerance curves Transients as short as 500 ns duration, 6400 V peak; with peak detect or detailed waveform graphs 1956 External CT Allows use of external RPM current transformers (included in 1942 and 1949) Multipoint Options 1662 Multi-Session Option Allows a recorder to store up to 16 measurement sessions Each session can consist of up to 6000 events, increasing the event storage to 96,000 1663 TCP/IP Option Enables Ethernet-equipped instruments to communicate via Internet With Multipoint high-speed models 1958 and 1948 gather detail on impulses as short as 500 ns. 1950 Multipoint Base Each 194X acquisition system requires a base unit. The 1950 base provides connection points to your power system. The 194x Acquisition unit can be removed for maintenance or calibration, without disturbing the distribution system. For systems using fixed, 5A CT s the base provides terminals for voltage and current. For systems using clamp-on CT s, the base provides voltage terminals. Software completes the system There are two software packages available for the Multipoint Power Recorder. Both packages provide seamless communication, with graphical display of power system parameters and the ability to manage power survey data. Power analyzer system software Offers optional Report Writer Software Offers Alarming and Polling Option Scenario software Includes facilities for comparing trends from multiple databases Calculates a Power Quality Index - a single figure of merit that characterizes the overall performance of a power system. The Power Quality Index allows you to trend system performance over time and determine whether a system is improving or degrading. Multipoint Power Recorder Reliable Power Meters 3

Specifications Number of channels: 9 (4 voltage, 5 current) Voltage (phases) Voltage (neutral) 100 mv - 600 V rms 1000 V peak 10 mv- 70 V rms 100 V peak External Current (1942 & 1949) Depends upon CT 14 bits 14 bits, 90 millivolts ± (1.5 % + 0.5 V) 14 bits, 90 millivolts ± (1.5 % + 0.5 V) ± (0.5 % + 0.1 % of probe range + probe accuracy) Internal Current (1941 & 1948) 20 A maximum 14 bits ± (1 % + 0.04 A) Nominal fundamental frequency 50/60 Hz ± 0.1 Hz Voltage and current sampling: 128 samples per cycle, phase-locked on 50 / 60 Hz Voltage and current sampling rate: 6.4 / 7.7 ks/s depending upon line frequency Voltage and current rms measurements: Processed for every full cycle Power measurements: W, VA, VAR, PF, dpf, THD, harmonics processed for very full cycle Waveform fault measurements (1941 & 1942) Sampling rate 6.4 / 7.7 ks/s depending upon line frequency Impulse voltage 100-1000 V peak 10 bits, 12 volts Impulse measurements (1948 & 1949) Sampling rate 2 MHz Impulse voltage 100-6400 V peak 10 bits, 12 volts Event memory: 6,000 simultaneous voltage and current events; Multi-session increases storage to 96,000 Communication: 10-base T Ethernet, RJ 45 connector, Optional TC/PIP Stack enables communication via Internet ± (5 % +36 V) over entire range ± (5 % +36 V) over entire range Electrical Operating voltages: 85-264 V AC, 47-440 Hz Power consumption: 40 watts Backup power: Rechargeable NiCad pack maintains operation after power loss for 5 minutes, allowing the monitor to record outage, reclosure attempts, and to resume monitoring upon restoration of power. Real time clock is backed up using a lithium battery with 10-year life. Mechanical Size: 12.39" x 11.56" x 6" (31.47 cm x 29.36 cm x 15.24 cm) Weight: 9 lbs. Operating temperature: 0-50 C (32-122 F), 90 % RH non-condensing Standards UL3111 IEC 868 Included accessories All units include user manual Warranty: 1 year 4 Reliable Power Meters Multipoint Power Recorder

Configuration Model Sampling Current Transformer Number System Type PQ Measurements Installable Options Power Consumption Impulse Waveform Multi-Session Software 1941 Standard 5-A fixed Included Included Included Option Option Option 1948 High-speed External clamp-on Included Included Included Included Option Option 1942 Standard 5-A fixed Included Included Included Option Option Option 1949 High-speed External clamp-on Included Included Included Included Option Option Harmonics TCP/IP Stack Accessories 1230 Metal Cabinet 5000/RPM 5100/RPM 5400/RPM 5500/RPM 5502/RPM Power Analysis Software with User Manual Professional Report Writer Software (requires 5000/RPM) Scenario Analysis Software Master Polling And Annunciation Software (requires 5000/RPM) Sub-Polling And Annunciation Software (requires 5000/RPM and 5500/RPM) Accessories for Multipoint models with external CT Option 3014R 3100R 3110/RPM 3112/RPM 3120R 3210/RPM 3212/RPM 3300R 3310/RPM 3312/RPM 40 Amp Clamp 1000 Amp Clamp 24-inch 100 Amp Flexi-Ct (tm) 48-inch 100 Amp Flexi-Ct 200 Amp Current Clamp 24-inch 1000 Amp Flexi-Ct 48-inch 1000 Amp Flexi-Ct 3000 Amp Clamp 24-inch 5000 Amp Flexi-Ct 48-inch 5000 Amp Flexi-Ct Fluke. Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries (425) 446-5500 or Fax (425) 446-5116 Web access: http://www.fluke.com 2005 Fluke Corporation. All rights reserved. Printed in U.S.A. 11/2005 2103797 D-EN-N Rev B