PD Diagnostic Applications and TechImp solutions

Similar documents
TECHIMP Technologies & Services for Diagnostics and Monitoring of High Voltage Assets

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

TECHIMP Power Transformer Monitoring

Doble Solutions for Partial Discharge. Greg Topjian Solutions Manager

Specialists in HV and MV test and diagnostics. Testing in Substations

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

THE POWER OF LIFE. WinTech Partial Discharge based Predictive Intelligence of insulation system to eliminate power failure risk.

PD Solutions. On-Line PD Measurement Devices

MONTRANO. Continuous monitoring system for power transformers

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets

Innovative Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers

Welcome to the Session on. HT Distribution Network

High-Voltage Test and

Partial Discharge Monitoring and Diagnosis of Power Generator

Onsite Mobile AC High Voltage Test System

A New Approach for Transformer Bushing Monitoring. Emilio Morales Technical Application Specialist Qualitrol

Why partial discharge testing makes good sense

Investigations on a Combined Resonance/VLF HV Test System Partial Discharge (PD) characteristics at VLF and DAC voltages

International Journal of Advance Engineering and Research Development. Comparison of Partial Discharge Detection Techniques of Transformer

EI HIGH VOLTAGE INSULATION TESTING POLICY

OFFLINE PD DIAGNOSTICS USING SEVERAL EXCITATION VOLTAGES

Diagnostic testing of cast resin transformers

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

SAMPLE. Determining the health of your power transformer begins with Transformer Clinic s SAMPLE testing programs.

VLF. DAC tandelta. Partial Discharge. Experience the world of Megger electrical testing

Hands-On Transformer Testing and Maintenance

PD Testing Considerations for MV Plant Cables

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

IRIS POWER TGA-B. Periodic Online Partial Discharge Monitoring Instrument for Turbine Generators and Motors

Electrical Equipment Condition Assessment

Effective maintenance test techniques for power transformers

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

CHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

USING DAMPED AC VOLTAGES

Extended analysis versus frequency of partial discharges phenomena, in support of quality assessment of insulating systems

Application Note. Detection of Partial Discharge Using Ultrasound. Detection of Partial Discharge Using Ultrasound. Problem. iriss.

OMICRON Seminar on Partial Discharge Diagnostics on HV Assets. January 30, 2018 Beirut, Lebanon

Case Studies of Electric Power Equipment Diagnostics Using Acoustic Emission

Effective Maintenance Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers

ECP HV INSULATION TESTING

MEDIUM & HIGH VOLTAGE

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

HV AC TESTING OF SUPER-LONG CABLES

Practical aspects of PD localization for long length Power Cables

PARTIAL DISCHARGE MEASUREMENT

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA FEATURES BENEFITS APPLICATIONS 1/6

CONTENTS. 1. Introduction Generating Stations 9 40

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

Revision of C Guide for Application of Monitoring Equipment to Liquid Immersed Transformers and Components. Mike Spurlock Chairman

Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor

Partial Discharge, Survey or Monitor?

PERMANENT ON-LINE MONITORING OF MV POWER CABLES BASED ON PARTIAL DISCHARGE DETECTION AND LOCALISATION AN UPDATE

Partial discharge diagnostics on very long and branched cable circuits

Life Prediction of Mold Transformer for Urban Rail

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

AC Resonant Test Systems Tank Type Up to 150 kv

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

Evaluation of Distribution Line Spacers Located Near the Coast

Cable testing and diagnostics

Aspects of PD interpretation in HV power cables. by Edward Gulski, Piotr Cichecki, Rogier Jongen

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables

WinTech Partial Discharge Testing and Monitoring Systems

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

Substation Preventive Maintenance

Transformer Shunt Fault Detection using Two Techniques

Testing and PD Diagnosis of MV Cable Systems with DAC Voltage Educational Session May St Pete Beach, Fl

Evaluation of Distribution Line Spacers through the Leakage Current Monitoring

Testing of 400 kv GIS

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

NETWORK INNOVATION COMPETITION ANGLE-DC PROJECT HOLISTIC CIRCUIT CONDITION MONITORING SYSTEM REPORT

II. TRADITIONAL APPROACH OF PD MEASUREMENTS

NEW MV CABLE ACCESSORY WITH EMBEDDED SENSOR TO CHECK PARTIAL DISCHARGE ACTIVITY

Autotransformer Condition Monitoring Systems

700 Series AC Dielectric Test Sets

ECP HV INSULATION TESTING

INVESTIGATION ON THE TECHNOLOGIES FOR DEFECT LOCALIZATION AND CHARACTERIZATION ON MEDIUM VOLTAGE UNDERGROUND LINES

PD ANALYSIS OF GAS INSULATED MEDIUM VOLTAGE SWITCHGEAR DURING FACTORY ASSEMBLY AND SITE COMMISSIONING

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

AC Resonant Test Systems Tank Type Up to 500 kv

ABB Power Products Service

Basics of Partial Discharge. Prepared for 2015 Phenix RSM Meeting January 2015

On-Site Partial Discharge Monitoring using the differential LEMKE PROBE LDP-5 and its accessories

PARTIAL DISCHARGE DETECTION - AN OVERVIEW

CONTINUOUS ON-LINE SYSTEM FOR PARTIAL DISCHARGE MONITORING FOR HA1 AT CHE ROBEŞTI

Chapter 7 Conclusion 7.1 General

A1-209 EXPERIENCES IN IDENTIFICATION OF PARTIAL DISCHARGE PATTERNS IN LARGE HYDROGENERATORS

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C

Partial Discharge (PD) techniques for measuring the condition of ageing HV/MV switchgear

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

High Voltage Diagnostics Sarl 4, Rue de Lac CH 1897 Le Bouveret Switzerland

EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS. C. Ceretta, R. Gobbo, G. Pesavento

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

ENLIGHTENING TECHNOLOGY. Advanced testing & monitoring solutions

NOVEL METHOD FOR ON-SITE TESTING AND DIAGNOSIS OF TRANSMISSION CABELS UP TO 250KV

User s Manual For CT Model IMB

VI 3 - i TABLE OF CONTENTS

Transcription:

PD Diagnostic Applications and TechImp solutions Condition Assessment Solutions for Electrical Systems. PD based innovative tools for the Condition Based Maintenance. MD-04.05.004 - rev. 00-29/08/2006

High Voltage Cable Systems PD highlights the presence of several types of on-going local degradation processes. - For Extruded Cables, the presence of PD within the cable system is to be avoided, in fact most of the internal activities within polymeric insulation systems lead to electrical treeing formation and, therefore, to failure. - Oil-filled Cables can better withstand PD activities, but several failures have been reported, particularly in accessories, which might have presented a great deal of partial discharge causing accelerated degradation processes. Noise rejection. In any case, for an effective diagnosis, it is vital to distinguish between PD internal to the cable system and external PD phenomena (disturbances or noise). Quality control PD tests in factory are nowadays a well assessed practice to make sure that the cable and/or accessory is not affected by manufacturing imperfections. After Laying tests & Condition Assessment tests After laying tests (voltage and PD tests carried out through e.g. a variable frequency mobile resonant test set) can be considered an effective quality control test of cable system installation. In fact, particularly for accessories, which are assembled on site, PD tests can highlight the presence of installation mistakes, as well as transportation or laying damages. The same type of test can be carried out again after some time to check for the possible inception of local degradation mechanisms. - Off-line tests are particularly effective because of the high performances in terms of measurement sensitivity, noise rejection capabilities, and possibility to test at voltage higher than the rated one and a single phase at a time. - On-line tests are feasible as well, provided that appropriate sensors are employed. These tests are particularly interesting since they can spotlight partial discharge behaviour at different loading (i.e. cable temperature) conditions. Source Location. Several techniques are associated with PD detection to derive information about the position of the possible partial discharge source, so that the defect can be localized and removed. Short length Cables. If the cable length is not too long, measurements from terminations can allow a complete picture of the cable conditions to be derived. On-line Monitoring Trending of PD phenomena during cable system life can be a very effective method to keep the degradation processes under observation and control, particularly if also quantities other than PD are monitored as well (e.g. temperature, current), so that correlation of PD possible inceptions with load and thermal cycling can be derived. 1

There are several ways to derive PD signals from a cable system, mainly: external inductive sensors, external capacitive sensors, built-in capacitive sensors (embedded capacitive taps).several methods have been devised in order to achieve PD measurements free of noise. Most of them are tailored for specific applications and fail in the presence of unusual disturbances. PDBase acquisition philosophy provides efficient noise rejection in most cases without adding any hardware filter or suppression device. As a matter of fact, noise signals have been observed to be very different from PD signals; therefore the classification system of PDBase succeeds in separating the contributions of PD and disturbances. In the following an example of noise rejection is reported. Motors & Generators PD assessment is an accepted practice to evaluate rotating machine conditions. The presence of PD in organic insulation systems calls for immediate maintenance actions. For inorganic insulation systems, instead, it is fundamental to distinguish among the different categories of PD. In fact, machines will have a different withstanding degree to different PD degradation mechanisms. In this case, therefore, the recognition of the type of PD source is vital to be able to support properly maintenance actions and planning. In any case, it is always fundamental to be able to get rid of all the signals relevant to noise and disturbances. When dealing with motors fed by PWM systems, PD detection is an issue than can be faced by appropriate noise rejection devices. Quality control PD tests in factory can be a very effective tool to test the quality of VPI impregnation processes, as well as of manufacturing processes of the single bars or coils (resin-rich technique). It is always a good practice to characterize the PD behaviour of a new machine in factory, also to be able to compare the results obtained on site after some time with this fundamental reference. Statistical databases can be developed aimed at checking production quality and typical flaws. Off-line and on-line PD tests - On-line PD monitoring or periodic assessment is commonly accepted as an effective method to check for the possible presence of localized degradation mechanisms and to evaluate their evolution with time. Correlation with the main operation parameters (e.g. load, voltage, ecc.) and with the response from other monitoring systems (e.g., ozone and vibration monitoring) can be exploited to improve diagnosis and to develop maintenance strategies. 2

- Off-line periodic assessments are often used for a deep machine analysis. This kind of test is generally more accurate than an on-line one, but it must be emphasized that the testing conditions may vary with respect to those of an on-line test. In fact, some degradation mechanisms can be active just while the machine is under the real operating conditions (mainly those related to vibration or load). When feasible, visual inspection can be carried out to reinforce diagnosis. Typically, the rotating machine is equipped with external capacitive couplers to derive PD and synchronization signals in order to enable on-line investigations. In alternative, High Frequency Current Transformers (HFCT) can be connected to the cable grounding leads or the grounding leads of the machine itself. Primary & Secondary Distribution Networks MV Switchgears PD activity in Medium Voltage Switchgears (both gas and air insulated), cables, transformers and other equipments which constitute a power distribution system can be originated at cable accessories, at bushings and post-insulators due to conductive pollution, at gas-insulated lines/switchgears due to, e.g., loose connections and SF6 leakages or floating metal particles, at cast resin transformers due to bad impregnation, at oil-filled transformers, etc.. Quality control PD tests in factory can be a very effective tool to test the quality of impregnation processes, as well as of manufacturing processes and can be mandatory for some of the sub-components (resin insulators, voltage and current transformers). Off-line and on-line PD tests - On-line PD monitoring or periodic assessment is commonly accepted as an effective method to check for the possible presence of localized degradation mechanisms and to evaluate their evolution with time and correlation with the other main operation parameters (e.g. load). For complete distribution systems, PD source identification and localization may require a comprehensive investigation (i.e., testing at different sites, using different sensors as, e.g., antennae and acoustic detectors, etc.) Typically, dividers used for voltage detection in switchgears can be used. In alternative, High Frequency Current Transformers (HFCT) can be connected to the cable grounding leads or other grounding connections, finally Capacitive Couplers can be installed in the switchgears to derive both PD and synchronization signals. Corona PD and PD on bushing creepage surfaces can be possibly detected and localized through acoustic sensors. 3

Power & Instrument Transformers Oil filled transformers are inherently affected by PD phenomena. For this equipment it is of primary importance to distinguish between discharges in oil and discharges affecting paper and pressboard. The latter, in fact, may lead to a fast degradation process and, possibly, breakdown. A combined use of DGA, humidity and temperature monitoring and PD analysis can lead to a thorough overview of transformer conditions. Cast Resin transformers should be free of PD, since the presence of PD can indicate bad impregnation and/or the existence of heavy degradation processes. Transformers are generally tested in factory for PD at the end of the manufacturing process. In the provision of checking transformer conditions during the asset life, the PD signature obtained at the beginning of the asset life might be considered necessary. Off-line and on-line PD tests - Off-line periodic assessments can be carried out to evaluate transformer behaviour in terms of PD. However, it is often difficult to provide a suitable mobile power source to carry out induced-voltage tests on large transformers. Moreover, the service interruption required to carry out an off-line investigation can be a problem for the asset manager. - On-line PD monitoring or on-line periodic assessment is becoming a better alternative to off-line tests. The combined use of different monitoring systems (e.g. PD, DGA, current, temperature etc...) allows a complete and reliable picture of the transformer conditions to be derived and observed over time. Typically, to perform measurements with adequate sensitivity, large power transformers are equipped with bushing taps from which both PD and synchronization signals can be derived. HFCT on grounding lead of cables connected to the transformers is an alternative. For single-phase measurement transformers inductive sensors wrapped around the grounding leads of the transformers, as well as capacitive couplers installed around the metallic support poles, can be used as PD sensors. 4

HV outdoor insulators for overhead lines procedure. PD can be a fundamental tool to assess the pollution condition of HV overhead insulators. Especially in salt-humid climates and polluted areas, insulators must be cleaned from time to time to avoid flashovers. Usually this operation is carried out at fixed time intervals and is very expensive. By monitoring the PD activity in the insulators it is possible to assess the pollution level of the insulators, and hence determine the right moment for washing, thus allowing the utility to plan a condition based maintenance On-line monitoring aimed at trending PD features related to insulator pollution can alert the asset manager about the need to carry out the cleaning activity. TechImp Solutions for PD Diagnosis Electrical system/apparatus HV Cable Systems Application Quality control On site (on/off-line) On-line monitoring TechImp Solution PDBase (with automatic GO/NO_GO tool) Distributed monitoring system based on PDScope set, which is installed on each joint/terminal bay. All PDScopes are connected together through an Ethernet systems which allows also a full remote control of the monitoring system PDBase (with automatic GO/NO_GO tool) Quality control Motors & Generators On site (on/off-line) On-line monitoring PDCheck or PDASD for machines fed by frequency drives Medium Voltage Quality control PDBase (with automatic GO/NO_GO tool) Switchgears (GIS, On site (on/off-line) AIS) Distribution networks On-line monitoring PDscope based monitoring systems Quality control PDBase (with automatic GO/NO_GO tool) High Voltage Switchgears On site (on/off-line) (GIS) On-line monitoring PDpeak or PDcheck Quality control PDBase (with automatic GO/NO_GO tool) Power & Instrument On site (on/off-line) Transformers On-line monitoring PDCheck (possibly integrated with DGA tool) Overhead Insulators On-line monitoring Stand-alone set based on the PDCheck with solar cell for pollution and GSM communication facilities for remote control assessment 5