CCITT G.703 Baluns HC-GB- MB8S. Shielded RJ45 Jack to Male BNC Connector. STANDARD TYPE Ordering Information

Similar documents
Introduction. 75 /120 OHM IDC Balun. 75 /120 Ohm IDC Mini Balun. 75 /120 Ohm Wire Wrap Balun. 75 /120 Ohm BNC to RJ45 Balun. 75 /120 Ohm Balun Panel

CATALOG. Network Access & Connectivity

G.703 Balun Module Panel Unit G.703 Balun Module G.703 Balun Chassis

Since its inception, AC&E has specialised in the development and manufacture of products such as:

Balun Ohm to 120 Ohm Balin - IDC Type Balun - Balun Panels - Balun Pigtail

baluns Balun solutions TX RX defining excellence in global network solutions

MONITOR BRACKETS CCTV SYSTEMS. BT7510S Ex GST Inc GST. BT7511S Ex GST Inc GST. BT7512S Ex GST Inc GST. BT7518S Ex GST Inc GST. BT7513S Ex GST Inc GST

120 Ohms Digital Distribution Frame Solution

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

Data sheet C6 A modul K 90 jack - keystone style

SECTION 14. DIN 1.0/2.3 / DIN 1.6/5.6 / Type 43 R118 / R120 / R129 / R214

STANDARD COAXIAL CONNECTORS. Eco 7/16 series

Data sheet C6 A RJ45 field plug pro 360

Data sheet C6 A RJ45 field plug pro

Data sheet E-DAT Industry RJ45 plug black Cat.6 Class E A

Data sheet C6 A modul K 180 jack - Keystone style

AESA TECHNOLOGY OF LAN CABLE

Data sheet C5 RJ45 field plug pro 2P PROFINET

Data sheet. M12 Jack X-coded IP67, field assembly. Illustrations P/N MMF881A315 EAN Product specification. Page 1/

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568B. Illustrations P/N I-B1 EAN Product specification. Page 1/

242, , FAX.

SMB Connectors. Adaptors-50Ω. Plug to Plug. Jack to Jack. Plug to Jack. Bulkhead Jack to Jack

Data sheet. C5 RJ45 field plug pro 2P 360 PROFINET. Illustrations P/N 130E405042PE EAN Product specification. Page 1/

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN

Data sheet C6 A RJ45 field plug pro 360

Connectors for Telecommunications

Amphenol RF Interconnects BNC 31 Series Bayonet Lock RF Connector System

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21

Data sheet C6 A RJ45 field plug pro 360

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02


Setting Standards Connectors M 16

Amphenol RF. MMCX Micro-Mate (MMCX) Connectors MMCX. Description. Features/Benefits. Applications

Data sheet E-DAT modul 2 port AP Cat.6 A, pearl white

OPENETICS. P/N E-DAT Industry RJ45 field plug insert Cat.6A. Specialist Manufacturer Voice Data Security.

Physical Test Setup for Impulse Noise Testing

Data sheet E-DAT Industry RJ45 field plug insert Cat.6 Class E A

Amphenol RF. Mini-BNC Mini-BNC Connectors. Mini-BNC. Description. Features/Benefits. Applications

Broadband performance with low reflection DC to 4 GHz provides low cost connector combined with high quality.

10. Mini Coax Connectors

TNC SERIES General... 4 Interface... 5 Characteristics...6-7

MCX. Aliner Industries, Inc. No. 32, Lane 387, Min-an Rd., Sinjhuang City, Taipei County 24256, Taiwan

Installation Instructions

Data sheet. E-DAT modul 3 port AP Cat.6A, pure white. Illustrations P/N E EAN Product specification. Page 1/

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

Amphenol RF UHF. UHF Connector Series UHF. Description. Features/Benefits. Applications

ST-CCTV-VBAC16 16-Channel Active UTP Video Receiver

Data sheet Patch cord Cat.6 A AWG m yellow

Quick Reference Guide RF Coaxial Connectors

BL-ER-P Ethernet Radio Unit for Pedestal Installation Guide

both pin and sleeve contacts.

1/4" and 3.5 mm Phone Plugs

Corning Gilbert Inc. Microwave Push-on Interconnects 1

USER MANUAL HIGH INTERCEPT LOW NOISE AMPLIFIER (HILNA TM ) MODEL NUMBER: HILNA LS

From dc to 10 GHz the. VSWR shall not exceed 1.3 &.04 (f) where f is the frequency in Gigahertz (GHz).

A short, off-center fed dipole for 40 m and 20 m by Daniel Marks, KW4TI

Electrical Components Catalog RF Connectors

SRICOM SRINAR COMMUNICATIONS PVT. LTD.

Coupling/Decoupling Networks (CDN)

Preparation and Installation Tools and Accessories

ST-CCTV-VBAC8 8-Channel Active UTP Video Receiver

MULTI CONNECTION SYSTEM. Product Overview

Data sheet. M12 field plug X-coded, straight. Illustrations P/N MNF881A EAN Product specification. Page 1/

Amphenol RF MCX. MCX Connectors MCX. Description. Features/Benefits. Applications

711 Series Single Way DB-1a

Video Mono Audio Baluns

ADS. Antenna-Disconnect-Switch. To protect your radio equipment from damage due to surge voltages. Assembly and Operation Manual

NEER Zinc Cable and Conduit Connectors For Flexible Metal Conduit

SPACEWIRE CABLE AND CONNECTOR VARIATIONS

Amphenol RF- BNC Connector Series

10. Mini Coax Connectors

GPPO Interconnect Series Product Information

SECTION 7 R114 / R115 / R116 / R117 / R112

Data sheet Cable connector class F A


Antennas and Wireless Accessories

Network Cables 12. Flat Ribbon Cables 13. Coaxial Cables 14. Test Cables 15. Video Interconnect Cables 16. D-Sub Cables 17

FOR POWER AND DATA HEAVY DUTY CONNECTOR SYSTEM

Introduction to Copper Products Copper Cable Assemblies

Ø1,37 (.054) MIN Ø2,67 (.105) MAX Ø1,35 (.053) MAX Ø4,83 (.190) MAX 1,78 (.070) MAX 0,84 (.033) SEE NOTE # 2 1,91 (.075) MIN MIN CLOSED ENTRY CONTACT

Series IV Pro-Connect Baluns. Set-Up Guide

WiFi Interface Identifier

SMA - 50 Ohm Connectors

Content. - DDF Frame Pair Screen Cable Pair Screen Cable

SMB Connectors. RF Coax Connectors. Product Facts

Workstation Outlets GigaFlex PS6+ Modules Category 6

High Density DDF Solution

UHV Double-Ended SMA Feedthrough, , Conflat compatible flange

Sixteen Port PoE+ Receiver Hub Model NV-ER1816i

WireMaster Coax BNC PN: Rev C 2/13

Video Stereo Audio Baluns

Series 791 Connectors

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

Coaxial Attenuators Low, medium and high power

2mm metric system INTRODUCTION MAIN FEATURES

Telegärtner Product Overview. Coaxial Connectors Networking Components

Chord Crimson VEE 3. Chord Cobra VEE 3. Chord Chameleon VEE 3. Chord Cadenza Reference. Chord Chorus Reference. Chord Anthem Reference

This attractive raceway conceals and

Digital Audio Coax Baluns Series. (Front View) (Back View)

Transcription:

CCITT G.703 Baluns REGULAR TYPE The standard single baluns come with a variety of coaxial interfaces and a RJ45 twisted pair connection. MB8S Shielded RJ45 Jack to Male BNC STANDARD TYPE M5D8S Shielded RJ45 Jack to Male 1.6/5.6 DIN KEYSTONE TYPE This baluns are designed to easily snap in and out of the wall plate, patch panel and surface box modular configurations. FBK8 Unshielded RJ45 Keystone Jack to Female BNC DUAL TYPE The dual balun provide transformation of 75Ω coaxial TX/RX Pair to two 120Ω twisted pair output on a single RJ45 jack. - No AC power or batteries needed. - Link-to-data isolation: Mini. 250v. - Bi-directional signal conversion. - Operating temperature: 0 C~75 C. - Ultra-miniature enclosure. - Transmission distance: 180m via Cat.5e cable. 2FB8S Shielded RJ45 Jack to 2 x Female BNC 2F5D8S Shielded RJ45 Jack to 2 x Female 1.6/5.6 DIN DUAL FLY-LEAD TYPE 2MB8S-C Shielded RJ45 Jack to 2 x Male BNC 6" Cord.

LSA+ IDC TYPE Intended for panel mounting and can be supplied with a variety of coaxial connectors BNC, BT Type 43, 1.0/2.3, 1.6/5.6 DIN. Twisted Pair termination via 3-pole LSA+ IDC. - The mechanical endurance of the coaxial connectors are designed to provide in excess of 500 connect- - reconnect cycles. - On the balanced end, the 120Ω interface connector is designed to accept termination of single strand - conductors with nominal diameter up to 0.50mm. - The force required to terminate the IDC is designed to remain fully operative and intact after 200 - connect/reconnect cycles for LSA+ IDC Terminals. - Simple cable anchorage method integral with the balun is achieved by inserting the cable through the hollow - section under the terminal markings. MBK LSA+ IDC to Male BNC FBK LSA+ IDC to Female BNC Bulkhead W/Metal Thread. FBPK LSA+ IDC to Female BNC Bulkhead W/Plastic Isolated Thread. LSA+ IDC to Female BNC FBFK Flange Mount W/4-Hole. MTK LSA+ IDC to Male BT Type 43 Bulkhead MTFK LSA+ IDC to Male BT Type 43 Float Mount FTK LSA+ IDC to Female BT Type 43 M2DK LSA+ IDC to Male 1.0/2.3 DIN F2DK LSA+ IDC to Female 1.0/2.3 DIN

M5DK LSA+ IDC to Male 1.6/5.6 DIN F5DK LSA+ IDC to Female 1.6/5.6 DIN TOOLLESS IDC TYPE It is designed to terminate wires by hand, without punchdown tool for faster and easier installation. - Insertion loss, maximum of 0.2dB at 2Mbps and 0.3dB at 8Mbps max. - Link to data isolation, minimum 250v AC/DC min. - Transmission distance: 180m via Cat.5e cable. - Return loss, -29dB at 2Mbps and -21dB at 8Mbps. <back> MBT Toolless IDC to Male BNC FBT BNC Bulkhead W/Metal Thread. BNC Bulkhead FBPT W/Plastic Isolated Thread. FBFT BNC Flange Mount W/4-Hole. MTT Toolless IDC to Male BT Type 43 Bulkhead MTFT Toolless IDC to Male BT Type 43 Float Mount FTT BT Type 43

M2DT Toolless IDC to Male 1.0/2.3 DIN F2DT 1.0/2.3 DIN M5DT Toolless IDC to Male 1.6/5.6 DIN F5DT 1.6/5.6 DIN SCREW-IN IDC TYPE These baluns are fully shielded products which are ideal in applications where size and space are restricted due to small dimension. They are intended for panel or cable mounting and feature IDC termination allowing installation without special tools. Designed to match differential inputs and outputs or modern chipsets. - Contact: plated mini. 1.25µ Ni & mini. 1.25µ Au - IDC connect /disconnect cycle 20. - IDC suitable for 23~26 AWG cooper cable, Teflon insulators. - Body parts plated mini. 5µ Ni. - Coaxial connector insertion 500 cycle. - Cable anchorage is via a tortuous path around the stuffer cap and grounding ring. - IDC: phosphor bronze. MBI Screw-In IDC to Male BNC FBI BNC Bulkhead W/Metal Thread. BNC Bulkhead FBPI W/Plastic Isolated Thread. FBFI BNC Flange Mount W/4-Hole. MTI Screw-In IDC to Male BT Type 43 Bulkhead

Screw-In IDC to Male BT MTFI Type 43 Float Mount MTHI Screw-In IDC to Male BT Type 43 HDC Float Mount FTI BT Type 43 M2DI Screw-In IDC to Male 1.0/2.3 DIN F2DI 1.0/2.3 DIN M5DI Screw-In IDC to Male 1.6/5.6 DIN F5DI 1.6/5.6 DIN PATCH PANELS The CCITT G.703 balun panels match multiple sets of dual 75Ω coax connections to multiple 120Ω twisted-pair connections. Supporting data stream to three speed versions, 2-8 Mbps for E1/T1 and E2/T2, 2-8-34Mbps for E1/T1 to E3, 34 to 155Mbps for E3 and higher, the patch panel bi-directionally match, not only signal impedance, but also the pulse shapes of the signals according to the CCITT G.703 standard. The modular construction allows up to 16-port of G.703 balun modules in a 19" rack mount chassis. The module provides a cost-effective solution and can be purchased separately. AC power or batteries needed - Link-to-data isolation: Mini. 250V - Bi-directional signal conversion - Operating temperature: 0 C~75 C - Typical distance: 180m via Cat.5e cable - No

-HC-GP16-8FB-1U 16-Port G.703 Patch Panel, Female BNC To STP RJ45 On The Back Side. HC-GP16-8FB-2U 16-Port G.703 Patch Panel, Female BNC To STP RJ45 On The Same Side. HC-GPM01 HC-GPM02 1-Port G.703 Balun Module, Female BNC To STP RJ45 On The Back Side. 1-Port G.703 Balun Module, Female BNC To STP RJ45 On The Same Side.