Lab Equipment EECS 311 Fall 2009

Similar documents
UNIVERSITY OF NORTH CAROLINA AT CHARLOTTE Department of Electrical and Computer Engineering

AME140 Lab #2 INTRODUCTION TO ELECTRONIC TEST EQUIPMENT AND BASIC ELECTRONICS MEASUREMENTS

LAB 1: Familiarity with Laboratory Equipment (_/10)

UNIVERSITY OF CALIFORNIA, DAVIS Department of Electrical and Computer Engineering. EEC 180A DIGITAL SYSTEMS I Winter 2015

LAB I. INTRODUCTION TO LAB EQUIPMENT

Laboratory Equipment Instruction Manual 2011

Bring your textbook to lab.

University of Michigan EECS 311: Electronic Circuits Fall 2008 LAB 4 SINGLE STAGE AMPLIFIER

Group: Names: Resistor Band Colors Measured Value ( ) R 1 : 1k R 2 : 1k R 3 : 2k R 4 : 1M R 5 : 1M

CHAPTER 6. Motor Driver

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

ECE 2274 Lab 1 (Intro)

Chapter 1: DC circuit basics

Electric Circuit II Lab Manual Session #1

Physics 323. Experiment # 1 - Oscilloscope and Breadboard

Lab 2: Linear and Nonlinear Circuit Elements and Networks

EE 368 Electronics Lab. Experiment 10 Operational Amplifier Applications (2)

Precalculations Individual Portion Introductory Lab: Basic Operation of Common Laboratory Instruments

ECE 53A: Fundamentals of Electrical Engineering I

Experiment 1: Instrument Familiarization (8/28/06)

Chapter 9: Operational Amplifiers

Prepare for this experiment!

University of Michigan EECS 311: Electronic Circuits Fall 2009 LAB 2 NON IDEAL OPAMPS

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

Experiment 1: Instrument Familiarization

EGR Laboratory 3 - Operational Amplifiers (Op Amps)

Equipment: You will use the bench power supply, function generator and oscilloscope.

Physics 120 Lab 6 (2018) - Field Effect Transistors: Ohmic Region

DC Circuits, Ohm's Law and Multimeters Physics 246

ME 365 EXPERIMENT 7 SIGNAL CONDITIONING AND LOADING

Name: Resistors and Basic Resistive Circuits. Objective: To gain experience with data acquisition proto-boards physical resistors. Table of Contents:

University of Jordan School of Engineering Electrical Engineering Department. EE 204 Electrical Engineering Lab

Practical 2P12 Semiconductor Devices

Experiment A8 Electronics III Procedure

DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMBRIDGE, MASSACHUSETTS 02139

OPERATIONAL AMPLIFIERS (OP-AMPS) II

MASSACHUSETTS INSTITUTE OF TECHNOLOGY

Physics 310 Lab 2 Circuit Transients and Oscilloscopes

ECE 4670 Spring 2014 Lab 1 Linear System Characteristics

10: AMPLIFIERS. Circuit Connections in the Laboratory. Op-Amp. I. Introduction

A Manual explaining the basic Components, Devices and Experimental Methods employed in an Electronic Instrumentation Lab for Scientists. MULTIMETER.

EECE 2413 Electronics Laboratory

Physics 120 Lab 1 (2018) - Instruments and DC Circuits

Introduction to basic laboratory instruments

EK307 Introduction to the Lab

Practical 2P12 Semiconductor Devices

DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMBRIDGE, MASSACHUSETTS 02139

Laboratory 2 (drawn from lab text by Alciatore)

Notes on Experiment #1

Laboratory 4: Amplification, Impedance, and Frequency Response

LAB II. INTRODUCTION TO LAB EQUIPMENT

Experiment 3 Ohm s Law

BME 3512 Bioelectronics Laboratory Five - Operational Amplifiers

Combinational logic: Breadboard adders

LAB I. INTRODUCTION TO LAB EQUIPMENT

Penrose Quantizer Assembly Guide

Lab #1 Lab Introduction

Chapter 1: DC circuit basics

Electronics. RC Filter, DC Supply, and 555

Experiment A8 Electronics III Procedure

ECE 201 LAB 8 TRANSFORMERS & SINUSOIDAL STEADY STATE ANALYSIS

BME/ISE 3512 Bioelectronics. Laboratory Five - Operational Amplifiers

Experiment 8 Frequency Response

UNIVERSITY OF UTAH ELECTRICAL ENGINEERING DEPARTMENT

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

Laboratory 2. Lab 2. Instrument Familiarization and Basic Electrical Relations. Required Components: 2 1k resistors 2 1M resistors 1 2k resistor

Design and Technology

EXAMPLE. Use this jack for the red test lead when measuring. current from 0 to 200mA. Figure P-1

ECE 2274 Lab 2. Your calculator will have a setting that will automatically generate the correct format.

EET140/3 ELECTRIC CIRCUIT I

CPE 100L DIGITAL LOGIC DESIGN I DESIGN LABORATORY LABORATORY 1 LAB SAFETY QUIZ & LAB EQUIPMENT USE TUTORIAL UNIVERSITY OF NEVADA, LAS VEGAS GOALS:

ECE 2274 Lab 2 (Network Theorems)

On-Line Students Analog Discovery 2: Arbitrary Waveform Generator (AWG). Two channel oscilloscope

On-Line Students Analog Discovery 2: Arbitrary Waveform Generator (AWG). Two channel oscilloscope

EGR Laboratory 9 - Operational Amplifiers (Op Amps) Team Names

electrical noise and interference, environmental changes, instrument resolution, or uncertainties in the measurement process itself.

Instrument Usage in Circuits Lab

EK307 Passive Filters and Steady State Frequency Response

University of Portland EE 271 Electrical Circuits Laboratory. Experiment: Op Amps

ECE ECE285. Electric Circuit Analysis I. Spring Nathalia Peixoto. Rev.2.0: Rev Electric Circuits I

ET 304A Laboratory Tutorial-Circuitmaker For Transient and Frequency Analysis

Breadboard Primer. Experience. Objective. No previous electronics experience is required.

Pre-Laboratory Assignment

ELR 4202C Project: Finger Pulse Display Module

Intro To Engineering II for ECE: Lab 7 The Op Amp Erin Webster and Dr. Jay Weitzen, c 2014 All rights reserved.

ECE 480: SENIOR DESIGN LABORATORY

1-1. Kirchoff s Laws A. Construct the circuit shown below. R 1 =1 kω. = 2.7 kω R 3 R 2 5 V

EXPERIMENT 1 PRELIMINARY MATERIAL

APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS

University of Utah Electrical Engineering Department ECE 2100 Experiment No. 2 Linear Operational Amplifier Circuits II

University of Pennsylvania Department of Electrical and Systems Engineering. ESE 206: Electrical Circuits and Systems II - Lab

Sept 13 Pre-lab due Sept 12; Lab memo due Sept 19 at the START of lab time, 1:10pm

Lab 11: 555 Timer/Oscillator Circuits

Lab 9: Operational amplifiers II (version 1.5)

DEPARTMENT OF ELECTRONIC ENGINEERING ELECTRONIC WORKSHOP # 03. Resistors

AC/DC ELECTRONICS LABORATORY

Lab 1: Basic Lab Equipment and Measurements

Test No. 1. Introduction to Scope Measurements. Report History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 1

POLYTECHNIC UNIVERSITY Electrical Engineering Department. EE SOPHOMORE LABORATORY Experiment 3 The Oscilloscope

Experiment 2. Ohm s Law. Become familiar with the use of a digital voltmeter and a digital ammeter to measure DC voltage and current.

Transcription:

Lab Equipment EECS 311 Fall 2009 Contents Lab Equipment Overview pg. 1 Lab Components.. pg. 4 Probe Compensation... pg. 8 Finite Instrumentation Impedance. pg.10 Simulation Tools..... pg. 10 1 - Laboratory Equipment 1.1 Proto-boards A proto-board provides a fast way of hooking up circuits with no soldering. The protoboard consists of an array of interconnected holes. Connections are made by pushing leads into the holes. When using a proto-board, only straight wires of small diameter (a resistor lead or smaller) should be inserted into the holes. In general, when building a proto-board circuit, a good rule is "the fewer the wires, the better." A messy circuit is likely to perform poorly and be a pain to debug. Some of the labs (the design labs in particular) may require more than one testing session to complete. For these labs, it is advantageous to be able to keep your circuits constructed between testing sessions. For this purpose, you may check out a proto-board from your lab GSI. Note that this proto-board must be returned prior to the final. If it is not returned before the final, you will receive a grade of "incomplete" for the course.

Page 2 of 10 1.2 Oscilloscopes General An oscilloscope is the most useful piece of test equipment in the laboratory. Basically, it is a device which graphically displays time-varying voltage signals. In particular, it is most often used to display voltages as a function of time. Each of the stations in the EECS 311 laboratory is equipped with an oscilloscope. You should already be familiar with the use of oscilloscopes from previous required courses (e.g., EECS 215). To best familiarize yourself with the oscilloscope used in the EECS 311 laboratory, browse through the "User's Guide" located in the lab. Some Helpful Pointers. The following usage pointers are helpful in insuring the most accurate circuit measurements in the EECS 311 laboratory: (i) Use an oscilloscope probe whenever possible. The probe may or may not have a built in attenuator, and the oscilloscope has a setting that will scale the measured voltage accordingly. This feature is under Utilities. (ii) Make sure each probe is grounded. (iii) Compensate the oscilloscope probe frequently (see page 8). (iv) Always know the location of the ground reference located on the display. (v) Use an external trigger whenever possible. 1.3 Digital Multimeters (DMM's) Voltage Measurements. A DMM can be used to make measurements of both AC and DC voltages. The measurement procedure involves setting the DMM to the appropriate scale, selecting AC or DC volts, and connecting the probe between the two points to be measured. If set to the wrong scale, the display will usually flash or give some other error indication. Some points to keep in mind: (i) The EECS 311 DMM's will usually not load the circuit excessively, because they have an input impedance of several MΩ's. (ii) Voltage measurements are made in parallel. (iii) When reading AC volts, most meters will read true RMS only if the AC voltage is a sine wave. Some DMM's, usually marked "True RMS", will read the RMS voltage of arbitrary waveforms. (iv) When reading AC volts, the DMM has a fairly low upper frequency limit, usually a couple of khz or less. Consult the instruction manual for further details.

Page 3 of 10 Resistance Measurements To measure resistance, set the DMM to ohms and select the appropriate scale. Connect the probes across the resistance to be measured. Some fine points: (i) When taking data using the high resistance scale, make sure not to handle the probe tips. Handling will add your skin resistance in parallel with the resistance to be measured, which will cause the DMM to read a value lower than the actual resistance. (ii) Only certain scales will supply enough current to forward bias a diode. These are marked with a diode symbol. (iii) Resistance measurements should be made outside of the circuit whenever possible. Any in-circuit measurements made should be considered suspect. Current Measurements When measuring current, it is necessary to set the DMM to ma and to select the appropriate scale. Note that the probes are connected to a different set of jacks for current measurements. One must always remember to make current measurements in SERIES, not parallel. Connecting the meter across a voltage is likely to blow a fuse in the meter. Both AC and DC current can be measured. The same limitations as those on AC voltage measurements apply here. 1.4 Function Generators Function generators are so named because they produce various voltage waveforms. The most common are square, sine, and triangle. The function generators in the EECS 311 lab have various triggering and gating functions. To adjust the peak-to-peak voltage of the output signal, AMPLITUDE controls are provided. The DC level of the signal can also be adjusted with the OFFSET control. To adjust the frequency, use the FREQUENCY button. There are three ways to adjust the output of the function generator. First, press the button of the parameter you would like to change. To change the value (ie frequency, amplitude, or offset) either: (ii) Turn the knob value. clockwise to increase the value or counterclockwise to decrease the (ii) Use the arrow buttons on the function generator: ( ) up arrow = increase value ( ) down arrow = decease value ( ) left and right arrows, select digit to change

Page 4 of 10 (iii) Enter the desired value directly using the Enter Number button. To do this, press Enter Number. Then enter the value you want using the numeric keypad. When you are done, press Enter. Of particular interest is the external triggering output. Whenever possible, this signal should be directly connected to the external triggering input of the oscilloscope. 1.5 Capacitance Meters In EECS 311, we will only be concerned with simple capacitance meters. To use a capacitance meter: (i) Depress the measurement button without anything connected and use the OFFSET or ZERO control to zero the display. (ii) Insert the device to be tested into the slots on the front of the capacitance meter. Keep any leads as short as possible. (iii) Depress the measurement button. 1.6 Electronic Components Resistors The resistors used in the EECS 311 lab are all 5%, 1/4 Watt carbon film resistors. "5%" refers to the resistance tolerance at room temperature (i.e., how far off from the stated value it may be), "1/4 Watt" refers to the maximum safe power dissipation, and "carbon film" refers to the resistor construction. The resistance value is indicated by color coded bands. Learning to read the color code will save you both grief and time in the lab (since you will not have to use the DMM to measure every time you need to know an approximate resistor value). The colors represent digits as indicated in Table I.

Page 5 of 10 The actual value of the bands depends on their relative position. The right most band indicates tolerance. To read the color code, hold the resistor so the gold or silver tolerance band is on the right. (20% resistors do not have a gold or silver tolerance color band, however, they have a space where the band would be). Now, reading from left to right, the first two color bands are read directly as numerals. The third band (sometimes called the multiplier band) indicates the number of zeros to be concatenated on the first two digits. For example, if you read BROWN-GREEN-ORANGE-GOLD, the resistor would be of 5% tolerance and would have the value 15000, or 15 kω. In other words, "1", "5", and 3 zeros (for orange) following. BROWN-BLACK-YELLOW-SILVER would be a 10% 100000, or 100 kω resistor. In other words, "1", "0", and 4 zeros (for yellow) following. Capacitors The marking for capacitors is not nearly as standardized as that for resistors. The most -12 common method is to mark the capacitor in picofarads (pf = 10 Farads) using the same format as resistors, but with numerals instead of colors. For example, 101 indicates 100 pf ("1", "0", and 1 zero following), 100 would be 10 pf. Ask your GSI for help in identifying capacitors. We will use two basic types of capacitors in the EECS 311 lab: ceramic and electrolytic. Ceramic caps are relatively temperature stable and have the advantage of being nonpolarized; that is, they can be charged to either polarity. Electrolytic capacitors, on the other hand, can only be subjected to a specific DC voltage polarity. The polarity is marked on the

Page 6 of 10 outside of the capacitor. DO NOT hook up an electrolytic capacitor backwards, as this will almost certainly damage the capacitor. (It could possibly explode.) Electrolytic capacitors have the advantage of possessing a high capacitance per unit volume; i.e., the largest valued capacitors will often be electrolytic. Semiconductor Diodes and Transistors. The diodes used in the EECS 311 lab are general purpose signal diodes and are marked as shown in Fig. 1. Transistors do not have standard markings or pinouts. Ask your GSI for help in identifying transistor pinouts.

Page 7 of 10 Integrated Circuits. The only integrated circuit used in the EECS 311 lab is the 741 op amp. Different manufacturers make 741's with different prefixes. To name a few, ua741 indicates that the chip was manufactured by Fairchild Semiconductor, NE741 indicates Signetics, and LM741 indicates National Semiconductor. Despite different manufacturers, all of these chips are functionally identical. The 741 comes in an 8- or 14-pin DIP (Dual In-line Package). The pinout for a 741 is given in Fig. 2. The pin numbers in any DIP package can be determined by first looking down on the IC such that the notch or dot is facing left. Pin 1 is now in the lower left hand corner. The pin numbers increase as you count counterclockwise around the IC starting at pin 1. This is illustrated in the example sketches of the 741 in Fig. 2. More information on the actual 741 op amps to be used in the lab, as well as all of the other electronic components used, can be found in the data sheets presented in Appendix A. Make sure you consult the data sheet whenever you are unsure of the pinout for a particular device.

Page 8 of 10 2 Probe Compensation Whenever measurements of a physical system are made, the act of measurement alters the system of interest, thus, altering the value of the desired parameter. For the case of the laboratory measurements to be made in EECS 311, all of the measurement equipment exhibits finite input/output impedance, which can load the circuits being measured, changing their properties and altering the actual values being measured. Resistive loading of amplifiers is a topic for EECS 311 lecture. As will be seen in this lab, capacitors can also significantly load circuits (as can inductors). As an example of loading by measurement, consider the use of an oscilloscope to measure the output of a low-pass filter consisting of R 1 and C 1. The required experimental setup for this measurement is depicted in Fig. PL1.2(a) below. Figure PL1.1 Figure PL1.2 Figure PL1.2(b) is an equivalent circuit schematic for the experimental set-up of Fig. PL1.2(a). The combined capacitance of the oscilloscope and the coaxial cable is represented by C2 = 50 pf, and the input resistance of the oscilloscope is modeled by Rosc = 1 MΩ.

Page 9 of 10 To minimize the effects of loading, oscilloscope probes are often built as compensated attenuators. The equivalent circuit schematic for a typical compensated attenuator is shown in Fig. PL1.3. Note that V i in Fig. PL1.3 is not the V i in Fig. PL1.1 and Fig. PL1.2. The voltage Vi in Fig. PL1.3 is the voltage across C 1 in Fig. PL1.1 and Fig. PL1.2. To Test Circuit (a) Derive an expression for the rise time of the compensated attenuator for the case when Ccomp = 0. (b) Derive an expression for Ccomp based on the values of Rbuff, R osc, and C 2 to yield the following transfer function: Note that due to the addition of Ccomp, the rise time of the circuit can theoretically be made zero. Compensating the Oscilloscope Probe The first step in any lab is to organize the required equipment and to COMPENSATE THE OSCILLOSCOPE PROBE. The probe can be easily compensated in the following way: (i) Connect the probe to the test point located on the front of the HP oscilloscope. The test point provides a square wave of known properties. The scope must be DC coupled for this operation. (ii) Set the triggering to normal and adjust the trigger level for a stable display. (iii) Adjust the sweep time and vertical sensitivity to display about two cycles of the square wave. (iv) With an adjustment tool, gently adjust the compensation control on the probe while observing the image displayed on the screen. Continue to adjust the probe until the square wave has "as flat a top as possible", as indicated in the far right of Fig. L1.1.

Page 10 of 10 3 - Finite Instrumentation Impedance Depending on the user defined load impedance, the function generator will scale the output voltage it generates to achieve the desired Vout. For instance, if the load is defined to be 50 ohms and the generator is set to output 1V, then it will in reality output 2V assuming that Rgen is also 50 ohms. However, if the load is defined to be in high-z, then Vgen will only be 1V. 4 - Simulation Tools As mentioned in lecture, EECS 311 will utilize the Cadence software package for schematic entry and simulation of circuits. Virtuoso is the package for circuit schematic entry, while Spectre is the package for circuit simulation. Feel free to ask your GSI for help in using the Cadence tools. Within this Laboratory Manual there are many references to the word SPICE. SPICE is the first extensive circuit simulator created in the 70's. Today, virtually all circuit simulator programs, including Spectre, use SPICE within their kernels. Thus, the device models used by Spectre and other circuit simulation tools are basically SPICE models, as they conform to the strict SPICE format. You will be provided with a tutorial covering basic use of the Cadence software.