Transmission of Electrical Energy

Similar documents
PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.

EE 340 Transmission Lines. Spring 2012

EE 340 Transmission Lines

EE 741. Primary & Secondary Distribution Systems

Utility System Lightning Protection

2000 Mathematics Subject Classification: 68Uxx/Subject Classification for Computer Science. 281, 242.2

Tab 8 Surge Arresters

Modeling insulation in high-voltage substations

Case Study 1. Power System Planning and Design: Power Plant, Transmission Lines, and Substations

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

Investigation of Transmission Line Overvoltages and their Deduction Approach

Analysis of lightning performance of 132KV transmission line by application of surge arresters

Lightning overvoltage and protection of power substations

Session Four: Practical Insulation Co-ordination for Lightning Induced Overvoltages

Tab 2 Voltage Stresses Switching Transients

Roll No. :... Invigilator s Signature :.. CS/B.TECH(EE)/SEM-5/EE-502/ POWER SYSTEM-I. Time Allotted : 3 Hours Full Marks : 70

Fatima Michael college of Engineering and Technology

Insulation Co-ordination For HVDC Station

MODIFICATION OF THE ARRESTER ARRANGEMENT WHEN CONVERTING THE METHOD OF NEUTRAL TREATMENT

Computer Based Model for Design Selection of Lightning Arrester for 132/33kV Substation

University of Zagreb Faculty of Electrical Engineering and Computing

High voltage engineering

ROEVER ENGINEERING COLLEGE ELAMBALUR, PERAMBALUR DEPARTMENT OF ELECTRICAL & ELECTRONICS ENGINEERING

EL 403 MODEL TEST PAPER - 1 POWER SYSTEMS. Time: Three Hours Maximum Marks: 100

When surge arres t ers are installed close to a power transformer, overvoltage TRANSFORMER IN GRID ABSTRACT KEYWORDS

IMP/007/011 - Code of Practice for the Application of Lightning Protection

ABSTRACTS of SESSION 6

EE 740 Transmission Lines

ELEC Transmission i and

A Case Study on Selection and Application of Lightning Arrester and Designing its Suitable Grounding Grid

CUSTOM DESIGN COAXIAL CABLES BY SICAB

Comparison between Different InstallationLocations of Surge Arresters at Transmission Line Using EMTP-RV

The Lightning Event. White Paper

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS

Simulation and Analysis of Lightning on 345-kV Arrester Platform Ground-Leading Line Models

Power Quality and Reliablity Centre

ABSTRACT 1.0 INTRODUCTION LIST OF SYMBOLS

Lightning performance of a HV/MV substation

Electrical Power Systems

Simplified Approach to Calculate the Back Flashover Voltage of Shielded H.V. Transmission Line Towers

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1402 HIGH VOLTAGE ENGINEERING UNIT I

PRACTICAL PROBLEMS WITH SUBSTATION EARTHING

PREVENTING FLASHOVER NEAR A SUBSTATION BY INSTALLING LINE SURGE ARRESTERS

Study of Tower Grounding Resistance Effected Back Flashover to 500 kv Transmission Line in Thailand by using ATP/EMTP

Cable Protection against Earth Potential Rise due to Lightning on a Nearby Tall Object

Parameters Affecting the Back Flashover across the Overhead Transmission Line Insulator Caused by Lightning

EE 1402 HIGH VOLTAGE ENGINEERING

Fault location on power cables. Fault location on power cables

LIGHTNING OVERVOLTAGES AND THE QUALITY OF SUPPLY: A CASE STUDY OF A SUBSTATION

III/IV B.Tech (Regular/Supplementary) DEGREE EXAMINATION

Lightning Strikes. Presented to the Greater Norwalk Amateur Radio Corporation Inc. February 8, 2017 Steven M. Simons W1SMS

Field Instruction. Induced voltages can occur in overhead lines, underground cables, or in switchyards.

SOFTWARE FOR CALCULATING ELECTRICAL POWER TRANSMISSION LINE PARAMETERS

Transmission Line Transient Overvoltages (Travelling Waves on Power Systems)

FAQ ON EARTHING STANDARDS 16/08/2018

Computation of Inter-turn Voltages in Transformer Windings with Interconnected Distribution Cable

EMC Philosophy applied to Design the Grounding Systems for Gas Insulation Switchgear (GIS) Indoor Substation

Lightning Current Observation on UHVAC Transmission Lines by Improved Magnetic Steel Rod Method

National Radio Astronomy Observatory Socorro, NM EVLA Memorandum 41 Lightning Protection for Fiber Optic Cable. T. Baldwin June 05, 2002

SURGE PROPAGATION AND PROTECTION OF UNDERGROUND DISTRIBUTION CABLES

Equipment Rack Grounding. Technical Note

Introduce system protection relays like underfrequency relays, rate of change of frequency relays, reverse - power flow

X International Symposium on Lightning Protection

The relationship between operating maintenance and lightning overvoltage in distribution networks based on PSCAD/EMTDC

Network Standard NETWORK. Document No Amendment No Approved By Approval Date Review Date NW000-S0142 : : : : : Head of AEP&S 08/06/ /06/2017

OVERVOLTAGE PROTECTION OF POLE MOUNTED DISTRIBUTION TRANSFORMERS

3. COMBINED TRANSFORMERS Oil-paper insulation

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

Underground System Design TADP 547

Comparison of CAN/CSA C88.1, IEEE C /01 & IEC 60137

Overvoltage Protection

II Design Criteria for Electrical Facilities Connected to the PJM 765 kv, 500 kv, 345 kv, 230 kv, 138 kv, 115 kv, & 69 kv Transmission Systems

Sensitivity Analysis of Maximum Overvoltage on Cables with Considering Forward and Backward Waves

Switching Induced Transients:

EVALUATION OF THE EARTH RESISTANCE VALUE FOR ESE LIGHTNING ARRESTOR TECHNIQUE FOR THE SOLAR PLANTS IN INDIA

Effect of High Frequency Cable Attenuation on Lightning-Induced Overvoltages at Transformers

Great Northern Transmission Line: Behind the (Electrical) Design

Coaxial Cable Protection

AC Voltage- Pipeline Safety and Corrosion MEA 2015

Lecturer: Dr. J B E AL-ATRASH No. of Pages: 4

Simulation of Lightning Transients on 110 kv overhead-cable transmission line using ATP-EMTP

Lightning Flashover Rate of an Overhead Transmission Line Protected by Surge Arresters

FERRORESONANCE - its Occurrence and Control in Electricity Distribution Networks

Including Surge Arresters in the Lightning Performance Analysis of 132kV Transmission Line

Effective Elimination Factors to the Generated Lightning Flashover in High Voltage Transmission Network

INTEGRATED METHOD IN ELECTROMAGNETIC INTERFERENCE STUDIES

CHOICE OF MV FEEDER BIL TO MAXIMIZE QOS AND MINIMIZE EQUIPMENT FAILURE

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

MAHALAKSHMI ENGINEERING COLLEGE

Should we transform our lines to HVDC?

Lightning phenomena and its effect on transmission line

Testing of 400 kv GIS

R10. III B.Tech. II Semester Supplementary Examinations, January POWER SYSTEM ANALYSIS (Electrical and Electronics Engineering) Time: 3 Hours

Electro-Magnetic Transients

Power Quality. Case Study. Conrad Bottu Laborelec January 2008

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

Abstract. 1 Introduction

6B.6 Substation Grounding

Need for grounding Codes and Standards for grounding Wind Turbine Generator grounding design Foundation + Horizontal Electrode grounding design

Transcription:

Transmission of Electrical Energy Electrical energy is carries by conductors such as overhead transmission lines and underground cables. The conductors are usually aluminum cable steel reinforced (ACSR), with steel core and aluminum conductors wrapped around the core. In addition to phase conductors, a transmission line include one or two steel wires known as ground or shield wires. Cable lines are designed to be placed underground or under the water. In cables, the conductors are insulated from each other and surrounded by a protective sheath. They are more expensive than overhead power lines. Transmission lines are characterized by a series resistance and conductance per unit length, and by a shunt capacitance per unit length. 1

Models: Two-wire Conductor and a Coaxial Cable R and L C Jacket Braid Shield Dielectric Conductor ρl RDC = A µ 1 D L = + ln H/m ( r : radius of ε 4 r πε C = ( ε : dielectric constant) D ln r ( ρ : resistivity, l :length, A : cross - sectional area) each conductor, D : distance between conductors) 2

Transmission Line Limits The maximum steady-state line current must be limited to prevent overheating in the transmission line. The power loss in a transmission line is approximately given by: P loss = 3I The voltage drop in a practical transmission line should be limited to about 5%. 2 L R The angle δ in a transmission line should be less than 30o. This limitation ensures the power flow in a transmission line is well below the static stability limit, ensuring that the power system can handle transients in a stable manner. 3

Generation, Transmission, and Distribution GENERATION TRANSMISSION DISTRIBUTION G1 345 kv Interconnection Transmission Substation Substation 2.4 kv 115 kv 230 kv Distribution Substation 1-phase 120/240 V to 69 kv 3-phase G2 765 kv Generators Transmission Substation Heavy industry Medium industry Small-scale industry and residences 4

Types of Power Lines Low-Voltage (LV) Lines: Provide power to building, factories, and houses. The lines may be overhead or underground operating at 600 V or less. High-Voltage (HV) Lines: The voltage is usually between 2.4 kv and 69 kv. Such systems are preferred in large cities. The transmission lines spread out like fingers from one or more substation to various loads such as campuses, shopping centers, etc. Extra-High-Voltage (EHV) Lines: They connect the main substations to the generating plants. Such lines operate at voltages up to 800 kv and may be as long as 1000 km. 5

Lightning Strokes Charge separation takes place inside clouds, so that positive charges move to the upper part of the cloud while negative charges stay below. The transfer of electric charges sets up an electric field within the cloud. Also the negative charges at the base of the clouds repels the free electrons on the ground below and accordingly the ground becomes positively charged. + + + + + + _ + + + + 6

Lightning and Transmission Lines When lightning makes a direct hit on a transmission line, it deposits a large electric charge, producing an enormous over voltage between the line and ground. The dielectric strength of air is exceeded and the flashover occurs. The line discharge itself and the over voltage disappears in less than 50 microsecond. Adequate protection against lightning requires good grounding. 20 ka 69 kv BIL Insulating Material neutral Solid Electrical Ground (20 ohm) BIL: Basic Impulse Insulation 7

Example: A 3-phase 69 kv transmission line having a BIL of 300 kv is supported on steel towers and protected by a circuit breaker. The ground resistance at each tower is 20 ohm. The neutral of the transmission line is also grounded at the transformer just ahead of the circuit breaker. During an electric storm, one of the towers is hit by a lightning stroke of 20 ka. Find the voltage across each insulator. V phase = 69 kv/ 3 = 40 kv The current flowing in the tower ground is zero. When lightning strikes, the voltage across the line resistance is 20 ka 20 ohm = 400 kv.this voltage will appear across each insulator.since the impulse exceeds BIL of 300 kv, a flashover will occur. 8