SMALL-SIZE BETATRON FOR THE ENERGY 2.5 MEV FOR FIELD INSPECTION

Similar documents
Mobile digital radiography system for nondestructive testing of large diameter pipelines

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

X-RAYS - NO UNAUTHORISED ENTRY

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

Electron Linacs for Cargo Inspection and Other Industrial Applications

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

Philip Sperling. Sales Science and New Materials, YXLON International GmbH, Essener Bogen 15, Hamburg, Germany.

Advanced Digital Radiography for Field NDT

Hardware for High Energy Applications 30 October 2009

ProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX.

» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique

Performance evaluation of a photon counting detector for high energy NDT applications

v tome x m microfocus CT

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

ON THE WAY TO DIGITAL RADIOGRAPHY

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

High Energy Digital Radiography & 3D-CT for Industrial Systems

Film Replacement in Radiographic Weld Inspection The New ISO Standard

The field deployable digital X-Ray solution for weld inspection in O&G

Y.MU 2000 Precise inspection results for sampling and 100% inspection

CIRCLEX 0.3/0.8P324&0.6/1.2P324DK-85

China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW, 150kV Radiography System - HF50-R

NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS

Veraviewepocs 2D High Speed Panoramic X-Ray Crystal Clear Images with Reduced Radiation

Discover the difference in efficiency

Computed Radiography

AMA28XXD SERIES 28V Input, Dual Output HYBRID - HIGH RELIABILITY RADIATION TOLERANT DC/DC CONVERTER. Description AMA. Features.

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Digital Radiography for the Inspection of Small Defects

Linear electron accelerators for radiation processing MIKHAIL DEMSKY, CORAD LTD, ST. PETERSBURG, RUSSIA (

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

Cartogam Real-Time Portable Gamma-Ray Imaging System

AMR28XXD SERIES. 28V Input, Dual Output HYBRID-HIGH RELIABILITY RADIATION TOLERANT DC-DC CONVERTER PD-94690E AMR

THE CR SPECIALISTS HD-CR CR 35 NDT

FOCUS. Quick Industrial X-ray Testing Without Intermediate Data Carriers of Information. by V.A. Troitskiy

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

X-RAY IMAGING EE 472 F2017. Prof. Yasser Mostafa Kadah

Amorphous Selenium Direct Radiography for Industrial Imaging

AMA28XXS SERIES 28V Input, Single Output RADIATION TOLERANT DC/DC CONVERTERS. Description AMA. Features. 1 PD A

Practix. Mobile Radiography. Changing its point of view comes naturally. Practix 300

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

NEW POSSIBILITIES OF RADIATION CONTROL OF QUALITY OF WELDED JOINTS

NON DESTRUCTIVE TESTING 2 MARK QUESTION & ANSWERS UNIT I

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded

Flash-Radiography Instead of Traditional Radiography with Intermediate Carriers of Information

Precision Performance Power

Ensuring Shielding adequacy in Lead shielded spent fuel transportation casks using gamma scanning

ODYSSEY HF SERIES. ULTRA High Frequency X-Ray Technology. Precision... Performance... Power. Innovations in Digital Imaging.

NDT-PRO Services expands service offering

Fig.2: Scanner VistaScan for image plates

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors

Calibration of KAP meters

BF-X2. In-line 3D automated X-ray inspection system for Semiconductor, Power module inspection

AMA28XXS SERIES. 28V Input, Single Output HYBRID-HIGH RELIABILITY RADIATION TOLERANT DC-DC CONVERTER PD-94687G AMA

LPX SERIES Constant Potential Portable X-Ray

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.

digital radiography r High-energy DT Applications lior Pick, Ron Pincu and Ofra Kleinberger over film radiog- p P This advanced

IBEX MATERIALS DETECTION TECHNOLOGY

JEFFERSON COLLEGE COURSE SYLLABUS BET220 DIAGNOSTIC IMAGING. 3 Credit Hours. Prepared by: Scott Sebaugh Date: 2/20/2012

Diffraction-enhanced X-ray Imaging (DEXI) Medical Solutions. More information using less radiation

EMA TRANSFORMATION IN PULSED MAGNETIC FIELD AND ITS USE IN PORTABLE INSTRUMENTS FOR ACOUSTIC MEASUREMENTS

Monochromatic X-ray sources based on Table-top electron accelerators and X-ray tubes. A.P. Potylitsyn TPU, Tomsk, Russia

Experiences of users in Digital Radiography

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

PD233: Design of Biomedical Devices and Systems

NDE SOLUTIONS RADIOGRAPHY COURSE OUTLINE

Practix. Mobile Radiography. Constantly on the move, and yet never tired. Practix 160

MXHF-1500RF is controlled by Digital key panel console that displays KV, ma and mas with APR menu programmed.

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

Digital radiography. bucky table and wall stand as a dual detector or wireless system. Amadeo DR Systems

Distributed by. Ecotron Anyview Series. The Intelligent C-Arm System

RADIOGRAPHIC EXPOSURE

Photomultiplier Tube

Digital Radiography and its Advantages in Field NDT Inspections Today

QUANTITATIVE COMPUTERIZED LAMINOGRAPHY. Suzanne Fox Buchele and Hunter Ellinger

APPENDIX K UNF RADIATION GENERATING DEVICE SAFETY PROCEDURES

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

INTRODUCTION. Strong Performance: High resolution and penetration, achieving precise flaw detection

CARESTREAM INDUSTREX Digital Imaging Plates

I. Introduction.

Welding Inspection Non-Destructive Testing Course Reference WIS 5

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

Minnesota Rules, Chapter 4732 X-ray Revision

Radiation Detection Instrumentation

X-RAY BACKSCATTER IMAGING: PHOTOGRAPHY THROUGH BARRIERS

HIGH FREQUENCY X-RAY MONOBLOCK 3.5kW

2014 CINDE Toronto Portable X-ray & X-Ray Production

X-rays in medical diagnostics

X-ray light valve (XLV): a novel detectors technology for digital mammography*

CARESTREAM INDUSTREX Digital Imaging Plates

HPX1-Plus. For Non-Destructive Testing. THE BENCHMARK IN COMPUTED RADIOGRAPHY.

Beam-Restricting Devices

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

Engineering Policy & Procedure

Part 3: Image quality classes

Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT

Transcription:

SMALL-SIZE BETATRON FOR THE ENERGY 2.5 MEV FOR FIELD INSPECTION V. G. Volkov, Yu. D. Zrelov, V. A. Kasyanov, A. A. Filimonov, V. L. Chakhlov, M. M. Shtein State educational institution of higher professional training Tomsk polytechnic university, Research institute of introscopy, Russia P. Marjoribanks, John Macleod Electronics Ltd., UK The report presents the main characteristics of a betatron for the peak energy 2.5 MeV MIB-2.5D (PXB-2.5D). The unit is designed for field inspection of products with the equivalent steel thickness 120 mm. Small-size betatrons as X-ray sources for non-destructive testing have certain advantages over other accelerators and radionuclide sources. They have a rather high radiation energy, small focal spot, possibility to adjust the maximum energy, and continuous bremsstrahlung range. Besides, the energy being the same, betatons are smaller in size, lighter and much cheaper than microtrons or linear accelerators. Radiation safety issues are easier solved for small-size betatrons rather than for radionuclide sources [1, 2]. Low radiation dose rate is the betatron s weak point, that is why betatron developers have always aimed at increasing it. In the recent models of small-size betatrons, the dose rate has increased 15-20 times compared to the first units, the dimensions and weight being the same. As sensitive equipment for radiation detection is developing (digital radiography, scanning systems with scintillation detector lines), the lower dose rate is becoming less significant. These two opposite factors significantly extend the sphere of betatron application. A more widespread use of betatrons in cargo inspection facilities for vehicle examination is an example [3, 4]. The number of such facilities has risen to above 100. At present, small-size betatrons for 4 MeV (MIB-4), 6 MeV (MIB-6), and 7.5 MeV (MIB-7.5) are widely used to X-ray materials and products. Depending on the energy, they allow X-raying products of the equivalent steel thickness from 150 to 250 mm. Betatrons of that kind in the amount of 15-20 units per year are sold both in Russia and abroad. John Macleod Electronics Ltd (Great Britain) is a betatron dealer covering European countries and United States. It also performs service maintenance of betatrons. MIB-4, MIB-6 and MIB-7.5 models can be used in transient conditions, however a rather large weight of 65 kg (MIB-4) to 110 kg (MIB-7.5), and overall weight being 120-180 kg, makes it more difficult to use them. As a rule, in transient conditions these units are mainly used in emergency situations. Many Western companies specializing in NDT of pipelines, bridges and buildings under construction have addressed JME asking to supply a betatron for replacement of radionuclide sources to be used in field conditions. RII and Foton Ltd have joined their efforts to develop a betatron of that kind. The major task was finding a compromise between the dose rate, unit weight and consumed power. The developed betatron is named as MIB-2.5D for the Russian market, and PXB-2.5D (portable X- ray betatron) when exported.

Brief technical characteristics of the betatron are given below. 1. Peak energy of accelerated electrons 2. Adjustment range of the energy of accelerated electrons with 0.1 MeV steps 3. Guaranteed bremsstrahlung dose rate at 1 m distance from the target, at the peak energy 4. Maximum size of the focal spot 5. Maximum power consumption from AC mains at 50, 60 Hz, voltage 220 V with permitted deviations from the nominal value ±10%, not more than 6. Betatron operation cycle is 60 min of operation, 15 min of interval with fans on 7. Minimum size of the work field at 1 m focal distance and darkening nonuniformity not more than 10% 8. Relative radiographic sensitivity for steel at more than 50 mm thicknesses (D7 film with lead shields), focal distance 1 m, optical density 2.5 9. Dimensions of units, mm: radiator pulse converter power supply unit control panel remote dosimeter unit of visual alarm 10. Weight of betatron units, not more than, kg: radiator (without support) pulse converter power supply unit control panel remote dosimeter unit of visual alarm 2.5 MeV 1.0 2.5 MeV 0.7 R/min 0.2 2 mm 0.8 kw 350 350 mm 1-1.5 % 440 300 150 415 205 240 445 245 390 235 200 115 70 53 26 Ǿ 140 80 30 10.5 20 1.5 0.3 1.5 Structurally the betatron consists of five units: radiator, pulse converter, power supply unit, control panel and remote dosimeter. Figs. 1 and 2 show the radiator and control panel.

Fig. 1. Betatron radiator Radiator is the heart of a small-size betatron; it consists of electromagnet, sealed-off accelerating chamber, and a transition ionization chamber. Fig. 2. Betatron control panel

The pulse converter contains injection, expansion and contractor systems, as well as a converter to supply those systems. Departure from traditional arrangement of injection, expansion and contractor systems inside the radiator is a result of the necessity to minimize weight and dimensions of the latter. The power supply unit contains rectifier and power factor corrector (PFC), current pulse generator to feed the electromagnet, and module of automatic control system. PFC presence allows supplying betatron in field conditions from a self-contained power source (usually petrol-electric generating set) without the required significant reactive power allowance. The automatic betatron control system provides input of the source data (setting of the energy of accelerated electrons, exposure time, output dose and dose behind the test object), adjustment of the accelerator for maximum radiation, diagnostics of the operating modes of betatron units, automatic shutdown as per the source data. The unit is equipped with a remote dosimeter that allows setting a correct exposure the absorber thickness being unknown. It is recommended to use MIB-2.5D for X-raying welding joints and castings from 30 to 120 mm thick in steel, as well as building constructions of concrete and other materials from 100 to 300 mm thick. An exposure nomogram for steel is shown in Fig. 3. Time, min Thickness of a steel absorber, mm Fig. 3. Exposure chart for steel (focal distance 1m, D7 film, optical density 2,0, charging 0,5 Pb Film 1.0 Pb)

Starting from 50 mm steel thickness, MIB-2.5D in its characteristics is superior to the best types of X-ray units. If we compare one of the latest models of YXLON International company recommended for field operation, namely 300 kv Y.SMART 300HP [5] unit, we have the following results. The weight of X-ray and betatron radiators is about the same (30 and 33 kg respectively), power consumed is also similar (800 and 900W). The exposure time during X-raying steel absorber 50 mm thick is the same however X-ray unit manufacturer claims the maximum X- rayed thickness 65 mm, whereas for betatron this number is 120 mm. Moreover, focal spot sizes in betatron are much smaller than in an X-ray device. In conclusion, the armoury of NDT instruments in field conditions has renewed with another X-ray source, the use of which is most expedient for the range of thicknesses from 50 to 120 mm of steel. References 1. V. L. Chakhlov et al. Development, production and application of small-size sources of X- ray and electron radiation. Izv. TPU, vol. 312, 2, 2008, pp. 23-32 2. M. Stein et al. Small-size betatrons for radiographic inspection. 16 th World Conference on NDT (2004). 3. Smiths Detection Inc. Smiths Detection - HCVC 250300-2is // URL:http://www.smithsdetection.com/eng/HCVC_250300-2is.php, (2009, 29 Dec.). 4. Science Applications International Corporation (SAIC) LTD. SAIC: Products: Safety & Security. // URL:http://www.saic.com/products/security/pdf/VACIS-P-7500.pdf, (2009, 29 Dec.). 5. YXLON International GmbH. YXLON - industrial X-ray inspection systems and CT systems - Y.SMARTS - Portable X-ray Systems. // URL: http://www.yxlon.com/yxlon/ yxlon_cms.nsf/reffileupload/idc65c1730ed0bb423c125704d002764c8/$file/y.sm ART-En.pdf, (2009, 29 Dec.).