497 Compact Size Sensor NA-PK SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.59~ Sensor selection guide... P.475~ General precautions...p.5 PHOTO PHOTO Conforming to EMC Directive Recognition MEASURE Boasts a compact, pocket lighter size enabling universal installation PNP output type available Make sure to use light curtains when using a sensing device for personnel protection. Interference prevention Space-saving, pocket lighter-sized unit Ultra compact size: W4 H7 D8 mm W.945 H.756 D.5 in. Can even be mounted within the small space constraints of parts containers. Utilizes a large, bright, clearly visible job indicator The ultra compact body incorporates a job indicator approx. 5 mm.969 in tall. Due to its brightness and high visibility, it is now possible to check sensor operation even from a distance. 4 mm.945 in 8 mm.5 in NA-PK Pocket lighter 7 mm.756 in NA-PK5/ NA-5 NA-PK Phone: 8.894.4 - Fax: 888.7.477 - Web: www.clrwtr.com - Email: info@clrwtr.com
Compact Size Sensor NA-PK SERIES 498 APPICATIONS Cell production line Assembly line PHOTO PHOTO BASIC PERFORMANCE No synchronization wires required Synchronization wires are not required, due to the utilization of a synchronized scanning system that results in a reduction of wiring man-hours. In addition, the sensors can be switched among three different emission frequencies, allowing up to three sets of sensors to be installed closely together in the same vertical plane, without causing mutual interference. Even when installed in multistage shelving, malfunctions due to mutual interference will not occur. (When mounted horizontally, a maximum of two sensor sets may be used side-byside, without interference.) FUNCTIONS Switchable output operation Output operation can be switched to suit the desired application. Sensor protection brackets are available Sensor protection brackets are now available (optional), to protect sensors from damage due to tools and other objects. The protection brackets have a black coating, which enhances the visual effectiveness of the job indicator. MEASURE MOUNTING Easy alignment The sensor s beam axis is directly in line with the mounting holes, making sensor alignment easier. Mounting can be performed simply by using M4 nuts. Mounting hole Flexible cable orientation The cabling can be oriented in either of the two different directions: downward or sideways, thus permitting a flexible layout, in accordance with the sensor s mounting position. NA-PK5/ NA-5 NA-PK Mounting hole Phone: 8.894.4 - Fax: 888.7.477 - Web: www.clrwtr.com - Email: info@clrwtr.com
499 Compact Size Sensor NA-PK SERIES ORDER GUIDE Type Appearance Sensing range (Note ) Model No. (Note ) Output NPN output PNP output beam channels Sensing height 49. mm.97 in Beam pitch 4.6 mm in to mm.8 to.8 in Notes: ) The sensing range is the possible setting distance between the emitter and the receiver. cannot be placed in this range Actual sensing range of the sensor mm.8 in Setting range of the receiver mm.8 in NA-PK NA-PK-PN NPN open-collector transistor PNP open-collector transistor ) The model No. with P shown on the label affixed to the product is the emitter, D shown on the label is the receiver. (e.g.) of NA-PK: NA-PKP, of NA-PK: NA-PKD 5 m 6.4 ft cable length type, pigtailed type 5 m 6.4 ft cable length type (standard: m 6.56 ft) and pigtailed type (standard: cable type) are also available. Table of Model Nos. Type Standard type 5 m 6.4 ft cable length type Pigtailed type (Note) NPN output NA-PK NA-PK-C5 NA-PK-J PNP output NA-PK-PN NA-PK-PN-C5 NA-PK-PN-J Note: Please order the suitable mating cable separately for pigtailed type. Mating cable ( cables are required.) Model No. CN-4-C CN-4-C5 Description 4-core, cable length m 6.56 ft 4-core, cable length 5 m 6.4 ft mm.8 in ø4 mm ø.55 in Mating cable NA-PK5/ NA-5 NA-PK Designation Model No. Description Sensor protection bracket Y-shaped connector MS-NA- S-WY 5 pcs. per set It protects the sensor body. Two black bracket set Four M4 (length 5 mm.59 in) screws with washers, and four nuts are attached. This connector is able to combine the cables of receiver and emitter into one. Sensor protection bracket MS-NA- Two bracket set Four M4 (length 5 mm.59 in) screws with washers, and four nuts are attached. Y-shaped connector S-WY Y-shaped connector S-WY ø4 mm.55 in mm.8 in Mating cable CN-4-C CN-4-C5 Phone: 8.894.4 - Fax: 888.7.477 - Web: www.clrwtr.com - Email: info@clrwtr.com
Compact Size Sensor NA-PK SERIES 5 SPECIFICATIONS Type NPN output PNP output Item Model No. NA-PK NA-PK-PN Sensing height Sensing range (Note ) Beam pitch Number of beam channels Sensing object Supply voltage Current consumption Output 49. mm.97 in to mm.8 to.8 in 4.6 mm in beam channels ø9 mm ø.4 in or more opaque object (completely beam interrupted object) NPN open-collector transistor Maximum sink current: ma Applied voltage: V DC or less (between output and V) Residual voltage: V or less (at ma sink current).4 V or less (at 6 ma sink current) to 4 V DC ± % Ripple P-P % or less : ma or less, : 5 ma or less PNP open-collector transistor Maximum source current: ma Applied voltage: V DC or less (between output and +V) Residual voltage: V or less (at ma source current).4 V or less (at 6 ma source current) Utilization category Output operation Short-circuit protection DC- or DC- ON or OFF when one or more beam channels are interrupted, selectable by operation Incorporated Response time Indicators ms or less (when interference prevention function is used: ms or less) Power indicator: Green ED (lights up when the power is ON) : Orange ED (lights up when the job indicator input is ow) Operation indicator: Red ED (lights up when the output is ON) Stable incident beam indicator: Green ED (lights up when all beam channels are stably received) : Orange ED (lights up when the job indicator input is ow) Power indicator: Green ED (lights up when the power is ON) : Orange ED (lights up when the job indicator input is High) Operation indicator: Red ED (lights up when the output is ON) Stable incident beam indicator: Green ED (lights up when all beam channels are stably received) : Orange ED (lights up when the job indicator input is High) Interference prevention function Incorporated (Up to units can be mounted close together.) (Note ) Environmental resistance Pollution degree Protection (Industrial environment) IP6 (IEC) Ambient temperature to +55 C +4 to + F (No dew condensation or icing allowed), Storage: to +7 C 4 to +58 F Ambient humidity Ambient illuminance 5 to 85 % RH, Storage: 5 to 85 % RH Incandescent light:, lx at the light-receiving face EMC EN 6947-5- Voltage withstandability Insulation resistance, V AC for one min. between all supply terminals connected together and enclosure MΩ, or more, with 5 V DC megger between all supply terminals connected together and enclosure Vibration resistance to 5 Hz frequency,.75 mm. in (5 G max.) amplitude in X, Y and Z directions for two hours each Shock resistance Emitting element Material extension Net weight 5 m/s acceleration (5 G approx.) in X, Y and Z directions for three times each Infrared ED (synchronized scanning system) Enclosure: Heat-resistant ABS, ens cover: Acrylic, Indicator cover: Acrylic. mm 4-core (emitter: -core) oil resistant cabtyre cable, m 6.56 ft long Extension up to total m 8.84 ft is possible for both emitter and receiver with. mm, or more, cable. : 5 g approx., : 5 g approx. Notes: ) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of + C +7.4 F. ) The sensing range is the possible setting distance between the emitter and the receiver. cannot be placed in this range Actual sensing range of the sensor mm.8 in Setting range of the receiver mm.8 in NA-PK5/ NA-5 NA-PK ) For more details, refer to the Interference prevention function in PRECAUTIONS FOR PROPER. Phone: 8.894.4 - Fax: 888.7.477 - Web: www.clrwtr.com - Email: info@clrwtr.com
5 Compact Size Sensor NA-PK SERIES I/O CIRCUIT AND WIRING DIAGRAMS NPN output type I/O circuit diagram Sensor circuit Tr D Internal circuit ZD lighting circuit E Color code / Connector pin No. of the pigtailed type (Brown / ) +V (Black / 4) Output (Note ) ma max. (Blue / ) V (Pink / ) Job indicator input (Note )(Note ) Users circuit oad * + to 4 V DC ± % Symbols D : Reserve supply polarity protection diode ZD: Surge absorption zener diode Tr : NPN output transistor E : (IND.) * Non-contact voltage or NPN opencollector transistor or input ow ( to V): ights up High (5 to V, or open): ights off Notes: ) The emitter does not incorporate the output (black). ) If a mating cable is connected to the pigtailed type, then the lead wire color is white. ) When the job indicator is used as a large size operation indicator, connect the job indicator input wire (pink) of the emitter and the receiver to the output wire (black) of the receiver. PNP output type I/O circuit diagram Sensor circuit Color code / Connector pin No. of the pigtailed type (Brown / ) +V Tr Z D ma max. (Black / 4) Output (Note ) D (Blue / ) V oad (Pink / ) Job * indicator input lighting circuit (Note )(Note ) Internal circuit E Users circuit + to 4 V DC ± % Connector pin position (Pigtailed type) input Symbols D : Reserve supply polarity protection diode ZD: Surge absorption zener diode Tr : PNP output transistor E : (IND.) * Non-contact voltage or PNP opencollector transistor Notes: ) The emitter does not incorporate the output (black). ) If a mating cable is connected to the pigtailed type, then the lead wire color is white. ) When the job indicator is used as a large size operation indicator, connect the job indicator input wire (pink) of the emitter and the receiver to the output wire (black) of the receiver. or input High (4 to V): ights up ow ( to.6 V, or open): ights off +V 4 Output (Note ) V Notes: ) No connection is required for the emitter. ) The pin position for the S-WY Y-shaped connector (optional) is identical to the receiver. Connector pin position (Pigtailed type) input V +V 4 Output (Note ) Notes: ) No connection is required for the emitter. ) The pin position for the S-WY Y-shaped connector (optional) is identical to the receiver. SENSING CHARACTERISTICS (TYPICA) Parallel Vertical direction 5.748 Horizontal direction 5.748 l Setting distance (mm in).8.97 l Setting distance (mm in).8.97 NA-PK5/ NA-5 NA-PK.575.787.787 Down Center Up Operating point l (mm in).575.575.787.787 eft Center Right Operating point l (mm in).575 Angular Vertical direction emitter angular 5.748 Horizontal direction emitter angular 5.748 θ Vertical direction receiver angular θ Setting distance (mm in).8.97 angular angular Down Center Up Operating angle θ ( ) θ Horizontal direction receiver angular θ Setting distance (mm in).8.97 angular angular eft Center Right Operating angle θ ( )
Compact Size Sensor NA-PK SERIES 5 PRECAUTIONS FOR PROPER Part description (Orange) Mounting Power indicator (Green) Frequency Operation / frequency (Orange) Use M4 screws with washers and M4 nuts. The tightening torque should be.5 N m or less. (Purchase the screws and nuts separately.) of operation Stable incident beam indicator (Green) Operation indicator (Red) The output operation can be selected by the operation / frequency selection switch on the receiver. Make sure that the power supply is off while setting the selection switch. State of operation / frequency selection switch Never use this product as a sensing device for personnel protection. For sensing devices to be used as safety devices for press machines or for personnel protection, use products which meet standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. If this product is used as a sensing device for personnel protection, death or serious body injury could result. For a product which meets safety standards, use the following products. Type 4: SF4B series Type : SFB series M4 screws with washers M4 nuts Output operation OFF when one or more beams are interrupted. ON when one or more beams are interrupted. Notes: ) of the output operation and the frequency for the receiver is carried out with the same switch. When the output operation is set, be sure to select the same frequency No. of the emitter and the receiver. ) In case the operation / frequency selection switch is set to the position other than, or, the state of the receiver is in / frequency. Orientation The emitter and the receiver must face each other correctly. If they are set upside down, the sensor does not work. Interference prevention function Refer to General precautions. However, if the sensors are mounted close together as shown in the figure below, up to sets of sensors are possible. Frequency setting Set the both emitting and receiving frequency of Sensor to, the both emitting and receiving frequency of Sensor to and the both emitting and receiving frequency of Sensor to. Make sure that the power supply is off while setting the selection switch. Sensor Sensor Sensor Sensor Sensor Frequency selection switch Operation / Frequency selection switch Sensor Sensor Sensor By setting different emission frequencies, three units of NA-PK can be mounted close together, as shown in the figure on the below. Notes: ) Take care that selection of the output operation and the frequency for the receiver is carried out with the same switch. ) In case the frequency switch and the operation / frequency selection switch is set to the position other than, or, the state of the emitter is in frequency and that of the receiver is in / frequency. NA-PK5/ NA-5 NA-PK
5 Compact Size Sensor NA-PK SERIES Wiring PRECAUTIONS FOR PROPER Make sure that the power supply is off while wiring and setting the selection switch. Take care that wrong wiring may damage the sensor. Verify that the supply voltage variation is within the rating. If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of the sensor, connect the frame ground (F.G.) terminal of the equipment to an actual ground. Extension up to total m 8.84 ft is possible with. mm, or more, cable for both emitter and receiver. However, in order to reduce noise, make the wiring as short as possible. Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. DIMENSIONS (Unit: mm in) Refer to General precautions. Make sure to use an isolation transformer for the DC power supply. If an auto-transformer (single winding transformer) is used, this product or the power supply may get damaged. In case a surge is generated in the used power supply, connect a surge absorber to the supply and absorb the surge. s Do not use during the initial transient time (.5 sec.) after the power supply is switched on. Take care that the sensor is not directly exposed to fluorescent light from a rapid-starter lamp or a high frequency lighting device, as it may affect the sensing performance. Avoid dust, dirt, and steam. Take care that the product does not come in direct contact with water, oil, grease or organic solvents, such as, thinner, etc. To select the switch, a minus screwdriver is necessary. (Tip dimension:.5.6 mm.98.4 in) These sensors are only for indoor use. The CAD data in the dimensions can be downloaded from our website. NA-PK NA-PK-PN -ø4.5 ø.77 mounting through holes, M4 nut seats,.. deep Sensor 8.5 (Orange).4.9 4.6 4.6 4.945.5.8 Frequency 7 6.756.48 -ø4.5 ø.77 mounting through holes, M4 nut seats,.. deep.5.8 7 6.756.48 Operation / frequency 4.945.4.9 4.6 4.6 8.5 (Orange) Power indicator (Green) Stable incident beam indicator (Green) MS-NA- ø.7 ø.46 cable, m 6.56 ft long ø.7 ø.46 cable, m 6.56 ft long Operation indicator (Red) Sensor protection bracket (Optional) t.8 t. 4.4.96 8.4. NA-PK5/ NA-5.94 NA-PK 6.4 9.54.5.8 6.8.68 8.79 4.5.77 Material: Cold rolled carbon steel (SPCC) (Black chromate) Two bracket set Four M4 (length 5 mm.59 in) screws with washers and four nuts are attached. Note: The sensor protection bracket can be used for both the emitter and the receiver. 5..969.85 6..44.79.79 R R.8 6.6 R R.8.4.449 6.5.65 4.5.77.. R R.8 4.6 4.6 7.85.5.8 -ø4.8 ø.89.94 8.79 6.48.94 6.8.68