Drive Goods Junction Terminal Block For General-Purpose Interface Servo Amplifier. Model DG2SV1TB User's Manual (Detailed)

Similar documents
INVERTER INSTRUCTION MANUAL. 16-bit digital input function. Plug-in option PRE-OPERATION INSTRUCTIONS INSTALLATION CONNECTION DIAGRAM AND

Drive Safety integrated AC servo amplifier <MR-J3- S 0.1kW to 55kW> Safety logic unit <MR-J3-D05>

General-Purpose AC Servo J2-Jr Series General-Purpose Interface Compatible MODEL MR-J2-03A5 SERVO AMPLIFIER INSTRUCTION MANUAL

Proposing control by a hydraulic servo and V/F inverters

This section is specifically about safety matters

INVERTER INSTRUCTION MANUAL. 16 bit digital input function. Plug-in option FR-A7AX PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING

This section is specifically about safety matters

VECTOR INVERTER -INSTRUCTION MANUAL- 16-BIT DIGITAL INPUT FR-V5AH

FR-A7AX FR-A7AX E kit

Phase-sequence Phase-loss Relay

MR-J4-DU_B_-LL SERVO AMPLIFIER INSTRUCTION MANUAL

MR-J4-_A SERVO AMPLIFIER INSTRUCTION MANUAL

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

MDS-CH-SP PLG Adjustment(BNP-B H)

Information. AC Servo Motor Driver Series LECS. Incremental Type. Absolute Type. Series LECSA (Pulse Input Type/Positioning Type)

Digital Interface Option "OPC-E1-DIO"

General-Purpose AC Servo. General-Purpose Interface AC Servo SERVO AMPLIFIER INSTRUCTION MANUAL MR-JE-_A MODEL

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

Connection targets. Universal sensors and switches, universal output devices

TH450A-T TH550A-T THP550-T/TS3000

INSTRUCTIONS YASKAWA. Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

TECHNICAL BULLETIN [ 1 / 54 ]

General-Purpose AC Servo. General-Purpose Interface AC Servo SERVO AMPLIFIER INSTRUCTION MANUAL MR-JE-_A MODEL

PG Interface Card "OPC-E2-PG"

General-Purpose AC Servo. Instructions and Cautions for Drive of HC/HA Series Servo Motor with MR-J4-(DU)_B_-RJ020

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

User s Manual Current Probe IM E. 8th Edition

TOSVERT VF-PS1 series Metasys N2 option unit Instruction Manual MTS001Z

OPTITEMP TT 10 C/R Technical Datasheet

MELSEC iq-r Motion Controller Programming Manual (Advanced Synchronous Control) -R16MTCPU -R32MTCPU -R64MTCPU

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

TOSVERT VF-PS1 series BACnet option unit Instruction Manual BCN001Z

USER S MANUAL. AC Servo Drives -V-SD Series. Speed Reference with Analog Voltage Expanded Functions

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

MELSERVO-J4 series servo amplifier for connecting to SSCNET of MR-J2S-B is newly released.

Personal Computer Embedded Type Servo System Controller. Simple Motion Board User's Manual (Network) -MR-EM340GF

MR-J4-_B-RJ010 MR-J4-_B4-RJ010 MR-J3-T10 SERVO AMPLIFIER INSTRUCTION MANUAL. General-Purpose AC Servo

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

Σ-V Series USER'S MANUAL Setup Rotational Motor

DLP-PU/EJ Instruction Manual

Mounting method DIN rail mounting or screw mounting Screw mounting Mass [g] Material Case: Plastics PCB: FR-4

General-Purpose AC Servo. General-Purpose Interface AC Servo SERVO AMPLIFIER INSTRUCTION MANUAL MR-JE-_A MODEL

CC-Link Compatible AC Servo Amplifier <MR-J3-T type> with Built-in Positioning Function

MR-J4-_A4(-RJ) MR-J4_B4(-RJ) SERVO AMPLIFIER INSTRUCTION MANUAL

SERVO AMPLIFIERS & MOTORS

LA-T SERIES. Fast and reliable minute granular flaw detection in winding wires. Winding Wire Granular Flaw Detector PARTICULAR USE SENSORS

AFC Series AFC -20HG AFC-20SE

High Intensity LED Stroboscope Digital Tachometer DT-361/365. Instruction manual. Be sure to read before use.

OPTITEMP TT 20 Technical Datasheet

MITSUBISHI General-Purpose AC Servo D-S24 MR-J2- Specifications BCN-B

Σ-V Series USER'S MANUAL Setup Rotational Motor

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

FR-A8APR INSTRUCTION MANUAL

TOSVERT VF-PS1 series APOGEE FLN option unit Instruction Manual APG001Z

20 Series Power Relays

MR-E- A-KH003 MR-E- AG-KH003

Contents. Instruction Leaflet IL E Effective March HMi VU Series Instruction Leaflet. Description... Page. Preface...

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Handling Precaution for Terminal and Connector

User s Manual. Model MA5 Distributor (Free Range Type) CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT MODEL AND SUFFIX CODES

Galvanometer Scanner Driver GVD0 Series Instruction Manual

Top spin Nr /

INVERTER Plug-in option FR-A8AP INSTRUCTION MANUAL

USER S MANUAL. AC Servo Drives -V Series / -V Series for Large-Capacity Models / -7 Series. Safety Module. Model: SGDV-OSA01A.

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

FR-A8TP INSTRUCTION MANUAL

Palm-sized, 16-channel Relay Terminals

SMG Systems Service et Machines Graphiques. Servo Variateur RIMA MR-J2S-CP

G7 Adjustable Speed Drive PG Feedback Option Manual

General-Purpose AC Servo. Ethernet Interface SERVO AMPLIFIER INSTRUCTION MANUAL MR-JE-_C MODEL

/ Instruction Manual. Digital Input Interface Card "OPC-G1-DI" Digital Output Interface Card "OPC-G1-DO"

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

HITACHI INVERTER INSTRUCTION MANUAL

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Model Number Structure

User s Manual. Model MXS Universal Computing Unit (1-input, Isolated 2-output Type) MODEL AND SUFFIX CODES

Product Manual. -7-Series AC Servo Drive -7S SERVOPACK with FT/EX Specification for Application with Special Motor, SGM7D Motor

Displacement Sensor CD5 Series

MELSEC iq-r Simple Motion Module User's Manual (Startup) RD77MS2 RD77MS4 RD77MS8 RD77MS16

PH201G (Style B) Distributor

Precautions in Using the product:

General-Purpose AC Servo. MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

2015 RIGOL TECHNOLOGIES, INC.

KANEKA OLED Lighting Module SL (LE-01L, LE-02L, LE-03L, LE-01H, LE-02H, LE-03H) Instruction Manual

MELSEC iq-r Simple Motion Module User's Manual (Startup)

Shock Monitor. Model No.:TSM4000M1 TSM4000M1P. Contact Detection Type for Machine Tools CAUTION

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

User s Manual. Model MS5 Potentiometer Converter (Free Range Type) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

General-Purpose AC Servo. J2-Jr Series. SSCNET Compatible MODEL MR-J2-03B5 SERVO AMPLIFIER INSTRUCTION MANUAL

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Compact body with high performance

USER S MANUAL For Use with Large-Capacity Models Design and Maintenance

FR-A8TP INSTRUCTION MANUAL

AI controller. Mitsubishi Electric Air Conditioner Network System PAC-YG63MCA. Contents. Installation/Instruction Manual

Transcription:

Drive Goods Junction Terminal Block For General-Purpose Interface Servo Amplifier Model User's Manual (Detailed)

SAFETY PRECAUTIONS Before Using the Product Do not attempt to install, operate, maintain, or inspect this product until you have carefully read through this User's Manual and relevant documents and can use the equipment correctly. Do not use this product until you have a full knowledge of the equipment, safety information, and instructions. In this manual, the safety instruction levels are classified into "WARNING" and "CAUTION." WARNING CAUTION Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury. Indicates that incorrect handling may cause hazardous conditions, resulting in minor or moderate injury or property damage. Under some circumstances, failure to observe the precautions given under " CAUTION" may lead to serious consequences. Observe the precautions of both levels because they are important for personal and system safety. After reading this manual, keep the manual in a safe place for future reference.. Electric Shock Prevention WARNING Make sure that all wiring work and inspections are performed by professional engineers. Do not damage, apply unreasonable stress to, place heavy objects on, or pinch the cables. Doing so results in the risk of electric shock. To avoid electric shock, insulate the connection area of the power supply terminal. Be sure to shut off all phases of the external power supply used by the system before performing work such as installation and wiring. Failure to do so results in the risk of electric shock and product damage. 2. Fire Prevention CAUTION Be sure to install this product in a non-flammable object. Directly installing the product in a flammable object or installing the product near a flammable object results in the risk of fire. Do not allow any conductive foreign objects, such as a screw or metal fragments, or flammable foreign objects, such as oil, to enter the product interior.. Injury Prevention CAUTION Be careful to connect terminals correctly. Failure to do so results in the risk of explosion, damage, and the like. The polarity (+ and -) must be correct. Failure to do so results in the risk of explosion, damage, and the like. A-

. General Precautions Also note the following precautions. Incorrect handling may cause failure, injury, electric shock, and the like. () Transportation and Installation CAUTION This product is a precision instrument. During transportation, avoid impacts larger than those specified in general specifications. Failure to do so results in the risk of failure. Do not stand or rest heavy objects on the product. Do not install or operate units that are damaged or have missing parts. This product is a precision instrument. Do not drop or apply strong impact to the product. Use this product in an environment that reflects the general specifications set forth in the User s Manual. Usage in an environment outside of the scope of the general specifications results in the risk of electric shock, fire, malfunction, product damage, and/or product deterioration. When handling the product, be careful of sharp areas such as product corners. Be sure to place this product inside a metal enclosure. Reliably secure the module using a DIN rail. If the module is not properly mounted, risk of malfunction, failure, and falling results. If using the product in an environment with high vibration, secure the product with screws. Fumigants that contain halogen materials such as fluorine, chlorine, bromine, and iodine used for disinfecting and protecting wooden packaging from insects will cause malfunction in Mitsubishi Electric Engineering products. Please take necessary precautions to ensure that residual fumigants do not enter the product, or treat packaging with methods other than fumigation (heat method, etc.). Additionally, disinfect and protect wood from insects before packing. Noises are classified into external noises which enter the servo amplifier to cause it to malfunction and those radiated by the servo amplifier to cause peripheral equipment to malfunction. Since the servo amplifier is an electronic device which handles small signals, the general noise reduction techniques are required. Referring to the Servo Amplifier Instruction Manual for using, take the countermeasures. (2) Wiring CAUTION This product is dedicated for general-purpose AC servo amplifiers and extension I/O units for general-purpose AC servo amplifiers manufactured by Mitsubishi Electric, and SSCNET III/H analog speed command units manufactured by Mitsubishi Electric Engineering. Do not use the product for the products other than the specified products. For the connectable models, refer to chapter. Be sure to wire the product correctly. Failure to do so results in the risk of unexpected servo motor operation. The connection drawings in this manual are based on a sink interface, unless otherwise specified. Be careful to properly set the orientation of the diodes for surge absorption, which are attached to the DC relay for servo amplifier control signal output signals. Incorrect orientation results in the risk of the servo amplifier failure, which can cause signal output failure and malfunction of protective circuits such as emergency stop. Junction terminal block for Junction terminal block for general-purpose interface servo amplifier general-purpose interface servo amp lifier (D) Control output signal For sink output interface 2 VDC Always verify that the wiring is properly secured to the terminal block. Failure to adequately secure the wiring results in the risk of poor contact, which can cause heat generation from the wiring and terminal block. Properly connect the wiring to the module after first verifying the module rated voltage and terminal layout. Inputting or connecting the power supply to voltage that differs from the rated voltage and miswiring result in the risk of fire and product failure. Securely install the connector to the module. Failure to do so results in the risk of malfunction. Be sure that foreign matter such as dust and wire shavings does not enter the module interior. Failure to do so results in the risk of fire, failure, and malfunction. Be sure to secure the power lines and cables connected to the module by clamping them or placing them in a duct. If not, dangling cables may swing, move, or inadvertently be pulled, resulting in damage to the module or cables, or malfunction due to poor cable connection. A-2 (D) Control output signal For source output interface 2 VDC

CAUTION When disconnecting the cable connected to the module, do not pull the cable by the cable part. For cables with connectors, take hold of the connector connected to the module and then disconnect the connector. For cables connected to the terminal block, unlock the terminal board spring lock and then disconnect the connector. Pulling the connected cable may result in malfunction or damage to the module or cable. When connecting the servo amplifier, etc., verify that the product configuration is correct. Connecting the servo amplifier with a wrong configuration results in the risk of failure and malfunction. () Usage CAUTION Do not disassemble, repair, or modify the product. Never attempt to burn or disassemble the product. Doing so may cause generation of poisonous gas. Be careful when changing the output device assignments in servo amplifier parameters. Changing the MBR (electromagnetic brake interlock) signal assignments, in particular, may cause unexpected operation of the servo motor, damage, falling, and malfunction. () Emergency Handling CAUTION Ensure safety by confirming the power off, etc. before performing corrective actions. Otherwise, it may cause an accident. (5) Maintenance and Inspection CAUTION Before removing or installing the module, cut off all phases of the power supply externally. Failure to do so may cause module failure, malfunction, or damage. Connection/disconnection of the cables after the first use of the product shall be limited to times. (JIS B 2 compliant) Before handling the module, touch a grounded metal object to discharge the static electricity from your body. Failure to release the static electricity may cause the module to fail or malfunction. () General Instruction CAUTION When disposing of this product, treat it as industrial waste. A-

REVISIONS *The manual number is noted on the lower left of the back cover. Print Date *Manual Number Revision April 207 EN-0708-A First edition This manual confers no industrial property rights or rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual. 207 MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED A-

CONTENTS. OVERVIEW 2. GENEL SPECIFICATIONS. PERFORMANCE SPECIFICATIONS. CONNECTABLE MODELS AND CONNECTION CABLE 5. DIMENSIONS 2. INSTALLATION PROCEDURE 2-5 - Connection with servo amplifier... 2-2 Connection with SSCNET III/H analog speed command unit... - Wiring to spring clamp terminal block... - Attaching/detaching to the DIN rail... 5 7. CONNECTION DIM 9 7- Internal connection diagram of... 7-2 Connection diagram of DGSVCB_... 7 7- Connection diagram of DGAFCB_... 8 7- Connector dimensions... 9 8. EXTERNAL CONNECTION EXAMPLE 9-8- Branch of digital interface power supply... 9 8-2 Connection with MR-J-_A_(-RJ), MR-J-0A(-RJ), or MR-J-_DU_A_(-RJ)... 0 8- Connection with MR-D0... 8 8- Connection with DG2AF/DG2AF-P0... 20 9. APPLICABLE CRIMPING TERMINAL 22 - A-5

. OVERVIEW This User's Manual describes the specifications of the junction terminal block for general-purpose interface servo amplifiers used with general-purpose AC servo amplifiers and extension I/O units for general-purpose AC servo amplifiers manufactured by Mitsubishi Electric, and SSCNET III/H analog speed command units manufactured by Mitsubishi Electric Engineering. 2. GENEL SPECIFICATIONS Item Ambient Operating temperature Storage Ambient Operating humidity Storage Ambience Altitude Vibration resistance. PERFORMANCE SPECIFICATIONS Item External power supply Terminal block Global compliance standard Module mounting Weight Model name Specifications 0 to 55 C, no freezing -20 to 5 C, no freezing 90% RH or less, no condensation Indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust, and dirt 2000 m or less above sea level 5.9 m/s 2, at 0 to 55 Hz (in X, Y and Z directions) Voltage 2 VDC ±0 % Current capacity Number of points Applicable wire Wire strip length UL standard DIN rail A (max.) 0 points (wire: /wire insertion hole) 0.2 to.5 mm 2 (AWG2 to ), film φ2.8 mm or less 8 to 9 mm (Maximum wire film dimension φ2.8 mm or less) UL800-5- Applicable DIN rail: TH5-7.5Fe, TH5-7.5Al (JIS C 2 compliant) Approx. 80 g. CONNECTABLE MODELS AND CONNECTION CABLE Connectable model MELSERVO-J general-purpose interface Servo amplifier MELSERVO-J extension I/O unit Drive Goods SSCNET III/H analog speed command unit MR-J-_A_(-RJ) MR-J-0A(-RJ) MR-J-_DU_A_(-RJ) MR-D0 DG2AF DG2AF-P0 Note : MELSERVO is a registered trademark of Mitsubishi Electric Corporation. Connection cable model DGSVCB05 (Length: 0.5 m) DGSVCB0 (Length: m) DGAFCB05 (Length: 0.5 m) DGAFCB0 (Length: m)

5. DIMENSIONS 0.2-.5 MADE IN JAPAN MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED 2 0 5 7892 5 2 5 7 8 9 0 2 5 78 9 20 22 2 [Unit: mm]. INSTALLATION PROCEDURE -. Connection with servo amplifier Securely fix the connector until it is locked. Connection cable DGSVCB05 DGSVCB0 Insert the connector all the way down and fix it securely. Servo amplifier MR-J-_A_(-RJ), etc. 0.2-.5 MADE IN JAPAN MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED 205 7892 5 2 5 7 8 9 0 2 5 78 9 20 22 2 2

-2. Connection with SSCNET III/H analog speed command unit Securely fix the connector until it is locked. Connection cable DGAFCB05 DGAFCB0 Insert the connector all the way down and fix it securely. SSCNET III/H analog speed command unit DG2AF, etc. 0.2-.5 MADE IN JAPAN MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED 205 7892 5 2 5 7 8 9 0 2 5 78 9 20 22 2 -. Wiring to spring clamp terminal block () Installing the cable When wiring the terminal block, use a ferrule terminal with the sheath removed. In the case of a single wire, you can use the wire as is with the sheath removed. Insert the ferrule terminal or single wire from the wire insertion hole and execute wiring. ) Remove the sheath in an amount equivalent to the dimensions below. If the length of the sheath peeled is too long, a short circuit may occur with neighboring wires. If the amount of removed sheath is too short, the wiring may disengage. Wire the stripped cable after twisting it to prevent it from becoming loose. In addition, do not solder it. Cable sheath stripping length 8 to 9 mm 2) Insert the ferrule terminal into the wire and crimp the wire. Insert the terminal until the wire core section sticks out a bit from the ferrule. After crimping, check the outer appearance of the ferrule terminal. Do not use any ferrule terminal that is not properly crimped or is damaged on the side surface. Sleeve Wire Loose wire Slightly sticks out Damage Crumpled tip Wire is not inside sleeve

) A cable with a ferrule can be inserted directly into the wire insertion hole. Pull the cable lightly to check that the cable does not come off. (Pushbutton) Wire insertion hole Ferrule When using a stranded wire, insert the wire into the wire insertion hole while holding the pushbutton down with a screwdriver. (2) Removing the cable Remove the wire while holding the pushbutton down to the end with a screwdriver. Pushbutton Wire insertion hole For pressing the pushbutton, use the following recommended tools. Recommended tool (screwdriver) Manufacturer Item number Blade size WO 0-9SB (Mini type) 0-79 2.5 x 0. mm (Insulated shaft type)

-. Attaching/detaching to the DIN rail () Mounting to the DIN rail ) Place the DIN rail mounting groove onto the DIN rail to fit in place. 2) Press the unit slowly toward the DIN rail until the unit clicks in place. [] [2] Press the unit slowly. (2) Removal from the DIN rail ) Insert a flathead screwdriver into the hook on one side and pry the screwdriver to release the claw. Hold the unit with the claw on one side released. 2) Insert the screwdriver into the hook on another side and pry the screwdriver to detach the unit from the DIN rail. [] DIN rail [2] Apply force to the hook to release the claw and hold the unit with the claw on one side released. Apply force to another hook on the other side. 5

7. CONNECTION DIM 7-. Internal connection diagram of 2 2 5 8 7 0 9 2 5 8 7 20 9 22 2 2 0 2 5 8 7 9 2 5 Connector 2 5 7 8 9 0 2 5 78 9 20 22 2 2 0 2 5 78 9 2 5 2 0 2 5 7 8 9 2 5 Terminal block 2 5 7 8 9 0 2 5 7 8 9 20 22 2 Terminal block

7 7-2. Connection diagram of DGSVCB_ Pin No. Pin No. Plate 2 5 7 8 9 0 2 5 7 8 9 20 22 2 2 0 2 5 7 8 9 2 5 2 5 7 8 9 0 2 5 7 8 9 20 22 2 2 0 2 5 7 8 9 2 5 D79-B0FL (junction terminal block side) 0-000EL (servo amplifier side) Shield

8 7-. Connection diagram of DGAFCB_ Pin No. Pin No. Plate 2 5 7 8 9 0 2 5 7 8 9 20 22 2 2 0 2 5 7 8 9 2 5 AO DI0 EMG EMGCOM AI AI AO DI2 DI DI DI8 DIA DO0 DO2 DO DO AI2 AI AO AO DI DI DI5 DI7 DI9 DIB DO DO DO5 DO7 2 5 7 8 9 0 2 5 7 8 9 20 22 2 2 0 2 5 7 8 9 2 5 D79-B0FL (junction terminal block side) 0-000EL (SSCNET III/H analog speed command unit side) Shield

7-. Connector dimensions () Connection unit side Connector Shell kit Manufacturer 0-000EL 0-0-000 M (2) side Socket connector Strain relief Manufacturer D79-B0FL D-79 M 8. EXTERNAL CONNECTION EXAMPLE 8-. Branch of digital interface power supply When this unit is connected with a servo amplifier, up to four digital interface power supplies can be connected. Target servo amplifier: MR-J-_A_(-RJ), MR-J-0A(-RJ), MR-J-_DU_A_(-RJ) () For sink I/O interface 0.2-.5 MADE IN JAPAN MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED 205 7892 5 0.2-.5 MADE IN JAPAN MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED 205 7892 5 0.2-.5 MADE IN JAPAN MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED 205 7892 5 0.2-.5 MADE IN JAPAN MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED 205 7892 5 2 5 7 8 90 2 5 78 9 20 22 2 2 5 7 8 90 2 5 78 9 20 22 2 2 5 7 8 90 2 5 78 9 20 22 2 2 5 7 8 90 2 5 78 9 20 22 2 Up to four digital interface power supplies can be connected. (2) For source I/O interface 0.2-.5 MADE IN JAPAN MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED 205 7892 5 0.2-.5 MADE IN JAPAN MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED 205 7892 5 0.2-.5 MADE IN JAPAN MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED 205 7892 5 0.2-.5 MADE IN JAPAN MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED 205 7892 5 2 5 7 8 90 2 5 78 9 20 22 2 2 5 7 8 90 2 5 78 9 20 22 2 2 5 7 8 90 2 5 78 9 20 22 2 2 5 7 8 90 2 5 78 9 20 22 2 Up to four digital interface power supplies can be connected. 9

8-2. Connection with MR-J-_A_(-RJ), MR-J-0A(-RJ), or MR-J-_DU_A_(-RJ) () Position control mode Differential line driver type ) For sink I/O interface Connection example TLA P5R Upper limit setting Analog torque limit +0 V/max. torque MO MO2 2 LA LAR LB LBR 5 7 Analog monitor * Analog monitor 2 * Encoder A-phase pulse Encoder B-phase pulse Control common OP Encoder Z-phase pulse (open-collector) Control common Positioning module RD75D/LD75D/QD75D CR RD NP NG 5 PP PG LZ LZR 20 0 8 9 2 5 7 8 9 0 CLEARCOM CLEAR RDYCOM READY PULSE F+ PULSE F- PULSE R+ PULSE R- PG0 PG0 COM EM2 LSP LSN LOP 2 5 SON PC TL RES 5 7 8 9 Main circuit power supply Forced stop 2 Servo-on Forward rotation stroke end Proportion control Reverse rotation stroke end External torque limit selection Control switching Reset 2 VDC *2 ALM Malfunction ZSP Zero speed detection INP 2 In-position TLC Limiting torque TRE RDP RDN 9 * P N * 2 VDC *2 2 VDC For the use of multiple axes or branching *: MR-J-0A(-RJ) only *2: The illustration of the 2 VDC power supply is divided for convenience. However, they can be configured by one. *: For actual wiring, be sure to refer to the Servo Amplifier Instruction Manual and Servo Motor Instruction Manual for each product. 0

2) For source I/O interface Connection example TLA P5R Upper limit setting Analog torque limit +0 V/max. torque MO MO2 2 LA LAR LB LBR 5 7 Analog monitor * Analog monitor 2 * Encoder A-phase pulse Encoder B-phase pulse Control common OP Encoder Z-phase pulse (open-collector) Control common Positioning module RD75D/LD75D/QD75D CR RD NP NG 5 PP PG LZ LZR 20 0 8 9 2 5 7 8 9 0 CLEARCOM CLEAR RDYCOM READY PULSE F+ PULSE F- PULSE R+ PULSE R- PG0 PG0 COM EM2 LSP LSN LOP 2 5 SON PC TL RES 5 7 8 9 Main circuit power supply Forced stop 2 Servo-on Forward rotation stroke end Proportion control Reverse rotation stroke end External torque limit selection Control switching Reset 2 VDC *2 ALM Malfunction ZSP Zero speed detection INP 2 In-position TLC Limiting torque TRE RDP RDN 9 * P N * 2 VDC *2 2 VDC For the use of multiple axes or branching *: MR-J-0A(-RJ) only *2: The illustration of the 2 VDC power supply is divided for convenience. However, they can be configured by one. *: For actual wiring, be sure to refer to the Servo Amplifier Instruction Manual and Servo Motor Instruction Manual for each product.

(2) Position control mode Open-collector type ) For sink I/O interface Connection example TLA P5R Upper limit setting Analog torque limit +0 V/max. torque MO MO2 2 LA LAR LB LBR LZ LZR 5 7 8 9 Analog monitor * Analog monitor 2 * Encoder A-phase pulse Encoder B-phase pulse Control common Encoder Z-phase pulse Programmable controller FX5U CPU OP RD NP CR EM2 LSP LSN LOP 5 2 5 PP 0 OPC 2 20 SON 5 PC 7 TL 8 RES 9 Main circuit power supply S/S 2V X 0V X COM0 Y0 COM Y COM2 Y0 Forced stop 2 Servo-on Forward rotation stroke end Proportion control Reverse rotation stroke end External torque limit selection Control switching Reset 2 VDC *2 ALM Malfunction ZSP Zero speed detection INP 2 In-position TLC Limiting torque TRE RDP RDN 9 * P N * 2 VDC *2 2 VDC For the use of multiple axes or branching *: MR-J-0A(-RJ) only *2: The illustration of the 2 VDC power supply is divided for convenience. However, they can be configured by one. *: For actual wiring, be sure to refer to the Servo Amplifier Instruction Manual and Servo Motor Instruction Manual for each product. 2

2) For source I/O interface Connection example TLA P5R Upper limit setting Analog torque limit +0 V/max. torque MO MO2 2 LA LAR LB LBR LZ LZR 5 7 8 9 Analog monitor * Analog monitor 2 * Encoder A-phase pulse Encoder B-phase pulse Control common Encoder Z-phase pulse Programmable controller FX5U CPU OP RD NG CR PP2 NP2 EM2 LSP LSN LOP 7 8 2 5 PG SON PC TL RES 20 5 7 8 9 Main circuit power supply S/S 0V X 2V X +V0 Y0 +V Y +V2 Y0 Forced stop 2 Servo-on Forward rotation stroke end Proportion control Reverse rotation stroke end External torque limit selection Control switching Reset 2 VDC *2 ALM Malfunction ZSP Zero speed detection INP 2 In-position TLC Limiting torque TRE RDP RDN 9 * P N * 2 VDC * 2 VDC For the use of multiple axes or branching *: MR-J-0A(-RJ) only *2: The illustration of the 2 VDC power supply is divided for convenience. However, they can be configured by one. *: For actual wiring, be sure to refer to the Servo Amplifier Instruction Manual and Servo Motor Instruction Manual for each product.

() Speed control mode ) For sink I/O interface Connection example TLA P5R Upper limit setting Analog torque limit +0 V/max. torque P5R VC 2 Upper limit setting Analog speed command ±0 V/rated speed MO MO2 2 0 LA LAR LB LBR 5 7 Analog monitor * Analog monitor 2 * Encoder A-phase pulse Encoder B-phase pulse Control common OP Encoder Z-phase pulse (open-collector) Control common SP Speed selection SON 5 Servo-on Main circuit power supply EM2 2 Forced stop 2 SP2 Speed selection 2 LSP Forward rotation stroke end ST 7 Forward rotation start LSN Reverse rotation stroke end ST2 8 Reverse rotation start LOP 5 Control switching RES 9 Reset 2 VDC *2 ZSP Zero speed detection ALM Malfunction SA 2 Speed reached RD Ready TLC Limiting torque TRE RDP RDN 9 * P N * 2 VDC *2 2 VDC For the use of multiple axes or branching *: MR-J-0A(-RJ) only *2: The illustration of the 2 VDC power supply is divided for convenience. However, they can be configured by one. *: For actual wiring, be sure to refer to the Servo Amplifier Instruction Manual and Servo Motor Instruction Manual for each product.

2) For source I/O interface Connection example TLA P5R Upper limit setting Analog torque limit +0 V/max. torque P5R VC 2 Upper limit setting Analog speed command ±0 V/rated speed MO MO2 2 0 LA LAR LB LBR 5 7 Analog monitor * Analog monitor 2 * Encoder A-phase pulse Encoder B-phase pulse Control common OP Encoder Z-phase pulse (open-collector) Control common SP Speed selection SON 5 Servo-on Main circuit power supply EM2 2 Forced stop 2 SP2 Speed selection 2 LSP Forward rotation stroke end ST 7 Forward rotation start LSN Reverse rotation stroke end ST2 8 Reverse rotation start LOP 5 Control switching RES 9 Reset 2 VDC *2 ZSP Zero speed detection ALM Malfunction SA 2 Speed reached RD Ready TLC Limiting torque TRE RDP RDN 9 * P N * 2 VDC *2 2 VDC For the use of multiple axes or branching *: MR-J-0A(-RJ) only *2: The illustration of the 2 VDC power supply is divided for convenience. However, they can be configured by one. *: For actual wiring, be sure to refer to the Servo Amplifier Instruction Manual and Servo Motor Instruction Manual for each product. 5

() Torque control mode ) For sink I/O interface Connection example TC P5R Upper limit setting Analog torque command ±8 V/max. torque P5R VLA 2 Upper limit setting Analog speed limit 0 to ±0 V/rated speed MO MO2 2 0 LA LAR LB LBR 5 7 Analog monitor * Analog monitor 2 * Encoder A-phase pulse Encoder B-phase pulse Control common OP Encoder Z-phase pulse (open-collector) Control common SP Speed selection SON 5 Servo-on Main circuit power supply EM2 LOP 2 5 SP2 RS2 RS RES 7 8 9 Forced stop 2 Speed selection 2 Reverse rotation selection Forward rotation selection Control switching Reset 2 VDC *2 ZSP Zero speed detection ALM Malfunction RD Ready VLC Limiting speed TRE RDP RDN 9 * P N * 2 VDC *2 2 VDC For the use of multiple axes or branching *: MR-J-0A(-RJ) only *2: The illustration of the 2 VDC power supply is divided for convenience. However, they can be configured by one. *: For actual wiring, be sure to refer to the Servo Amplifier Instruction Manual and Servo Motor Instruction Manual for each product.

2) For source I/O interface Connection example TC P5R Upper limit setting Analog torque command ±8 V/max. torque P5R VLA 2 Upper limit setting Analog speed limit 0 to ±0 V/rated speed MO MO2 2 0 LA LAR LB LBR 5 7 Analog monitor * Analog monitor 2 * Encoder A-phase pulse Encoder B-phase pulse Control common OP Encoder Z-phase pulse (open-collector) Control common SP Speed selection SON 5 Servo-on Main circuit power supply EM2 LOP 2 5 SP2 RS2 RS RES 7 8 9 Forced stop 2 Speed selection 2 Reverse rotation selection Forward rotation selection Control switching Reset 2 VDC *2 ZSP Zero speed detection ALM Malfunction RD Ready VLC Limiting speed TRE RDP RDN 9 * P N * 2 VDC *2 2 VDC For the use of multiple axes or branching *: MR-J-0A(-RJ) only *2: The illustration of the 2 VDC power supply is divided for convenience. However, they can be configured by one. *: For actual wiring, be sure to refer to the Servo Amplifier Instruction Manual and Servo Motor Instruction Manual for each product. 7

8-. Connection with MR-D0 () Point table method ) For sink I/O interface Connection example RES TL TL TP0 TP OVR MD0 TSTP PC ST ST2 2 0 2 5 7 DI0 DI 2 DI2 DI DI 5 DI5 DI 7 DI7 8 SON D 2 VDC * 2 VDC * Point table No. selection Reset External torque limit selection Point table No. selection 2 Internal torque limit selection Point table No. selection Manual pulse generator multiplication Manual pulse generator multiplication Point table No. selection Override selection Point table No. selection 5 Operation mode selection Point table No. selection Temporary stop/restart Point table No. selection 7 Proportion control Point table No. selection 8 Forward rotation start Reverse rotation start Servo-on MCD00 8 M code (bit 0) MCD0 9 M code 2 (bit ) MCD02 M code (bit 2) MCD0 M code (bit ) MCD0 2 M code 5 (bit ) MCD M code (bit 5) MCD2 M code 7 (bit ) MCD 5 M code 8 (bit 7) PUS During a temporary stop MEND Travel completion ACD0 22 Alarm code 0 ACD Alarm code CP0 Rough match ACD2 2 Alarm code 2 INP In-position MEND MEND *2 ACD SON SON *2 Alarm code *: The illustration of the 2 VDC power supply is divided for convenience. However, they can be configured by one. *2: When MR-D0 is used, the branch connection of the digital interface power supply is not available. *: For actual wiring, be sure to refer to the Servo Amplifier Instruction Manual and Servo Motor Instruction Manual for each product. 8

2) For source I/O interface Connection example RES TL TL TP0 TP OVR MD0 TSTP PC ST ST2 2 0 2 5 7 DI0 DI DI2 DI DI DI5 DI DI7 SON D 2 5 7 8 2 VDC * 2 VDC * Point table No. selection Reset External torque limit selection Point table No. selection 2 Internal torque limit selection Point table No. selection Manual pulse generator multiplication Manual pulse generator multiplication Point table No. selection Override selection Point table No. selection 5 Operation mode selection Point table No. selection Temporary stop/restart Point table No. selection 7 Proportion control Point table No. selection 8 Forward rotation start Reverse rotation start Servo-on MCD00 8 M code (bit 0) MCD0 9 M code 2 (bit ) MCD02 M code (bit 2) MCD0 M code (bit ) MCD0 2 M code 5 (bit ) MCD M code (bit 5) MCD2 M code 7 (bit ) MCD 5 M code 8 (bit 7) PUS During a temporary stop MEND Travel completion ACD0 22 Alarm code 0 ACD Alarm code CP0 Rough match ACD2 2 Alarm code 2 INP In-position MEND MEND *2 ACD SON SON *2 Alarm code *: The illustration of the 2 VDC power supply is divided for convenience. However, they can be configured by one. *2: When MR-D0 is used, the branch connection of the digital interface power supply is not available. *: For actual wiring, be sure to refer to the Servo Amplifier Instruction Manual and Servo Motor Instruction Manual for each product. 9

8-. Connection with DG2AF/DG2AF-P0 ) For sink I/O interface Connection example AI2 AI AI 2 Analog input AI AO2 2 AO AO 7 8 Analog output 5 AO 9 DI DI DI5 DI7 DI9 DIB 7 8 9 2 DI0 DI2 DI DI DI8 DIA EMG 2 5 7 9 Emergency stop Digital input 2 VDC EMGCOM DO 8 DO DO0 DO2 DO 22 Digital output DO5 DO 2 DO7 DO DO DO0 * DO0 * *: When the SSCNET III/H analog speed command unit is used, branch connection of the digital interface power supply is not available. *2: For actual wiring, be sure to refer to the User's Manual (Hardware) and User's Manual (Detailed) for each product. 20

2) For source I/O interface Connection example AI2 AI AI 2 Analog input AI AO2 2 AO AO 7 8 Analog output 5 AO 9 DI DI DI5 DI7 DI9 DIB 7 8 9 2 DI0 DI2 DI DI DI8 DIA EMG 2 5 7 9 Emergency stop Digital input 2 VDC EMGCOM DO 8 DO DO0 DO2 DO 22 Digital output DO5 DO 2 DO7 DO DO * DO0 DO0 * *: When the SSCNET III/H analog speed command unit is used, branch connection of the digital interface power supply is not available. *2: For actual wiring, be sure to refer to the User's Manual (Hardware) and User's Manual (Detailed) for each product.

9. APPLICABLE CRIMPING TERMINAL Manufacturer WO Type Applicable wire size 0.08 to 0. mm 2 /(AWG to AWG22) 0. mm 2 /AWG2 and AWG22 0.5 mm 2 /AWG22 and AWG20 0.75 mm 2 /AWG20 and AWG8 Applicable ferrule terminal Crimping tool -02 20-220 -02-20 20-20 -202 22

Ferrule dimensions () Dimensions before crimping Dimensions [Unit: mm] Insulating collar Conductive area (2) Dimensions after crimping ) When the crimping tool 20-20 is used Dimensions * Insulating collar Conductive area 2) When the crimping tool 20-220 is used Insulating collar Conductive area *: The dimensions must not be smaller than 0. mm 2. *2: The solid wire and stranded wire used are the UL-certified products. Shape of terminal block [Unit: mm]

[Warranty]. Warranty period and coverage If any failure or defect hereinafter referred to as "failure" in our FA equipment hereinafter referred to as the "Product" has arisen during warranty period due to causes for which we are responsible, we will offer a substitute for the defective Product at no charge in exchange for the Product through the distributor from which you purchased the Product. We are not responsible for any on-site readjustment and/or trial run that may be required after a defective unit are repaired or replaced. [Term] The term of warranty for Product is twelve (2) months after your purchase or delivery of the Product to a place designated by you or eighteen (8) months from the date of manufacture whichever comes first ("Warranty Period"). Warranty period for repaired Product cannot exceed beyond the original warranty period before any repair work. [Limitations] () This limited warranty applies only when the condition, method, environment, etc. of use are in compliance with the terms and conditions and instructions that are set forth in the instruction manual and User s Manual for the Product. (2) Even during the term of warranty, the replacement cost will be charged on you in the following cases; (i)via failure caused by your improper storing or handling, carelessness or negligence, etc., and a failure caused by your hardware or software problem (ii)va failure caused by any alteration, etc. to the Product made on your side without our approval (iii) a failure recognized as avoidable if your equipment in which the Product is incorporated is equipped with a safety device required by applicable laws, or has any function or structure considered to be indispensable according to a common sense in the industry (iv) Failure recognized as preventable if consumable products specified in the instruction manual, etc. were normally maintained and replaced. (v)iiany replacement of consumable parts (relays, etc.) (vi)ia failure caused by external factors such as inevitable accidents, including without limitation fire and abnormal fluctuation of voltage, and acts of God, including without limitation earthquake, lightning and natural disasters (vii) a failure generated by an unforeseeable cause with a scientific technology that was not available at the time of the shipment of the Product from our company (viii) any other failures which we are not responsible for or which you acknowledge we are not responsible for 2. Term of warranty after the stop of production () We may accept the repair at charge for another seven (7) years after the production of the Product is discontinued. The announcement of the stop of production for each model can be seen in our website MEEFAN. (URL: http://www.mee.co.jp/sales/fa/meefan/) (2) Please note that the Product (including its spare parts) cannot be ordered after its stop of production.. Service in overseas countries Service in overseas countries is out of the warranty.. Exclusion of loss in opportunity and secondary loss from warranty liability Regardless of the gratis warranty term, Mitsubishi Electric Engineering shall not be liable for compensation to: damages caused by any cause found not to be the responsibility of Mitsubishi Electric Engineering, loss in opportunity and lost profits incurred to the user by failures of Mitsubishi Electric Engineering products, special damages and secondary damages whether foreseeable or not, compensation for accidents, compensation for damages to products other than Mitsubishi Electric Engineering products, replacement by the user, maintenance of on-site equipment, start-up test run, and other tasks. 5. Change of Product specifications Specifications listed in our catalogs, manuals or technical documents may be changed without notice. 2

. Conditions of use for the Product () For the use of this Product, its applications should be those that may not result in a serious damage even if any failure or malfunction occurs in the equipment, and a backup or fail-safe function should operate on an external system to the equipment when any failure or malfunction occurs. (2) This Product is designed and manufactured as a general purpose product for use at general industries. Therefore, applications substantially influential on the public interest for such as atomic power plants and other power plants of electric power companies, and also which require a special quality assurance system, including applications for railway companies and government or public offices are not recommended, and we assume no responsibility for any failure caused by these applications when used. In addition, applications which may be substantially influential to human lives or properties for such as airlines, medical treatments, railway service, incineration and fuel systems, man-operated material handling equipment, entertainment machines, etc. are not recommended, and we assume no responsibility for any failure caused by these applications when used. Note that if the user consults with Mitsubishi Electric Engineering customer service in advance with regard to such an application and the user accepts that the application is to be limited and a special quality is not to be required, application shall be made possible upon exchange of required documents.

--5, Kudankita, Chiyoda-ku, Tokyo, 02-007, Japan URL:http://www.mee.co.jp/ EN-0708-A Specifications are subject to change without notice. New publication, APR. 207