Inteplast Trim Free Foam

Similar documents
SECTION PLASTIC FABRICATIONS PART I GENERAL 1.01 SECTION INCLUDES

SECTION SIMULATED WOOD TRIM. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION Plastic Simulated Wood Trim SIMULATED WOOD TRIM PART 1 GENERAL 1.1 SECTION INCLUDES

Endura-Classic Craftsman Information

Make every component count.

AZEK Trim & Moulding Install Guide

Exterior Moulding & Trim Special Order Items. royalbuildingproducts.com Royal Building Products

A. ASTM D Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.

SECTION SIMULATED WOOD TRIM

Canadian Product Spec Guide

Product Guide Specification

A. Columns: Worthington Millwork; Cellular Polyvinyl Chloride (PVC) columns; decorative, weatherproof, insect-proof, and highly durable.

A. All trim that has been damages, broken, or missing shall be repaired or replaced with material of the same size, shape, and type.

VERSAROC CEMENT BONDED PARTICLE BOARD ROOF SHEATHING VERSAROC CEMENT BONDED PARTICLE BOARD ROOF SHEATHING

Tools required by installer: Materials required by installer:

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS

INSTALLATION. PALIGHT Trimboard Free Foam Cellular PVC for Trim and Moulding Applications.

COMPOSITE SIDING INSTALLATION GUIDE

SECTION FINISH CARPENTRY PART 1 GENERAL. 1.1 SECTION INCLUDES A. Interior Finish Carpentry Work: 1. Refer to schedule at end of Section.

You expect to find PVC. PVC Lumber PROS & CONS OF PVC PROS

1.04 QUALITY ASSURANCE

Product Guide Specification

MAXISHINGLE LAP SIDING INSTALLATION GUIDE

SECTION MANUFACTURED CASEWORK

DYNEX SOFFIT SYSTEM. Product. Scope. Building Regulations. Appraisal No. 908 [2016] Appraisal No. 908 (2016) BRANZ Appraisals

Ash Brook Golf Course Scotch Plains, New Jersey

Shapes Siding. Perfection Shingles. Chalk Line

2016 Specification Treads, Base, Stringers and other Amenities Wausau Tile Precast Epoxy Terrazzo

Installation Instructions

Trim and Moulding. Product Spec Guide

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

4256HM JAMES HARDIE MONOLITHIC CLADDING

Lumicor CSI Specification Guide Open Format Section Solid Polymer Fabrication

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

Installation Guide. Replacing Wood For Good

1. Section : Rough Carpentry 2. Section : Exterior Insulation and Finishing Systems 3. Section : Metal Roof Panels

Slate Shingle Specifications

eco-shake INSTALLATION INSTRUCTION

PANELTEK ENGINEERED SIDING/PANELLING INSTRUCTIONS

Student Services & Classroom Addition

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

INTEX Millwork Solutions SECTION EXTERIOR PVC PERGOLAS (IBC Compliant)

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

PVC Column Wraps - Semi-Assembled INSTALLATION INSTRUCTIONS

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

Series 9000 Vinyl Fixed Window

LuxCore Installation Instructions

FABRICATION MANUAL CCM Copper Composite You discover why ALPOLIC Copper composite material (CCM) is the building material of the future as soon as

Series 9000 Vinyl Fixed Window

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

Vinyl Windows Manufactured by VPI Quality Windows

STACKING MULTI-SLIDE DOOR SYSTEM

Installation Manual for Thermo Panel

SECTION ARCHITECTURAL WOODWORK

SECTION LAP SIDING. A. Fiber cement lap siding, panels, single, trim, fascia, moulding and accessories.

pacific build supply ltd

Installation Guide. Pionite Decorative Surfaces One Pionite Road, Auburn, Maine PIONITE ( )

Ignitability Index Spread of Flame Index Heat Evolved Index Smoke Developed Index. Range 0-20 Range 0-10 Range 0-10 Range

PALIGHT Trimboard Foam PVC for Trim and Molding Applications.

Series 9000 Vinyl Single Hung

INSTALLATION INSTRUCTIONS

Beams INSTALLATION INSTRUCTIONS

SECTION CARPENTRY

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

SECTION ARCHITECTURAL WOOD CASEWORK

Installation Guidelines EX-Cel & NuCedar PVC Trim, Sheet & Moulding

SECTION SLATE SHINGLES. 1.1 SUMMARY A. Section Includes: 1. Slate shingles over underlayment nailed to roof sheathing.

B. Related Sections: The following Sections contain requirements that relate to this Section:

ENDUREED VIVA SERIES Specifications

Series 6000 Vinyl Single Hung

AZEK Porch Install Guide

GREEN WORLD LUMBER GENUINE MAHOGANY DECKING INSTALLATION GUIDE

RESIDENTIAL ROOFS ADDENDUM NUMBER ONE. August 28, 2017

MULTISHAKE LAP SIDING INSTALLATION GUIDE STORAGE AND HANDLING: PACKAGING:

Technical Note No. 028

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

STEEL FRAMING WEATHERBOARD SYSTEM

SECTION BULLET- RESISTANT DOORS

3400 Tectura Designs Precast Concrete

INSTALLATION INSTRUCTIONS MILLENNIUM DECKING Before Installing Millennium Decking, please read these instructions in their entirety.

DIVISION 6 WOOD AND PLASTICS

Installation Guide. Shingles. Classical. Shingles. Warning. Storage. Cutting Shingles. Touch-Up. Eastern White Cedar

THE PERFORMANCE LEADER IN EXTERIOR LIVING SPACE

PRIMED STRAND REVERSIBLE SHAKE

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM

Series 9000 Vinyl Horizontal Slider

Series 6000 Vinyl Horizontal Slider

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)

B. Terracotta Precast Facade Assembly consisting of single-leaf, through body color terracotta clay tiles.

PURE. Exterior PVC Millwork Catalog. Preparation UV Protection Realistic Look Extruded by Gossen EXTERIOR PVC MILLWORK

FT DIX ELEMENTARY SCHOOL PHASE VII, CLASSROOM ADDITION PEMBERTON TOWNSHIP REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5349A

Stone coated steel roof tile INSTALLATION GUIDE

Natural Wood Siding. Installation Procedures

NATURA PRO Product Information Leaflet 1

March High performance building boards

LP SmartSide Soffit ON SITE STORAGE PREPARATION. Application Instructions Vented and Non-Vented Smooth Finish or Cedar Texture. General Information

Application Instructions

How To Install Windows: Nail-Fin Application

Transcription:

Inteplast Trim Free Foam SECTION 06 60 00 PLASTIC FABRICATIONS PART 1 GENERAL 1.01 SECTION INCLUDES A. Inteplast Trim Free Foam cellular PVC boards used for corner boards, soffits, fascias, battens, door pilasters, frieze boards, rake boards, architectural millwork and door/window trim. 1.02 RELATED SECTIONS A. Section 06 64 00 - Plastic Paneling. B. Section 06 65 00 - Plastic Simulated Wood Trim. C. Section 06 66 00 - Custom Ornamental Simulated Woodwork. 1.03 REFERENCES A. AATC 127-1985 Hydrostatic Head Leakage Test. B. ASTM C177 Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus. C. ASTM D256 Standard Test Methods for Determining the Izod Pendulum Impact Resistance of Plastics. D. ASTM D570 Standard Test Method for Water Absorption of Plastics. E. ASTM D635 Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position. F. ASTM D648 Standard Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position. G. ASTM D696 Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between 30 C and 30 C with a Vitreous Silica Dilatometer. H. ASTM D790 Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials. I. ASTM D792 Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement J. ASTM D1761 Standard Test Methods for Mechanical Fasteners in Wood. K. ASTM D3345 Standard Test Method for Laboratory Evaluation of Wood and Other Cellulosic Materials for Resistance to Termites. L. ASTM D5420 Standard Test Method for Impact Resistance of Flat, Rigid Plastic Specimen by Means of a Striker Impacted by a Falling Weight (Gardner Impact). M. ASTM D6662 Standard Specification for Polyolefin-Based Plastic Lumber Decking Boards. N. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials. O. ASTM E330 Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference. P. ASTM G155 Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials. Q. AWPA E12 Corrosion of Materials on Contact with Treated Wood.

1.04 SUBMITTALS A. General: Submit listed submittals in accordance with Conditions of the Contract and Division 1 Submittal Procedures Section. B. Product Data: Submit product data, manufacture s catalog, technical bulletins, for specified products. C. Samples: Submit three material samples representative of the texture, thickness and widths shown andspecified herein. 1.05 QUALITY ASSURANCE A. Regulatory Requirements: Check with Local Building Code for installation requirements. B. Allowable Tolerances: 1. Variation in component length: -0.0 / +7/8 2. Variation in component width: -0.0 / +1/16 3. Variation in component thickness: ± 5% 4. Variation in component edge cut: ± 2 5. Variation in Density: ± 5% C. Workmanship, Finish, and Appearance: 1. Inteplast Trim Free Foam cellular PVC board is homogeneous and free of voids, holes, cracks, and foreign inclusions and other defects. Edges must be square, and top and bottom surfaces shall be flat with no convex or concave deviation. 2. Uniform surface free from cupping, warping, and twisting. 1.06 DELIVERY, STORAGE AND HANDLING A. Trim materials should be stored on a flat and level surface on a full shipping pallet. Handle materials to prevent damage to product edges and corners. Store materials under a protective covering to prevent job site dirt and residue from collecting on the boards. 1.07 WARRANTY A. Inteplast Trim is backed by a lifetime limited warranty for single-family residential purchases and applications against rot, delaminate, splinter, crack, split, excessively swell, or suffer structural damage from termites or fungal decay. For all other purchases and applications, including commercial use, condominiums and multi-family dwellings, this warranty shall be limited to a period of twenty (20) years. PART II PRODUCTS 2.01 MATERIALS A. Acceptable products: Inteplast Trim Free Foam manufactured by Inteplast Group Ltd., 101 Inteplast Blvd., Lolita, TX 77971. B. Material: Free foam cellular PVC material with a small-cell microstructure and density of 0.57 grams/cm3. 1. Material shall have typical physical and performance properties specified in Section C on the following page.

C. Performance and physical characteristic requirements: Property Test Method Value Density, g/cm3 ASTM D792 0.60 MOR (Flexural Strength), psi ASTM D790 3,600 MOE (Flexural Modulus), psi ASTM D790 144,000 Weathering ASTM G155 & MOR (Change), % ASTM D790 +2.4 MOE (Change), % +0.7 Freeze-Thaw ASTM D6662 & MOR (Change), % ASTM D790 +0.1 MOE (Change), % +0.9 Water Resistance AATCC 127 No Penetration Water Absorption, 24 hrs, % ASTM D570 < 0.3 Termite Resistance ASTM D3345 9.2 Surface Burning, Flame Spread Index ASTM E84 25.0 Burning Rate ASTM D635 No burn when flame removed Mechanical Fastener, Allowable Load, lbf ASTM D1761 151 (8d nail and 1" thick trim) Negative Transverse Wind Load, psf ASTM E330 72.0 Gardener Impact Resistance, in-lbf ASTM D5420 629 (3/4" thick trim) Coefficient of Linear Thermal Expansion, o C -1 ASTM D696 6.27 E-5 Heat Deflection Temp., o F @ 264 psi ASTM D648 146 Corrosion by Preservative-Treated Wood AWAP E12 No Wt. Loss Izod, ft-lb/in ASTM D256 0.37 Heat Conductivity, Btu-in/hr-ft2- o F ASTM C177 0.5 2.02 ACCESSORY PRODUCTS A. Fasteners: 1. Use fasteners designed for wood trim and wood siding (thinner shank, blunt point, full round head) with Inteplast Trim Free Foam. 2. Use a highly durable fastener such as stainless steel or hot-dipped galvanized. 3. Staples, small brads and wire nails must not be used as fastening members. 4. The fasteners should be long enough to penetrate the solid wood substrate a minimum of 1-3/8. 5. Standard nail guns work well with Inteplast Trim Free Foam. 6. Use 2 fasteners per every framing member for trim boards applications. Trim boards of 12 or wider, as well as sheets, will require additional fasteners. 7. Fasteners must be installed no more than 2 from the end of each board. 8. Inteplast Trim Free Foam should be fastened into a flat, solid substrate. Fastening Inteplast Trim Free Foam into hollow or uneven areas must be avoided. 9. Pre-drilling is typically not required unless a large fastener is used or product is installed in low temperatures. 10. 3/8 and 1/2 sheet product is not intended to be ripped into trim pieces. These profiles must be glued to a substrate and mechanically fastened. B. Adhesives:

1. Glue all joints between Inteplast Trim Free Foam such as window surrounds, long fascia runs, etc. with cellular PVC cement, to prevent joint separation. 2. The glue joint should be secured with a fastener and/or fastened on each side of the joint to allow adequate bonding time. 3. Surfaces to be glued should be smooth, clean and in complete contact with each other. 4. To bond Inteplast Trim Free Foam to other substrates, various adhesives may be used. Consult adhesive manufacturer to determine suitability. C. Sealant: 1. Use urethane, polyurethane or acrylic based sealant without silicone. 2.03 FINISHES A. Inteplast Trim Free Foam do not require paint for protection, but may be painted to achieve a custom color. B. Preparation: 1. No special surface preparation is required prior to painting - sanding is not necessary for paint adhesion. 2. Surface must be clean and dry. 3. If desired, nail holes may be filled with polyurethane or acrylic based caulk. 4. Use a 100% acrylic latex paint with a Light Reflective Value (LRV) of 54 or higher. 5. Follow the paint manufacturer s recommendations to apply. PART III EXECUTION 3.01 INSTALLATION A. Manufacturers instructions: 1. Comply with manufacturer s product catalog installation instructions and product technical bulletin instructions. B. Cutting: 1. Inteplast Trim Free Foam can be cut using the same tools used to cut lumber. 2. Carbide tipped blades designed to cut woodwork well. Avoid fine tooth metal cutting blades. 3. Rough edges from cutting may be caused by excessive friction, poor board support, or worn or improper tooling. C. Drilling: 1. Inteplast Trim Free Foam can be drilled using the same tools used to drill lumber. 2. Drilling Inteplast Trim Free Foam is similar to drilling a hardwood. Care should be taken to avoid frictional heat buildup. 3. Use standard woodworking drills. Do not use drills made for normal rigid PVC. 4. Periodic removal of Inteplast Trim Free Foam shavings from the drill hole may be necessary. D. Milling:

1. Inteplast Trim Free Foam can be milled using standard milling machines used to mill lumber. 2. Relief Angle 20 to 30. 3. Cutting speed to be optimized with the number of knives and feed rate. E. Routing: 1. Inteplast Trim Free Foam can be routed using standard router bits and the same tools used to rout lumber. 2. Carbide tipped router bits are recommended. F. Edge Finishing: 1. Edges can be finished by sanding, grinding or filing with traditional woodworking tools. G. Nail Location: 1. Use 2 fasteners per every framing member for trim board applications. 2. Inteplast Trim Free Foam of over 12 or wider, as well as sheets, will require additional fasteners. 3. Fasteners must be installed no more than 2 from the end of each board. H. Thermal Expansion and Contraction: 1. Inteplast Trim Free Foam expands and contracts with changes in temperature. 2. Properly fastening Inteplast Trim Free Foam along its entire length will minimize expansion and contraction. 3. When properly fastened, allow for 1/8 per 18 foot of Inteplast Trim Free Foam for expansion and contraction. 4. Joints between pieces of Inteplast Trim Free Foam should be glued to eliminate joint separation. 5. Allow expansion and contraction space at the ends of long runs. END OF SECTION