Programmable Digital Timer

Similar documents
Programmable Digital Timer

PROGRAMMABLE DIGITAL TIMER ELIRO (33 Functions): V7DFTS3

Timers. Products and specifications subject to change without notice.

Multi-function 11 pin Plug-in for use with 90 series sockets

87 Series - Modular timers 5-8 A. Features

VAC V AC/DC, +/-10%, 45-65Hz Hz VDC max 1W ; 24VAC 2.5VA, 48VAC 4.46VA ; 110VAC 1.76 VA ; 220VAC 2.53 VA

Chronos 2 electronic timers mm

Timing Mode Supply Voltage Trigger Options Reset Options Outputs Cat. No V AC Power On Power Off. Repeat Cycle OFF-Start

Chronos 2 electronic timers - Plug-in 8-pin (35 mm)

17.5mm Chronos 2 Timers

Electronic timers CT-S range Selection and ordering details

05/09/2012

Type Nominal voltage (V) Code HSV V

02/11/2015

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Output C urrent E ffic ienc y (1)

RENF22R2MMW Zelio Timer Relay - Modular

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Section. Timers. Selection Guide... G-2. Timing Diagrams Overview... G-4. W G RTE Series Analog Timers... G-8 Accessories... G-11 Dimensions...

Electronic timer CT-MFS.21

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Multi-function 11 pin Plug-in for use with 90 series sockets

02/11/2015

Technical Data Sheet. x1000. kwh R Y B

02/11/2015

Pulse Scaler for DIN Rail Attachment

Control Relays and Timers

Solid-state Timer H3DS

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

83 Series - Modular timers 16 A. Features

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

08/07/2015

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

08/07/2015

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17LLBM asymmetrical flashing relay s V AC - solid state output

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Bulletin 700-HX Multifunction Digital Timing Relay

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

PART NUMBERING SYSTEM

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

PIR6WT-1Z interface - time relays

Multifunction Devices CIM1, CIM12, CIM13, CIM14

Solid-state Timer H3DE

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

22/10/2012

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Multi-voltage Multi-function. Wiring diagram (without control signal)

W a tts A H M S e r ie s A C D C. S p e c if ic a tio n. G e n e r a l. In p u t. E n v ir o n m e n ta l. E M C & S a f e ty.

Digital Multifunction Instrument - Rish Master 3440

PART NUMBERING SYSTEM

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

Switching & Controls Timers

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Solid-state Twin Timer

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Complete units: Mushroom heads ø 22mm

Type CP-S, CP-C & CP-A Switch mode

Electronic relays. Monitoring. Monitoring

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

38 Series - Relay interface modules A

Control Stations ø 22

38 Series - Relay interface modules A

27/04/2015

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

SMARTimer, digital timer 16 A

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

Electronic timer CT-TGD.22

Output Voltage* (nom.)(adjustable)


VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

E-STOP relays, safety gate monitors

Solid-state Timer H3DS

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Operator Heads: ø 22mm

83 SERIES. 83 Series - Modular timers A. Features

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

Complete units: Selector switches ø 22mm

Transcription:

Programmable Digital imer Digital 7-egment display upply Voltage range of 110-240 VAC Input ignal ensing range of 85-265 VAC/100-265 VDC & 20-60 VAC/DC Inbuilt library of 33 functions covering majority applications Easy steps to program customized functions uitable for Panel and Base/DIN mounting wo separate Channel outputs with selectable imer modes Wide timing range - 0.1 ec. to 999 Days amper proof with key lock feature Provision to edit Preset time during un time Provision to save two independent functional Profiles (P1 & P2) Ordering Information Cat. No. V7DF3 V7DD3 Description 110-240 VAC, Multi Function Digital imer - Eliro (33 Functions), 2 C/O 110-240 VAC, Multi Function Digital imer - Eliro (33 Functions), 2 C/O, 11 Pin Universal socket 10

Programmable Digital imer Cat. No. Parameters imer Description Default Functions EMI / EMC Harmonic Current Emissions IEC 61000-3-2 ED IEC 61000-4-2 adiated usceptibility IEC 61000-4-3 Electrical Fast ransients IEC 61000-4-4 urges IEC 61000-4-5 Conducted usceptibility IEC 61000-4-6 Voltage Dips & Interruptions (AC) IEC 61000-4-11 Voltage Dips & Interruptions (DC) IEC 61000-4-29 Conducted Emission CIP 14-1 adiated Emission CIP 14-1 Environmental Cold Heat IEC 60068-2-1 Dry Heat IEC 60068-2-2 Vibration IEC 60068-2-6 epetitive hock IEC 60068-2-27 Non-epetitive hock IEC 60068-2-27 V7DF3 1) On delay 2) On delay constant supply type 2 3) On delay constant supply type 3 4) On delay (control switch resettable) 5) ignal on delay 6) Inverted signal on delay 7) Inverted signal on delay type 2 8) ignal off delay 9) Off delay const. supply type 2 10) Cyclic on/off 11) Cyclic off/on 12) Asymmetric cycle pulse start 13) Asymmetric recycler pulse start type 2 14) ignal on off delay 15) ignal on off delay type 2 16) ignal off/on (new) Programmable Multi Function Digital imer upply Voltage ( ) upply Variation 110-240 VAC -20% to +10% (of ) Frequency Power Consumption (Max.) iming ange 47-63 Hz 9 VA 0.1s to 999 days eset ime/initiate ime 200 ms (Max.) / 100 ms (Max.) Input ignals/ignal Isolation High ange: 85-265V AC/ 100-265V DC, Low ange: 24-60V AC/DC / 2 KV ignal ensing ime/ Wait Period 50ms. (max.) / 100ms @ Power On & for signal based modes only. iming Accuracy ± 0.01% elay Output 2 C/O Output Contact ating 5A for NO & 3A for NC @ 250VAC/30VDC (esistive.) 5 Electrical Life 1x10 6 Mechanical Life 5x10 Utilization Category AC - 15 250V AC/2A, Cos Ø = 0.6, 85ºc, 100000 Operations. DC - 13 Ue rated voltage V 24; Ie rated current A 2.0. Operating emperature torage emperature -5 C t o + 55 C -10 C t o + 60 C Humidity (Non Condensing) 95% (h) LED Indication V (ed) - et Value; P1/P2 (ed) -P1 unning; Up/Down (ed)-up Counting; G (Green)- ignal Present;OP1 (ed)-elay OP1 ON;OP2 (ed)-elay OP2 ON; Enclosure IP 30 for Housing & front Facia l and IP 20 for erminals Dimension (W x H x D) (in mm) 48 X 48 X 92.5 Weight (unpacked) 160 g Mounting Panel / Flush Mountable Base / DIN ail with 11 Pin Universal socket Certification oh Compliant Degree of Protection IP 20 for erminal s, IP 30 for Enclosure 11 V7DD3 17) Impulse on energizing 18) Impulse on/off 19) Accumulative delay on signal 20) Accumulative delay on inverted signal 21) Accumulative impulse on signal 22) Leading edge impulse 23) Leading edge impulse 2 24) railing edge impulse 25) railing edge impulse 2 26) Delayed impulse 27) Delayed impulse type 2 28) Delayed pulse (constant supply) 29) Delayed pulse (remote trig.) 30) Delayed pulse (const. supply type 1) 31) On pulse (control switch resettable) 32) On pulse (supply reset)mode 33) Leading edge bi-stable or step relay

Programmable Digital imer FUNCIONAL DIAGAM : upply Voltage, : Input ignal, : elay Output : Preset ime, ON: Preset ON ime, OFF: Preset OFF ime, -a: iming Break Before completion ON DELAY [00] time duration () starts. On completion of the preset time, the output is switched ON and remains ON till the supply voltage is IGNAL OFF DELAY [07] On application of supply voltage and input signal, the output is switched ON. When the signal is removed the preset time duration commences & the output is switched OFF at the end of the time duration. ON DELAY CONAN UPPLY YPE 2 [01] iming will commence when the supply is present and input signal is not applied. After the time period has elapsed, output is switched ON. If signal is applied then the timing period stops. iming will restart only when signal is removed. herefore there are two methods this timer can be controlled, either by application or removal of signal input and with the interruption of the supply voltage to the timer with signal removal. iming topped OFF DELAY CON. UPPLY YPE 2 [08] A permanent supply is required. When the input signal is applied the output is switched ON immediately. When input signal is removed the timing period starts. After the time period has elapsed output is switched OFF. Once the timing period has started further actions of input signal will have no effect. However once the timing cycle has been completed the process may be started again applying input signal. While the timer is executing the only way to reset the timer is to interrupt the supply. ON DELAY CONAN UPPLY YPE 3 [02] A permanent supply is required. he timing period starts when the signal is applied and will continue irrespective of any further changes to signal input. After the time period has elapsed output is switched ON. ignal change has no effect during timing period. o reset the timer, signal must be removed and then applied. CYCLIC ON/OFF {ON start, (ym, Asym)} [09] On application of supply voltage, the ON OFF ON OFF output is initially switched ON for the preset ON time duration (ON) after which it is switched OFF for the preset OFF time duration (OFF). his cycle repeats and continues till the supply is ON DELAY (CONOL WICH EEABLE) [03] When the supply is connected and signal is applied, the timing function starts. If signal is removed and applied during the preset timing then timing is restarted and output stays OFF. After preset time has elapsed the output is ON. CYCLIC OFF/ON {OFF tart, (ym, Asym)} [10] On application of supply voltage, the output is initially switched OFF for the OFF ON OFF ON iming eloaded preset OFF time duration (OFF) after which it is switched ON for the preset ON time duration (ON). his cycle repeats and continues till the supply is IGNAL ON DELAY [04] time duration () starts. On completion of the preset time, the output is switched ON and remains ON till the input signal is AYMMEIC CYCLE PULE A [11] A permanent supply is required. he timer function is triggered by the input signal. When input signal applied the output is switched ON while the first preset time period (ON) elapses. Once this time period (ON) has elapsed output is switched OFF for the second preset time (OFF) period. Once this second time period (OFF) had elapsed then output switched ON and the cycle will start from the beginning again. If input signal is removed during timing (ON or OFF) the cycle will stop and output is switched OFF, cycle will start with output ON state when the input signal applied again ON OFF ON OFF ON ON OFF iming topped INVEED IGNAL ON DELAY [05] time duration () starts. When input signal is applied, the timing pauses & resumes only when the signal is removed. On completion of the preset time, the output is switched ON. AYMMEEIC ECYCLE PULE A YPE 2 [12] A permanent supply is required. he timer function is triggered by input signal. When input signal is applied the output is switched OFF while the first preset time period (OFF) elapses. Once this time period has elapsed output is switched ON for the second preset time period (ON). Once this second time period (ON) had elapsed then output is switched OFF and the cycle will start from the beginning again. If input signal is removed during timing (ON or OFF) the cycle will stop and output is switched OFF, cycle will start with output OFF state when the input signal applied again. OFF ON OFF OFF ON OFF ON iming topped INVEED IGNAL ON DELAY-YPE 2 [06] iming starts only upon signal transition high to low. During timing or after completion of ime (i.e. relay on), any signal transition is ignored. o reset the timer supply has to be interrupted. IGNAL ON OFF DELAY [13] On application of signal the preset time () starts. After this preset time has elapsed, output is switched ON. During this timing, if signal is removed then output is switched ON immediately and OFF delay is started. Once this time period has elapsed the output is switched OFF. During this OFF delay if signal is reapplied the output switched OFF immediately and ON Delay restarted. -a iming Break 12

Programmable Digital imer FUNCIONAL DIAGAM : upply Voltage, : Input ignal, : elay Output : Preset ime, ON: Preset ON ime, OFF: Preset OFF ime IGNAL ON OFF DELAY YPE 2 [14] On application of signal the preset time () starts. After this preset time has elapsed, output is switched ON. During this timing, if signal is removed then output is switched ON immediately and preset timing is restarted. emoving the signal during this timing suspends timing but does not reset the time sequence. iming will resume immediately when signal is applied. herefore, total time taken before the delayed contact changes state is the preset time plus any time that the signal is removed. Once this time period has elapsed the output is switched OFF. -a ++ iming Break iming Pause LEADING EDGE IMPULE1 [21] On application of input signal the output is immediately switched ON. he output remains ON for the preset time duration () signal is removed during the preset time, the output remains unaffected. IGNAL OFF/ON [15] delay time period () starts. During this timing if signal is removed then timing is stopped and timing will be restarted when signal applied again. After this time period has elapsed output is switched ON. On removal of input signal, the preset time period starts again & the output is switched OFF when the preset time duration is complete. Output stays OFF until supply voltage has been interrupted. iming topped LEADING EDGE IMPULE2 [22] On application of input signal the output is immediately switched ON. he output remains ON for the preset time duration () signal is removed during the preset time, the output is immediately switched OFF. IMPULE ON ENEGIZING [16] On application of supply voltage, the output is instantly switched ON for the preset time duration () after which it is switched OFF. AILING EDGE IMPULE1 [23] When the input signal to the timer is removed, the output is immediately switched ON for the preset time duration () signal is applied during the preset time, the output is immediately switched OFF IMPULE ON/OFF [17] On application or removal of input signal, the output is switched ON & the preset time duration () starts. On completion of the time duration the output is switched OFF. When timing commences, changing the state of the input signal resets the time. AILING EDGE IMPULE2 [24] When the input signal to the timer is removed, the output is immediately switched ON for the preset time duration () signal is applied during the preset time, the output remains unaffected ACCUMULAIVE DELAY ON IGNAL [18] timing duration commences. When input signal is applied, the timing pauses and resumes only when the input signal is removed. he output is switched ON at the end of the preset time duration (). ++ DELAYED IMPULE [25] OFF time duration (OFF) starts. the output is switched ON at the end of the preset OFF time duration & the preset ON time duration commences irrespective of signal level and remains ON till the completion of on. OFF ON ACCUMULAIVE DELAY ON INVEED IGNAL [19] On application of supply voltage and input signal, the preset timing duration commences. When the signal is removed the timing pauses and resumes when the signal is applied. he output is switched ON at the end of the preset time duration (). ++ DELAYED IMPULE YPE 2[26] A permanent supply is required. When signal is applied the output will remain OFF while the first preset time period (OFF) elapses. Once this time period has elapsed OFF ON OFF ON OFF OFF ON the output is switched ON for the second preset time period (ON). Once this second time period (ON) had elapsed then output is switched OFF and cycle stops. Output stays OFF until supply voltage has been interrupted. During timing period (ON or OFF) if signal is removed then output is switched OFF and the cycle stops, cycle will start with output OFF state when the input signal applied again. ACCUMULAIVE IMPULE ON IGNAL [20] On application of supply voltage the output is switched ON & the preset timing duration commences. When the signal is applied the timing pauses and resumes when the signal is removed. he output is switched OFF at the end of the preset time duration (). ++ DELAYED PULE (CONAN UPPLY) POWE BAED [27] he timing period (OFF) starts when the supply is applied to the timer. After the preset has elapsed output is switched ON for the preset pulse (ON) duration. o reset the timer the supply has to be interrupted. If this interruption occurs during the pulsed output (ON) then the output is switched OFF and the timer will reset. OFF ON OFF 13

Programmable Digital imer FUNCIONAL DIAGAM : upply Voltage, : Input ignal, : elay Output : Preset ime, ON: Preset ON ime, OFF: Preset OFF ime DELAYED PULE (EMOE IG.) [28] ON PULE he timing period (OFF) will start when input signal is applied with the supply connected. After preset time (OFF) has OFF ON elapsed the output is switched ON for the iming topped & elay OFF per-selected pulse (ON) duration. o reset the timer either input signal needs to be removed or supply has to interrupt. If this action occurs during the pulsed output cycle (ON) then output is switched OFF and the timer will reset. WACH DOG YPE [30] (CONOL WICH EEABLE) / When the supply is connected and signal is applied, output is switched ON and the timing function starts. If signal is removed and applied during the preset timing then timing is restarted and output stays ON. After preset time(on) has elapsed the output is switched OFF DELAYED PULE (CON. UPPLY YPE 1) [29] iming eloaded On application of supply voltage the output is switched ON. he first pulse of input signal starts the preset time period. eceiving pulses during the time period iming eloaded extends it and output stays ON. eceiving no signal pulses during the time period completes it and output is switched OFF. Output stays OFF until supply voltage has been interrupted. LEADING EDGE BI-ABLE O EP ELAY [32] After every signal, the output contact changes their states, alternately switching from open to close and vice versa. EMINAL OQUE & CAPACIY CONNECION DIAGAM orque - 0.50 N.m (3.5 Lb.in) erminal screw - M3 olid Wire - 1 X 0.12...2 mm2 5 AWG ON PULE (UPPLY EE)[31] upply to the unit must be continuous. On application of input signal the time period 'OFF' starts to run. On completion of OFF ON OFF ON 'OFF', the relay output is switched ON immediately and the time period 'ON' starts to run. On completion of 'ON' the output is switched OFF. he input signal has no effect until' OFF' + ' ON' have completely expired. Ø 3.5 mm 1X26 to 14 6 7 8 4 9 3 2 10 1 11 MOUNING DIMENION (mm) GID ING GID ING 48.0 92.5 V7DF3 V7DD3 PANEL CUOU 14 58.2 53.0 48.0 106.5 42.0