European Technical Assessment. ETA-14/0426 of 21 December English translation prepared by DIBt - Original version in German language

Similar documents
European Technical Assessment. ETA-14/0426 of 15 December English translation prepared by DIBt - Original version in German language

Powers Trak-It XH and HD nails for gas actuated tools C4 and C5

European Technical ETA-13/1038 Assessment of 26 January 2018 General Part

European Technical Assessment. ETA-16/0929 of 3 July English translation prepared by DIBt - Original version in German language.

Klaus-Fischer-Straße Waldachtal DEUTSCHLAND EAD This version replaces ETA-07/0025 issued on 14 May 2018

European Technical Assessment ETA-04/0101 English translation prepared by DIBt. Page 2 of 12 1 March 2018

European Technical Assessment. ETA-09/0338 of 18 June English translation prepared by DIBt - Original version in German language.

Klaus-Fischer-Straße Waldachtal DEUTSCHLAND EAD This version replaces ETA-15/0352 issued on 12 April 2016

European Technical ETA-17/0130 Assessment of 4 December 2017 General Part

European Technical Assessment. ETA-18/0861 of 12 November English translation prepared by DIBt - Original version in German language

Fosroc International Limited Drayton Manor Business Park Coles Road TAMWORTH STAFFORDSHIRE; B78 3XN GROSSBRITANNIEN EAD

European Technical Assessment. ETA-18/0045 of 22 February English translation prepared by DIBt - Original version in German language

ANCHORING TECHNOLOGY CAST-IN CHANNELS PEC-TA

European Technical ETA-17/0513 Assessment of 27 October 2017 General Part

concrete Apolo MEA Befestigungssysteme GmbH Industriestraße Aichach DEUTSCHLAND Apolo MEA Befestigungssysteme GmbH, Plant2 Germany

European Technical ETA-17/0450 Assessment of 29 January 2018 General Part

European Technical Assessment. ETA-13/0183 of 29 June English translation prepared by DIBt - Original version in German language.

Verbindungselemente Engel GmbH Weltestraße Weingarten DEUTSCHLAND. Manufacturing plant 74437, , ,

European Technical Assessment ETA-04/0038 English translation prepared by DIBt. Page 2 of July 2016

European Technical Assessment ETA-17/1005 of

HUS 6 Screw anchor, Redundant fastening

HK I. Anchor size (carbon steel) HK6 HK6L HK8 Resistance F Rk [kn] 2,0 5,0 5,0

(English language translation, the original version is in French language) fischer Anchor bolt EXA

TECHNICAL DATA SHEET

Subject of approval: fischer concrete screw ULTRACUT FBS II for the temporary fastening of building site equipment

TECHNICAL DATASHEET MULTI ANCHOR GREEN PLUS styrene-free hybrid formulation chemical anchor

European Technical Assessment ETA 15/0029 of 12/06/2017

European Technical Assessment. ETA-12/0056 of General Part. Technical Assessment Body issuing the ETA:

European Technical Approval ETA-03/0017

European Technical Assessment. ETA-16/0902 of 17 March English translation prepared by DIBt - Original version in German language.

European Technical Approval ETA-10/0182

Using Hilti powderactuated. to install suspended metal-framed gypsum board ceilings. The application. Selection of fasteners.

PURE 150-PRO EPOXY ADHESIVE ANCHOR

European Technical Assessment ETA-13/0029 of 11/07/2017

HUS3 redundant SCREW ANCHOR. Technical Datasheet Update: Dec-17

metal anchors fixed on the profile back in combination with special nib bolts Product size covered

HALFEN Anchor channel HTA / Special screw HS

HDA-P HDA-PR HDA-PF Anchor for presetting. HDA-T HDA-TR HDA-TF Anchor for through-fasting. Nuclear ICC. Steel failure

HPD Aerated concrete anchor. Approvals / certificates. Basic loading data (for a single anchor)

REISSER-Schraubentechnik GmbH Fritz-Müller-Straße Ingelfingen-Criesbach DEUTSCHLAND

European Technical Assessment. ETA-15/0667 of Member of. General part

PURE150-PRO CHEMICAL ANCHOR

European Technical Approval ETA-05/0198

Z January 2017

Internal threaded version: HSC-I carbon steel internal version HSC-IR Stainless steel version (A4) Hilti anchor design software

Anchor HSA Fastening. Technology Manual HSA. Stud anchor. Version /

European Technical Approval ETA-10/0413

X-P High Performance Nail for Fastening to Concrete and Wood to Steel applications

HUS-V SCREW ANCHOR. Technical Datasheet Update: Dec-17

English translation authorized by DIBt Original version in German language

Hilti HIT-HY 200 with HIT-Z

European Technical Approval ETA-10/0038

Fastener selection guide. Concrete fastener selection Selecting the right nail for concrete What determines nail performance

European Technical Assessment ETA-11/0024 of 02/03/2017

European Technical Approval ETA-07/0212

HSV EXPANSION ANCHOR. Technical Datasheet Update: Dec-17

Please direct powder-actuated and screw fastening technical inquiries to your local Hilti Field Engineer or Technical Support at

European Technical Assessment ETA-11/0024 of 08/07/2016

Powder Actuated Fastening INTRODUCTION

Hilti HIT-1 / HIT-1 CE Adhesive Anchor System

European Technical Assessment. ETA-12/0373 of Member of. General part

European Technical Approval ETA-13/0630

HVU2 adhesive capsule Anchor design (ETAG 001) / Rods&Sleeves / Concrete

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F

European Technical Approval ETA-08/0165

European Technical Approval ETA-08/0183

European Technical Approval ETA-10/0198

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear

European Technical Assessment ETA-12/0197 of 12/07/2017

Large Diameter Tapcon

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT:

ITB TECHNICAL APPROVAL AT /2011

for HACA stationary fixed two rail ladders with / without safety cage

SECTION MASONRY ANCHORAGE AND REINFORCEMENT. Display hidden notes to specifier. (Don't know how? Click Here)

Hilti X-BT Threaded Fastener Specification. Supplement 02/2012. X-BT threaded fasteners for use in nuclear power plants

Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models

WELDA FASTENING PLATES

STRUCTURAL ATTACHMENTS

BX 3 system: fasteners for Interior Finishing, Mechanical and Electrical and Building Construction applications

European Technical Assessment. ETA-08/0285 of General Part. Technical Assessment Body issuing the ETA:

Wedge Type Anchors. Trubolt. Wedge Anchor ADVANTAGES

+ + CFA Guidance Note: Powder Actuated Fixing Systems. Ensuring best fixings practice. Contents. 1.

Letter of Transmittal/Submittal

X-HS Threaded Hanger and X-CC Loop Hanger Systems

English translation authorized by DIBt Original version in German language

European Technical Approval ETA-08/0007

Dowel-type fasteners. Timber Connections. Academic resources. Introduction. Deferent types of dowel-type fasteners. Version 1

Technical Data. DrillFast Stainless DF12-SSA4 Standard Fasteners. Stainless steel self-drilling fasteners for roofing and cladding

HSL-3 / HSL-3-R EXPANSION ANCHOR. Technical Datasheet Update: Oct-18

Erstantie 2, FIN Villähde Tel , Fax

Optimast Installation Method Statement. F108.

Eurocode EN Eurocode 3: 3 Design of steel structures. Part 1-1: General rules and rules for buildings

JVI Vector Connector

Statement for nail plate LL13 Combi

Trusted ICC ES. Issued 06/2018 HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

Hilti, Inc South 122 nd East Avenue Tulsa, OK

S-BT screw-in stainless steel and carbon steel threaded studs

Technical Data. DrillFast Stainless DF3-SS-A4/316 Grade Standard fasteners. Stainless steel self-drilling fasteners for roofing and cladding

Connectors for Cold-Formed Steel Curtain-Wall Construction

BX 3 system: fasteners for Mechanical & Electrical and Interior Finishing applications

Transcription:

European Technical Assessment ETA-14/0426 of 21 December 2016 - Original version in German language General Part Technical Assessment Body issuing the European Technical Assessment: Trade name of the construction product Product family to which the construction product belongs Manufacturer Manufacturing plant Deutsches Institut für Bautechnik Powder-actuated fastener X-CR52 P8 S15 and X-CR48 P8 S15 Power-actuated fastener for multiple use in concrete for non-structural applications Hilti AG Feldkircherstraße 100 9494 Schaan FÜRSTENTUM LIECHTENSTEIN Hilti AG Werk 1 This European Technical Assessment contains This European Technical Assessment is issued in accordance with Regulation (EU) No 305/2011, on the basis of 13 pages including 3 annexes which form an integral part of this assessment European Assessment Document (EAD) 330083-00-0601 This version replaces ETA-14/0426 issued on 15 December 2014 Z70822.16 8.06.01-505/16

European Technical Assessment ETA-14/0426 Page 2 of 13 21 December 2016 The European Technical Assessment is issued by the Technical Assessment Body in its official language. Translations of this European Technical Assessment in other languages shall fully correspond to the original issued document and shall be identified as such. Communication of this European Technical Assessment, including transmission by electronic means, shall be in full. However, partial reproduction may only be made with the written consent of the issuing Technical Assessment Body. Any partial reproduction shall be identified as such. This European Technical Assessment may be withdrawn by the issuing Technical Assessment Body, in particular pursuant to information by the Commission in accordance with Article 25(3) of Regulation (EU) No 305/2011. Z70822.16 8.06.01-505/16

European Technical Assessment ETA-14/0426 Page 3 of 13 21 December 2016 Specific part 1 Technical description of the product The powder-actuated fasteners Hilti X-CR48 P8 S15 and X-CR52 P8 S15 made of stainless steel are driven in a pre-drilled hole in the concrete by using a powder-actuated fastening tool and a cartridge as propellant charge. They are anchored in the concrete by sintering and mechanical interlock. The product description is given in Annex A. The characteristic material values, dimensions and tolerances of the fastener not given in Annex A correspond to the respective values laid down in the technical documentation of this ETA. The technical documentation of this ETA is deposited at the Deutsches Institut für Bautechnik. 2 Specification of the intended use in accordance with the applicable European assessment Document The performances given in Section 3 are only valid if the fastener is used in compliance with the specifications and conditions given in Annex B. The verifications and assessment methods on which this European Technical Assessment is based lead to the assumption of a working life of the fastener of at least 50 years. The indications given on the working life cannot be interpreted as a guarantee given by the producer, but are to be regarded only as a means for choosing the right products in relation to the expected economically reasonable working life of the works. 3 Performance of the product and references to the methods used for its assessment 3.1 Mechanical resistance and stability (BWR 1) Essential characteristic Characteristic and design values of resistance and displacements in noncracked and cracked concrete Durability Performance See Annex C1 and C2 Durability is ensured if the specifications of intended use according to Annex B are taken into account. 3.2 Safety in case of fire (BWR 2) Essential characteristic Reaction to fire Resistance to fire Performance Anchorages satisfy requirements for Class A1 See Annex C3 4 Assessment and verification of constancy of performance (AVCP) system applied, with reference to its legal base In accordance with EAD No. 330083-00-0601, the applicable European legal act is: 1997/463/EC. The system to be applied is: 2+ Z70822.16 8.06.01-505/16

European Technical Assessment ETA-14/0426 Page 4 of 13 21 December 2016 5 Technical details necessary for the implementation of the AVCP system, as provided for in the applicable European Assessment Dcoument Technical details necessary for the implementation of the AVCP system are laid down in the control plan deposited at Deutsches Institut für Bautechnik. Issued in Berlin on 21 December 2016 by Deutsches Institut für Bautechnik Andreas Kummerow beglaubigt: p. p. Head of Department Wittstock Z70822.16 8.06.01-505/16

Page 5 of European Technical Assessment Powder-actuated fasteners X-CR48 P8 S15 and X-CR52 P8 S15 Nail Plastic washer Steel washer washer Installed condition Product and intended use Annex A1

Page 6 of European Technical Assessment Powder-actuated fasteners: dimensions and identification (stamping of steel washer) X-CR48 P8 S15 (L = 50 mm) X-CR52 P8 S15 (L = 54 mm) Stamping Stamping or Table 1: Dimensions and materials Powder-actuated fastener X-CR48 P8 S15 X-CR52 P8 S15 Shank length [mm] 48 52 Total length [mm] 50 54 Shank diameter [mm] 4 4 Head diameter [mm] 8 8 Material of nail [-] Austenitic stainless Cr-Ni-steel (A4), f uk = 1800 N/mm 2 Material of steel washer [-] Austenitic stainless steel, material No. 1.4435, EN 10088 Material of plastic washer [-] Propylene Dimensions, identification and materials Annex A2

Page 7 of European Technical Assessment Specification of intended use Anchorages subject to: Static and quasi-static loads. Base material: Reinforced or unreinforced normal weight concrete according to EN 206-1:2000. Strength classes C20/25 to C50/60 according to EN 206-1:2000. Cracked and non-cracked concrete. Use conditions (Environmental conditions): Structures subject to dry conditions. Structures subject to external atmospheric exposure (including industrial and marine environment) and to permanently damp internal condition, if no particular aggressive conditions exist. Note: Particular aggressive conditions are e.g. permanent, alternating immersion in seawater or the splash zone of seawater, chloride atmosphere of indoor swimming pools or atmosphere with extreme chemical pollution (e.g. in desulphurization plants or road tunnels where de-icing materials are used). Design: Verifiable calculation notes and drawings shall be prepared taking account of the loads to be anchored. The position of the anchor is indicated on the drawings (e.g. position of the fastener relative to reinforcement or to supports etc.). The anchorages are designed under the responsibility of an engineer experienced in anchorages and concrete work. The anchorages are designed in accordance with ETAG 001, Annex C, Method C, August 2010. The fastener is to be used only for multiple use for non-structural applications with following definition: - Number of fixing points n 1 4, number of fasteners per fixing point n 2 1 and design value of actions F sd per fixing point n 3 3.0 kn or - Number of fixing points n 1 3, number of fasteners per fixing point n 2 1 and design value of actions F sd per fixing point n 3 2.0 kn. The design of the fixture is such that in the case of excessive slip or failure of one fastener the load can be transmitted to neighboring fasteners without significantly violating the requirements on the fixture in the serviceability and ultimate limit state. The value n 3 can be increased, if it is shown in the design that the requirements for strength and stiffness of the fixture at the serviceability and ultimate limit state is met after failure of one fastener. Installation: Fastener installation carried out by appropriately qualified personnel and under the supervision of the person responsible for technical matters of the site. Specification of intended use Annex B1

Page 8 of European Technical Assessment Table 2: Concrete strength classes and installation parameters Powder-actuated fastener X-CR48 P8 S15 X-CR52 P8 S15 Minimum concrete strength class [-] C20/25 Maximum concrete strength class [-] C50/60 Nominal diameter of drill bit [mm] 5 Cutting diameter of drill bit [mm] 5.4 Depth of pre-drilling [mm] 23 Depth of penetration (see Annex A1) [mm] 40 45 Maximum diameter of clearance hole or slot width in the fixture [mm] 5.0 1) Total thickness of fixture t fix [-] 1 5 2) 5 9 3) Maximum nail head standoff h NVS according to Annex C2 [mm] 5 Minimum thickness of concrete member [mm] 100 1) 2) 3) An increase up to 6.5 mm is allowed for single and double fastenings, i.e. for maximum 2 powder-actuated fasteners per fixing point (n 2 2). In that case the displacement in shear direction needs to be increased with 0.75 mm (Annex C1). Maximum 6 mm in case of supplemental washers according to Annex C2 Maximum 10 mm in case of supplemental washers according to Annex C2 Predrilling Hilti DX-Kwik step shank drill bit: TX-C 5/23 or TX-C 5/23B Concrete strength class and installation parameters Annex B2

Page 9 of European Technical Assessment Powder-actuated fastening tools DX 5 F8 and DX 460 F8, cartridges 6.8/11M DX 5 F8 DX 460 F8 Piston: X-5-460-P8 Fastener guide: X-5-460-F8 Piston: X-460-P8 or X-5-460-P8 Fastener guide: X-460-F8 or X-5-460-F8 Yellow: Low medium load (level 4) Red: Medium high load (level 6) Black: Extra high load (level 7) Wheel on tool allowing regulation of the driving energy: Setting 1: Minimum energy Setting 4: Maximum energy Cartridge selection: C20/25 C30/37: Yellow / Red C35/45 C50/60: Red / Black The powder-actuated fasteners are to be driven flush. After installation the nail head standoff h NVS has to meet the values given in Annex C2. The driving energy is adjusted at the fastening tool by means of trial installations. If the powder-actuated fastener cannot be driven flush at maximum tool setting (Yellow 4 or Red 4), the next higher cartridge has to be used (Red or Black). The following graph shows the energy overlap of the cartridges Yellow, Red and Black. Yellow 1 Yellow 4 Red 1 Red 4 Black 1 Black 4 Powder-actuated fastening tool and cartridge selection Annex B3

Page 10 of European Technical Assessment Instructions for use Holes to be drilled perpendicular to the concrete surface by using the corresponding stop drill according to Annex B2. The depth of the drill hole is reached when the drill bit leaves a visible mark in the surface of the concrete. Nominal diameter of drill bit and cutting diameter of drill bit shall be in accordance with the values in Annex B2. Positioning of the drill holes without damaging the reinforcement. In case of aborted drill hole a new drill hole shall be at the distance of 2 x depth of the aborted hole at minimum. By vertical downwards drill holes a drill hole cleaning is necessary. The powder-actuated fastener is driven in a pre-drilled hole in the concrete by using the powder-actuated fastening tool DX 5 F8 or DX 460 F8 according to Annex B3 and a cartridge 6.8/11M as propellant charge. The driving energy shall be determined by fine regulation at test settings according to Annex B3 in relation to the characteristics of concrete (e.g. concrete strength, concrete aggregates). A control by measuring the fastener stand-off shall be done according to Annex C2. The powder-actuated fastener is properly set, if the fixture tightened against the concrete surface and the nail head standoff h NVS is met. Powder-actuated fasteners, which don t carry out the required embedment depth or powder-actuated fasteners without pre-drilling must not be loaded. Example X-CR 52 P8 S15 Instructions for use Annex B4

Page 11 of European Technical Assessment Table 3: Design values and characteristic values, non-cracked concrete, Design method C Hilti X-CR DX-Kwik powder-actuated fasteners X-CR48 P8 S15 and X-CR52 P8 S15 Design value of resistance for all load directions F Rd [kn] 3.6 Characteristic bending resistance of fastener shank 1) M 0 Rk,s [Nm] 13.6 Spacing s 1 = s 2 = s cr = s min [mm] 100 Edge distance c cr = c min [mm] 150 Reduced edge distance for the specific case of c 1 double fastenings (n 2 = 2) according to Annex C2 [mm] 100 Displacement in tension direction at F Rd / F N0 [mm] < 0.1 N [mm] < 0.1 Displacement in shear direction at F Rd / F 2) V0 [mm] 1.11 V [mm] 1.15 1) 2) For intermediate layers (e.g. plastic for thermal insulation of brackets of ventilated facades) up to a thickness of 5 mm, it is not required to consider the lever arm in case of shear loads. Displacements in shear direction are to be increased with 0.75 mm, if the clearance hole in the fixture is 5 mm and 6.5 mm. Table 4: Design values and characteristic values, cracked concrete, Design method C Hilti X-CR DX-Kwik powder-actuated fasteners X-CR48 P8 S15 and X-CR52 P8 S15 Design value of resistance for all load directions F Rd [kn] 1.4 Characteristic bending resistance of fastener shank 1) M 0 Rk,s [Nm] 13.6 Spacing s 1 = s 2 = s cr = s min [mm] 100 Edge distance c cr = c min [mm] 150 Displacement in tension direction at F Rd / F N0 [mm] < 0.1 N [mm] < 0.1 Displacement in shear direction at F Rk / F 2) V0 [mm] 0.63 V [mm] 0.95 1) 2) For intermediate layers (e.g. plastic for thermal insulation of brackets of ventilated facades) up to a thickness of 5 mm, it is not required to consider the lever arm in case of shear loads. Displacements in shear direction are to be increased with 0.75 mm, if the clearance hole in the fixture is 5 mm and 6.5 mm. Annex C1 Characteristic and design values of resistance

Page 12 of European Technical Assessment Reduced edge distance for the specific case of double fastening (i.e. 2 powder-actuated fasteners per fixing point (n 2 = 2), e.g. fastening of brackets of ventilated facades) Brackets vertically oriented Brackets horizontally oriented Fastener inspection fastener stand-off Normal case Specific case of supplemental washers X-CR48 P8 S15: h NVC,max = 10 mm (for t fix,max = 5 mm) X-CR52 P8 S15: h NVC,max = 14 mm (für t fix,max = 9 mm) X-CR48 P8 S15: h NVC,max = 10 mm (for t fix,max = 5 mm) X-CR52 P8 S15: h NVC,max = 14 mm (for t fix,max = 9 mm) Provided the maximum nail head standoff h NVS 5 mm is observed, the use of a supplemental washer is also acceptable in combination with the maximum thickness of fixture t fix,max (5 mm for the X-CR48 and 9 mm for the X-CR52). The maximum allowable local increase of thickness of fixture amounts then to 1 mm. Reduced edge distance in case of special case of double fastening, fastener inspection Annex C2

Page 13 of European Technical Assessment Table 5: Design and characteristic values of resistance in case of fire for all load directions Fire resistance class Hilti X-CR DX-Kwik powder-actuated fasteners X-CR48 P8 S15 and X-CR52 P8 S15 R30 Design value of resistance F Rd,fi(30) [kn] 0.40 Characteristic bending resistance M 0 Rk,fi(30) [Nm] 0.25 R60 Design value of resistance F Rd,fi(60) [kn] 0.35 Characteristic bending resistance M 0 Rk,fi(60) [Nm] 0.20 R90 Design value of resistance F Rd,fi(90) [kn] 0.25 Characteristic bending resistance M 0 Rk,fi(90) [Nm] 0.15 R120 Design value of resistance F Rd,fi(120) [kn] 0.20 R30 to R120 1) Characteristic bending resistance M 0 Rk,fi(120) [Nm] 0.10 Partial safety factor 1) M,fi [-] 1.00 Spacing s cr = s min [mm] 200 Edge distance with fire attack from one side 150 c cr = c min [mm] Edge distance with fire attack from more than one side 300 In the absence of national regulations. Design and characteristic values of resistance in case of fire Annex C3