Technical Specifications Power Supply: V o V (50 60 Hz)

Similar documents
Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

ENERGY-0-RS. Energy Meter. User manual

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

FREQUENCY => CURRENT / VOLTAGE CONVERTER Z111

INSTALLATION MANUAL. SENECA s.r.l. Via Germania, Z.I. CAMIN PADOVA ITALY Tel Fax

Z170REG. Universal converter module with galvanic insulation between 2 analog outputs

USER MANUAL S203TA. Via Austria, PADOVA ITALY. Tel Fax

USER MANUAL S203T. Via Austria, PADOVA ITALY. Tel Fax

Drop lenght. Bus lenght m 2 m POSITION. 01xxxxxxxx 10xxxxxxxx 11xxxxxxxx POSITION BAUD RATE. xx From EEprom

USER MANUAL Z-8TC. Via Germania, Z.I. CAMIN PADOVA ITALY. Via Svizzera, Z.I. CAMIN PADOVA ITALY

2 WIRE - LOOP POWERED AND ISOLATED TRANSMITTER FOR TERMORESISTANCE AND THERMOCOUPLE. resistances. The RTD input may be with 2,3 or 4 wire connection.

Z170REG-1. Universal converter module with galvanic insulation between 2 analog outputs

Rear connector (IDC10) RS485 GND RS485 A IDC 10 RS485 B. Utilizzo Accessorio Z-PC-DINAL2-17,5

USER MANUAL Z-10-D-OUT. Via Austria, PADOVA ITALY. Tel Fax

USER MANUAL Z-3A0. Via Austria, PADOVA ITALY. Tel Fax

SENECA s.r.l. Via Austria, PADOVA ITALY Tel Fax

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

ioselect Z-NET Z-4RTD 4 Channel RTD Input Module

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Modbus communication module for TCX2: AEX-MOD

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

H8238/MCM MODBUS POINT MAP

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202

02/11/2015

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

Data Acquisition Modules/ Distributed IO Modules

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

B850 Boiler House Energy Monitor

02/11/2015

MV110-8AS. Analog input module 8 channel. User guide

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Management Energy Meter Type EM340

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Model ipm Intelligent Power Monitor

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

B850 Boiler House Energy Monitor

Universal-Transducer Multi-E11-MU

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

3 phase energy meters with integrated Serial Modbus interface

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

Multimeter 500CVD21 RTU500 series

Energy Management Energy Analyzer Type EM111

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

Energy Management Energy Meter GM3T E GM3T-RS485 E

SRC-110 Series Zone Controllers with Modbus RTU

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

02/11/2015

PLA 33. Power line analyzer. User and service manual. version 2.4

High precision measurement system for current and voltage IHC-A/B-RM01/03

U1601 ENERGY CONTROL SYSTEM

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

DIN Rail Kilowatt Hour Energy Meters

High Performance Process & Temperature Controllers

Analog Module D1-15P User Manual

SUPPLY NETWORK ANALYZER CVM-96 SERIES

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

Know your energy. Modbus Register Map EM etactica Power Meter

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Excellent low-cost Process & Temperature Controllers

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems

Programmable AC Current Transducer MT418

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

Energy Management Energy Analyzer Type EM210 MID

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Energy Management Energy Analyzer Type EM210

Energy Management Energy Analyzer Type EM112

WIRELESS MODBUS GATEWAY WGW410

HD 48V01T... HD 4977T...

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Single Channel Loop Detector

Light sensor. 24V DC Power Input Common Ground Connection RS485 Data + Open Collector Output 2. Analogue Current Output Analogue Voltage Output

Programmable AC Voltage Transducer MT416

EM-72 Electricity Meters for Current Transformers

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

USER MANUAL ZC-24DI. Via Austria, PADOVA ITALY. Tel Fax

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

02/11/2015

3-phase meter with direct connection and pulse or Modbus RS485 output

02/11/2015

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

Theta 20A / 20V. Technical Data Sheet. Special Features

PEM353. Universal measuring device

TAS APFC Controller / Load Managers with MOD-BUS Interface

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

Tegra 710 and 810 Digital metering with RS485 Modbus TM o/p

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

SRC-110 Series Zone Controllers. BACnet MS/TP. Product sheet CT2.143 SRC-110-BAC

INSTRUCTION MANUAL IM411-U v0.3. EMT-4s Series MULTIFUNCTIONAL TRANSDUCER

Transcription:

EN Z203-1 General Description Input/etransmitted output Voltage Input : Current Input : Class/Base Precision : Advanced Single-phase Network Analyser Model Z203-1 is a complete single-phase network analyser suited for use with up to 500 Vac voltage range and 5 A (35 to 75 Hz) current. The instrument provides all the following electrical measurable quantities : Vrms, Irms, Watt, Var, Frequency, Energy, Cos. Measurements are read through serial communication and both floating point and normalised format (except for energy). The DIP-switches (or Modbus registers) can be set for the analogue retransmission of any Vrms, Irms, Watt, Var, Frequency, and Cos quantity. The module is also distinguished by: Facilitated power supply and serial bus wiring by means of the bus housed in the DIN rail. Communication configurability through DIP-switch or software. s485 serial communication with MODBUS-TU protocol, maximum 32 nodes. Power input isolation: 3750 Vac respect to all the other circuits. Isolation between communication and power supply: 1500 Vac. Isolation between retransmitted output and power supply: 1500 Vac. Analogue output signal settable in voltage or current. Possibility for connection and management by an external CT (only if Z203-1 is configurated by a configuration software). Energy counter: pulse digital output, reading on Modbus register (the count is saved into retentive memory). Easy configuration with the software Easy, downloadable from www.seneca.it Technical Specifications Power Supply: 10 40 V o 19 28 V (50 60 Hz) Consumption: max 2.5 W Communication Ports: -S485, 1200..115200 Baud. -S232, 2400 Baud, Address: 01, Parity: NO, Data: 8 bits; Stop bits: 1. Protocol: Analog Output Output Voltage : Output Current : Transmission error : MODBUS-TU Installation category: II (Up to 300 V) up to 500 Vac; frequency: 35 to 75 Hz. Current input rated range: 5 Arms, Max peak factor: 3, Max Current : 15 A, Frequency: 35 to 75 Hz. Voltmeter : 0,5 %. Amperometer : 0,5 %. Wattmeter : 0,5 %. (active power) 0..10 Vdc, 0..5 Vdc, minimum load resistance: 2 k. 0..20 ma, 4..20 ma, maximum load resistance: 500 0,1 % (max. range). ENGLISH - 1/16

Digital Output for pulses (energy counter) Type : ange : Insulation : Screw terminal : Insulation voltage : Protection : Environmental conditions : Storage temperature : Signalling by LED : Connections : Box : Dimensions and weight : eference standards : Passive (it must be powered), > 480 50 ma 1500 Vpeak 1 and 6 (common with GND analogue output) 3750 Vac between the measurement input and all the other circuits.1500 Vac between power supply and communication. 1500 Vac between power supply and outputs. IP20. Temperature -10..+65 C. Humidity 30..90 % non-condensing. Altitude: up to 2000 m a.s.l. -20..+85 C Power supply, Fail, S485 communication. -emovable 3-way screw terminals, 5.08 mm pitch. -ear IDC10 connector for DIN rail. -3.5 mm stereophonic front jack for S232 (COM) connection. PA6, black 100 x 112 x 17,5 mm, 140 g. EN61000-6-4 (electromagnetic emission, industrial environment) EN61000-6-2 (electromagnetic immunity, industrial environment) EN61010-1 (safety). All circuits must be insulated from the other circuits under dangerous voltage with double insulation. The power supply transformer must comply with EN60742: Insulated transformers and safety transformers. Notes: - Use with copper conductor. - Use in Pollution Degree 2 Environment. - Power Supply must be Class2. - When supplied by an Isolated Limited Voltage and/or Limited Current Power Supply, a fuse rated max 2,5 A shall be installed in the field. Operating logic The module measures the electrical measurable quantities: Vrms, Irms, Watt, Var, Frequency, Energy, Cos and provides the values in the corresponding MODBUS registers. Except for energy, these measurements are rendered in both floating point and normalized format between 0..+10000 (0..+10000 for absolute value of VA and Cos 350..750 for frequency from 35.0 Hz to 75.0 Hz). The module output transmits one of the previous quantities selected (excluding energy) as either a current or voltage value. The range of the retransmitted output is proportional to the full scale value of the quantity measured: if the signal is a 4..20 ma current signal and the quantity to be transmitted is the Vrms voltage, for example, 4 ma will equal 0 V and 20 ma will equal 500 V because these are the top and bottom full scale values for rms voltage. MI001178E ENGLISH - 2/16

elay scaling can also be selected from 100%, 50 % or 25 %. In the example above, with 50% retransmission scaling, a 4 ma signal will equal 0 V and a 20 ma signal will equal 250 V. The retransmission values saturate at approximately 11 V for voltage outputs and at around 21 ma for current outputs. When the module is switched on, the appropriate setting coefficients are measured (depending on the choice of 50 or 60 Hz frequency). All the settings made will be automatically loaded when the module is reset. The FeAM allows to recovery the energy if a black-out occurs. Note that the Vrms, Irms, Active Power and frequency values are obtained by direct measurement, whereas the energy, eactive Power and cos values are calculated. Active power can be only greater than 0. An example: if reactive power is -2500 VA or +2500 VA (physical value, electric line), corresponding numeric value is +10000 and analogue output (available at the screw terminals) is +10 V (if SW2-2,3= 00 ).If reactive power is 0 VA (physical value, electric line), corresponding numeric value is 0 and analogue output (available at the screw terminals) is 0 V (if SW2-2,3= 00 ). Cosfi has the same behavior of reactive power. See the tables provided in APPENDIX A for the measurement and retransmission ranges in the cases of 50% and 25% scaling. Isolations DIG. OUT A B GNDOUT S485 S232 OUT IN Power supply AC, DC S232 LINE IN LINE OUT Installation rules The module is designed to be installed in vertical position on a DIN 46277 rail. In order to ensure optimum performance and the longest working life, the module(s) must be supplied adequate ventilation and no raceways or other objects that obstruct the ventilation slots. Never install modules above sources of heat; we recommend installation in the lower part of the control panel. Electric connections S485 SEIAL POT AND POWE SUPPLY The electric connections for power supply can be made by using either the terminals or the bus for the Seneca DIN rail. The S485 bus connections are available only by using the bus for the DIN rail. ENGLISH - 3/16

Power supply from terminals 2 3 S485 GND S485 A 10 40 VDC 19 28 VAC Bus connector for DIN rail connections 2.5 W Power supply AC + Power supply AC - 1 S485 B IDC10 There is no isolation between S485 and the retransmitted output. S232 SEIAL POT Connection cable DB9 with a 3.5 mm stereo Jack, can be assembled as indicated in the following figure, or can be bought as an accessory. DB9-F GND Tx 3.5 mm Stereo Jack x GND x INPUT/ETANSMITTED OUTPUT Tx The module accepts an input voltage of up to a maximum 500 Vac. The input voltage is connected to Terminals 10 and 12, whereas the load to be analysed is connected to Terminals 7 and 9. Z203-1 LINE 10 12 LINE IN MAX 500 VAC 2 3 LINE OUT MAX 5 A rms 7 9 LOAD POWE SUPPLY ENGLISH - 4/16

ANALOGUE OUTPUT The module provides an analog output in voltage (0..10 Vdc, 0..5 Vdc) or current (0..20 ma, 4..20 ma). We recommend using shielded cables for the electric connections above. Voltage Output Current Output 5 + 5 + 6 4 There is no isolation between S485 and the analog output. DIGITAL OUTPUT The module has a digital output: each pulse (200 ms) corresponds to a given number of increments of the energy counted (see the register Digital Output atio). Imax=V/=50mA I + EXAMPLE OF CONNECTION WITH AN EXTENAL CT (in this case, configure the Z203-1 using software, NOT dip-switch) P P1/K CT - + V P2/L 6 1 Digital output N 230Vac S1/K N.C. S2/L I I LOAD 7 9 10 12 Z203-1 Indications by LED on the frontal panel PW LED (GEEN) Steady ON Meaning Power supply is present. ENGLISH - 5/16

E LED (YELLOW) Meaning Steady ON Communication error between internal peripherals. Flashing Voltage measured at less than 40 Vac and at less than 20 ma. X LED (ED) Steady ON TX LED (ED) Steady ON Meaning Data are being received through the S485 communication port Meaning Data are being transmitted through the S485 communication port Serial interface For detailed information on S485 serial interface, consult the documentation provided by the website www.seneca.it, in the section Prodotti/Serie Z-PC/MODBUS TUTOIAL. DIP-SWITCH SETTING Default configuration The instrument leaves the factory with all DIP-switches configured in position 0. The settings of the DIP-switches defines the module's communication parameters: address and speed. In all the following tables, the indication corresponds to a DIP-switch set in 1 (ON); no indication is provided when the DIP-switch is set in 0 (OFF). BAUD ATE SW1 1 2 9600 Baud 19200 Baud 38400 Baud 57600 Baud ADDESS SW1 3 4 5 X X X 6 X 7 8 X X Communication Parameters from EEPOM (*) Fixed Address: 01 Fixed Address: 02 Fixed Address: 03 Fixed Address: 04 Fixed Address, as from binary representation. Fixed Address: 63 NOMINAL FEQUENCY (50 or 60 Hz) SW2 1 Network Frequency: 50 Hz Network Frequency: 60 Hz ENGLISH - 6/16

OUTPUT TYPE SW2 2 3 0..10 V 0..5 V 0..20 ma 4..20 ma ETANSMISSION SCALING (OUT. ANGE) SW2 4 5 100% 50 % 25 % Not allowed (*) The default configuration is the following: Address 1, 38400, no parity, 1 stop bit. SELECTION OF QUANTITY ETANSMITTED (ET. OUTPUT) SW2 6 7 8 Not allowed ( configuration by EEPOM if SW2-1..8 are all «0») etransmission of Vrms etransmission of Irms etransmission of Watt etransmission of cos etransmission of frequency etransmission of VA Not allowed TEMINATO S485 SW3 1 2 x x Terminator OFF, the SW3-2 is not used. Terminator ON, the SW3-2 is not used. Programming For the product's programming and/or configuration tools, consult the website www.seneca.it. During initial programming, the EEPOM (SW3..8 in OFF position) default setting values originally programmed as follows can be used: Address = 01, SPEED =38400 Baud, PAITY= none, BIT NUMBE = 8, STOP BIT=1. The module can also be programmed through the front connector (COM) while paying attention to set the following connection parameters: Address = 01, Speed =2400 Baud, PAITY =none, STOP BIT = 1. The Com communication port behaves in the same way as the S485 bus port except for the communication parameters described above. It also has priority over the S485 serial port and closes after 15 seconds of inactivity. ENGLISH - 7/16

Frontal Panel and Led 1 2 3 4 5 6 E PW X COM TX Z203 7 8 9 10 11 12 Dip-switch and Modbus register If all the dip-switch of SW2 are equal to zero, so 00000000 : the module acquires the configuration from EEPOM for: nominal frequency, output-type, outputelectric value, retransmitted output, electric start scale, electric end scale (see the modbus registers). If at least one dip-switch of SW2 is different from zero: the module acquires only the configurations appliable from dip-switch SW2. For example: if SW2 is equal to 1 00 00 001, then the nominal frequency is configurated as 60 Hz from dip-switch, the output type is configurated as 0..10 V from dip-switch, the retransmission scaling is configurated as 100% and the retransmitted output is VMS. In this case, the content of the registers 40110/40111, 40112/40113 (retransmitted output range), 40114/40115, 40116/40117 (analogue output range) are not acquired for the scaling. Overall Dimensions 17,5 mm 100 mm ENGLISH - 8/16

MODBUS EGISTES Z203-1 has MODBUS 16 bits (words) registers, accessible by S485 or S232 serial communication. In the next paragraphs, we shall describe the supported MODBUS commands, and the functions of the registers. Supported MODBUS Commands Code 03 06 Function ead Holding egisters Write Single egister Description eading of registers up to 16 words at a time within the same group. Writing of a word register Holding egisters The 16-bit Holding egisters have the following structure: Most Significant bit Bit Index Least Significant bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Word (16 bits): MODBUS egister The Bit notation [x:y] shown in the table indicates all the bits from x to y. For example, Bit [2:1] indicates bit 2 and bit 1, and illustrates the meaning of the various linked combinations of the values of the two bits. emember that the MODBUS 3 and 6 functions (respectively of multiple reading and single writing) can be executed on the following registers. Default values are marked with * symbol. The following indication (only readable or also writable) is provided for every register: : eadable W: Writeable ENGLISH - 9/16

GOUP 1 EGISTE MACHINE ID Description Bit [15:8]: contain the module's ID Bit [7:0] contain the firmware's external revision. ADD. 40001 /W ADD Bit [15:8] Bit [7:0] egister for the setting of the module's address and parity control. Set the module's address. Permissible values from 0x00 to OxFF (decimal values in the interval of 0-255 ). Default address: 1. Set the type of parity control: 00000000 : No parity ( NONE )*(Default) 00000001 : Even parity ( EVEN ) 00000010 : Odd parity ( ODD ) 40002 /W BAUD Bit [15:8] Bit [7:0] egister for the setting of the Baud rate and the response delay time in characters. Set the serial communication speed value (Baudrate): 00000000 (0x00) : 4800 Baud 00000001 (0x01) : 9600 Baud 00000010 (0x02) : 19200 Baud 00000011 (0x03) : 38400 Baud *(Default). 00000100 (0x04) : 57600 Baud 00000101 (0x05) : 115200 Baud 00000110 (0x06) : 1200 Baud 00000111 (0x07) : 2400 Baud Set the response delay time in characters that represents the number of pauses of 6 characters each to be entered between the end of the x message and the start of the Tx message. Default value: 0 (hexadecimal: 0x00). 40003 /W CT_ATIO egister for the setting of the coefficient of the CT connected to the instrument. Set the coefficient for any CT connected to the module. The transformation ratio multiplied by 10 must be entered. This coefficient will influence the floating point value of IMS, Active Power and eactive Power, but will not influence the integer (0-10000) and retransmission values. Default: 10 (retransmission is not influenced by CT value, if configuration from Dipswitch) 40004 /W FW_CODE egister containing the firmware's internal code. 40005 ENGLISH- 10/16

FEQUENCY egister to set the network frequency 40007 /W If the dip switch Sw2 are configurated as «00000000»: 0=50 Hz; 1=60 Hz OUT TYPE egister to set the range of the analogue output If SW2 are equal to 00000000, analogue output is: 0=voltage; 2=current. In this case, start scale output is reg.40114/40115, end scale output is reg.40116/40117 40008 /W ELECTICAL MEASUE TO OUT egister to set the retransmitted output If SW2 are equal to 00000000 : 0=VMS; 1=IMS; 2=potentiometer; 3=cosfi; 4=frequency; 5=VA; otherwise: see the Dip-switch table 40009 /W GOUP 2 ENEGY_M Measure of energy in unsigned long (most significant word) 40079 Measure of energy in W/h (MSW). ENEGY_L Measure of energy in unsigned long (least significant word) 40080 Measure of energy in W/h (LSW). VMS_FLOAT_M Vrms voltage measurement in floating point (most significant word) 40081 Vrms voltage measurement in V (MSW). VMS_FLOAT_L Vrms voltage measurement in floating point (least significant word) 40082 Vrms voltage measurement in V (LSW). IMS_FLOAT_M Irms current measurement in floating point (most significant word ). 40083 Irms current measurement in ma (MSW). IMS_FLOAT_L Irms current measurement in floating point (least significant word ). 40084 Irms current measurement in ma (LSW). ENGLISH - 11/16

WATT_FLOAT_M Active power measurement in floating point (most significant word ). 40085 Active power measurement in W (MSW). WATT_FLOAT_L Active power measurement in floating point (least significant word ). 40086 Active power measurement in W (LSW). FEQ_FLOAT_M Frequency measurement in floating point (most significant word) 40087 Frequency measurement in Hz (MSW). FEQ_FLOAT_L Frequency measurement in floating point (least significant word) 40088 Frequency measurement in Hz (LSW). VAMS_FLOAT_M eactive power measurement (in VArms) in floating point (most significant word). 40089 eactive power measurement in VArms (MSW). VAMS_FLOAT_L eactive power measurement (in VArms) in floating point (least significant word). 40090 eactive power measurement in VArms (LSW). COS _FLOAT_M Cos measurement in floating point (most significant word) 40091 Cos measurement (MSW). COS _FLOAT_L Cos measurement in floating point (least significant word) 40092 Cos measurement (LSW). ENGLISH - 12/16

GOUP 3 STATUS Status egister 40093 /W Bit 7 Bit [6:5] Zero cross error 1: signals that the input voltage is less than 40 V. eserved. Bit 4 Bit [3:1] Bit 0 Communication error with the sensor: 1: signals an error of communication with the sensor. eserved. 1: Communication error with Feram VMS_INT egister containing the measurement of the Vrms voltage in 0.. 10000 scale. Measurement of the Vrms voltage with 0.. 10000 scale. 40095 IMS_INT egister containing the measurement of the Irms current in 0.. 10000 scale. Measurement of the Irms current with 0.. 10000 scale. 40096 WATT_INT egister containing the measurement of the active power in 0.. 10000 scale. Measurement of the active power with 0.. 10000 scale. 40097 VA_INT COS _INT egister containing the measurement of the reactive power in 0..+ 10000 scale. Measurement of the reactive power with 0..+10000 scale (absolute value) egister containing the measurement of cos in 0.. + 10000 scale. Measurement of cos (absolute value) 40098 40099 FEQUENCY Measure of frequency 40101 Measure frequency between 350 (35.0 Hz) and 750 (75.0 Hz) ENGLISH - 13/16

COMMAND egister of command 40102 /W 0xB ACA: this command loads the value CommandAux in the register energy; 0x6500 forces the ESET of the module. COMMANDAUX_M egister of auxiliary command (most significant word) 40103 /W Value to load in the register energy COMMANDAUX_L egister of auxiliary command (least significant word) 40104 /W Value to load in the register energy STAT SCALE ELECTIC_M END SCALE ELECTIC_L Electrical start scale of retransmitted output in floating-point (most significant word) start scale value. To know which input is acquired, see reg.40009 (if SW2 are 00000000 ) Electrical start scale of retransmitted output in floating-point (least significant word) 40110 40111 /W /W As the previous (least significant word) STOP SCALE ELECTIC_M Electrical end scale of retransmitted output in floating-point (most significant word) stop scale value. To know which input is acquired, see reg.40009 (if SW2 are 00000000 ) 40112 /W STOP SCALE ELECTIC_L Electrical end scale of retransmitted output in floating-point (least significant word) 40113 /W As the previous (least significant word) STAT SCALE OUTPUT_M Start scale of analogue output in floatingpoint (most significant word) 40114 /W Output start scale value. To know the analogue output, see reg.40008 (if SW2 are equal to 00000000 ) STAT SCALE OUTPUT_L Start scale of analogue output in floatingpoint (least significant word) 40115 /W As the previous (least significant word) ENGLISH - 14/16

STOP SCALE OUTPUT_M Stop scale of analogue output in floating-point (most significant word) Output stop scale value. To know the analogue output, see reg.40008 (if SW2 are equal to 00000000 ) 40116 /W STOP SCALE OUTPUT_L Stop scale of analogue output in floating-point (least significant word) 40117 /W As the previous (least significant word) DIG. OUT ENEGY ATIO_M Digital output energy ratio (unsigned long, most significant word) Partition coefficient with which a pulse is generated. If it is 1: the pulse is generated for each unit increment of energy, if it is 10: the pulse is generated every 10 increments of energy, etc... 40118 /W DIG. OUT ENEGY ATIO_L Digital output energy ratio (unsigned long, least significant word) 40119 /W As the previous (least significant word) ENEGY ATIO_M Energy ratio (most significant word) 40120 /W Multiplier coefficient with which the energy counter is incremented. If it is 1: the energy is counted as W/h, if it is 0,001: the energy is counted as kw/h, etc... Default: 0,001 ENEGY ATIO_L Energy ratio (least significant word) 40121 /W As the previous (least significant word) ENGLISH - 15/16

APPENDIX A : etransmission scaling (from Dip-Switch) 100 % Scaling: etransmission scaling Electrical Quantities Vrms Irms Active Power 0..2500 W eactive Power (*) 0..2500VA cos 0..1 Frequency 35..65 Hz 50 % Scaling: etransmission scaling Electrical Measurement Quantities range Selectable analogue output Vrms 0..250 Vrms 0..2,5 A Irms Active Power 0..1250 W eactive Power (*) 0..1250VA cos 0..0,5 Frequency 45..75 Hz 25 % Scaling: etransmission scaling Electrical Quantities Selectable analogue output Vrms Irms Active Power eactive Power (*) cos Frequency (*) absolute values Measurement range 0..500 Vrms 0..5 A Measurement range 0..125 Vrms 0..1,25 A 0..625 W 0..625VA 0..0,25 40..60 Hz Selectable analogue output Disposal of Electrical & Electronic Equipment (Applicable throughout the European Union and other European countries with separate collection programs) This symbol, found on your product or on its packaging, indicates that this product should not be treated as household waste when you wish to dispose of it. Instead, it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences to the environment and human health, which could otherwise be caused by inappropriate disposal of this product. The recycling of materials will help to conserve natural resources. For more detailed information about the recycling of this product, please contact your local city office, waste disposal service or thè retail store where you purchased this product. This document is property of SENECA srl. Duplication and reprodution are forbidden, if not authorized. Contents of the present documentation refers to products and technologies described in it. All technical data contained in the document may be modified without prior notice Content of this documentation is subject to periodical revision. SENECA s.r.l. Via Austria, 26 35127 PADOVA ITALY Tel. +39.049.8705355-8705359 - Fax +39.049.8706287 For manuals and configuration software, please see:www.seneca.it ENGLISH - 16/16