DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

Similar documents
DC1010/DC1020/DC1030/DC1040

General Purpose Digital Controllers Specifications

PID CONTROLLERS LT SERIES

PROCESS & TEMPERATURE CONTROLLERS

APPENDIX APPENDIX A 1

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

MICRO-CONTROLLER X (48 48 mm)

MICRO-CONTROLLER X (96 96 mm)

High Performance Process & Temperature Controllers

Ramp/Soak Temperature Controller REX-P250

SHIMADEN DIGITAL INDICATORS

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

SHIMADEN DIGITAL INDICATORS

Excellent low-cost Process & Temperature Controllers

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

SHIMADEN DIGITAL INDICATOR

MICRO-CONTROLLER X (48 96 mm)

REX-F400 REX-F700 REX-F900

RUN HLD MAN PRG. Features

General Specifications

SRX. General Description. Features. Module type High-speed Digital Controller SRX. Multi-Zone Space-Saving. High-speed Feedback Control

SDC40A. DigitroniK TM Digital Indicating Controller RSW. Control unit PID (8) Auto tuning+ Neuro & Fuzzy RUN/READY R/L LSP.

General Specifications

SHIMADEN PROGRAM CONTROLLER

PROGRAMMABLE CONTROLLER

AK48 SPECIFICATIONS APPLICATIONS GENERALS FEATURES. 1/16 DIN Process controller

Temperature Controllers E5 J

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

SHIMADEN DIGITAL CONTROLLER

Fuzzy Temperature Controllers E5AF

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

Temperature Controller

DIGITAL INDICATING CONTROLLER

DIGITAL PROGRAM CONTROLLER

PROGRAMMABLE CONTROLLER

Analogue temperature controllers

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

K3P ENG.qxd 23/10/ Pagina 1

General Specifications

Delta Temperature Controller DT Series

Process controller with Modbus Master/Slave & PROFIBUS DP 1/8 DIN - 48 x 96 mm Platinum Series X5000 Line

CT325 Miniature DC Temperature Controller

DigitroniK TM Digital Indicating Controller SDC40A

Process and Temperature Controllers

DigitroniK TM Digital Indicating Controller SDC20

SHIMADEN PROGRAMMABLE CONTROLLER

General Specifications

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

PROGRAM CONTROLLER OUTLINE


General Specifications

Temperature Controls

Series Valve Temperature Controller. Instruction Sheet

General Specifications

C C1 C2 AL1 AL2 AL3. Micro-controller X. Model: PXR SEL PXR-4. Operation Manual. ECNO:406a

Model Number Structure

SHIMADEN DIGITAL CONTROLLER

MODEL: TC10EM. Temperature Controller TC10 Series

DPF-MAC Auto power factor controller

Table of Contents Panel Mount Controllers Analog Series C-Series Controller Software Legacy Series Power Controllers Analog Series P-Series

General Specifications

General Specifications

* Our controllers can be used with other brand of strain gauge sensors. Please contact RKC for more details. DO1 Control output (CH1)

TTM-339 TTM-339 PROGRAM CONTROLLER

PID Controller-Single Loop (1/16 DIN - Microcontroller Based) (Product Code 10.10)

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

General Specifications

SDC45V/46V. DigitroniK TM Digital Indicating Controller. Control Operation

HA400 HA900 HA401 HA901

Single Loop Controller SDC35/36

8003 1/8 DIN Temperature Controller

CompoBus/D-type Digital Controller

- SMART TUNE - PID CONTROL - UNIVERSAL, 3 WIRE - TC, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER

Micro-controller X SV C1 C2 AL1 AL2 SEL. Model: PXR3. Operation Manual TN5A2704-E

General Specifications

Process displays For standard signals, temperature, resistance measurement

SOLO Temperature Controllers 1/4 DIN

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

Digital Temperature Controller

Network Instrumentation Module Controller Module NX-D15/25/35

1/16 DIN (48 48 mm) temperature controller PXR

MICRO-CONTROLLER X mm

MICRO-CONTROLLER X (48 48 mm)

MICRO-CONTROLLER X (48 96 mm)

6/12/24 Dot Printing Model Smart Recorder SRF206/212/224

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

MODEL: W2TS. Mini-MW Series

PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS

MODEL: R30US4. Remote I/O R30 Series

INSTRUCTION MANUAL FOR PROGRAMMABLE CONTROLLER PCD-33A

Digital Temperature Controller

Model Number Structure

LT23A SERIES. Digital Indicating Controller PSE x48mm compact body Easy to use small size controller at reasonable price CE RoHS compliance

RE92. CHECKMATE. Dual loop controller for industry purpose.

Digital indicator for panel mounting With multi-function input Model DI25

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Models UT350/UT320 Digital Indicating Controllers

Series Temperature Controller Instruction Sheet

Transcription:

01 May 20 30-10-10--EN Page 1 of DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of functionality and reliability at a competitive price. The controllers are available in different formats: 48x48 (1/16 DIN), 48x96 (1/8 DIN), 2x2 (3/16 DIN), 96x96 (1/4 DIN). This controller series is ideal for the control of temperature, humidity, pressure, flow etc. (New Compact type) in a variety of applications including: Plastic Processing Package Machinery Painting and coating Semiconductor packaging / Testing Dryers Features Easy to Configure Different configuration levels provide easy access to parameters. Various Control Algorithm Several different algorithms are available as follows: - PID or ON/OFF Control - Heat/Cool Control with 2 PID sets - Motor Position Control (without slidewire feedback) Auto-Tuning Capability Advanced auto-tuning function calculates the optimized PID values for your specific control system. Dual Display and Bar graph Two large 4 digits display PV, SP and configuration parameters. One 10 LED bar-graph displays the control output (MV), and up to 8 LEDs display the status of the different outputs (Control, Alarm, ) and also provide indication of the Auto/Manual and programmer states. Setpoint Programming Two programs are available with a maximum of 8 segments. The 2 programs can be linked together and perform as a single 16 segment program. Extended Alarm Capability Up to three different alarm outputs are available per instrument and 1 kinds of event modes can be assigned to each of alarm output. Communications RS232 or RS485 (with ASC & Modbus RTU Protocol) is optionally available with a maximum communication speed of 38400 bps. IP65 Front Face Protection IP65 rated front face permits use in applications where it may be subjected to moisture, dust conditions. Remote Setpoint Capability The setpoint can be defined from a remote PLC or other controller. Manual & Automatic Modes The control mode can be switched between Automatic and manual by clicking A/M key. (The A/M key is available with DC1020, DC1030 and DC1040) Global Approvals CE & cul All models are CE certified as a standard, and UL approved version for all models are available optionally. Parameter Lock A 4-digit security code prevents any unauthorized changes of parameters or configurations. Parameters can be hidden to user to prevent any mis-configuration of the unit.

Specifications General Rated power supply voltage 100 to 240V AC 50/60Hz, 8VA max. to 50V DC, 10VA max. Insulation Resistance Over 10 MΩ under DC500V megger between input terminal and case(ground). Over 10 MΩ under DC500V megger between output terminal and case(ground). Withstand voltage 1000V AC 50/60Hz for 1min across input terminal and case(ground) Operating Conditions Transportation and storage conditions Exterior Indication Mounting Ambient Temp. Ambient Humi. Rated Power Supply Allowable Power Supply Power Frequency Vibration Resistance Ambient Temp. Ambient Humi. Vibration Resistance PV/SP indication Const value storage 00V AC 50/60Hz for 1min across output terminal and case(ground) 0 to 50 C 20 to 90%RH (non-condensing) 100 to 240V AC 20 to 50V DC 85 to 264V AC to 55VDC 50 ± 2Hz or 60 ± 2Hz 10m/s 2 (approx. 1G), 10 to 55Hz for 10min each X, Y, Z directions -25 to +65 C 10 to +95% RH (non-condensing) 20m/s 2 (Approx. 2G), 10 to 55Hz for 2 hours each in X, Y, Z directions Double insulation, Case and front panel : plastic 4-digit, -segment display Non-volatile memory(eeprom) Panel-mount Model DC1010 DC1020 DC1030 DC1040 mm Exterior Size (unit: ) inch 50 X 50 X 9 50 X 96 X 9 4 X 4 X 9 96 X 96 X 9 : W X H X D (1.9X1.9X 3.82) (1.9X3.8X3.82) (2.91X2.91X3.82) (3.8X3.8X3.82) mm Panel Cutout (unit: ) inch 44.5 X 44.5 44.5 X 90.5 68.5 X 68.5 90.5 X 90.5 : W X H (1.5 X 1.5) (1.5 X 3.56) (2.9 X 2.9) (3.56 X 3.56) Global Approvals CE, cul Interval = 20.5mm (0.80 in)

DC1050/DC1060 Compact DIGITAL CONTROLLERS Specification Overview (New Compact type) The DC1000 Series are microprocessorbased controllers designed with a high degree of functionality and reliability at a competitive price. Here, DC1050 and DC1060 are compact size and installed on DIN rail. This controller series is ideal for the control of temperature, humidity, pressure, flow etc. in a variety of applications including: Plastic Processing Package Machinery Painting and coating Semiconductor packaging / Testing Dryers Features Compact size and Easy to install Short-body and compact size, installed on DIN rail easily. Various Control Algorithm Several different algorithms are available as follows: - PID or ON/OFF Control - Heat/Cool Control with 2 PID sets - Motor Position Control (without slidewire feedback) Auto-Tuning Capability Advanced auto-tuning function calculates the optimized PID values for your specific control system. Two types of model Advanced and Economic models. Single 4 digits display PV, SP and configuration parameters. Up to 5 LEDs display the status of the different outputs (Control, Alarm, ). Economic model provides to configure parameters. Setpoint Programming Two programs are available with a maximum of 8 segments. The 2 programs can be linked together and perform as a single 16 segment program. Extended Alarm Capability Up to three different alarm outputs are available per instrument and 1 kinds of event modes can be assigned to each of alarm output.(dc1050 : upto two alarms) Heater breaker alarm is available through CT input. Communications RS485 (Modbus RTU Protocol) is optionally available with a maximum communication speed of 38400 bps and advanced communication capability, 1 to 31. Remote Setpoint Capability The setpoint can be defined from a remote PLC or other controller. (For only DC1050.) Manual & Automatic Modes The control mode can be switched between Automatic and manual by clicking A/M key. (The A/M key is available with External Operation panel- KA601 only) Global Approvals CE All models are CE certified as a standard. Parameter Lock A 4-digit security code prevents any unauthorized changes of parameters or configurations. Parameters can be hidden to user to prevent any mis-configuration of the unit. External operation tool Operation panel(ka601) is available and ease to copy or backup the parameters via one USB port.

Specifications General Rated power supply voltage 100 to 240V AC 50/60Hz, 8VA max. Insulation Resistance Over 10 MΩ under DC500V megger between input terminal and case(ground). Over 10 MΩ under DC500V megger between output terminal and case(ground). Withstand voltage 1000V AC 50/60Hz for 1min across input terminal and case(ground) Operating Conditions Transportation and storage conditions Exterior Indication Mounting Ambient Temp. Ambient Humi. Rated Power Supply Allowable Power Supply Power Frequency Vibration Resistance Ambient Temp. Ambient Humi. Vibration Resistance PV/SP indication Const value storage 00V AC 50/60Hz for 1min across output terminal and case(ground) 0 to 50 C 20 to 90%RH (non-condensing) 100 to 240V AC Approx. 4VA 85 to 264V AC 50 ± 2Hz or 60 ± 2Hz 10m/s 2 (approx. 1G), 10 to 55Hz for 10min each X, Y, Z directions -25 to +65 C 10 to +95% RH (non-condensing) 20m/s 2 (Approx. 2G), 10 to 55Hz for 2 hours each in X, Y, Z directions Double insulation, Case and front panel : plastic 4-digit, -segment display Non-volatile memory(eeprom) DIN Rail mount Model DC1050 DC1060 mm Exterior Size (unit: ) inch : W X L X H Global Approvals Interval = 20.5mm (0.80 in) 40 X 10 X43 (1.5X4.21X 1.69) CE 40 X 10 X43 (1.5X4.21X 1.69)

Specifications Input/Output PV Input Number of Point 1 point (TC, RTD or Linear) TC: K, J, R, S, B, E, N, T, W, PL, U, L Type of input RTD : Pt100, JPt100, JPt50 Linear : 4~20mA / 1~5V / 2~10V * Note 1 0~20mA / 0~5V / 0~10V * Note 1 Range Sampling Time Indication Accuracy Refer to Table 1-1. * Temperature unit : ºC, ºF ( switchable) 250 ms ± 0.2% FS ± 1digit (for details Table1-1) Cold accuracy junction ±1.0ºC (under standard conditions) Input bias (offset) Digital Filter LSPL ~ USPL 0-200 sec (0: filter off) Decimal Point 0000, 000.0, 00.00, 0.000 2 nd Input (RSP) CT Input Type of input Sampling Time Type 0~20mA / 0~5V / 0~10V 4~20mA / 1~5V / 2~10V 250ms Measure AC current of single phase SC-80T : 0.0~80.0A Sampling Time Indication Accuracy Resolution Weight Dielectric strength 500msec 1% FS 0.1A ac g 2500Vac, for 1 min between terminal and case NOTE 1. When OUT1 is ON and CT input value is less than HBA set value for 5 seconds, AL1 is activated. Otherwise, AL1 is not activated.

Specification Input/Output Model DC1010 DC1020 DC1030 DC1040 DC1050 DC1060 Relay output SPST SPDT SPST SPDT SPDT SPST 3A, 220Vac, Resistive Load(100,000 time electrical life) PWM(SSR drive), ON: 20 Vdc, OFF: 0 V (max. load current 20mA) Voltage Pulse Open Time Terminal Voltage: 20 Vdc or less Output 1 Time Proportional Cycle Time: 0-0 sec DC Current (ma) : 0~20mA, 4~20mA (load resistance 500Ω) Linear output DC Voltage (V) Accuracy Update Cycle : 0~5V, 0~10V, 1~5V, 2~10V (max. load current 20mA) ± 5% of Span 500m sec Relay SPST SPST SPST SPST SPST SPST 3A, 220Vac, Resistive Load(100,000 time electrical life) Output 2 (* Note 1) Voltage pulse PWM(SSR drive), ON: 20 Vdc, OFF: 0 V (max. load current 20mA) Open Time Terminal Voltage: 20 Vdc or less Time Proportional Cycle Time: 0-0 sec DC Current (ma) : 0~20mA, 4~20mA (load resistance 500Ω) Linear DC Voltage (V) Accuracy Update Cycle : 0~5V, 0~10V, 1~5V, 2~10V (max. load current 20mA) ± 5% of Span 500m sec Output Direction (OUD) Control Mode Output signal No. of point HEAT(Direct)/COOL(Reverse) (Selectable) Auto/Manual operation is switchable. SP, PV retransmission 1 point Aux. output Type of output 4-20mA, 0~20mA, 0~5V, 0~10V, 1~5V, 2~10V Accuracy Sampling time +/- 0.2% of span 500 ms Alarm output Relay AL1 SPST SPDT SPST SPDT SPDT SPST AL2 SPST SPDT SPST SPDT SPST SPST AL3 - SPST SPST SPST - SPST Rate * For Heat/Cool Control Output only. 3A, 220Vac, Resistive Load(100,000 time electrical life)

Specification PID Control & Auto-Tuning Model DC1010 DC1020 DC1030 DC1040 DC1050 DC1060 Proportional Band (P1,P2) Proportional Band: 0.0 ~ 200.0% Integral time (I1, I2) Derivative time (D1, D2) Auto-Tuning Value HYS1, HYS2 Dead Band (DB1) GAP1, GAP2 Cycle Time Communication Speed Protocol Parity check Integral time : 0 ~ 3600 sec 0 ~ 900 sec 0 ~ USPL 0 ~ 1000 (for ON/OFF control) Not defined. 0 ~ 1000(for HEAT/COOL control) 0 ~ 0 sec 00, 2400, 4800, 9600, 19200, 38400 bps ModBus RTU, ModBus ASC Odd / Even Bit length / Start / Stop bit 8 / 1 / 1 or 2 Communication RS232C, RS485 RS485 ALARMS(EVENTS) Channel Max. 3 channels(optional)with HBA 01 / 11 Deviation-High alarm (inhibit / no-inhibit) 02 / Deviation-Low alarm (inhibit / no-inhibit) Code 03 / 13 Deviation High/Low Limit alarm (inhibit / no-inhibit) 04 / Deviation High/Low Limit range alarm (inhibit / no-inhibit) 05 / Absolute High alarm by PV (inhibit / no-inhibit) Mode 06 / 16 Absolute Low alarm by PV (inhibit / no-inhibit) SET VALUE -1999~ USPL (Absolute value, Deviation value) Activation Hysterisis 0 ~ 1000 0 : Flicker Timer 99M 59S : Continued alarm Program System Code Code 00M 01S to 99M 58S : on delay Timer alarm 0 Segment End alarm(in progress of program) 1 Program RUN 08 System Error ON 18 System Error OFF TIME Code 19 Delaying timer (00Hours 00Min ~ 99Hour 59Min) HBA Code 09 Heater Break Alarm for only AL1

Specification Program (Optional) No. of patterns 2 (Program 1 & Program 2) No. of segments Segment time Control output 8 segments/1 program Segment time: Setting by set points(sp) and time (Max. 99hours 59minutes) 0~100% When OUT=0%, Program End. Rear Wait Time may exceed set time of the particular segment. In this case, remaining Program section WAIT function Repeat time is set as 0 and pending; if the temperature that was measured does not reach target value WAIT set point. It proceeds to the next segment after it is confirmed that temperature reach the range of set point (target value WAIT) Setup range: 0 ~ 1000 by decimal point. Repeat(infinitely) / Non-repeat Program link When Program number is 0, Link program 1 and 2. Program start Power Failure TIME UNIT (1) Start from SP=0 (2) Start from PV Hot Start / Cold Start Hour. Minute / Minute. Second

Table 1-1 Analog Input Range (Thermocouple) Input Type Code Temperature Range ºC ºF Indication Accuracy Remarks K1 0.0~200.0 0.0~392.0 K2 0.0 ~ 400.0 0.0~52.0 K K3 0 ~ 600 0~11 K4 0 ~ 800 0~2 K5 0 ~ 1000 0~1832 K6 0 ~ 00 0 ~ 2192 J1 0.0~200.0 0.0~392.0 J2 0.0 ~ 400.0 0.0~52.0 J J3 0 ~ 600 0~11 J4 0 ~ 800 0~2 J5 0 ~ 1000 0~1832 J6 0 ~ 00 0 ~ 2192 R R1 0~1600 0~29 R2 0~169 0~3216 +/-2 ºC under 100 ºC +/-3.6 ºF under 2 ºF TC (Note1) S E S1 0~1600 0~29 S2 0~169 0~3216 B1 0~1820 0~3308 No guarantee at 0 ~ 400ºC E1 0~800 0~2 E2 0~900 0~1652 N N1 0~00 0~2192 N2 0~1300 0~232 T T1-199.9~400.0-199.9~52.0 T2-199.9~200.0-199.9~392.0 +/-1 ºC under -100 ºC +/-1.8 ºF under -8 ºF T3 0.0~350.0 0.0~662.0 W5Re/ W26Re 0~2300 0~3632 0~2320 0~4208 PL PL1 0~1300 0~232 PL2 0~1390 0~2534 U U1-199.9~600.0-199.9~999.9 U2-199.9~200.0-199.9~392.0 +/-1 ºC under -100 ºC +/-1.8 ºF under -8 ºF U3 0.0~400.0 0.0~52.0 L L1 0~400 0~52 L2 0~800 0~2

Table 1-2 Analog Input Range (RTD) Input Type Code Input Type ºC ºF Indication Accuracy Remarks JPt100 JP1-199.9~600.0-199.9~999.9 JP2-199.9~400.0-199.9~52.0 JP3-199.9~200.0-199.9~392.0 JP4 0~200 0~392 +/-0.5 ºC under -100 ºC +/-0.9 ºF under -8 ºF JP5 0~400 0~52 JP6 0~600 0~11 RTD DIN Pt100 DP1-199.9~600.0-199.9~999.9 DP2-199.9~400.0-199.9~52.0 DP3-199.9~200.0-199.9~392.0 DP4 0~200 0~392 +/-0.5 ºC under -100 ºC +/-0.9 ºF under -8 ºF DP5 0~400 0~52 DP6 0~600 0~11 JPt50 JP.1-199.9~600.0-199.9~999.9 JP.2-199.9~400.0-199.9~52.0 JP.3-199.9~200.0-199.9~392.0 JP.4 0~200 0~392 +/-0.5 ºC under -100 ºC +/-0.9 ºF under -8 ºF JP.5 0~400 0~52 JP.6 0~600 0~11 Table 1-3 Analog Input Range (Linear) Input Type Code Source Range Indication Accuracy Remarks AN1-10~10mV AN2 0~10mV Linear AN3 0~20mV -1999~9999 +/-0.1% of span AN4 0~50mV 0-20mA, 0-1V, 0-5V, 0-10V AN5 10~50mV 4-20mA, 1-5V, 2-10V

Picture 1.1 External Dimension : DC101_, DC102_, DC103_, DC104_ (Unit : mm)

Picture 1.2 External Dimension : DC105_, DC106_ (Unit : mm) Operating Panel : KA601 16mm 6mm Cable Length= 0mm 4mm

Picture 1.3 Wiring Diagram DC1010 N POWER L AC 100 ~ 240V (50 / 60Hz) DC ~ 50V (option) Noise Filter 1 6 11 2 3 8 13 4 9 5 10 OUTPUT PV OUT2 Relay 1 2 Volt 2 3 Linear OUT1=5 11 G1 Linear RTD TC B OUT1 3 A,B,C,D Relay Volt Linear 1 2 3 4 13 K1 G2 K2 8 9 B 10 A 8 9 10 8 9 10 ALARM 5 A,B,C,D AL1 AL1 AL2 2 11 13 OUT1= 3 2 3 4 CLOSE OPEN AUX. OUT TRS 11 COMM. COMM RS232 RD 11 COMM RS485 11 D- 5 COM SD D+ CT INPUT CT 11 SG 13 13

Picture 1.4 Wiring Diagram DC1020 L POWER N AC 100 ~ 240V (50 / 60Hz) DC ~ 50V (option) Noise Filter 1 11 2 3 13 4 5 6 16 1 8 18 9 19 10 20 OUTPUT OUT2 Relay Volt Linear 1 2 3 6 PV Linear RTD TC 1 1 1 B OUT1 A,B,C,D Relay Volt Linear NO1 8 2 3 18 19 B 20 A 18 19 20 18 19 20 NC 9 10 COM OUT1= A,B,C,D ALARM AL1 AL2 AL3 3 NC NC 11 6 4 NO NO AUX. OUT 11 TRS 6 5 COM COM 13 13 CLOSE 8 9 OPEN INPUT2 COMM. COMM RS232 RD COMM RS485 D- CT INPUT CT 10 COM SD D+ 16 SG 16 16

Picture 1.6 Wiring Diagram DC1030 L POWER N AC 100 ~ 240V (50 / 60Hz) Noise Filter 1 8 2 16 9 3 1 10 4 18 11 DC ~ 50V (option) 5 19 6 20 13 21 CT INPUT CT 16 OUTPUT OUT2 Relay Volt Linear 1 2 3 3 OUT1=5 G1 PV Linear RTD TC 11 11 11 B OUT1 4 Relay NO1 5 A,B,C,D Volt Linear 2 3 1 19 20 G2 PROT 13 B A 13 13 6 NC COM A,B,C,D ALARM AL1 3 AL2 COM 8 AUX. OUT TRS 18 OUT1= OUT1=8 4 NO 9 19 3 G1 NC 10 4 CLOSE 16 K1 5 OPEN 1 G2 INPUT2 COMM. 6 COM 18 K2 20 21 PROT Remote SP 9 10 COMM RS232 RD SD 16 SG 1 COMM RS485 D- 16 D+ 1

Picture 1. Wiring Diagram DC1040 L POWER N AC 100 ~ 240V (50 / 60Hz) DC ~ 50V (option) Noise Filter 1 31 11 2 32 3 33 13 4 34 5 35 6 36 16 COMM. COMM RS232 RD 31 SD 32 SG 33 COMM RS485 31 D- 32 D+ 33 CT INPUT CT 3 1 8 38 18 9 39 19 AUX. OUT TRS 39 10 40 20 40 OUTPUT PV OUT2 Relay Volt Linear 1 2 3 6 OUT1=6 31 RG OUT1=5 31 G1 Linear RTD TC 1 1 1 B OUT1 A,B,C,D Relay Volt Linear NO1 8 2 3 33 RG 35 TG1 3 TG2 33 39 40 G2 PROT 18 19 B 20 A 18 19 20 18 19 20 NC 9 10 COM OUT1= A,B,C,D 39 PROT 40 OUT1=8 OUT1=9 31 G1 32 K1 ALARM AL1 AL2 AL3 3 NC NC 11 6 4 NO NO 6 31 G1 33 G2 5 COM COM 13 8 CLOSE OPEN 32 K1 33 G2 34 K2 35 G3 INPUT2 Remote SP COMM. COMM RS232 RD COMM RS485 D- 9 34 K2 36 K3 SD D+ 10 COM 35 PROT 39 PROT 16 SG 16 16 36 40

Picture 1.8 Wiring Diagram DC1050 (pitch=3.5mm/0.138inch)

Picture 1.9 Wiring Diagram DC1060 (pitch=5.0mm/0.19inch)

Model Interpretation DC101_,DC102_,DC103_,DC104_ DC1000 Digital Controller Instructions Select the desired Key Number. The arrow to the right marks the selections available. Make one selection each from Tables I through I using the column below the proper arrow. A dot ( ) denotes unrestricted availability. A letter denotes restricted availability. Key Numbers I I DC10 - _ - _ - _ KEY NUMBER Description Selection Availability Size 48 x 48 mm (DIN) 1/16) DC101 _ 48 x 96 mm (DIN 1/8) DC102 _ 2 x 2 mm DC103 _ 96 x 96 (DIN 1/4) DC104 _ Power & Approvals 90-240 Vac Power / CE DC10_0-50 Vdc Power / CE DC10_1 b b b b 90-240 Vac Power / IP 65 / CE DC10_2-50 Vdc Power / IP65 / CE DC10_3 b b b b 90-240 Vac Power / IP65 / CE / UL Agency Approval DC10_4-50 Vdc Power / IP65 / CE / UL Agency Approval DC10_5 b b b b Program None DC10 C_ Program (2 patterns, 8 segments per 1 pattern) DC10 P_ Input RTD DC10 _R TC DC10 _T Linear DC10 _L TABLE I Control Output 1 None 0 Relay, Contact, SPDT, 3A / 240 VAC 1 Volt, Voltage Pulse, 20VDC / 20 ma 2 ma Current, 4-20mA 3 Three Position Step Motor Control c d c 0-5 V A 0-10 V B 1-5 V C 2-10 V D Control Output 2 None _ 0 _ (Heat/Cool) Relay, Contact, SPDT, 3A / 240VAC _ 1 _ Volt, Voltage Pulse, 20VDC / 20mA _ 2 _ ma Current, 4-20mA _ 3 _ 0-5V _ A _ 0-10V _ B _ 1-5V _ C _ 2-10V _ D _ Alarm Event 1 Alarm Relay 1 e i & Heat Break Alarm 2 Alarm Relays 2 f g j 3 Alarm Relays 3 h o k HBA A e' p i' HBA + 1 Alarm Relay B g' j' HBA + 2 Alarm Relay C h' o' k' * HBA is available only in case OUT1=1 or OUT1=2.

Availability DC10 10 20 30 40 Table Transmitter None Selection 0 4-20 ma 1 0-20 ma 2 0-5 V A 0-10 V B 1-5 V C 2-10 V D Remote SP None _ 0 _ 4-20 ma _ 1 _ q l l l 0-20 ma _ 2 _ q l l l 0-5 V _ A _ q l l l 0-10 V _ B _ q l l l 1-5 V _ C _ q l l l 2-10 V _ D _ q l l l Communication None 0 RS-232 1 m n RS-485 2 m n RS-232 (Modbus RTU) A m n RS-485 (Modbus RTU) B m n TABLE I Manual English E Chinese C French F Korean K RESTRICTIONS / NOTES Restriction Available Only With Not Available With Letter Table Selection Table Selection b X c I _ 0 1, _ 0 2 d I & DC10 - _ 0 1 - _ 0 _ - _ e, e' I & DC10 - _ X _ - 1 - _ DC10 - _ X _ - A - _ e' I _ X _ f 0 _ 0 g, g' I & DC10 - _ X _ - X - _ X X _ g' _ X _ h,h' I & DC10 - _ 0 _ - 0 _ 0 - _ h' _ X _ i, i' I & DC10 - _ X _ - _ X _ - _ i' X _ X j, j' I & DC10 - _ 0 _ - _ 0 _ - _ j' X _ X k, k' I _ 0 _ k' _ X _ l I DC10 P _ A, B, C m X n X X _ o, o' _ 0 _ o' I & DC10 - _ 0 _ - 0 - _ p _ X _ q I 1, _ 0 _2 I & DC10 P_ 0 _ B

Model Interpretation DC105_,DC106_ DC1000 Digital Controller Instructions Select the desired Key Number. The arrow to the right marks the selections available. Make one selection each from Tables I through I using the column below the proper arrow. A dot ( ) denotes unrestricted availability. A letter denotes restricted availability. Key Numbers I I DC10 - _ - _ - _ KEY NUMBER Description Selection Size DIN RAIL Attachment DC105 _ DIN RAIL Attachment(Economic) DC106 _ Availability Power & Approvals 90-240 Vac Power / CE DC10_0-50 Vdc Power / CE DC10_1 b b Program None DC10 C_ Program (2 patterns, 8 segments per 1 pattern) DC10 P_ Input RTD DC10 _R TC DC10 _T Linear DC10 _L TABLE I Control Output 1 None 0 Relay, Contact, SPDT, 3A / 240 VAC 1 Volt, Voltage Pulse, 20VDC / 20 ma 2 ma Current, 4-20mA 3 Three Position Step Motor Control c 0-5 V A 0-10 V B 1-5 V C 2-10 V D Control Output 2 None _ 0 _ (Heat/Cool) Relay, Contact, SPDT, 3A / 240VAC _ 1 _ Volt, Voltage Pulse, 20VDC / 20mA _ 2 _ ma Current, 4-20mA _ 3 _ 0-5V _ A _ 0-10V _ B _ 1-5V _ C _ 2-10V _ D _ Alarm Event 1 Alarm Relay 1 e & Heat Break Alarm 2 Alarm Relays 2 f g HBA A h p * HBA is available only in case OUT1=1 or OUT1=2.

Availabil DC10 50 60 Table Transmitter None Selection 0 4-20 ma 1 0-20 ma 2 0-5 V A 0-10 V B 1-5 V C 2-10 V D Remote SP None _ 0 _ 4-20 ma _ 1 _ q l 0-20 ma _ 2 _ q l 0-5 V _ A _ q l 0-10 V _ B _ q l 1-5 V _ C _ q l 2-10 V _ D _ q l Communication None 0 RS-232 1 m n RS-485 2 m n RS-232 (Modbus RTU) A m n RS-485 (Modbus RTU) B m n TABLE I Manual English E Chinese C French F Korean K Accessory DC1050-OPTOOL- Operation Tool Panel (Cable Length=50cm, 19.68in) EP RESTRICTIONS / NOTES Restriction Available Only With Not Available With Letter Table Selection Table Selection b c I _ 0 1, _ 0 2 d e - - Configuration Tool K A 3 0 1 I & I DC10 - _ 0 1 - _ 0 _ - 0 _ X f I _ 0 _ g I X or _ X _ h I _ 0 X _ l I DC10 P _ A, B m X n X X _ p _ X _ q I 1, _ 0 2 I & DC10 P_ 0 _ B I A, B

Warranty / Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications are subject to change without notice. Honeywell Process Solution Field Products Honeywell Building 1 Changi Business Park Central 1 Singapore 48603 www.honeywell.com/