User s manual TPM-RKE Analyzer 9936 Version Daimler Chrysler

Similar documents
System Requirements: D-Link Systems, Inc.

USER MANUAL. Sens it SENS IT 2.4

USER MANUAL MODEL: BM-162

CCR24T CCR24R. User s Guide WIRELESS TRANSMITTER SYSTEM WARRANTY SERVICE CARD WARRANTY CARD

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.

Technical Description

Focus Iris Manual Ver 1.1

Radio Micro Force Manual v1.1

CRUX II/BTGPS USER GUIDE. Model:D1598

Disclaimers. Important Notice

Manual Unihan UPWL6025

Hi-Fi Shelf System *MFL * SIMPLE MANUAL

Innovation First, Inc. RS MHz Robot Controller User Manual

Mini Hi-Fi Audio *MFL * SIMPLE MANUAL

Quick Start Guide. Antenna Alignment Tool AIMWLLR0-35. QSG rev 7 AIMWLLR0-35 [NRB-0200] QSG.indd 1

WIRELESS BARCODE SCANNER. User Guide.

Wireless TFT LCD Monitor

WVP. Wireless Valve Programmer. Programmer for use with WVC Multi-Station Battery Powered Irrigation Controllers

Mini Hi-Fi Audio *MFL * SIMPLE MANUAL

ON!Track smart tag AI T380. English. Printed: Doc-Nr: PUB / / 000 / 02

Schwinn MPower Echelon Console + Power

Super Switch Indoor Wireless Remote Control Wall Outlets

Manual Unihan UPWL6580

Wireless AC Circuit Identifier

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

Schlage Control Smart Locks

Manual Unihan UPWL6024

Instruction Manual. for Media Monkey. 1

Interface Manual Tank Level Float Stick System

802.11n, 2.4G 1T1R Wireless LAN PCI Express Half Mini Card

Blue Point Engineering

Model: WS-7014CH-IT Instruction Manual DC: WIRELESS FORECAST STATION

MPRF01 Wireless 5uA Inductive Proximity Sensor RF System

ORiNOCO AP-4000MR-LR and AP-4900MR-LR Access Points Safety and Regulatory Compliance Information

Wireless Rain Station

User Manual. Product Name:tablet Model Name:TM800A740M Brand Name:NuVision. Manufacture:Shenzhen Vastking Electronic Co.,LTD.

Firmware version 1.05 supports all CMOS sensor based digital backs IQ150, IQ250 and A- series IQ250.

Operating Distance An operating distance (in conjunction with our GLR27 series receivers) of 350 metres is possible.

Mini Hi-Fi System *MFL * SIMPLE MANUAL

TVT280 Visual IR Thermometer Operation Flow (rev 0.5)

USB RX Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso

Keycards come with an imbedded RFID chip and antenna, there is no battery in the keycards. The keycards are encrypted and only

Radio Link Starter Kit

HY737 Walkie talkie for kids

Blue Point Engineering Inc.

RF (RADIO FREQUENCY) WIRELESS PENDANT

Radio Link Starter Kit

Operating Manual LITEMASTER PRO L-478DR-PX L-478DR-A-PX L-478DR-U-PX. Light Meter

Enphase. Mobile Connect Installation Guide

12V Victor 888 User Manual

Operating Manual LITEMASTER PRO L-478DR L-478DR-A L-478DR-U. Light Meter

FM RADIO TRANSMITTER

OPERATION MANUAL WARNING

SP GHz Digital Wireless Speakers. User s Manual. Please read before using the equipment. Please visit for details.

R PROFLAME Instruction Book Collection

RQT-xxx-RCVR Owner s Manual Quick Talk TM Wireless Voice Monitor & Alarm transmitter with factory installed MHz Keyfob Receiver

Wireless SingStar Microphone Instruction Manual

X2 SLIM USER S MANUAL

900 MHz Digital Wireless Indoor/Outdoor Speakers

IS7705. Installation & Operation Manual AUDIO INTEGRATION KIT. TranzIt LINK

Quick Guide. FCC/IC: MHz CE: MHz

Combo Scanner. User Manual

YDL100SF USER M A N U A L. Smart-Ashley. Smart-Ashley. Y D L S F N a m e and C a u t i o n. A u t u e n t i c a t i o n T y p e

Visit TheNewInstant.com for additional information, including high-res images. Quick-Start Guide

LOUIS VUITTON 1. Louis Vuitton Echo, locate your Horizon luggage in airports Battery indicator light. Light sensor to detect opening

fast facts & faqs wireless communication C Phicom Pty Ltd 2008

UHF Wireless Transmitter

23070 / Digital Camera Owner s Manual

CarConnect Bluetooth Interface General Motors Owner s Manual

Ambient Weather F007TP 8-Channel Wireless Probe Thermometer User Manual

GPS&GPRS TRACKING SYSTEM GT3100

Door/Window Sensor User Manual HKWL DWS02W

OEM KEYFOB TRANSMITTER DATA GUIDE

Users Manual AgCam /EnduraCam TM

Table of Contents. Mounting Diagram.. Wiring Information.. Setting the STR 1000 as a Repeater or a Transmitter. STR 1000 Frequently Asked Questions..

User Manual Information and Product Description. of the. Flap Key Family BOSCH. with Chevy, GMC and GM Logo

Transponder Reader TWN4 MultiTech 3 Quick Start Guide

IS76 Beacon with Ferrite Antenna Installation Manual

User s Guide FM Transmitter

Learn and Discover Driver

SolarEdge Export Limitation Application Note

Mag 3/6 System. Manual.

User Manual Digital Wireless Rain Gauge

INSTALLATION MANUAL FOR SAL SERIES WIRELESS CLOCKS SPECIFICATIONS

WPR400 Wireless Portable Reader

Supplement. ScanMaker s450/s350 features, scenarios, and information. Getting to Know Your ScanMaker s450/s350

TARGETuner Antenna Management System for Screwdriver Antennas

User's Guide. Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth. Model MO297

Disclaimers. Important Notice

Learn & Go. User s Manual. c 2013 VTech Printed in China US

TONE ALERT RECEIVER MODEL 2TR9A. P.O. Box West Pacific. Lexington, NE 68850

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

Ambient Weather F007TH Wireless Thermo-Hygrometer User Manual

NEO CAR AUDIO. Neo AUXiN AUX INPUT INTERFACE. Instruction Manual

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

HORNET Remote Control Systems

Thermo Plus Bluetooth-enabled Thermo-Hygro Monitor Model: RAR213HG USER MANUAL

Supplement. ScanMaker s480/s380 features, scenarios, and information. Getting to Know Your ScanMaker s480/s380

Do not expose this device to water or moisture of any kind. Do not mix new and old batteries or batteries of different types.

Product Manual. Getting Started with Roadie 2.

Transcription:

User s manual TPM-RKE Analyzer 9936 ersion 06.03 Daimler Chrysler Reference: QS-258DCA-U

User guide REGULATORY STATEMENTS This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions; (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the manufacture could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/t technician for help. WARNING: Changes or modifications not expressly approved by the manufacturer may violate the user's authority to operate the equipment. Industries Canada: The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada s website www.hc-sc.gc.ca/rpb"

User s Manual TABLE OF CONTENTS User guide 2 TPM-RKE ANALYZER 9936... 2.1 DESCRIPTION OF THE TPM-RKE ANALYZER 9936... 2.2 FEATURES... 3..1 Radio frequencies... 3..2 Type of valve... 3.3 CONNECTORS... 4..1 Supply connector... 4..2 USB connector... 4..3 RS232 connector... 4.4 DESCRIPTION OF THE INSTRUMENT... 5..1 Power on/off key... 5.5 FRONT PANEL DESCRIPTION... 6..1 Display... 6..2 Lights... 6..3 Keys... 6.6 BATTERY SUPPLY... 7..1 Battery status... 7.7 MEASUREMENT... 8..1 Key measurement (RKE test)... 8..2 alve measurement (TPM functions)... 9.8... 12..1 Parameters menu... 12.9 STARSCAN... 16..1 Data transfer... 16..2 TPM/RKE Analyzer program up-dating... 16.10 MENU STRUCTURE... 17..1 Main menu... 17.11 CORRESPONDANCES TABLES... 19..1 ehicle / Body / valve... 19..2 Countries / frequencies... 19... 19 Index 20 User guide TPM-RKE Analyzer Page 1/20

User guide TPM-RKE ANALYZER 9936.1 DESCRIPTION OF THE TPM-RKE ANALYZER 9936 The principal of this instrument is to awaken and then retrieve data from smart valves mounted on vehicle wheels in order to verify their identifiers. The instrument interacts with the smart valves without contact through wireless communication. LCD Display Light Indicators Keypad RS232 (RJ45) Connecter USB Connecter User guide TPM-RKE Analyzer Page 2/20

.2 FEATURES..1 RADIO FREQUENCIES Awakening transmission frequency: 125 khz (LF). Reception frequencies: 433 MHz or 315 MHz (RF)...2 TYPE OF ALE This instrument is especially designed for the measurement of the Siemens and Schrader valves installed into Daimler-Chrysler vehicles. Siemens Siemens Schrader User guide TPM-RKE Analyzer Page 3/20

.3 CONNECTORS..1 SUPPLY CONNECTOR To supply the instrument and recharging the internal battery. The voltage of the charger is a 24 DC...2 USB CONNECTOR The USB connector allows the instrument software programs to be updated. StarScan tool can retrieve information through the USB connector...3 RS232 CONNECTOR Not used. User guide TPM-RKE Analyzer Page 4/20

.4 DESCRIPTION OF THE INSTRUMENT..1 POWER ON/OFF KEY KEY FUNCTION Power on: Press this key to power on the instrument. Power off: Press and hold the key (more than 3 seconds) to power off the instrument...1. Power on At power on, it displays the logo. Then it displays the software revision number. ATEQ T 60 ersion 06.03 Then the tool displays the main menu and the operator can select desired function. > RKE TEST User guide TPM-RKE Analyzer Page 5/20

.5 FRONT PANEL DESCRIPTION..1 DISPLAY The LCD screen displays the parameters menus and the measurements results. > RKE TEST..2 LIGHTS LOW BAT Battery level light: When this light is on, the battery level is too low, charge it. PASS Pass test light: When this light is on, the instrument has correctly received the frame from the valve (or the RKE). FAIL Fail test light: When this light is on, the instrument has not received the frame from the valve (or the RKE). TX Transmission light: When this light is flashing, the instrument is currently transmitting a 125 KHz frequency to activate a valve. CHARGE Battery charging light: This light turns on when the instrument is being charged...3 KEYS Power on and off the instrument. Navigation menu, "up". Navigation menu, "down". Select Key, press to enter in the chosen function or validate a parameter. Cancel key, return to the previous menu or function without parameter validation. Test Key, to initiate a test cycle. User guide TPM-RKE Analyzer Page 6/20

.6 BATTERY SUPPLY The instrument uses a Li-ion battery, the autonomy depends of the number of cycles carried out. It battery must be recharged with a 24 DC external power supply (Included)...1 BATTERY STATUS When the battery is too low, the "LOW BATT" light is flashing for 2 seconds and the instrument will powered off. LOW BATT PASS FAIL TX To see the battery status, select the "" menu using the and keys. alidate your entry with the RKE TEST > By using the and keys, select the "BATTERY LEEL" menu and validate with the PARAMETERS MENU UNIT : METRIC AUTO OFF: DISABLE > BATTERY LEEL The instrument displays the receivers and the battery status. RECEIER 1: READY 2: READY BATTERY Press the button to return to the main menu. > RKE TEST User guide TPM-RKE Analyzer Page 7/20

.7 MEASUREMENT..1 KEY MEASUREMENT (RKE TEST) This menu allows putting the instrument in key test mode (RKE). > RKE TEST Select this mode with the key, the instrument invites you to launch the test by pressing the EUROPE RKE TEST < TEST > TO START Wait a second for the initialization if the instrument. EUROPE 1997/E RF LEEL PLEASE WAIT... The instrument displays a horizontal bar and invites you to test the key fob. Hold the key fob near the antenna of the instrument (between 7 and 15 centimetres) and press any button of the key fob. The intensity of the RF signal force is indicated on the scale of the horizontal bar. The greater the key fob RF signal power, the greater the horizontal bar is filled. EUROPE RKE TEST PRESS KEY FOB BUTTON EUROPE RKE TEST PRESS KEY FOB BUTTON Press the button to return to the main menu. > RKE TEST User guide TPM-RKE Analyzer Page 8/20

..2 ALE MEASUREMENT () Use the following directions to test the functionality of a TPM sensor: Select "TPM FUNCTION" by using the keys and validate using the and RKE TEST > By using the and keys, select the model year of the valve to be tested and validate using the key (existing years from 1997 to 2006). MODEL YEAR SELECTION > 1997 1998 1999 MODEL YEAR SELECTION 2004 2005 > 2006... Next, by using the and keys, select the body code of the valve to be tested and validate with the key (this code is in correspondence with a vehicle). > CS HB KJ BODY STYLE SELECTION BODY STYLE SELECTION LX RS > WK Next, by using the and keys, select the trigger selection and validate using the key (you may select the mode you want to trigger on the valve, read, park, deactivation and sniffing). Then the instrument is displaying the valve characteristics chosen and waiting for a start cycle. To start cycle, press the TRIGGER SELECTION > READ SENSOR PARK SENSOR DEACTIATE SENSOR EUROPE 2006.../WK PARK SENSOR < TEST > TO START User guide TPM-RKE Analyzer Page 9/20

LOW BATT PASS FAIL TX When the "TX" light is flashing, it indicates that the instrument is emitting a frame wirelessly to make the valve respond. EUROPE 2006.../WK PARK SENSOR TRIGGER PROCESSING First case: a valve is detected: When the instrument has detected a frame from the valve, the "PASS" light is on and it displays the valve characteristics. NB: the identifier displayed on the screen must be the same as the one written on the valve. LOW BATT PASS FAIL TX SENSOR DATAS 80AA323B 240 KPa SLEEP MODE <SELECT>TIRE LOCATION To locate the valve on the car, press the SENSOR DATAS 80AA323B 240 KPa SLEEP MODE <SELECT>TIRE LOCATION Then select the valve wheel location and press the TIRE LOCATION > LEFT FRONT : EMPTY LEFT REAR1 : EMPTY LEFT REAR2 : EMPTY The instrument confirms the location of the valve. LEFT FRONT : STORED And indicates the location valve on the car. Second case: no valve is detected: After a few moments, if no valve frame is detected, the "FAIL" light is on, so start a new test. TIRE LOCATION > LEFT FRONT : OK LEFT REAR1 : EMPTY LEFT REAR2 : EMPTY LOW BATT PASS FAIL TX User guide TPM-RKE Analyzer Page 10/20

Press the button to return to the main menu. > RKE TEST..1. Results explanation The picture below is an example of a valve data communication result: alve identifier SENSOR DATAS 80AA323B 240 KPa SLEEP MODE <SELECT>TIRE LOCATION Tire internal pressure at sea level alve mode To locate the valve on the car..2. No valve response If the instrument doesn't receive any information from the valve or if the valve is not compatible with the parameters, after 36 seconds a time out on the instrument stops its cycle and the "FAIL" light is switched on. LOW BATT PASS FAIL TX User guide TPM-RKE Analyzer Page 11/20

.8..1 PARAMETERS MENU This menu will allow the instrument to be configured according to the operator preferences...1. Country The parameter "COUNTRY" allows the user to select the geographic valves region. Select "" by using the keys and validate with the and RKE TEST > Select the "COUNTRY" parameter and validate with the Then select the valve region between US/CAN/MEX, JAPAN, MIDDLE EAST, EUROPE and OTHER. NB: the TPM function is not available for the Japan country. PARAMETERS MENU > COUNTRY : EUROPE UNIT : METRIC AUTO OFF: DISABLE REGION SELECTION > US/CAN/MEX JAPAN MIDDLE EAST Press the button to return to the main menu. > RKE TEST User guide TPM-RKE Analyzer Page 12/20

..2. Unit The parameter "UNIT" allows the user to choose between the "METRIC" unit and the "US" unit. Select "" by using the keys and validate with the and RKE TEST > Select the "UNIT" parameter and validate with the Then select the unit between "US" and "METRIC" and validate with the PARAMETERS MENU COUNTRY : EUROPE > UNIT : METRIC AUTO OFF: DISABLE UNIT SELECTION US > METRIC Press the button to return to the main menu. > RKE TEST User guide TPM-RKE Analyzer Page 13/20

..3. Auto off The "AUTO OFF" setting allows the user to turn off the instrument automatically after a certain time without use. This is to save the battery before a recharge is required. Select "" by using the keys and validate with the and RKE TEST > Select the "AUTO OFF" parameter and validate with the The cursor position moves to the right of the screen and by using the and keys, choose the auto off time between "DISABLE" and 1 to 60 minutes, PARAMETERS MENU COUNTRY : EUROPE UNIT : METRIC > AUTO OFF: DISABLE PARAMETERS MENU COUNTRY : EUROPE UNIT : METRIC AUTO OFF: 5 mn < then validate with the Press the button to return to the main menu. > RKE TEST In the above example, after 5 minutes with no use, the instrument will switch off automatically. User guide TPM-RKE Analyzer Page 14/20

..4. Back light The "BACK LIGHT" menu allows the user to adjust the light intensity of the display. The back light increases the battery consumption. Select "" by using the keys and validate with the and RKE TEST > Select the "BACK LIGHT" parameter and validate with the PARAMETERS MENU AUTO OFF: DISABLE BATTERY LEEL > BACK LIGHT: 0 % The cursor position moves to the right of the screen and by using the and keys, adjust the back light intensity, choose between 1 to 100 percent by 1 percent increments, then validate with the PARAMETERS MENU COUNTRY : EUROPE UNIT : METRIC AUTO OFF: 5 mn < Press the button to return to the main menu. > RKE TEST User guide TPM-RKE Analyzer Page 15/20

.9 STARSCAN..1 DATA TRANSFER Data transfer from the TPM/RKE Analyzer 9936 instrument to the StarScan tool. Connect the USB cable from the TPM/RKE Analyzer 9936 instrument to the StarScan tool, then the StarScan tool recognizes the information to download automatically...2 TPM/RKE ANALYZER PROGRAM UP-DATING Connect the USB cable between the computer and the instrument, the USB drivers must be installed first. Press and hold the and the at the same time. NB: in case of error of manipulation, to exit from this BOOTSTRAP T60 4.11 USB.2.00 menu, press the When the USB cable is connected, "CONFIGURED" appears on the screen. BOOTSTRAP T60 4.11 USB.2.00 CONFIGURED On the computer open the attached file and a browser will appear. Click on "LOAD". The loading progress is displayed and when completed, the instrument will boot to the main menu. Now it's possible to disconnect the USB cable from the PC and the instrument. > RKE TEST User guide TPM-RKE Analyzer Page 16/20

.10 MENU STRUCTURE...1 Sub menu 1 Sub menu 2 Sub menu 3 Sub menu 4 RKE TEST > > RKE TEST Press <TEST> to start 1997 > 1998 > 1999 > 2000 > PR READ SENSOR > DEACTIATE SENSOR SNIFFING MODE 2001 > LH > PR > WJ READ SENSOR > DEACTIATE SENSOR SNIFFING MODE 2002 > LH > PR > RS > WJ > > READ SENSOR > DEACTIATE SENSOR SNIFFING MODE 2003 > CS > LH > RS > W J > ZB > READ SENSOR > DEACTIATE SENSOR SNIFFING MODE 2004 > CS > KJ > LH > RS > WJ > ZB > READ SENSOR > User guide TPM-RKE Analyzer Page 17/20

DEACTIATE SENSOR SNIFFING MODE 2005 > CS > KJ > RS > WK > ZB > READ SENSOR > PARK SENSOR > DEACTIATE SENSOR SNIFFING MODE 2006 > CS > HB > KJ > RS > WK > XK READ SENSOR > PARK SENSOR > > COUNTRY > US/CAN/MEX JAPAN MIDDLE EAST EUROPE OTHER UNIT > US AUTO OFF > BATTERY LEEL METRIC DISABLE > 1 to 60 min BACK LIGHT > 0 to 100 % DEACTIATE SENSOR SNIFFING MODE User guide TPM-RKE Analyzer Page 18/20

.11 CORRESPONDANCES TABLES..1 EHICLE / BODY / ALE ehicle line Body code Model year alve manufacturer Prowler PR 1997-2002 Schrader iper ZB 2003 - Present Schrader Intrepid/300M LH 2001-2004 Schrader Grand Cherokee WJ 2001-2004 Schrader Pacifica CS 2003.5-2004 Schrader Town & Country/Caravan RS 2002-2003 Schrader Town & Country/Caravan RS 2004-2005 Siemens Liberty KJ 2004 Siemens Liberty KJ 2005 - Present Siemens Commander XK 2006 - Present Siemens Pacifica CS 2005 - Present Siemens Town & Country/Caravan RS 2006 - Present Siemens Grand Cherokee WK 2005 - Present Siemens 300C/Magnum/Charger LX 2006 - Present Siemens Durango HB 2006 - Present Siemens..2 COUNTRIES / FREQUENCIES Country TPM frequencies (MHz) RKE frequencies (MHz) US / Canada / Mexico 315 315 Japan - 315 Middle east 315 433 Europe 433 433 Other 315 315 User guide TPM-RKE Analyzer Page 19/20

Index Auto off... 14 Back light... 15 Battery status... 7 Connectors... 4 Country... 12 Description... 2 Display... 6 Key fob... 8 Keys... 6 Lights indicator... 6 Measurement... 9 Measurements... 8 Menu structure... 17 No response... 11 Parameters menu... 12 Parameters setting... 12 Power on... 5 Radio frequencies... 3 RKE... 8 RS232 connectors... 4 StarScan tool... 16 Start... 5 Supply... 7 Supply connector... 4 Tables... 19 TPM... 9 Unit... 13 Up-dating... 16 USB connectors... 4 alves types... 3 Results explanation... 11 User guide TPM-RKE Analyzer Page 20/20