SGDV- 01 SGDV- 05. Analog Voltage/Pulse Train Reference Type SERVOPACKs. (For Rotary Servomotors) (For Linear Servomotors)

Similar documents
4th digit. 7th digit. digits. Specifications. Interface. MECHATROLINK-2 communications Reference Type (for rotary servomotors)

4th digit. 5th+6th digits. 7th digit. Specifications. 8th+9th+10th digits Options (hardware)* 4. Interface

(For Linear Servomotors) S G D V - R70 A 21 A th digit. 7th digit. 5th6th digits

SGDV- E5 (For Linear Servomotors)

(For Rotary Servomotors) (For Linear Servomotors) SGDV - R70 A 01 B Voltage Interface 100 VAC 200 VAC 400 VAC V (Three Phase)

SERIES PRODUCT CATALOG

Analog Voltage/Pulse Train Reference Type SERVOPACKs. (For Rotary Servomotors) (For Linear Servomotors) SGDV - R70 A 01 B

AC SERVO DRIVES SERIES. Servopacks. Certified for ISO9001 and ISO14001

(For Rotary Servomotors)

Analog Voltage Reference SERVOPACKs Pulse Train Reference SERVOPACKs. (Analog Voltage Reference) SGDV- EP1. (Pulse Train Reference)

Σ-V Series. USER'S MANUAL Design and Maintenance. AC Servodrive

Sigma-5 servo drive System configuration

Analog monitor cable. Filter Motion control unit. General purpose cable. (Refer to chapter Sigma-II rotary motors) Cables SGMGH, SGMUH, SGMSH, SGMBH

LARGE-CAPACITY SERIES

Σ-V Series. USER'S MANUAL Design and Maintenance. AC Servodrive

Σ-V Series. USER'S MANUAL Design and Maintenance Rotational Motor Command Option Attachable Type. AC Servo Drives

SGDH Amplifier. Part Number Guide. Quick Reference Guide. Amplifier: SGDH - 15 A E- Motor: SGMGH - 09 A C A 6 C $10

Copyright 2014 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or

DS2 series servo drive

SigmaLogic7 Compact Hardware Manual

New Servo Concept: Junma

USER S MANUAL Design and Maintenance

Σ-V Series. USER'S MANUAL Design and Maintenance Rotational Motor Command Option Attachable Type. AC Servo Drives

USER S MANUAL Design and Maintenance

USER'S MANUAL Design and Maintenance

Troubleshooting Alarm Displays Warning Displays

USER S MANUAL Design and Maintenance

Σ-V Series USER'S MANUAL Setup Rotational Motor

EDB series AC servo system

Troubleshooting Alarm Displays Warning Displays

SGMMV. Rotary Servomotors SGMMV - A1 A 2 A 2 1. Model Designations. 6th. 5th digit. 1st+2nd digits. 7th digit. 4th digit. 3rd digit.

Indexer unit JUSP-NS600. System configuration. Smart and simple positioning solution.

AC SERVO DRIVES JUNMA SERIES D E F I JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA

DS2 series 220V servo driver

Σ-V Series USER'S MANUAL Setup Rotational Motor

6th digit. 5th digit. 4th digit. Code Specifications 3 20-bit absolute (standard) D 20-bit incremental (standard) Design Revision Order

Sigma FSP Amplifier User s Manual

Installation Servo Drive Dimensions

Σ-V Series. USER'S MANUAL Operation of Digital Operator Model: JUSP-OP05A-1-E. AC Servo Drives. Introduction. Parameter/Monitor Modes

Build the machine you ve dreamed of, today!

XtraDrive (XD-) SERIES AC SERVO DRIVER

JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA AC SERVO DRIVES JUNMA SERIES. Goodwin Electronics: Tel: Web:

Troubleshooting Alarm Displays Warning Displays

PKG-EML10-EDB10-CBLS System Diagram and Specifications

G5 Series Servo System

Σ-V Series. USER'S MANUAL Design and Maintenance. AC Servo Drives. Linear Motor MECHATROLINK-II Communications Reference

2Encoder Cable Extension from 30 to 50 m. (Example) SGDV SERVOPACK. Servomotor. Main Circuit Cable SGMJV. Servomotor End CAUTION

USER S MANUAL For Use with Large-Capacity Models Design and Maintenance

USER S MANUAL Design and Maintenance

Series SGDH Indexer Application Module USER'S MANUAL

Σ-V Series. USER'S MANUAL Operation of Digital Operator. AC Servo Drives. Introduction. Parameter/Monitor Modes. Utility Function Mode

DS2 series servo drive

BLuAC5 Brushless Universal Servo Amplifier

Series SGDH Indexer Application Module USER'S MANUAL

SGMJV. Rotary Servomotors SGMJV - 01 A D A 2 1. Model Designations. 2Without Gears. 1st+2nd digits. 3rd digit. 5th digit. 6th digit.

BLuAC5 Brushless Universal Servo Amplifier

Single-phase or three phase AC220V (-15% ~ +10%) 50 ~ 60Hz

5th digit. 4th digit. 6th digit. Design Revision Order. Shaft End. Code Specifications

Cable connection. Sigma-II series SERVOPACK SGDH- 200V. Ver. Servo Drive CN3 (CN10) CN1 CN2 NS500 JUSP-NS500 SERVOPACK. 200V Ver.

CL86T. 24~80VDC, 8.2A Peak, Closed-loop, No Tuning. Descriptions. Closed-loop. Stepper. Applications. Datasheet of the Closed-loop Stepper CL86T

User Manual. Serial No. SC

30-80V, 8.2A Peak, No Tuning, Nulls loss of Synchronization

ES86 Series Closed-loop Stepper Drive + Motor System (Drive+ Motor/Encoder)

Yaskawa Electric Engineering Corporation AC SERVOPACK. EGSV3 Series. User s Manual EGSV3- Document No. ESI-M-005E <1>

AC SERVO DRIVES SERIES. Rotary Servomotors. Certified for ISO9001 and ISO14001

SERIES SGDH FULLY CLOSED INTERFACE UNIT USER'S MANUAL MODEL: JUSP-FC100

Series SGMBH/SGDH USER S MANUAL AC Servodrive (400 V, 22 to 55 kw) SGMBH Servomotor SGDH SERVOPACK

ES86 Series Closed-loop Stepper Drive + Motor System (Drive+ Motor/Encoder)

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

SD Series. AC Spindle Motor Drives with Power Regeneration, AC Servo Drives. Speed Reference with Analog Voltage Expanded Functions

AC Servo Motor Driver. LECYM Series

Proposing control by a hydraulic servo and V/F inverters

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

Cable connection. Sigma-II series SERVOPACK SGDH- 200V. Ver. Servo Drive CN3 (CN10) CN1 CN2 JUSP-NS500 NS500 SERVOPACK. 200V Ver.

Integrated servo motor

Inverter Drive /Vector Drive Motors & Controls

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

USER S MANUAL. AC Servo Drives -V Series / -V Series for Large-Capacity Models / -7 Series. Safety Module. Model: SGDV-OSA01A.

PRODUCT NOTE MOTION PRODUCT ENGINEERING GROUP

Cat. No. I806-E1-02. Replacement Set for S, R, and H Series

8V General information. 2 Order data 8V

Product Discontinuation Notices. Discontinuation Notice of AC Servomotors/drivers. OMNUC U series

1S servo drive System configuration

Driver Specification for Linear Motor Drive Tables

Resolution (divisions) 256, 360, , 360, 720, 1,024 Pre-wired Model

ies-2309 Integrated Easy Servo

Integrated Easy Servo

Specifications of ASDA A2-E_220V Series

RDV-X/RDV-P Robot driver Only for pulse train control

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

AD Series. AC Servo Drive. For the highest requirements in performance and precision

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

1S servo drive System configuration

For more information on these functions and others please refer to the PRONET-E User s Manual.

EDC Series AC servo system

USER S MANUAL. OMNUC U SERIES MODELS R88M-U (AC Servo Motors) MODELS R88D-UT (AC Servo Drivers) AC SERVO MOTORS/DRIVERS (1 to 5 kw)

Servo Motor Driver. 4. Specifications: Digital Driver Model ACS806. Digital Technology, max. 80 V DC / 6.0 A, W. 1. Product Description:

Power supply voltage Output configuration Output code Resolution (pulses/rotation) Connection method Model

ES86 Series Closed-loop Stepper Drive + Motor System (ES-D808 Drive+ Motor/Encoder)

VF-nC1 Adjustable Speed Drive Engineering Specification

Transcription:

Analog Voltage/Pulse Train Reference Type PACKs SGDV- 0 (For Rotary Servomotors) SGDV- 0 (For Linear Servomotors) Model Designations S G D V - R70 A 0 A 000 00 0 v Series SGDV PACK st+nd+ rd digits th digit th+6th digits 7th digit 8th+9th+ 0th digits th+th digits th digit 9 st+nd+rd digits Current Voltage Code Applicable Servomotor Max. Capacity kw Singlephase 00 V Threephase 00 V Threephase 00 V R70 0.0 R90 0. R 0. R8 0. R70 0.0 R90 0. R6 0. R8 0. R8 0. R 0.7 7R6.0 0. 80.0 00.0 0.0 70 6.0 0 7. 90 780 R9 0. R.0 R. 8R.0 0.0 70.0 0 6.0 60 7. 80 70 th digit Power Supply Voltage Code F A D th+6th digits Code 0 0 Single-phase 00 VAC Three-phase 00 VAC Three-phase 00 VAC Interface Analog voltage/pulse train reference type (for rotary servomotors) Analog voltage/pulse train reference type (for linear servomotors) 7th digit Design Revision Order A, B 8th+9th+0th digits Code 000 Base-mounted (standard) 00 Rack-mounted 00 Varnished 00 Rack-mounted and Varnished 008 th+th digits Options (software) Code 00 Standard th digit Options (parameter) Code Single-phase 00 VAC input Model: SGDV-0A0A008000 00 Dynamic brake (00 V PACKs only ) 0 Standard Options (hardware) : These amplifiers can be powered with single or three-phase. : Single-phase 00 VAC PACKs are also available. (Model: SGDV-0A0A008000) : PACKs of 6 kw or more are duct-ventilated. : Multiple codes can be selected, but some combinations are not possible. Note: If the option codes digits 8 to are all zeros, they are omitted.

SGLGW Features Unprecedented ease-of-use through cutting-edge technology New tuning-less function means no adjustment needed. Impressive load regulation with strengthened vibration suppression function. Slashed setup time Setup wizard function and wiring conformation function of engineering tool SigmaWin+ allows easy setup just by watching the monitor. High response characteristics at khz min. New advanced autotuning. uced positioning time through model following control, and smooth machine control enabled by vibration suppression function. Ratings Single-phase 00 V PACK Model SGDV- R70F R90F RF R8F Applicable Servomotor Max. Capacity kw 0.0 0. 0. 0. Continuous Output Current Arms 0.66 0.9..8 Max. Output Current Arms..9 6. 9. Regenerative Resistors None or external Main Circuit Single-phase 00 to VAC+0% to -% 0/60 Hz Control Circuit Single-phase 00 to VAC+0% to -% 0/60 Hz Three-phase 00 V : The rated voltage is 0 to 0 VAC for the SGDV-0A0A008000 PACK. PACK Model SGDV- R70A R90A R6A R8A R8A RA 7R6A 0A 80A 00A 0A 70A 0A 90A 780A Applicable Servomotor Max. Capacity kw 0.0 0. 0. 0. 0. 0.7.0..0.0.0 6 7. Continuous Output Current Arms 0.66 0.9.6.8.8. 7.6.6 8. 9.6.9 6.9.7 8.6 78 Max. Output Current Arms..9.8 9. 6.9 7 8 6 8 0 0 0 70 Regenerative Resistors None or external Built-in or external External Main Circuit Three-phase 00 to 0 VAC+0% to -% 0/60 Hz Control Circuit Single-phase 00 to 0 VAC+0% to -% 0/60 Hz Three-phase 00 V PACK Model SGDV- R9D RD RD 8RD 0D 70D 0D 60D 80D 70D Applicable Servomotor Max. Capacity kw 0..0..0.0.0 6 7. Continuous Output Current Arms.9.. 8..9 6. 0.8.7 8. 7. Max. Output Current Arms. 8. 0 8 6 70 8 Regenerative Resistors Built-in or external External Main Circuit Three-phase 80 to 80 VAC+0% to -% 0/60 Hz Control Circuit VDC ±% Note: The entire over voltage category is. PACK Overload Characteristics Detecting time (s) 0000 000 00 0 SGMJV 00 00 00 0 Torque reference(percent of rated torque) (%) Detecting time (s) 0000 000 00 0 SGMAV-0, 0, 06, 08 0 SGMPS SGMAV-A, 0, C 00 00 00 Torque reference(percent of rated torque) (%) Note: Overload characteristics shown above do not guarantee continuous duty of 00% or more output. Use a servomotor with effective torque within the continuous duty zone of Torque-Motor Speed Characteristics. : The dotted line indicates the characteristics of a combination of SGDV-00A PACKs and SGMGV-0A servomotors. Single-phase 00 V PACK Model SGDV- R70A R90A R6A R8A RA 0A Applicable Servomotor Max. Capacity kw 0.0 0. 0. 0. 0.7. Continuous Output Current Arms 0.66 0.9.6.8..6 Max. Output Current Arms..9.8 9. 6.9 8 Regenerative Resistors None or external Built-in or external Main Circuit Single-phase 00 to 0 VAC+0% to -% 0/60 Hz Control Circuit Single-phase 00 to 0 VAC+0% to -% 0/60 Hz Detecting time (s) 0000 000 00 0 SGMGV-A, -A, -7A 80% torque Rated Approx. (percent of torque rated torque) SGMGV-0A, -0A, -09A, -A -0A, -0A, -AA, -EA SGMGV- D SGMSV- Rated torque + Max. torque Max. torque Analog/Pulse Type PACKs 60

6 Items Control Method : Speed regulation is defined as follows: Speed regulation= No-load motor speed Total load motor speed 00% Rated motor speed The motor speed may change due to voltage fluctuation or temperature fluctuation. The ratio of speed changes to the rated speed represent speed regulation due to voltage and temperature fluctuations. : Perform risk assessment for the system and confirm that the safety requirements for the standards are fulfilled before using the HWBB function. Feedback Operating Conditions Applicable Standards Mounting Performance Communications Display Analog Monitor Dynamic Brake (DB) Rotary Servomotors With Linear Servomotors Ambient Temperature Storage Temperature Ambient Humidity IGBT PWM control, sine-wave driven Serial encoder: -bit (incremental encoder) : 7-bit (incremental/absolute encoder) : 0-bit (incremental/absolute encoder) Absolute linear scale (The signal resolution varies depending on the absolute linear scale.) Incremental linear scale (The signal resolution varies depending on the incremental linear scale or serial converter unit.) 0 to + C 0 to +8 C 90%RH or less Storage Humidity 90%RH or less Vibration Resistance.9 m/s Shock Resistance 9.6 m/s Protection Class Pollution Degree Altitude Others Speed Control Range Speed Regulation Regenerative Processing Overtravelling (OT) Prevention Protective Functions Utility Functions Safety Functions Option Module Load Fluctuation Voltage Fluctuation Temperature Fluctuation IP0 000 m or less With no freezing or condensation An environment that satisfies the following conditions. Free of corrosive or flammable gases Free of exposure to water, oil, or chemicals Free of dust, salts, or iron dust Do not use PACKs in the following locations: Locations subject to static electricity noise, strong electromagnetic/magnetic fields, radioactivity UL08C (E78) EN078, EN0/A group classa, EN6000-6-, EN6800-, EN6800--, EN9-, IEC608- to Standard: Base-mounted Optional: Rack-mounted, Duct-ventilated :000 (The lower limit of the speed control range must be lower than the point at which the rated torque does not cause the servomotor to stop.) 0% to 00% load: ±0.0% max. (at rated speed) Rated voltage: ±0% : 0% (at rated speed) ± C : ±0.% max. (at rated speed) Torque Control Tolerance (Repeatability) ± % Soft Start Time Setting 0 to 0 s (can be set individually for acceleration and deceleration.) Interface Digital operator (JUSP-OP0A--E), personal computer (can be connected with SigmaWin+) RS-A :N communications RS-A port: N= max. available Communications Axis address setting Set by parameters USB Interface Personal computer (can be connected with SigmaWin+.) Communications Communications Standard Compliant with USB. standard ( Mbps) CHARGE indicator Number of points: Output voltage: ±0 VDC (linearity effective range ±8 V) Resolution: 6 bit Accuracy: ±0 mv (Typ) Max. output current: ±0 ma Settling time (±%):. ms (Typ) Input Output Applicable Standards Activated when a servo alarm or overtravelling (OT) occurs, or when the power supply for the main circuit or servomotor is OFF. Included For more information, refer to the previous page. Dynamic brake stop at P-OT or N-OT, deceleration to a stop, or free run to a stop Overcurrent, Overvoltage, low voltage, overload, regeneration error, etc. Gain adjustment, alarm history, JOG operation, origin search, etc. /HWBB, /HWBB: Baseblock signal for power module EDM: Status monitor (fixed output) of built-in safety circuit EN9 category IEC608 SIL Fully-closed Module

Analog/Pulse Type PACKs SGDV- 0/0 Rotary Servomotors Items I/O Signal Panel Operator Torque Control Speed Control Position Control Encoder Output Pulses Sequence Input Sequence Output Input Signals Soft Start Time Setting Input Signals Internal Set Speed Control Fixed Input Input Signals which can be allocated Fixed Output Output Signals which can be allocated Display Unit Switch Reference Voltage Input Impedance Circuit Time Constant Reference Voltage Input Impedance Circuit Time Constant Rotation Direction Selection Speed Selection Phase A, phase B, phase C: line driver output The number of dividing pulse: Any setting ratio is available. SEN signal Number of Channels Functions 7 channels Servo ON (/S-ON) Internal set speed selection (/SPD-D, /SPD-A, /SPD-B) Proportional control (/P-CON) Forward run prohibited (P-OT), reverse run prohibited (N-OT) Control selection (/C-SEL) Zero clamping (/ZCLAMP) Alarm reset (/ALM-RST) Reference pulse inhibit (/INHIBIT) Forward external torque limit (/P-CL), reverse external torque limit (/N-CL) Gain selection (/G-SEL) Positive and negative logic can be changed. Servo alarm (ALM), alarm code (ALO, ALO, ALO) outputs Number of channels Channels Positioning completion (/COIN) Speed limit detection (/VLT) Speed coincidence detection (/V-CMP) Brake (/BK) Rotation detection (/TGON) Functions Warning (/WARN) Servo ready (/S-RDY) Near (/NEAR) Torque limit detection (/CLT) Positive and negative logic can be changed. Five 7-segment LEDs Four push switches Max. input voltage: ± V (forward torque reference with positive reference) Factory setting: VDC at rated torque (Input gain setting can be changed.) About kω 6 μs 0 to 0 s (can be set individually for acceleration and deceleration.) Max. input voltage: ± V (forward speed reference with positive reference) Factory setting: 6 VDC at rated speed (Input gain setting can be changed.) About kω 0 μs With P control signal With forward/reverse external torque limit signal (speed to selection). Servomotor stops or another control method is used when both are OFF. Feedforward Compensation 0 to 00% Positioning Completed Width Setting 0 to 0778 reference units Type Select one of them: Sign + pulse train, CW + CCW pulse train, or two-phase pulse train with 90 phase differential Input Signals Reference Pulse Form Max. Input Pulse Frequency For line driver, open collector Line driver Sign + pulse train, CW + CCW pulse train: Mpps Two-phase pulse train with 90 phase differential: Mpps Open Collector Sign + pulse train, CW + CCW pulse train: 00 kpps Two-phase pulse train with 90 phase differential: 00 kpps Position error clear Clear Signal For line driver, open collector : If the maximum reference frequency exceeds Mpps, use a shielded cable for I/O signals and ground both ends of the shield. Connect the shield at the PACK to the connector shell. Analog/Pulse Type PACKs 6

Linear Servomotors Items I/O Signal Panel Operator Force Control Speed Control Position Control Encoder Output Pulses Sequence Input Sequence Output Input Signals Soft Start Time Setting Input Signals Internal Set Speed Control Fixed Input Input Signals which can be allocated Fixed Output Output Signals which can be allocated Display Unit Switch Reference Voltage Input Impedance Circuit Time Constant Reference Voltage Input Impedance Circuit Time Constant Movement Direction Selection Speed Selection Phase A, phase B, phase C: line driver output The number of dividing pulse: Any setting ratio is available. SEN signal Number of 7 channels Channels Servo ON (/S-ON) Internal set speed selection (/SPD-D, /SPD-A, /SPD-B) Proportional control (/P-CON) Forward run prohibited (P-OT) Reverse run prohibited (N-OT) Control selection (/C-SEL) Zero clamping (/ZCLAMP) Functions Alarm reset (/ALM-RST) Reference pulse inhibit (/INHIBIT) Forward external force limit (/P-CL), Reverse external force limit (/N-CL) Gain selection (/G-SEL) Polarity detection (P-DET) Positive and negative logic can be changed. Servo alarm (ALM), alarm code (ALO, ALO, ALO) outputs Number of channels Channels Functions Five 7-segment LEDs Four push switches Feedforward Compensation 0 to 00% Positioning Completed Width Setting 0 to 0778 reference units Input Signals Reference Pulse Type Form Max. Input Pulse Frequency Positioning completion (/COIN) Speed limit detection (/VLT) Speed coincidence detection (/V-CMP) Brake (/BK) Servomotor movement detection (/TGON) Warning (/WARN) Servo ready (/S-RDY) Near (/NEAR) Force limit detection (/CLT) Positive and negative logic can be changed. Max. input voltage: ± V (forward force reference with positive reference) Factory setting: VDC at rated force (Input gain setting can be changed.) About kω 6 μs 0 to 0 s (can be set individually for acceleration and deceleration.) Max. input voltage: ± V (forward speed reference with positive reference) Factory setting: 6 VDC at rated speed (Input gain setting can be changed.) About kω 0 μs With P control signal With forward/reverse external force limit signal (speed to selection). Servomotor stops or another control method is used when both are OFF. Select one of them: Sign + pulse train, forward + reverse pulse train, two-phase pulse train with 90 phase differential For line driver, open collector Line driver Sign + pulse train, forward + reverse pulse train: Mpps Two-phase pulse train with 90 phase differential: Mpps Open Collector Sign + pulse train, forward + reverse pulse train: 00 kpps Two-phase pulse train with 90 phase differential: 00 kpps Position error clear Clear Signal For line driver, open collector : If the maximum reference frequency exceeds Mpps, use a shielded cable for I/O signals and ground both ends of the shield. Connect the shield at the PACK to the connector shell. 6

Analog/Pulse Type PACKs SGDV- 0/0 Power Supply Capacities and Power Losses The following table shows PACK's power supply capacities and power losses at the rated output. Main Circuit Power Supply Signal-phase 00 V Single-phase 00 V Three-phase 00 V Three-phase 00 V Applicable Servomotor Max. Capacity kw PACK Model SGDV- Power Supply Capacity kva Output Current : For the optional JUSP-RA0-E regenerative resistor unit. : For the optional JUSP-RA0-E regenerative resistor unit. : For the optional JUSP-RA8-E regenerative resistor unit : For the optional JUSP-RA9-E regenerative resistor unit. Notes: SGDV-R70F, -R90F, -RF, -R8F, -R70A, -R90A, -R6A, and -R8A PACKs do not have built-in regenerative resistors. If the regenerative energy exceeds the specified value, connect an external regenerative resistor (optional). SGDV-70A, -0A, -90A, -780A, -0D, -60D, -80D, -70D PACKs do not have built-in regenerative resistors. Be sure to connect a regenerative resistor unit (optional) or an external regenerative resistor (optional). For selection details, refer to page. Regenerative resistor power losses are allowable losses. Take the following action if this value is exceeded. Remove the lead or short bar that is short-circuiting the PACK main circuit terminal B and B. (SGDV-R8A, -RA, -7R6A, -0A, -80A, -00A, -0A, or 00-V class PACKs.) Install an external regenerative resistor (optional). For selection details, refer to page. Arms Main Circuit Power Loss 0.0 R70F 0. 0.66. W Regenerative Resistor Power Loss W Control Circuit Power Loss W Total Power Loss 0. R90F 0. 0.9 7.8.8 7 0. RF 0.7... 0. R8F..8.6.6 0.0 R70A 0. 0.66.. 0. R90A 0. 0.9 7.. 0. R6A 0.7.6.7 7 0.7 0. R8A..8.9.9 0.7 RA.9..7 8 77.7. 0A.6 68. 0 00. 0.0 R70A 0. 0.66.. 0. R90A 0. 0.9 7.. 0. R6A 0.6.6. 0. 0. R8A.8.0 7.0 0. R8A..8 0.. 0.7 RA.6..8 8 68.8.0 7R6A. 7.6.6 78.6. 0A..6 6.8 0 97.8.0 80A 8..9 9.9 6.0 00A.9 9.6.8 6..0 0A 7..9 6.7 6 7 6.7 6.0 70A 0.7 6.9 79. (80). 7. 0A.6.7 7.8 90.8 90A.7 8.6.7 (0) 79.7 8 780A 9.6 78 99.0 67.0 0. R9D..9.6 9.6.0 RD.. 6. 8.. RD.. 7. 06..0 8RD. 8. 77.9 0.9 8.0 0D 7..9 08.7 6.7.0 70D.7 6. 6. 6. 6.0 0D. 0.8 7.7 99.7 80 7 7. 60D..7 8.6.6 80D.9 8. 9.6.6 0 0 70D 0.6 7. 0.8.8 W. Analog/Pulse Type PACKs 6

REF YASKAWA DIGITAL OPERATOR REF ALARM SVON YASKAWA READ WRITE DIGITAL OPERATOR Selecting Cables Cables for CN CN CN CN7 CN8 (Analog Voltage/Pulse Train Reference Type PACKs) CN Cable for Analog Monitor CN Digital Operator Converter Cable Digital Operator CN7 Connection Cable for Personal Computer ALARM SVON CN Cable for I/O Signals READ WRITE Host Controller CN8 Cable for Safety Function Device Name Length Order No. Details Soldered Connector Kit JZSP-CSI9--E CN Cables for I/O Signals Connector Terminal Converter Unit 0. m JUSP-TA0PG-E m JUSP-TA0PG--E m JUSP-TA0PG--E Terminal Block and Connection Cable Cables with Loose Wires at One End m JZSP-CSI0--E m JZSP-CSI0--E m JZSP-CSI0--E Cable with Loose Wires at Peripheral Devices With Connection Cable ( m) Digital Operator JUSP-OP0A--E CN Cable with Connectors at Both Ends Digital Operator 0. m JZSP-CVS0-A-E Converter Cable JZSP-CVS0-A-E 0 CN7 Connection Cables for Personal Computer CN Cables for Analog Monitor Cable with Connectors at Both Ends. m JZSP-CVS06-0-E 6 JZSP-CVS06-0-E PACK End m JZSP-CA0-E 7 6 CN8 Cable for Safety Function Device Cables with Connector m JZSP-CVH0-0-E 8 Connector Kit Contact Tyco Electronics AMP K.K. Product name: Industrial Mini I/O D-shape Type Plug Connector Kit Model: 09- : A converter cable is required to use series digital operators (model: JUSP-OP0A) for series PACKs. : When using the safety function, connect this cable to the safety devices. Even when not using the safety function, use PACKs with the Safe Jumper Connector (model: JZSP-CVH0-E) connected. : Use the connector kit when you make cables yourself.

Analog/Pulse Type PACKs SGDV- 0/0 Selecting Cables () Connector Kit for CN Use the following connector and cable to assemble the cable. The CN connector kit includes one case and one connector. Connector Kit Case Connector Model Model Qty Model Qty JZSP-CSI9--E 00-Z0-008 set 00-000PE (Soldered) External Dimensions of Case (Units: mm) 9.0.8..0 7.0 6. 8. : Manufactured by Sumitomo M Ltd...7 Cable Size. Item Cable Applicable Wires Cable Finished Diameter Use twisted-pair or twisted-pair shielded wire. AWG 6 8 0 6 dia. max. External Dimensions of Connector (Units: mm)..7 Pin No.9 Pin No.6 Pin No.7 Pin No.0.. Pin No. Pin No. Pin No. Pin No..7.9 6.8 9. () Connector Terminal Converter Unit for CN Configurations External Dimensions of Terminal Block (Units: mm) PACK CN Cable Length 00 +0-0 mm 9. 7. Terminal Block (0P) Connector Plug (0P) 7 M. Screw MR-0RMDG+ 7 9. Pin No. Pin No.6.7 0.8 6.7 9. 6 0 9. Analog/Pulse Type PACKs 9 Model JUSP-TA0PG-E 6 0 9 0 -. Dia.. 7. Can be fixed on DIN rail 0 0... 6 With Terminal Block Cover Open External Dimensions of Cable (Units: mm) PACK End Connector (0P) 00-6000EL (Sumitomo M Ltd.) Shell 00-Z0-008 (Sumitomo M Ltd.) Cable () AWG#8, P UL076 VW-SC Terminal Converter Unit-end Connector (0P) MRP-0F0(Honda Tsushin Kogyo Co., Ltd.) Case MR-0L+ (Honda Tsushin Kogyo Co., Ltd.) Model JUSP-TA0PG-E JUSP-TA0PG--E JUSP-TA0PG--E Cable Length (L) 0. m m m L Note: The pin numbers in the PACK connector and the pin numbers in the terminal block are the same. If assembling cables, refer to Cable with Loose Wires at One End for CN Connection Diagram of JZSP-CSI0- -E Cable on the next page. 66

Selecting Cables () Cable with Loose Wires at One End for CN External Dimensions of Cable (Units: mm) PACK End Connector 00-6000EL (0P) Case 00-Z0-008 Sleeve F () Model JZSP-CSl0--E JZSP-CSl0--E JZSP-CSl0--E Cable () SSRFPVV-SBAWG#8 P UL076VW SC Wire Markers L 00 +0-0 : Manufactured by Sumitomo M Ltd. Cable Length (L) m m m Cable with Loose Wires at One End for CN Connection Diagram of JZSP-CSI0- -E Cable Pin No. 6 7 8 9 0 6 7 8 9 0 6 7 8 9 0 6 7 8 9 0 6 7 8 9 0 PACK End Wire Marking Signal Color Color SG Orange PL Orange SG Gray SEN Gray V-REF White SG White PULS /PULS T-REF SG SIGN Orange /SIGN Orange PL Gray /CLR White CLR White Gray PL PCO /PCO BAT + Orange BAT Orange Gray Gray /V-CMP+ White /V-CMP White /TGON+ /TGON /S-RDY+ /S-RDY ALM+ ALM PAO /PAO PBO /PBO ALO ALO ALO /S-ON /P-CON P-OT N-OT /ALM-RST /P-CL /N-CL +V-IN Orange Orange Gray Gray White White Orange Orange Gray Gray White White Dots Host Controller End Lead Marker 6 7 8 9 0 6 7 8 9 0 6 7 8 9 0 6 7 8 9 0 6 7 8 9 0 Case Shield Represents twisted-pair wires. 67

Analog/Pulse Type PACKs SGDV- 0/0 Selecting Cables () Digital Operator (Model: JUSP-OP0A--E) (Units: mm) 70 -M Screws, Depth REF YASKAWA ALARM 0 Nameplate SVON READ Connector: HDR-EMAG+(Honda Tsushin Kogyo Co., Ltd.) Case: HDR-ELPA(Honda Tsushin Kogyo Co., Ltd.) WRITE DIGITAL OPERATOR 7.8 7 000 +0 0 () Digital Operator Converter Cable for CN (Model: JZSP-CVS0-A-E) A converter cable is required to use series digital operators (model: JUSP-OP0A) for series PACKs. External Dimensions (Units: mm) (9.) (.7) (9) Connector (-pole) 0-60PL (Sumitomo M Ltd.) 0 Cover FA806 (Yasco Components Co., Ltd.) 00 +0 0 () (.8 Dia.) JZSP-CVS0-A-E Connector (-pole) HDR-EMAG + (Honda Tsushin Kogyo Co., Ltd.) (8) () Cover HDR-ELPA (Honda Tsushin Kogyo Co., Ltd.) Analog/Pulse Type PACKs (6) Connection Cable for Personal Computer for CN7 (Model: JZSP-CVS06-0-E) External Dimensions (Units: mm) 0 to 0,00 +00 0 JZSP-CVS06-0-E (00) () IMPORTANT Use a cable specified by Yaskawa. When using other cables, operation cannot be guaranteed. 68

Selecting Cables (7) Cable for Analog Monitor for CN (Model: JZSP-CA0-E) External Dimensions (Units: mm) Socket DF-DS-C Contact DF-8SCF 000 +0-0 White : Manufactured by Hirose Electric Corporation. View from Cable End Pin No. Cable Color Signal Standard Settings Analog Monitor Motor speed : V/000 min - White Analog Monitor, ( cables) GND(0V) Torque reference : V/00 rated torque Note : The specifications above are factory settings. Monitor specifications can be changed by changing parameters Pn006 and Pn007. (8) Cable with Connector for CN8 (Model: JZSP-CVH0-0-E) External Dimensions (Units: mm) () Pin No. Signal Lead Color Marking Color 000+0 Not used (0) (8) Not used Connector Kit 09- (Tyco Electronics AMP K.K.) () /HWBB White /HWBB White /HWBB Gray 6 /HWBB Gray 7 EDM Orange 8 EDM Orange 69