Transmission Line Support Systems

Similar documents
AUXILIARY FRAMING AND ACCESSORIES

1LG WALL MOUNTS - 1LG

Roof-Top Applications

SIG-032-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY III LUMINAIRE ARM (SEE CONTRACT) 6'-0", 8'-0", 10'-0" NOMINAL SPREAD

Factory Assistance: Phone: Fax: Page 1

Index Pipe Hangers and Straps

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

A - Railing Frame Material Specifications

table of contents Sliding Door Accessories Page Latches & Snuggers Stay Rollers Brackets & Stops

Midwest Roadside Safety Facility

Multi-Stage ASSEMBLY INSTRUCTIONS ST-8100 SERIES. 125 TAYLOR PARKWAY ARCHBOLD, OH PHONE: (419) FAX: (419)

Max. Rec. Load. Wt. Per Inch lbs. kn lbs. kn lbs. kg. Wt. Per Inch lbs. kn lbs. kn lbs. kg 750 F (399 C)

SIG-030-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY I LUMINAIRE ARM 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) POLE CAP

Installation Instructions Hustler 6-BTV Trap Vertical

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials

APPENDIX FENCE GENERAL NOTES

Copper Tubing Hangers Clevis Hangers. Copper Tubing Hangers

Standard Pole Mount Parabolic Antenna Mounting Instructions 3 ft. (90cm) & 4 ft. (120cm)

MISCELLANEOUS SIGN CONNECTION DETAILS TYPICAL ROUTE MARKER ASSEMBLIES SIGN TO POST MICHIGAN DEPARTMENT OF TRANSPORTATION

Hex Head Bolt Set N - Includes lock nut. Used to connect male and female T connectors. Galvanized. 3/4" x 3-1/2". Standard Grade (f) Part #24279

MDOTProjectwise\Documents\Reference Documents\Traffic Reference\Statewide Special Details\Develop

8" PIVOT. Model 8000 Pivot - Prior to Feb 2002

PIPE/CONDUIT SUPPORTS

Section 11 CABLE & ROD SYSTEMS, SIGN FIXING & SIGN STANDOFFS. Web. acrylicdesign.ie .

Superstrut Stainless Steel Channels and Accessories

Wrenches. Wrenches. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

Installation Instructions Hustler 6-BTV Trap Vertical

Door Canopy. PDL Building Products Industrial Parkway, N. Olmsted, OH Phone:

Installation Instructions for Solar Snow Pad (SSP-T-3)

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials

ALL SEASON PATIO COVER

1-1/4 PIPE 36-1/2 VERTICAL 1-1/4 PIPE 42-1/2 VERTICAL. Wa gner Companies FAX:

Swifts cable ladder supports

TYPICAL STANDOFF GLASS RAIL ELEVATION TYPICAL SECTION RS0B20 WITH RECTANGULAR BACK PLATE TYPICAL STAIRS

INSTRUCTION SHEET. PIECE INVENTORY - MOBILE BASES Refer to the diagram for part identification.

Available in high-capacity. and assembled by hand for smooth operation. Durable chrome-plated finish. Heat-treated for long life.

Swerve Rack CUSTOM RACKS AVAILABLE

Roof Mount Ground Mount Specialised Clamps Spares Application Notes

INDEX PAGE RELEASE SECTION NUMBER DATE

BRIDGE RAILING, 4 TUBE B-26-F POST DETAILS MICHIGAN DEPARTMENT OF TRANSPORTATION

ULTRA SPACE SAVER Installation Instructions

POLE LINE HARDWARE POLE LINE HARDWARE. HI-LINE UTILITY SUPPLY CO. Phone: Fax:

Side-of-Pole Mount for 4 Modules (SPM4) For Module Type B ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation

INSTALLATION INSTRUCTION RRU DOUBLE LIGHT POLE MOUNT

SIGNALS AND LIGHTING FIELD GUIDE

Leveling Feet, Base Plates and Casters

M2 Antenna Systems, Inc. Model No: HFTB6MXP20-2X2

PRODUCT CATALOG Meadowview Rd Junction City, OR fax

Real Life Ninja Complete Starter Pack (14ft. Warped Wall) Assembly Instructions

NON-PENETRATING ROOFTOP HANGERS AND SUPPORTS

Catalog. Mounts. Racking. Systems. Rail Clamps L-Feet. Pub. C10001-V016

Catalog. Mounts. Racking. Systems. Rail Clamps L-Feet. Pub. C10001-V013

ASSEMBLY INSTRUCTIONS

southpaw enterprises, inc.

RT-2632 OWNER'S MANUAL TAPERED TOWER. Call (800)

Recommended Tools: Before You Begin:

CABLE RUNWAY & TRAY PRODUCTS

H HD Adult Wheelchair Swing Frame & Hangers(perm) IMPORTANT

Cable Runway. Telco-Style Cable Runway. UL Classified Cable Runway

Cannonball Illustrations & Info

Downtown Rack. Custom logo option available

INSTALLATION INSTRUCTIONS FOR HAND OPERATED SILENT STEEL ADC HEAVY DUTY CURTAIN TRACK MODELS: 280, 281, 282, 280-A, 283-N, 283-R

CEILING-MOUNTED MONORAIL ANCHOR TRACK SYSTEM Assembly and Operation Instruction Manual

SADDLE BUDDY EASY ASSEMBLY. The Saddle Buddy is easy to install Galvanized Surface In-Ground. Rail.

(50 FT FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" 8-0" 6-0" Truss Depth. 3" sheets 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

Installation Instructions - Model V4JSD 1

MODULAR HIGH TUNNEL INSTALLATION GUIDE

Installation Instructions TMW Antenna Tower Mount for 4ft (1.2m) Antennas.

HOUSE PARTS PACKED IN HOUSE BOX PARTS IN PLASTIC BAG (HARDWARE) PARTS IN SMALL PLASTIC BAG (FLOOR CLIPS) PARTS PACKED IN BUNDLE

Steel Casework Metal Framing System

ASSEMBLY INSTRUCTIONS

Installation Instruction

Assembly Instructions

VPN: ISBXLR. Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

Side-of-Pole Mount for 4 Modules (SPM4) For Module Type D

STRUCTURAL BRACKETS CATALOGUE

System 3000 specifications

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

Cat. No. A1200 A1200-S A1200-KO. Finishes & Materials. E142-1/4x100EG 1/4 x 1 A100-5/16EGC A100-3/8EGC. Standard Finish: Electrogalvanized

Catalog. Mounts. Racking. Systems. Rail Clamps L-Feet. Pub. C10001-V020

Pole Mount Installation Manual

CABLE TRAY SYSTEM 136

DX-TVMLPTB03. Low-Profile TV Wall Mount ASSEMBLY GUIDE. For either wood-stud or concrete wall installations

INSTRUCTION BOOKLET #C20

ASSEMBLY INSTRUCTIONS

FURNITURE LABORATORY METAL FRAMING SYSTEM. For additional information and help in planning contact Mott Manufacturing.

Clamps 2 3/4" Mounting Bolts. Ground Wire Dia. (in) MBA-72 5/ /4" Ground Wire Dia. (in) Pole Clearance

CONTENTS CABLE MANAGEMENT AND

ClearSpan End Frame Kit 30' Wide x 11' High

Beam and Purlin Clamps Beam Clamps

Copyright 2005 Valmont Industries, Inc.

Offering a full range of anchoring and tie down systems including:

ULTRA SPACE SAVER SQUARED Installation Instructions

ULT R A SPAC E SAV E R

AWNING / PATIO COVER INSTALLATION INSTRUCTIONS

Pocket Shelter. Covered bike parking earns your site LEED credits.

March 1, Fax:

Oxford Stalls Installation Instructions

BIKE FILE (301)

Transcription:

Antenna Support Bracket for transmission line The Antenna Support Bracket angle mounts directly to a 4-1/2" (114 mm) OD antenna pipe mount or tower leg. This is ideal for supporting transmission line runs close to the antenna and for positioning the line to begin a vertical run. B358 includes: 1-2" (51 mm) x 2" (51 mm) x 3/16" (5 mm) Angle, 3' (914 mm) long 1 - U-bolt Assembly 1 - Channel Attachment Pipe-Leg Support Clamp for transmission line Clamps are heavy-duty 3/16" (5 mm) x 1-1/2" (38 mm) galvanized steel formed to fit common tower-member diameters. The pre-punched holes are used to attach either or Butterfly Hangers or Coax Blocks using 3/8" hardware. Snap-in Hangers are supported using the Snap-in Adapter (p. 2.02). Conduit runs and ground wire can also be attached to the Clamps. Included are two 1/2" x 1-3/4" bolts, nuts, and lock washers. 4-1/2 (114 mm) OD Pipe 3-7/8 (98 mm) A 3/16 (5 mm) x 1-1/2 (38 mm) galvanized plate 9/16 (14 mm) dia hole for coax block B Hangers and hardware not included 7/16 (11 mm) diameter holes for cushion hangers or snap-in adapter plate 6 (152 mm) 7/16 (11 mm) dia hole for ground wire and conduit attachment Use B1205 screw, lock washer, and B864 nut Two clamp bolts included Coax blocks and hardware not included 3 (914 mm) B358 Antenna Support Bracket Spacing to be in accordance with transmission line manufacturer recommendations Tower Leg Pipe OD Dim. A Dim. B in (mm) in (mm) in (mm) B1312 1.9 (48)-2 (51) 1' 1-13/16"(351) 1-15/16 (49) B123 2-3/8 (60)-2-1/2 (64) 1' 1-13/16"(351) 1-15/16 (49) B135 2-7/8 (73)-3 (76) 1' 1-13/16"(351) 1-15/16 (49) B142 3-1/4 (83)-3-1/2 (89) 1' 1-13/16"(351) 1-15/16 (49) B147 4 (102) 1' 1-13/16"(351) 1-15/16 (49) B151 4-1/2 (114) 1' 1-13/16"(351) 1-15/16 (49) B2173 5 (127) 1' 1-13/16"(351) 1-15/16 (49) B155 5-9/16 (141) 1' 1-13/16"(351) 1-15/16 (49) B2174 6 (152) 1' 1-13/16"(351) 1-15/16 (49) B163 6-5/8 (168) 1' 1-13/16"(351) 1-15/16 (49) B169 8-5/8 (219) 1' 1-13/16"(351) 1-15/16 (49) B177 10-3/4 (273) 1' 1-13/16"(351) 1-15/16 (49) B582 12-3/4 (324) 1' 1-13/16"(351) 1-15/16 (49) B1124 14 (356) 1' 1-13/16"(351) 1-15/16 (49) B1305 16 (406) 1' 3-7/16"(392) 1-15/16 (49) B1455 18 (457) 1' 3-7/16"(392) 2-7/16 (62) B2040 20 (508) 1' 6-11/16"(475) 1-15/16 (49) B2041 22 (559) 1' 6-11/16"(475) 1-15/16 (49) B2042 24 (610) 1' 6-11/16"(475) 1-15/16 (49) Vertical Supports - 2.01

Round-Leg Support Clamp for transmission line Clamps are formed to fit small diameter tower members, such as solid-rod legs. The pre-punched holes are used to attach or Butterfly Hangers or Coax Blocks using 3/8" hardware. Snap-in Hangers are supported with the Snap-in Adapter, below. Material is 3/16" (5 mm) x 1-1/2" (38 mm) galvanized steel. 9/16 (14 mm) diameter hole for Coax Block 7/16 (11 mm) diameter hole for Hanger or Snap-In adapter plate hangers and hardware not included 3-7/8 (98 mm) A B Solid rod leg Two clamp bolts included 7/16 (11 mm) diameter hole for ground wire and conduit attacnment 6 (152 mm) Use B1205 Screw, Lock washer and B864 Nut Coax Blocks and hardware not included Pipe OD Dim. A Dim. B in (mm) in (mm) in (mm) B1450 1/2 (13)-7/8 (22) 6-3/16" (157) 1-15/16 (49) B1451 1 (25)-1-3/8 (35) 6-3/16" (157) 1-15/16 (49) B1452 1-1/2 (38)-1-7/8 (48) 6-3/16" (157) 2-5/16 (59) Snap-In Adapter for Pipe- & Round-leg Support Clamp The Snap-in Adapter, which bolts to the Pipe-leg or Round-leg Support Clamps, provides the capability to use Snap-in Hangers for support of coax transmission lines. If a run of waveguide needs to be installed. B1757 (p. 6.01) will convert the 3/4" (19 mm) diameter hole to enable the use of 3/8" diameter hardware. Universal Snap-In Brackets for Angle- or Pipe-Leg The Universal Snap-In Bracket supports up to 16 Snap-In Hangers for support of coax transmission lines on angleleg or pipe-leg structures. Also provided are 7/16" (11 mm) diameter holes to support or Butterfly Hangers. Galvanized. Included 1/2" hardware 3/4" (19 mm) diameter holes for Snap-In Hangers 2-1/2" (64 mm) 2-1/2" (64 mm) Angle-Leg or Pipe-Leg 7/16" (11 mm) diameter holes for Hangers 12 16 Angle Leg Size Pipe Leg Size Runs Runs in (mm) in (mm) B2249 B2252 2-1/2 (64) x 2-1/2 (64) 1-1/2 (38) OD to to 4 (102) x 4 (102) 5-9/16 (141) OD B2250 B2253 5 (127) x 5 (127) to 6 (152) OD to 6 (152) x 6 (152) 8-5/8 (219) OD B2251 B2254 8 (203) x 8 (203) 10-3/4 (273) OD to 12-3/4 (324) OD Angle 3-Leg Support Clamp for transmission line Clamps provide support for either six Hangers, six Snap-In Hangers, or two Coax Blocks. Material is galvanized steel. 3/4 (19 mm) diameter holes for Snap-in Hangers Holes also provided for 6 Snap-In or Butterfly Hangers and Hangers or 2 Coax Blocks Coax Blocks and hardware not included Pipe-leg support clamp Snap-in Hanger Hangers and hardware not included Snap-In Hangers not included For B2034 12 Coax runs B1717 9 Coax runs B1720 6 Coax runs 2.02 - Vertical Supports Leg Size in (mm) B1753 3-1/2 (89) x 3-1/2 (89) & 4 (102) x 4 (102)

Angle 4-Leg Support Clamp for transmission line Clamps provide support for either six Hangers, six Snap-In Hangers, or two Coax Blocks. Material is 3/16" (5 mm) galvanized steel. Hangers and hardware not included Holes also provided for 6 Snap-In Butterfly Hangers and Hangers or 2 Coax Blocks Coax Blocks and hardware not included Cluster Support Bracket Bracket models support either Hangers or Snap- In Hangers and are fabricated from 1/8" (3 mm) hot-dip galvanized steel. The Bracket mounting hole is 9/16" (14 mm) diameter. The B2211 is 10-1/4" (260 mm) long. 2" (51 mm) 7-1/2" (191 mm) 5-1/4" (133 mm) Snap-In Hangers not included B1258 B1259 B2211 Accommodates 7 Hangers 7 Snap-In Hangers 9 Snap-In Hangers Leg Size in (mm) B1472 2 (51) x 2 (51) & 3 (76) x 3 (76) B1473 3-1/2 (89) x 3-1/2 (89) & 4 (102) x 4 (102) B1474 5 (127) x 5 (127) & 6 (152) x 6 (152) B1475 8 (203) x 8 (203) Climbing-Ladder Support Bracket for transmission line The Bracket supports up to seven Snap-In Hangers for support of coax transmission line on climbing ladders built with vertical angle members. The Bracket attaches to angle sizes from 2-1/2" (64 mm) x 2-1/2" (64 mm) to 4"(102) x 4"(102) and may mount on either leg of the angle. To use cushion hangers, B1757 (p. 6.01) will convert the 3/4" (19 mm) diameter hole to enable the use of 3/8" diameter hardware. Galvanized. Installation Examples Transmission line runs can be clamped directly to a round tower leg or diagonal, as shown (Fig. A), by using two clamp heads back-to back. The clamp heads must be bolted together (Fig. B) before installing either the Hanger or the adjustable Clamp. Threaded rod standoffs may be used to extend the transmission line away from obstructions, for either angle-leg towers (Fig. C) or pipe-leg towers. Hanger Transmissionline Figure A Diagonal tower member Use B238 Screw and B864 Nut to join clamp heads B185 Adjustable Clamp 3/8 hardware B399 Clamp Head B399 Clamp Head 3/8 hardware Snap-In Hanger not included Seven 3/4 (19 mm) diameter holes for Snap-In Hangers Hanger B185 Adjustable Clamp Figure B Ladder rung Climbing ladder angle rail 3/8 Threaded Rod B1576 Universal Clamp B1292 Cross Leg Size in (mm) B1558 2-1/2 (64) x 2-1/2 (64) to 4 (102) x 4(102) B238 Screw and Lockwasher Figure C Vertical Supports - 2.03

Cross The B1292 Cross is tapped through for convenience of leveling Hangers on the 3/8" Threaded Rod. Designed for versatility and made of PVC, the Cross may be used in combinations to accommodate any number or size of transmission line runs. Five per Package. 1-1/2 (38 mm) diameter 3/4 (38 mm) Standoff Kit for Pipe The Standoff Kit provides 7/16" (11 mm) or a 3/4" (19 mm) diameter hole for support of a or Butterfly Hanger or Snap-In Hanger. The Bracket is attached directly to a round tower leg or diagonal with the included clamp. The Bracket and clamp are stainless steel. Ten per package. 7/16 (11 mm) hole for 3/8 hardware or 3/4 (19 mm) hole for Snap-In Hanger B1292 Cross, 5 per package Super Cross The Super Cross, made of lightweight aluminium, is threaded for 3/8" hardware to support up to 5 cushion Hangers. Transmission line support is simplified since only one tower attachment point supports multiple Hangers, each of which can support multiple transmission lines, depending on the line size. Attachment hardware includes a 3/8" diameter x 3" (76 mm) long stud, lockwasher and nut. B240 or B251 B174 3/8 Spring Nut with square spacer Tower member Pipe OD with 7/16" (11 mm) with 3/4" (19 mm) in (mm) hole, 10/pack 1 hole, 10/pack 3/4 (19) - 1-1/2 (38) B2126 1-1/2 (38) - 3 (76) B2127 B2131 3 (76) - 4 (102) B2128 B2132 4 (102) - 5 (127) B2129 B2133 5 (127) - 6 (152) B2130 B2134 3 (76) and up B2135 2 B2136 2 1 Kits with 7/16" (11 mm) hole include 3/8" diameter fillester slotted screw, lock washer and nut. 2 Bracket only, clamp not included, will accept up to 3/4" banding. Snap-In Box Snap-In Box provides three 3/4" (19 mm) diameter holes for the attachment of Snap-In Hangers. The Box mounts to tower members, Universal Clamps or Standoff Kits with included 3/8" hardware. Hot-dip galvanized after fabrication. Standoff Kit with 7/16 (11 mm) hole, ordered separately B357 Super Cross 3-3/8 (86 mm) Snap-In Box Three 3/4 (19 mm) dia holes for Snap-In Hangers, ordered separately, (p.6.06) B357 Super Cross B2143 Snap-In Box 2.04 - Vertical Supports

Heavy Duty Welded Coax Support Ladder with Angle Rail and Rungs The Coax Support Ladder, in lengths of 5' (1.524 m), 10' (3.048 m), and 20' (6.096 m), is provided in welded sections, that include 2-1/2" (64 mm) x 2-1/2" (64 mm) x 1/4" (6 mm) angle rails, angle rungs, and hardware for tower attachment. The maximum span between tower attachments is 20' (6.096 m) Two hardware mounting kits are provided with the 20' (6.096 m) ladder, and one hardware mounting kit is provided with the 10' (3.048 m) ladder and the 5' (1.524 m) ladder. Each hardware mounting kit includes two brackets and hardware to attach the ladder to the tower. There are two ladder widths available, 3' 1-1/2" (953 mm) for 12 runs of coax and 3' 10-1/2" (1.181 m) for 15 runs of coax. The rung spacing is 3' 4" (1.016 m) and has 3/4" (19 mm) holes for Snap-In Hangers and 7/16" (11 mm) holes for Hangers or Butterfly Hangers to support coax transmission line up to 2-1/4" diameter. Each ladder section is furnished with splices to interconnect with the next section. The ladder for round tower members attaches to an 1-1/2" (38 mm) to 4-1/2" (1.231 m) OD round tower girt or diagonal with included brackets and hardware. The ladder for angle tower members attaches to a 5" (127 mm) maximum, girt or diagonal, with included J-bolts and backing plates. An optional J-bolt can be ordered when the angle tower member exceeds 5" (127 mm). J-bolt part number B2335 (p. 14.04) will accommodate angle tower members from 5" (127 mm) to 7" (178 mm) in width. When the Ladder extends to ground level below the lowest girt, a Ladder Base Kit is required to support the ladder at ground level. The Kit consists of stub angles that either install in a concrete footing or bolt to a concrete pad. Material is hot-dip galvanized after fabrication. Coax Ladder for Round Tower Member B2164 5' (1.524 m) Coax Ladder, 3' 1-1/2" (953 mm) wide for 12 runs of coax, attaches to round tower member B2165 10' (3.048 m) Coax Ladder, 3' 1-1/2" (953 mm) wide for 12 runs of coax, attaches to round tower member B2166 20' (6.096 m) Coax Ladder, 3' 1-1/2" (953 mm) wide for 12 runs of coax, attaches to round tower member B2255 5' (1.524 m) Coax Ladder, 3' 10-1/2" (1.181 m) wide for 15 runs of coax, attaches to round tower member B2256 10' (3.048 m) Coax Ladder, 3' 10-1/2" (1.181 m) wide for 15 runs of coax, attaches to round tower member B2257 20' (6.096 m) Coax Ladder, 3' 10-1/2" (1.181 m) wide for 15 runs of coax, attaches to round tower member B2486 Round Member Hardware Mounting Kit B1751 Ladder Base Kit Twelve 3/4 (19 mm) diameter holes for Snap-In Hangers and twelve 7/16 (11 mm) diameter holes for and Butterfly Hangers 1-1/2 (38 mm) to 4-1/2 (114 mm) Round tower girt or diagonal 3/4 (19 mm) diameter holes 7/16 (11 mm) diameter holes Coax Ladder for Angle Tower Member B2443 5' (1.524 m) Coax Ladder, 3' 1-1/2" (953 mm) wide for 12 runs of coax, attaches to angle tower member B2444 10' (3.048 m) Coax Ladder, 3' 1-1/2" (953 mm) wide for 12 runs of coax, attaches to angle tower member B2445 20' (6.096 m) Coax Ladder, 3' 1-1/2" (953 mm) wide for 12 runs of coax, attaches to angle tower member B2446 5' (1.524 m) Coax Ladder, 3' 10-1/2" (1.181 m) wide for 15 runs of coax, attaches to angle tower member B2447 10' (3.048 m) Coax Ladder, 3' 10-1/2" (1.181 m) wide for 15 runs of coax, attaches to angle tower member B2448 20' (6.096 m) Coax Ladder, 3' 10-1/2" (1.181 m) wide for 15 runs of coax, attaches to angle tower member B2487 Angle Member Hardware Mounting Kit B1751 Ladder Base Kit 3 4 (1.016 m) rung spacing 10 (3.048 m) preferred spacing 20 (6.096) max. 3 1-1/2 (953 mm) 1-1/2 (38 mm) 1-1/2 (38 mm) 2 (51 mm) min. 5 (127 mm) max. Angle tower girt or diagonal Vertical Supports - 2.05

Bolt-Together Coax Support Ladder with Angle Rail and Rungs Coax Support Ladders are available in three lengths, 5' (1.524 m), 10' (3.048 m) and 20' (6.096 m), and are available in factory assembled or field assembled sections. Each ladder section is constructed of angle rungs bolted to 1-3/4" (44 mm) x 1-3/4 (44 mm) angle rails and includes the hardware for tower attachment. The maximum span between tower attachments is 10' (3.048 m). Two hardware mounting kits are provided with the 20' (6.096 m) ladder and one hardware mounting kit is provided with the 10' (3.048 m) ladder and the 5' (1.524 m) ladder. Each mounting hardware kit includes two brackets and hardware to attach the ladder to the tower. The ladder is available in two widths, 2' 8-1/4" (819 mm) for 12 runs of coax and 3' 3-3/4" (1.010 m) for 15 runs of coax. The rung spacing is 3' 4" (1.016 m) and has 3/4" (19 mm) holes for Snap-In Hangers and 7/16" (11 mm) holes for or Butterfly Hangers to support coax transmission lines up to 1-5/8" diameter. Each ladder section is furnished with splices to interconnect with the next section. The ladder for round tower members attaches to an 1-1/2" (38 mm) to 4-1/2" (114 mm) OD round tower girt or diagonal with included brackets and hardware. The ladder for angle tower members attaches to a 5" (127 mm) maximum, girt or diagonal, with included J-bolts and backing plates. An optional J-bolt can be ordered when the angle tower member exceeds 5"(127 mm). J-bolt part number B2335 (p. 14.04) will accommodate angle tower members from 5" (127 mm) to 7" (178 mm) in width. When the Ladder extends to ground level below the lowest girt, a Ladder Base Kit is required to support the ladder at ground level. The Kit consists of stub angles that either install in a concrete footing or bolt to a concrete pad. Material is hot-dip galvanized after fabrication. B2467 B2468 B2469 B2470 B2471 B2472 B2486 B1751 Factory Assembled Coax Ladder for Round Tower Member 5' (1.524 m) Factory Assembled Coax Ladder, 2' 8-1/4" (819 mm) wide for 12 runs of coax, attaches to round tower member 10' (3.048 m) Factory Assembled Coax Ladder, 2' 8-1/4" (819 mm) wide for 12 runs of coax, attaches to round tower member 20' (6.096 m) Factory Assembled Coax Ladder, 2' 8-1/4"(819 mm) wide for 12 runs of coax, attaches to round tower member 5' (1.524 m) Factory Assembled Coax Ladder, 3' 3-3/4" (1.01 m) wide for 15 runs of coax, attaches to round tower member 10' (3.048 m) Factory Assembled Coax Ladder, 3' 3-3/4" (1.01 m) wide for 15 runs of coax, attaches to round tower member 20' (6.096 m) Factory Assembled Coax Ladder, 3' 3-3/4" (1.01 m) wide for 15 runs of coax, attaches to round tower member Round Member Hardware Mounting Kit Ladder Base Kit Factory Assembled Coax Ladder for Angle Tower Member B2455 5' (1.524 m) Factory Assembled Coax Ladder, 2' 8-1/4" (819 mm) wide for 12 runs of coax, attaches to angle tower member B2456 10' (3.048 m) Factory Assembled Coax Ladder, 2' 8-1/4" (819 mm) wide for 12 runs of coax, attaches to angle tower member B2457 20' (6.096 m) Factory Assembled Coax Ladder, 2' 8-1/4"(819 mm) wide for 12 runs of coax, attaches to angle tower member B2458 5' (1.524 m) Factory Assembled Coax Ladder, 3' 3-3/4" (1.01 m) wide for 15 runs of coax, attaches to angle tower member B2459 10' (3.048 m) Factory Assembled Coax Ladder, 3' 3-3/4" (1.01 m) wide for 15 runs of coax, attaches to angle tower member B2460 20' (6.096 m) Factory Assembled Coax Ladder, 3' 3-3/4" (1.01 m) wide for 15 runs of coax, attaches to angle tower member B2487 Angle Member Hardware Mounting Kit B1751 Ladder Base Kit 2.06 - Vertical Supports

Bolt Together Coax Support Ladder, continued Twelve 3/4 (19 mm) diameter holes for Snap-In Hangers and twelve 7/16 (11 mm) diameter holes for and Butterfly Hangers 2 (51 mm) min. 5 (127 mm) max. angle tower girt or diagonal 3/4 (19 mm) diameter holes 10 (3.048 m) maximum spacing 3 4 (1.016 m) rung spacing 1-1/4 (32 mm) 7/16 (11 mm) diameter holes Included 1/2 diameter hardware 1-1/4 (32 mm) 1-1/2 (38 mm) to 4-1/2 (114 mm) Round member tower girt or diagonal 2 8-1/4 (819 mm) B2461 B2462 B2463 B2464 B2465 B2466 B2486 B1751 Field Assembled Coax Ladder for Round Tower Member 5' (1.524 m) Field Assembled Coax Ladder, 2' 8-1/4" (819 mm) wide for 12 runs of coax, attaches to round tower member 10' (3.048 m) Field Assembled Coax Ladder, 2' 8-1/4" (819 mm) wide for 12 runs of coax, attaches to round tower member 20' (6.096 m) Field Assembled Coax Ladder, 2' 8-1/4"(819 mm) wide for 12 runs of coax, attaches to round tower member 5' (1.524 m) Field Assembled Coax Ladder, 3' 3-3/4" (1.01 m) wide for 15 runs of coax, attaches to round tower member 10' (3.048 m) Field Assembled Coax Ladder, 3' 3-3/4" (1.01 m) wide for 15 runs of coax, attaches to round tower member 20' (6.096 m) Field Assembled Coax Ladder, 3' 3-3/4" (1.01 m) wide for 15 runs of coax, attaches to round tower member Round Member Hardware Mounting Kit Ladder Base Kit Field Assembled Coax Ladder for Angle Tower Member B2449 5' (1.524 m) Field Assembled Coax Ladder, 2' 8-1/4" (819 mm) wide for 12 runs of coax, attaches to angle tower member B2450 10' (3.048 m) Field Assembled Coax Ladder, 2' 8-1/4" (819 mm) wide for 12 runs of coax, attaches to angle tower member B2451 20' (6.096 m) Field Assembled Coax Ladder, 2' 8-1/4"(819 mm) wide for 12 runs of coax, attaches to angle tower member B2452 5' (1.524 m) Field Assembled Coax Ladder, 3' 3-3/4" (1.01 m) wide for 15 runs of coax, attaches to angle tower member B2453 10' (3.048 m) Field Assembled Coax Ladder, 3' 3-3/4" (1.01 m) wide for 15 runs of coax, attaches to angle tower member B2454 20' (6.096 m) Field Assembled Coax Ladder, 3' 3-3/4" (1.01 m) wide for 15 runs of coax, attaches to angle tower member B2487 Angle Member Hardware Mounting Kit B1751 Ladder Base Kit Vertical Supports - 2.07

Lightweight Support Rail Lengths of B240 or B251 can be joined together with B252 Splices to fabricate a lightweight vertical transmission line support. One side of the is used to attach Hangers at desired intervals using Spring Nuts and 3/8" hardware. The other side attaches to the tower using various methods, depending on the tower construction. The recommended maximum span between tower attachment points is 20 feet (6.096 m), based on a loading of 20 lb (27.120 Nm) per lineal foot. Transmission line runs of this type should be installed near a climbing ladder or tower leg since the support rail itself offers no footing for workers installing the linesupport components. Rails are 1-5/8" (41 mm) square, 12-gauge (3 mm) galvanized steel that is spot welded back-to-back. When used for horizontal transmission line support, the top Rail slot is used for attachment to Pipe Heads with 1/2" hardware and 1/2" Spring Nuts (B262). The lower Rail slot is used to attach transmission line with 3/8" hardware and 3/8" Spring Nuts (B174). See page 6.01 B174 Spring Nut and 3/8 hardware 7/16 (11 mm) splice holes Hanger Tower Member B252 Square Rail Splice B240 B251 10' (3.048 m) long 20' (6.096 m) long B1292 Cross Typical Transmission line Attachment B262 Spring Nut and 1/2 s.s. hardware Tower girts B682 1/2 Bolt Assembly Spacing in accordance with transmission line manufacturer recommendations B240 10 (3.048 m) length or B251 20 (6.096 m) length Splice for The Splice is used to join sections of Square Rail. It includes two splice plates and four bolts, washers and nuts. All parts are galvanized. B251 B1577 Universal Clamp B297 Clip Angle Typical Clamping Method Tower member B252 Square Rail Splice B252 Splice B297 Clip Angle Alternate Clamping Method 2.08 - Vertical Supports

Lightweight Support Ladder with Vertical support ladders for self-supporting towers can be fabricated using standard products, as shown. Ladders are 3' 4" (1.016 m) wide and are attached to the face of the tower. The recommended maximum span is 20' (6.096 m) between tower attachment points. This is based on a loading of 40 pounds (54.233Nm) per lineal foot resulting from a 100 mph (161 km/h) wind load on seven 1-1/2" (30 mm) elliptical waveguide runs. Cross Pieces, for either Hangers or Snap-In Hangers, are attached at desired intervals to one side of s using 3/8" Bolts and Spring Nuts (p. 14.03). The other side of the s attach to the tower with 1/2" hardware. Exact methods of attachment depend on the type of tower construction. Lengths of the rail are joined together with B252 Splices. Attaching hardware for the Rail and Cross Pieces is ordered separately. B291 Cross Piece Transmission line B843 3/8" x 1-1/4" Bolt, Lock Washer, B174 3/8" Spring Nut Hanger clamp heads attached with B298 Screws and B174 3/8" Spring Nuts Typical Transmission Line Attachment B251 B251 Rail B1647 or B291 Cross Piece, 3-4 (1.016 m) Tower Member B297 Clip Angle Alternate Clamping Method B262 Spring Nut and 1/2" s.s. hardware Tower girts B252 Splice B682 1/2" Bolt Assembly Tower Member B297 Clip B251 B1577 Universal Clamp Typical Clamping Method Vertical Supports - 2.09

Cross Piece for Support Ladder Cross Piece ladder rungs are available to support either Hangers or Snap-in Hangers. The B291, fabricated from 1-5/8" (41 mm) square rail, enables the attachment of eleven Hangers using 3/8" Spring Nuts (p. 14.03) and hardware. Multiple transmission line runs can be supported in each Hanger, depending on the line size. The B1647, fabricated from angle steel, provides sixteen 3/4" (19 mm) holes for installing Snap-in Hangers. The hole spacing of 2-1/2" (64 mm) on-centers allows 16 runs of up to 1-5/8" coax to mounted on each Cross Piece. Both Cross Pieces are 3' 4" (1.016 m) long and are hotdip galvanized steel. Adjustable Clamping Bar The Adjustable Clamping Bar is used to support vertical transmission-line runs and to terminate horizontal bridges on the face of angle leg towers. This is an extremely versatile product. Slots in the Clamping Bar allow it to attach to a variety of tower widths. Galvanized. Adjustable Clamping Bar includes: 1-4' 4" (1.321 m) long Clamping Bar 2-3/8" x 3-1/4" Bolts and Lock Washers 2-3/8" Universal Clamps 2-2-1/2" (64 mm) Standoff Brackets 3" (76 mm) standoff tower leg Adjustable from 1' (305 mm) x 4' 2" (1.270 m) Snap-In Hanger B251 Two Standoff Brackets can be bolted anywhere along Clamping Bar 3/4" (19 mm) dia hole B251 B516 Adjustable Clamping Bar 3' 4" (1.016 m) 3' 2" (965 mm) A A Hanger, B298 Screw, and B174 3/8" Spring Nut B516 Adjustable Clamping Bar Sixteen 3/4" (19 mm) holes for Snap-In Hangers B174 3/8" Spring Nut and B834 3/8" x 1-1/4" Bolt, Lock Washer (not included) B251 B515 Clip Angle and B174 3/8" Spring Nut B513 All-Purpose Angle B501 or B502 Bridge Channel View A-A Tower leg B291 B1647 For Hangers For Snap-In Hangers Standoff Bracket B516 Adjustable Clamping Bar 2.10 - Vertical Supports

Monopole Transmission Line Bracket Monopole Transmission Line Bracket supports three runs of coax or waveguide per Bracket. Multiple Brackets may be used per level depending upon the pole diameter. The Brackets are strapped to the Pole using the B1769 Banding (p. 13.05) and have 7/16" (11 mm) holes for Hangers, Butterfly Hangers, or 3/4" (19 mm) diameter holes for Snap-In Hangers Monopole Coax Support Kit Monopole Support Kits support coax on round or polygonal poles. The Bracket supports nine or twelve runs of 7/8" or 1-5/8" coax. Brackets are secured to the pole using B1769 Banding (p. 13.05). The Bracket is galvanized steel. Monopole Transmission Line Bracket Minimum one band required at top. Second band may be used for additional support. Snap-In Hangers ordered separately (p. 6.07) B2391 B2336 Hole Size 7/16" (11 mm) and 3/4" (19 mm) 3/4" (19 mm) Strap-On Bracket for Polygon & Round Holes Banding, Buckles and Tensioning Tools ordered separately, (p. 13.05) Bracket is strapped on to a pole using B1769 Banding (p. 13.05) and provides a 9/16" (14 mm) diameter hole for attachment of Coax Blocks or Snap-In Adapter Plates. Galvanized. Snap in hangers ordered separately (p. 6.07) B2421 B2422 B2423 B2424 B2421 Shown Capacity 9 runs of 7/8" coax 12 runs of 7/8" coax 9 runs of 1-5/8" coax 12 runs of 1-5/8" coax Banding, Buckles and Tensioning Tools ordered separately (p. 13.05) Banding, Buckles and Tensioning Tools ordered separately (p. 13.05) Coax Block and Hardware Kit ordered separately (p. 6.05) B1844 Strap-On Bracket Vertical Supports - 2.11

Covered Monopole Coax Support Kit Covered Monopole Coax Support Kits support coax on round or polygonal poles and protects the coax from the elements. Intermediate and Top Kits include two Strap-On Brackets for coax support, and Base Kits include three Strap-On Brackets for coax support. The Bracket supports nine or twelve runs of 7/8" or 1-5/8" coax. The 22-gauge (.85 mm) x 8' (2.438 m) steel Covers bolt directly to the Brackets. Brackets are secured to the pole using B1769 Banding (p. 13.05). The Kits are self splicing. An Alignment Tool is provided with each Base Kit for the proper installation of the Brackets. The Bracket and Covers are galvanized steel. Snap-In Hanger Mount for Pipe Leg The Snap-In Hanger Mount supports up to 12 Snap-In Hangers for support of coax transmission lines on pipelegs from 1' 6" (106 mm) up to 2' 6" (762 mm) in diameter. The Mount is 2' 11-1/4" (895 mm) long. Galvanized. 3 (76 mm) typ. Twelve 3/4 (19 mm) diameter holes for Snap-In Hangers Strap on Bracket 2 11-1/4 (895 mm) 8 (2.438 m) cover Banding, Buckles and Tensioning Tool ordered separatetly (p. 13.05) Pipe Size in (mm) B1949 1' 4" to 1' 6" (106 to 457) B1950 1' 8" to 1' 10" (508 to 559) B1951 2' to 2' 2" (610 to 660) B1968 2' 4" to 2' 6" (711 to 762) for for Base Kit Int./Top Kit Capacity B2243 B2392 9 runs of 7/8" coax B2244 B2393 12 runs of 7/8" coax B2245 B2394 9 runs of 1-5/8" coax B2246 B2395 12 runs of 1-5/8" coax 2.12 - Vertical Supports

Wall-Mounted Coax Support Bracket Wall-Mounted Coax Support Brackets support vertical or horizontal runs on a wall surface. The three Bracket models, furnished with 3/4" (19 mm) holes for Snap-In Hangers (p. 6.07), support four, eight, or twelve runs of coax. Two 7/16" (11 mm) diameter holes on each side of the Bracket provide for attachment of grounding lugs. Order bracket to wall attaching hardware separately (section 14). Two 7/16" (11 mm) dia holes on 1" (25 mm) centers for ground lug 9/16" (14 mm) dia holes for wall attachment 3/4" (19 mm) dia holes for Snap-In Hangers Wall-Mounted Coax Support Kit with Cover Wall-Mounted Coax Support kits include two wallmounted brackets for coax support and a steel cover to protect the runs on a wall surface. The wall-mounted brackets, furnished with 3/4" (19 mm) holes for Snap-In Hangers (p. 6.07), support four, eight, or twelve runs of 1/2" (13 mm) through 1-5/8" (41 mm) coax. The 16- gauge (1.6 mm) steel cover bolts directly to the brackets and has two 7/16" (11 mm) diameter holes on each side for attaching grounding lugs. Optional Cover Splices are available to interconnect covers for the 4-run and 8-run Kits. Covers for the 12-run Kit overlap with each other and thus are self splicing. Order bracket to wall attaching hardware separately (section 14) 3/8" (10 mm) dia tapped hole for cover attachment 2-1/2" (64 mm) typ. 1' 11-7/8" (606 mm) Width 4' (1.219 m) 8' (2.438 m) nominal Wall Mounted Coax Support Bracket Width B1586 for 4 runs 11-1/4" (286 mm) B1587 for 8 runs 1'9-1/4" (540 mm) B1588 for 12 runs 2'6-1/2" (775 mm) 1' 11-7/8" (606 mm) Two 7/16" (11 mm) dia holes on 1" (25 mm) centers for ground lug Width Width B1589 Wall mounted Coax Support Kit 11-1/2" (292 mm) for 4-runs, 7'11-3/4" (2.432 m) long B1590 Wall mounted Coax Support Kit 1'9-1/2" (546 mm) for 8-runs, 7'11-3/4" (2.432 m) long B1591 Wall mounted Coax Support Kit 2'6-3/4" (781 mm) for 12-runs, 8'1-1/2" (2.477 m) long B1607 Cover Splice for wall mounted Coax Support Kit, 4 runs B1608 Cover Splice for wall mounted Coax Support Kit, 8 runs Vertical Supports - 2.13