Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Similar documents
Valve amplifier for proportional valves with electrical position feedback

Valve amplifier for proportional pressure valves

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05

Booster amplifier. Table of contents. Features. RE 30260/04.12 Replaces: Type VT-MSFA1. Component series 1X 1/6

Valve amplifier for proportional pressure valves

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Valve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features

Analogue amplifier modules for 4/3 and 4/2 proportional directional valves 4WRE

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6

Electric amplifier for proportional cartridge throttle valves

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6

Electric amplifier for flow control with proportional

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

Electric amplifiers. List of contents. Features. RE 30052/08.05 Replaces: Type VT-VRPA1. Unit series 1X 1/6

p/q closed-loop control amplifier

4/3 proportional directional valve direct operated, with integrated electronics

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

4/3 proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF. Features.

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

RT-5005/5006/5007/5008

High-response valve with integrated digital axis controller (IAC-R) and field bus interface

RA / /6. Replaces: Table of contents RA /06.98

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Electric amplifiers. Table of contents. Features RA 30052/ Model VT-VRPA1. Series 1X 1/6

Analog amplifier RA. RE Edition: Replaces:

Service case with test unit for servo and proportional valves with integral electronics (OBE)

External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

DENISON HYDRAULICS Proportional Pressure Control Valves

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

External control electronics for the SYDEF1 adjustment of the A10VSO axial piston pump

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

External control electronics for the SYDFE1 control of A10VSO axial piston pumps Analogue amplifier, configurable

ELECTRONIC REGULATOR FOR OPEN LOOP

Type CP-S, CP-C & CP-A Switch mode

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

Continental Hydraulics Installation Manual CEM-PA-A

Proportional amplifier type EV22K5

Continental Hydraulics Installation Manual CEM-RA-A

Digital amplifier for proportional valves PEM XD

Directional control valve, direct operated, with integrated digital axis controller (IAC-Multi-Ethernet) Type 4WRPDH. Features.

External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump

4/3-way fast response valve Type 4WRGE

J IPC IGBT power converter

Smart Power Relay E I...

PHOENIX CONTACT - 09/2009

DEIF A/S. Insulation monitor. Type SIM-Q

Proportional amplifier type EV1M3

Operating Instruction

Technical Documentation

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

Analog position controller

Mobile dual solenoid driver

Drive electronics pq11

Sensor technologies Proximity sensors Series ST9. Brochure

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Proportional amplifier type EV1M3

Electronic Circuit Breaker ESS1 for System SVS1

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

Power supply CP-E 24/2.5

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

Operating Instructions

Power supply CP-T 24/20.0 Primary switch mode power supply

Installation / Monitoring Technique

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-E 24/20.0

Power supply CP-T 24/40.0 Primary switch mode power supply

EFC 3600 Frequency converter for higher energy efficiency and improved process control

Drive Electronics pq11

Power supply CP-E 24/0.75

Pulse Scaler for DIN Rail Attachment

Power supply CP-T 48/20.0 Primary switch mode power supply

Electronic Circuit Breaker ESS1 for System SVS1

MDSD (Series 2X) Mobile Dual Solenoid Driver

Electronic Circuit Protector ESX10

Electronic regulator for PWM controlled proportional solenoid valves FABER -

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Power supply CP-T 48/5.0 Primary switch mode power supply

Coils & Electronic Controls

Proportional Directional Control Valves Size 6

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

Electronic Circuit Breaker with reset input ESS20-1..

ISOMETER IRDH575. Approvals

Frequency converter. Frequency Converter Fe

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

Proportional directional valves

Digital axis control HNC100

This kind of information is useful to make reliable automatic control diagnostic and supervision systems. IS VS. Diameter of cylindrical types

QUINT-PS/ 3AC/24DC/40

Transcription:

Valve amplifier for proportional valves Type VT-MSPA2-1 RE 30228 Edition: 2014-01 Replaces: 2011-04 Component series 1X Suitable for controlling direct operated proportional directional valves without electric position feedback (type 4WRA, size 6 and 10, component series 2X) H7282 Features Command value input ±10 V (differential input) Ramp generator with separately adjustable ramp time "up/down" Characteristic curve correction by means of separately adjustable step levels and separately adjustable maximum values Enable input Reverse polarity protection for voltage supply Power supply unit with DC/DC converter LED displays: Ready for operation (green) Enable (yellow) Operating mode selector switch "S" Contents Features 1 Ordering code 2 Functional description 3 Block diagram 4 Technical data 5 Terminal assignment 6 Dimensions 6 Project planning/maintenance instructions/ additional information 7 Setting recommendation 7

2/8 VT-MSPA2-1 Valve amplifier Ordering code 01 02 03 04 05 06 VT-MSPA2 1 1X / V0 / 0 * 01 Valve amplifi er for proportional valves, analog, modular design VT MSPA2 02 For controlling the valves 4WRA6 (component series 2X) and 4WRA10 (component series 2X) 1 03 Component series 10 to 19 (10 to 19: Unchanged technical data and connections) 1X 04 Version: Standard V0 05 Option: Standard 0 06 Further details in the plain text *

Valve amplifier VT-MSPA2-1 3/8 Functional description General The amplifier modules are snapped onto top hat rails. The electrical connection is established via screw terminals. The modules are operated with 24 V direct voltage. Power supply unit [1] The amplifier modules have a power supply unit with making current limiter. This unit supplies all internally required positive and negative supply voltages. The making current limiter prevents high making current peaks. Command value presetting The internal command value signal is calculated from the total [3] of the external command value signal available at the differential input [2] and the zero point offset (zero point potentiometer "Zw"). A positive command value results in a current increase in the "b" solenoid and thus a flow in the valve from P to A and from B to T. A negative command value results in a current increase in the "a" solenoid and thus a flow in the valve from P to B and from A to T. Enable function [11] The enable function enables the power output stages and forwards the internal command value signal to the ramp generator. The enable signal is displayed by an LED on the front plate. If enable is connected, the internal command value is changed (with any kind of command value presetting) by the set ramp time. Thus, a controlled valve does not open abruptly. Ramp generator [4] The ramp generator limits the incline of the control output. The downstream step functions and amplitude attenuators do not extend or shorten the ramp time. Notes for setting and measuring the ramp time: Value at measuring socket "t <" or "t >" U t in V 5 3 2 Current ramp time (±20 %) t in ms 20 33 50 The following applies: t = 100 V ms U t Example: Measured U t = 5 V 100 V ms Results in t = = 20 ms 5 V Characteristic curve generator [5] Using the adjustable characteristic curve generator, step level and maximum values for positive and negative signals can be set separately, adjusted to the hydraulic requirements. The actual development of the characteristic curve through the zero point is not stepped but linear. Amplitude limiter [6] The internal command value is limited to approx. ±110 % of the nominal range. Current controller [7] The solenoid current is recorded, in the current controller compared with the control output and the difference is compensated. Power output stage [8] The power output stage creates the clocked solenoid current for the proportional valve. The solenoid current is limited to 2.7 A per output. The output stage outputs are short-circuit-proof. The output stages are de-energized in case of an internal fault signal or if the release is missing. Clock generator [9] The clock generator creates the clock frequency "f" of the output stages. Using the operating mode selector switch, three basic frequencies can be set: S = 1: f = 150 Hz 400 Hz adjustable S = 2: f = 380 Hz 180 Hz ±15 % (WRA 10) S = 3: f = 350 Hz 240 Hz ±15 % (WRA 6) When setting the WRA valves, the frequency changes depending on the command value and on the operating voltage. U t in V 1 0.5 0.3 0.2 0.1 0.05 0.03 0.02 t in ms 100 200 333 500 1000 2000 3333 5000 Fault recognition [11] The solenoid conductor is monitored for cable break as well as over-current of the output stage. Command value inversion [12] The command value created internally from the input signal and the zero point offset signal can be inverted by an external signal. RE 30228, edition: 2014-01, Bosch Rexroth AG

I 5 VT-MSPA2-1-1X/V0/0 b t > t < wr M0 w (8) t > t < (7) 7 (4) U 8 (2) (3) 9 t U I >50k 10 >50k U ok ok (5) a 6 3 1 2 Zw (10) L0 (12) -1 100 F Gw+ Gw- DC Sw+ Sw- (1) DC +15V +10V M0 10V 15V UL (6) (11) & S 1 2 3 ok f (9) 4 4/8 VT-MSPA2-1 Valve amplifier Block diagram IN+ Command value ±10 V IN Inversion Enable 24 V 0 V Zw Zero point command value t< Ramp time "up" t< Ramp time "down" Sw Step level Gw Amplitude attenuator w Command value wr Command value after ramp Ready for operation Enable 1 Power supply unit 2 Differential amplifier 3 Command value summing device 4 Ramp generator 5 Characteristic curve generator 6 Amplitude limiter 7 Current controller 8 Power output stage 9 Clock generator 10 Enable function 11 Fault recognition 12 Inversion

Valve amplifier VT-MSPA2-1 5/8 Technical data (For applications outside these parameters, please consult us!) Operating voltage U B 24 VDC + 40 % 20 % Operating range: Upper limit value u B (t) max 35 V Lower limit value u B (t) min 18 V Power consumption S < 48 VA Current consumption I < 2 A Fuse Thermal overload protection (with restart if the value falls below the temperature threshold) Inputs: Analog Command value (differential input) U e 0 to ±10 V; R e > 50 kω Digital Enable ON U 8.5 V to U B OFF U 0 to 6.5 V R e > 100 kω Setting ranges: Clock frequency "f" S = 1 150 Hz 400 Hz adjustable S = 2 380 Hz 180 Hz ±15 % (WRA 10) S = 3 350 Hz 240 Hz ±15 % (WRA 6) Zero point command value (potentiometer "Zw") ±30 % Ramp times (potentiometer "t <" and "t >") 20 ms to 5 s Step level (potentiometer "Sw+" and "Sw-") 0 to 50 % Amplitude attenuator (potentiometer "G+" and "G ") 0 to 110 % (applies to the step level setting of 0 %) Outputs: Power output stages I 0 to 2.5 A; short-circuit-proof; clocked Measuring sockets Ramp time "t <" U 20 mv to 5 V Ramp time "t >" U 20 mv to 5 V Actual value "I" U 0 to ±2.5 V (mv ma) Command value "w" U 0 to ±10 V Command value after ramp "wr" U 0 to ±10 V Type of connection 12 screw terminals Type of mounting Top hat rail TH 35-7.5 according to EN 60715 Protection class according to EN 60529 IP 20 Dimensions (W x H x D) 40 mm x 79 mm x 85.5 mm Admissible operating temperature range ϑ 0 to +50 C Storage temperature range ϑ 25 C to +70 C Weight m 0.14 kg Notice: For information on the environment simulation testing for the areas EMC (electro-magnetic compatibility), climate and mechanical load, see data sheet 30228-U. RE 30228, edition: 2014-01, Bosch Rexroth AG

6/8 VT-MSPA2-1 Valve amplifier Terminal assignment +U B 1 7 Operating voltage 0 V 2 8 Enable U F 3 9 IN 4 10 Differential input +IN 5 11 n.c. Inversion INV 6 12 n.c. Solenoid "b" Solenoid "a" Dimensions (dimensions in mm) LED indicators: 79 Ready for operation (green) Enable (yellow) 85,5 7 1 8 9 10 11 12 REXROTH VT-MSPA2-1 f 1 2 3 2 3 Gw+ Gw Sw+ Sw Zw t < t > t < t > I w wr 40 4 5 6 Potentiometers: Gw+ Amplitude attenuator for positive command values Gw Amplitude attenuator for negative command values Sw+ Step level for positive direction Sw Step level for negative direction Zw Zero point command value t < Ramp time for increasing command values t > Ramp time for decreasing command values f Frequency setting Measuring sockets: t < Ramp time "up" t > Ramp time "down" I Actual current value w Command value wr Command value after ramp Measurement zero Operating mode selector switch 1: Gen. application with I max = 2.5 A; f = 150 Hz 400 Hz 2: Frequency optimized for WRA 10 3: Frequency optimized for WRA 6

Valve amplifier VT-MSPA2-1 7/8 Project planning/maintenance instructions/additional information The amplifier module may only be wired when de-energized. Do not lay lines close to power cables. Do not use free-wheeling diodes in the solenoid conductors. The distance to aerial lines, radios, and radar systems has to be 1 m at least. Always shield command value lines; connect shielding to protective earthing (PE) on the module side. Recommendation: Also shield solenoid conductors. For solenoid lines up to a length of 50 m, use cable type LiYCY 1.5 mm 2. For longer lines, please consult us. For switching command values, relays with gold-plated contacts have to be used (low voltages, low currents). Only carry out measurements at the module using instruments with R i > 100 kω. For setting the potentiometers, use a screwdriver with a blade width of 4 mm. With a strongly fluctuating operating voltage, it may in individual cases be necessary to use an external smoothing capacitor with a capacity of at least 2200 μf. Recommendation: Capacitor module VT 11110 (see data sheet 30750); sufficient for up to 3 amplifier modules In the condition as supplied, the setting of the clock frequency corresponds to the requirements of the WRA 6 and WRA 10 valves. Rotating the "f" potentiometer changes the valve hysteresis and may lead to disturbing noise developments. Setting recommendation The system-specific circuitry must have been completed. Signal Command value zero point Ramp times Step level Maximum values Clock frequency: Setting Set the external command value presetting to zero Set the internal command value to zero using the "Zw" zero point potentiometer and carry out a check at the "wr" measuring socket Set ramp time according to formula or table (see functional description "Ramp generator") and check it at the "t >" and "t <" measuring sockets Apply enable signal Using the "Zw" zero point potentiometer, set the measurement signal at "wr" to +0,3 V Using the "Sw+" potentiometer, set the necessary positive step level Using the "Zw" zero point potentiometer, set the measurement signal at "wr" to 0,3 V Using the "Sw-" potentiometer, set the necessary negative step level Set the zero point Notice: With an external command value presetting, it must at least result in +0.3 V / 0.3 V at the "wr" measuring socket. Notice: Before adjusting the maximum values, zero point and step levels must be set correctly. The maximum current must not exceed the rated solenoid current! Set the step levels first; create the command value ±100 % externally Using the "Gw+"/"Gw " potentiometers, set the required maximum control output and carry out a check at the "wr" and "w" measuring sockets Condition as supplied: S = 1: f = 170 Hz S = 2 and "w" = 0: f = 380 Hz S = 3 and "w" = 0: f = 350 Hz Notice: The new setting of the frequency can be carried out with a digital multimeter that is able to measure frequencies. Measure at solenoid terminals 7 against ground 2 and/ or 9 against 2. RE 30228, edition: 2014-01, Bosch Rexroth AG

8/8 VT-MSPA2-1 Valve amplifier Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +49 (0) 93 52 / 18-0 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.