SmartZone-2 & SmartZone-4

Similar documents
INSTALLATION INSTRUCTIONS At Air-Handler Location

Smartzone LCD TOUCHPAD USER GUIDE.

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION

Model 12200A RCN PTAC/PTHP/FAN COIL CONTROL NODE OPERATION OUTPUTS G1 = FAN 1 G2 = FAN 2 G3 = FAN 3 O/B = Rev Valve W = HEAT Y = COMPRESSOR

ELECTRONIC THERMOSTAT: T920

IRRIGATION 810-3R RECEIVER GUIDE

ELECTRONIC THERMOSTAT: T951

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting

Wireless Temp/Setpoint & Override Room Transmitter

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

Wireless Rain and Wireless Rain/Freeze Sensor

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions

Industrial Pipe Marking

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

Guidelines to Using a Three Phase Voltage Monitor

TLC3-BCR-U Series Thermostat

Installation Instructions

OWNERS MANUAL FOR STERLING SERIES CONTROLLERS

Setup Guide. support.spruceirrigation.com.

Installation of Fillmaster DuraBlue Melters. System on. Introduction. Instruction Sheet P/N B

CONTENTS Installation Location

TE-7800 Series One-to-One Wireless Room Temperature Sensing System

TECHNICAL PRODUCT DATASHEET

BFS / BFSM SERIES Installation & Maintenance Manual

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Honeywell. W7620 Zone Controller Water Source Heat Pump A. GENERAL RESIDENTIAL AND BUILDING CONTROL GUIDE SPECIFICATION FOR THE ENGINEER

EUROSTER 2026/2026TX

MULTISTACK The Modular Water Chiller

REFERENCE AIRBASS Wireless Subwoofer Volume Control System

C0330, C0530, C0630, C0830, C1030 Service Parts

Digital Room Sensor Technical Guide

Universal Controller

Installation and Operation Manual

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

RWD44U Controller. Installation and Commissioning Guide Document No October 5, Function. Application

CONTENTS Installation Location

Multiple Program Process Temperature Controller. Installation Guide Maxitrol Company, All Rights Reserved

SE8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller

CONTROL MANUAL. Dry-Pic 09PE - 09VE

C0330, C0530, C0630, C0830, C1030 Service Parts

Operating Instructions

Connect + compatible

Installation Guide. Contents. VT7600E Series RTU Terminal Equipment Controller with IAQ Control

Self-learning Room Temperature Controller Receiver

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

SECTION MECHANICAL IDENTIFICATION

W7100A-E Discharge Air Controller

Installation Instructions

Technical Information

RWD68U Controller. Installation and Commissioning Guide Document No October 1, Function. Application

PWM. Design, Installation, and Operation. (Pulse Width Modulation Zone Controller)

AURATON 2020 AURATON 2020 TX RX Plus

BOILER MANAGEMENT SYSTEM

ADDENDUM NO. 4 November 15, Page 1

VT8300 Series Installation Guide 24 Vac Low Voltage

INSTALLATION INSTRUCTION Supersedes: N1.8Y (399) N1.8Y (699)

1 Digital input (24Vac or dry contact) Inputs

EVERGREEN EM INSTALLATION GUIDE

- Wiring Brochure Universal Reset Module 423e

S ENSORLINK INSTALLATION MANUAL

User Manual. ProRF Encoder Transmitter & Receiver

R PROFLAME Instruction Book Collection

Option Setting Level #1 Programming Chart For Standard Valves. Regeneration Time Example: 2:00 A.M. [ 2:00]

Table 1. Placing the Sensor in the Sensor Cradle. Step Instruction Illustration

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor

User s Guide Instructions for Installation and Operation

Programmable Process Temperature Controller

TC 204 Heating Controller

MODEL 421 Over/Under Motor Load Monitor

ETC Installation Guide

Fan Coil Actuator FCA 2

E-BUS Digital Room Sensor Technical Guide

AEROCONNECT 1B NA C Control manual

Communicative heating controller

INTAC Microprocessor Humidifier Controller

ET Water SmartWorks Panel Installation Guide

Rev RF Service Tool Operator s Guide

SE7600F Series. RTU Terminal Equipment Controller with Modulating Heat. Installation Guide For Commercial HVAC Applications CONTENTS.

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION

Home Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description

Parts. Backplate. Battery Cover. Backup Key. Touchscreen Assembly. Inside Assembly. Thumbturn. Strike. Reinforcement Plate. Bolt.

Actuator ICAD 600A / ICAD 600A-TS / ICAD 1200A

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

Intelligent Compact Controller

VT8600 Series User Interface Guide Rooftop Unit, Heatpump and Indoor Air Quality Controller

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

Photoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Wireless Analog Output Modules

Manual BC20 Control Service Guide

NEW DIGITAL PUMP LOAD CONTROL

Metasys Zoning Package Commissioning

LT3000 ULTRASONIC LEVEL TRANSMITTER

The Ins and Outs of Basic. A practical approach to reading and understanding the schematic diagrams used to explain how HVACR systems operate.

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

Wireless Room Thermostat Installation and Operation Y6630D1007

Wireless multizone receiver RDE-MZ6

Transcription:

SmartZone-2 & SmartZone-4 Quick-Start Guide UPDATED 2011-7-26 This guide is intended to give the installer a brief set of instructions about how to set up the XCI Zoning SmartZone System. For more detailed information about the SmartZone Controller, refer to www.xcicontrols.com >products> zone controller> SmartZone System Manual. In this document, SmartZone-4 and SmartZone-2 will be referred to as SmartZone. Mounting 1. Remove the clear lid from the SmartZone Enclosure. 2. Using pliers, break out the necessary knock-outs for wiring on the side of the gray base of the SmartZone Enclosure. NOTE: If using the holes on the back of the enclosure for surface mount wiring this may not be necessary. 3. Using flat or pan-head screws (at least 2); mount the gray base of the SmartZone Enclosure on a flat surface. 4. After wiring is completed, replace the clear lid. Power The SmartZone System requires a separate 24VAC transformer for powering the SmartZone Controller Board, Zone Thermostats and Dampers. Connect 24VAC and 24VAC(c) to the POWER Connector on the bottom left of the SmartZone Controller Board. SmartZone-4 TRANSFORMER SIZE = 22VA (for Controller and 4 Thermostats) + 10VA (per Damper) OR 3VA (per POC and RPOC damper). [Example 1: A system with 4 SZD Dampers, the transformer needs to be greater than 62VA] [Example 2: A system with 4 POC (or RPOC) Dampers, the transformer needs to be greater than 34VA] SmartZone-4 (with 3 Zones) TRANSFORMER SIZE = 20VA (for Controller & 3 Stats) + 10VA (per SZD Damper) OR 3VA (per POC and RPOC damper). [Example 1: If the system has 3 SZD Dampers, the transformer needs to be greater than 50VA] [Example 2: A system with 3 POC (or RPOC) Dampers, the transformer needs to be greater than 29VA] SmartZone-2 TRANSFORMER SIZE = 18VA (for Controller and 2 Thermostats) + 10VA (per SZD Damper) OR 3VA (per POC and RPOC damper). [Example 1: If the system has 2 SZD Dampers, the transformer needs to be greater than 38VA] [Example 2: A system with 2 POC (or RPOC) Dampers, the transformer needs to be greater than 24VA] XCI Zoning Page 1 of 12 P/N 230101-03

Wiring Thermostats Wiring SmartZone will operate using thermostats that have a common or are battery operated, follow the below steps to connect each of the thermostats to the SmartZone Controller Board. 1. Connect either single stage heat pump thermostats or gas/electric thermostats to each terminal block labeled THERMOSTAT 1 through 4. 2. The THERMOSTAT 1 will operate ZONE 1 damper, THERMOSTAT 2 will operate ZONE 2 damper and so on through THERMOSTAT 4. 3. Hold down the orange button adjacent to the terminal openings and push the thermostat wires into SCREWLESS terminals labeled R,C,Y,G,W and O/B (as applicable). 4. Connect the other end of the thermostat wire to the thermostat for the associated ZONE. XCI Zoning Page 2 of 12 P/N 230101-03

Damper Wiring When using Power Close/Spring Open dampers follow the steps below to connect each of the dampers to the SmartZone Controller Board: 1. Use 18/2 or 18/3 solid core wire 2. Hold down the orange button adjacent to the terminal block openings labeled Z1-PC and COM and push wires for the ZONE damper into the SCREWLESS terminals. 3. Connect the other end of the wire to the SCREWLESS terminals on the ZONE damper. If using a Power Open/Power Close damper follow the steps below to connect each of the dampers to the SmartZone Controller Board: 1. Use 18/3 solid core wire 2. Hold down the orange button adjacent to the terminal block openings labeled Z1-PC, COM and Z1-PO and push wires for the ZONE damper into the SCREWLESS terminals. 3. Connect the other end of the wire to the SCREWLESS terminals on the ZONE damper. Supply Air Temperature Sensor [SA Sensor] Wiring Sensor Placement (Location) Gas/Electric and Dual Fuel Sensor should be located in Supply Air Plenum where it will sense AVERAGE air temperature within the plenum. The most ideal placement for the Sensor will be 2 to 4 feet beyond the evaporator. Make sure the sensor is in the air stream and secured properly. Heat Pump The sensor is placed inside the cabinet of the air handler after the coil but before the blower. Make sure the sensor is in the air stream and secured properly. Sensor Wiring Using the provided GREEN connector (Factory Connected to Sensor Wire) plug the SA Sensor wire into the SmartZone Controller Board. NOTE: WITHOUT THIS SENSOR, THE SmartZone CONTROLLER BOARD WILL NOT OPERATE. XCI Zoning Page 3 of 12 P/N 230101-03

Note: On standard heat pumps with electric air handlers, SAS is located in air handler between indoor coil and blower. Equipment Wiring Connect the Equipment Control Wires from the Unit to the EQUIPMENT Terminal Block on the Top Right of the SmartZone Controller Board. Use the terminal labeled W1 EH for 1st stage heat when using gas/electric equipment or emergency heat on heat pump. Use the terminal labeled W2 O/B on 2 nd stage heat on gas/electric equipment. Use the terminal labeled W2 O/B for reversing valve when using heat pump. NOTE: THE C TERMINAL MUST BE CONNECTED TO THE CONTROLLER AND EQUIPMENT IN ORDER FOR THE EQUIPMENT RELAYS TO ENERGIZE. POWER FROM THE EQUIPMENT TRANSFORMER WILL ILLUMINATE THE RC AND RH TERMINAL LEDs INDICATING THE EQUIPMENT TRANSFORMER IS CONNECTED. *See next page for wiring diagrams. XCI Zoning Page 4 of 12 P/N 230101-03

GAS-ELECTRIC SYSTEM WIRING HEAT PUMP SYSTEM WIRING XCI Zoning Page 5 of 12 P/N 230101-03

Configuration DIP Switches ALL of these DIP Switches MUST BE SET according to the equipment type, thermostats being used as well as the desired functionality of the SmartZone System. If not, unpredictable and undesirable results may occur. See the table below for DIP Switch descriptions. DIP #1 DIP #2 NORMAL DUAL FUEL ALL Z1 PRIORITY Operates electric auxiliary heat with compressor. (Factory Default) Operates gas auxiliary heat with NO compressor HEAT PUMP ONLY. Allows any thermostat to change equipment mode. (Factory Default) Allows ZONE 1 to control equipment mode unless satisfied. DIP #3 DIP #4 15 MIN 15 Minute delay between opposing calls. (Factory Default) 10 OP CALL 10 Minute delay between opposing calls. 2 nd STAGE Normal Operation 2 nd Stage is always active. (Factory Default) LOCK OUT Will not Allow 2 nd Stage if only one ZONE is calling. DIP #5 DIP #6 REV VLV O B SYS G/E HEAT PUMP Reversing valve is energized in COOLING. (Factory Default) Reversing valve is energized in HEATING. Gas/Electric or Electric/Electric Equipment. (Factory Default) Heat Pump Equipment ONLY. XCI Zoning Page 6 of 12 P/N 230101-03

Configuration (Continued) Push Buttons The push buttons are used for several different functions. See descriptions below for information on how to use the buttons to setup and view SmartZone Controller settings. Fresh-Air Damper Time To set the Minutes-Per-Hour that the Fresh-Air Damper is OPEN follow the below steps: 1. While the SmartZone Controller Board is powered, press and quickly release BOTH the UP and DOWN Arrow buttons at the same time. The Green FRESH AIR indication will begin to flash. 2. Within 5 seconds press either the UP or the DOWN Arrow button to change the time. The time is indicated in Number of Minutes-Per-Hour that the Fresh-Air Damper will be OPEN. 3. After the desired time has been selected, wait 5 seconds and ST will flash on the Display, indicating that the time has been set. NOTE: If NO Fresh Air Damper is installed, 0 (Zero) Time must be set or the equipment fan will run unnecessarily. Electronic Limit Control TM (ELC) To set the High and Low Temperature Equipment Cut-Out SetPoints follow the below steps, before completing these steps, ensure that DIP #6 is set correctly choosing the proper equipment type. HIGH Temperature Cut-Out (Factory Default - GAS/ELECTRIC = 135 F; HEAT PUMP = 120 F) 1. While the SmartZone Controller Board is powered, press momentarily and release the UP arrow to set the HIGH Temperature Cut-Out. The Red HI TEMP indication with begin to flash. 2. Within 5 seconds press either the UP or the DOWN Arrow button to change the HIGH Temperature Cut-Out. The temperature indicated here represents the highest temperature allowed at the supply air sensor. 3. After the desired temperature has been selected, wait 5 seconds and ST will flash on the Display, indicating that the HIGH Temperature Cut-Out has been set. LOW Temperature Cut-Out (Factory Default - GAS/ELECTRIC = 48 F; HEAT PUMP = 48 F) 4. While the SmartZone Controller Board is powered, press momentarily and release the DOWN arrow to set the LOW Temperature Cut-Out. The Red LO TEMP indication with begin to flash. 5. Within 5 seconds press either the UP or the DOWN Arrow button to change the LOW Temperature Cut-Out. The temperature indicated here represents the lowest temperature allowed at the supply air sensor. 6. After the desired temperature has been selected, wait 5 seconds and ST will flash on the Display, indicating that the LOW Temperature Cut-Out has been set. XCI Zoning Page 7 of 12 P/N 230101-03

Configuration (Continued) Dual Fuel (Gas Furnace add on to heat pump) Applications Note 1: Note 2: A DUAL FUEL KIT IS NOT REQUIRED and HEAT PUMP THERMOSTATS ARE NOT REQUIRED ON #2, #3, AND #4 ZONES. Use Heat Pump stat in the #1 ZONE ONLY for EMERGENCY HEAT. When using the TSZ-1 thermostat, use the Wireless Outdoor Temperature Transmitter (Part #TOS) with the TSZ-1 thermostat to control emergency heat mode using outdoor temperature through the heat pump thermostat in the #1 position. Always install the heat pump evaporator downstream of the furnace. This prevents condensation in the heat exchanger during the cooling mode. 1. The HIGH Temperature Cut-Out for the gas furnace in a dual fuel application can only be identified and adjusted when the # 6 dipswitch is in the GAS FURNACE position. 2. The HIGH Temperature Cut-Out for the heat pump in a dual fuel application can only be identified and adjusted when the # 6 dipswitch is in the HEAT PUMP position. 3. The LOW Temperature Cut-Out for the HEAT PUMP in a dual fuel application is the same as described earlier on page 6 (LOW Temperature Cut-Out). Thermostat Type NOTE: THIS ONLY APPLIES TO HEAT-PUMP INSTALLATIONS To set type of Thermostat being used on the system follow the below steps: 1. While the SmartZone Controller Board is powered, press AND HOLD both the UP and DOWN Arrow buttons until the Numeral 1 appears [this Numeral is an indication of the ZONE Thermostat number], then either GE or HP will appear on the display. 2. Within 5 seconds press the DOWN Arrow button to toggle between the thermostat types. GE = Gas/Electric Thermostat; HP = Heat Pump Thermostat 3. After the desired thermostat type has been selected for this ZONE, press the UP arrow (within 5 seconds) to select the next zone. The Numeral 2 will appear [this Numeral is an indication of the ZONE Thermostat number], then either GE or HP will appear on the display. 4. Repeat Steps 2 and 3 for each of the ZONEs being used. 5. After all thermostat types have been selected for each ZONE, wait 5 seconds and ST will flash on the Display indicating that the Thermostat Type has been set. NOTE: For Emergency Heat to be utilized, Zone #1 MUST have a Heat Pump thermostat connected. RC/RH Jumper The RC/RH Jumper is Factory Installed on the SmartZone Controller Board. If the system being used requires separate Heat and Cool Transformers, REMOVE this jumper [JP2] at the top right of the board. Note: In the case of a Heat-Pump System, this Jumper ALWAYS needs to be installed. XCI Zoning Page 8 of 12 P/N 230101-03

Operation Equipment LEDs Diagnostic LEDs indicate which equipment circuits are energized with 24VAC. When no R LED is on, check power from the HVAC unit. Thermostat LEDs Each LED indicates what mode is being powered through the thermostat. The Red LED adjacent to R indicates SmartZone has power available for the thermostat. The Yellow LED adjacent to Y indicates a compressor call from the thermostat. The Green LED adjacent to the G indicates Fan call from thermostat. The Red LED adjacent to the W indicates a Heat call from thermostat. The Red LED adjacent to the O/B indicates Reversing Valve call from thermostat. Damper LEDs Red LED indicates damper is powered closed. Green LED indicates damper is open. Emergency Heat Lock This feature has been implemented to ensure that once the system has been set to Emergency Heat (EH), the compressor will not be energized until the system has been taken out of EH mode. ONLY Zone#1 Thermostat can set the equipment into EH mode. Zone#1 Thermostat must be making a call for EH to set the SmartZone-2 or -4 into EH mode. Once the SmatZone-2 or -4 has been set into EH by Zone#1 Thermostat, it is Locked in EH mode and will not make any compressor calls until it has been UN-Locked Any cooling calls from thermostats other than Zone#1 thermostat will be ignored while in EH Lock mode. Any heating calls from thermostats other than Zone#1 will be treated as EH calls while in EH Lock mode. To UN-Lock EH mode, a call must be made from the Zone#1 thermostat for anything other than EH. o NOTE: Zone#1 Thermostat must not only be switched out of EH mode but ALSO must MAKE a call for another mode (either Heat-Pump Heat or Cool). If no call is made from Zone#1 Thermostat then the SmartZone-2 or -4 will remain in EH Lock until Zone#1 does make a call no matter what the other zones are calling for. Time Delay After all calls have been satisfied and the equipment is turned off, all dampers open and a 3-minute Time Delay will start during which the equipment cannot be energized. This is designed to protect the equipment from re-starting for 3-minutes after it has stopped running. During the 3-minute Time Delay, the SmartZone Controller will not energize the fan. However, the fan may continue to run if the equipment being used has a built in off-time-delay. NOTE: There is NO visual indication of the Time Delay on the SmartZone Controller other than the fact that there will be no equipment calls regardless of what the thermostats call for during the 3-minute duration. Purge The Purge Mode is a three-minute time period that allows the blower to continue to operate during Opposing Call Changeover. During the Purge, no heating or cooling equipment will be energized. Purge mode is designed to prevent equipment from operating for three minutes so that HVAC system pressures and temperatures can equalize. During the three-minute Purge Mode, zones with calls for the opposite mode that was last being satisfied will have dampers closed. All other dampers (ones associated with non-calling zone(s) and last zone(s) being satisfied) will remain open during Purge Mode. XCI Zoning Page 9 of 12 P/N 230101-03

Equipment Staging Cooling Air Conditioning and Heat Pump: First stage occurs any time there is a call for cooling or a changeover from heating to cooling. Y1 and G are energized. In heat pump cooling mode OB may also be initiated. After 8 minutes of initial run time in first stage, the ELC (Electronic Limit Control) will initiate Y2 if the supply air temp has not dropped below 10 degrees above the Low Temp Cut-Out temperature. Once second stage is initiated, if the supply air temp goes below 4 degrees above the Low Temp Cut- Out, Y2 is de-energized and only Y1 and G are energized. This scenario is repeated as dictated by the supply air temp. Heating Gas, Electric and Fuel Oil Heating First stage occurs anytime there is a call for heating or a changeover from cooling to heating. W1/EH and G are energized. After 8 minutes of initial run time in first stage, the ELC will initiate W2/OB if the supply air temp has not risen above 25 degrees below the High Temp Cut-Out temperature. Once second stage is initiated, if the supply air temp rises above 10 degrees below the High Temp Cut-Out, W2/OB is de-energized and only W1 and G are energized. This scenario is repeated as dictated by the supply air temp. Heat Pump Heating with Electric Backup First stage occurs anytime there is a call for heating or a changeover from cooling to heating. Y1 and G are energized. In heat pump heating mode OB may also be initiated. After 4 minutes of initial run time in first stage, the ELC will initiate Y2 if supply air temp has not risen above 15 degrees below the High Temp Cut-Out temperature. Once second stage is initiated, if the supply air temp rises above 5 degrees below the High Temp Cut-Out, Y2 is de-energized and only Y1 and G are energized. Auxiliary Heat - After 6 minutes of initial run time, if the supply air temp drops below 90 degrees, W1/EH will be energized. If the supply air temp rises above 100 degrees W1/EH will be de-energized and only Y1, Y2 and G will be energized. This scenario is repeated as dictated by the supply air temp. Emergency Heat - can only be initiated thru a heat pump stat in the # 1 position. If this stat is placed in Emer Heat, the SmartZone board is latched into emergency heat. No compressor will run and only heating calls will be recognized. Remove the Emer Heat call at stat #1 and make a call for something other than Emer Heat from stat #1 in order to unlatch the board and take it out of emergency heat. Heat Pump Heating with Fossil Fuel Backup (Dual Fuel) First stage occurs anytime there is a call for heating or a changeover from cooling to heating. Y1 is energized. In heat pump heating mode OB may also be initiated. After 4 minutes of initial run time in first stage, the ELC will initiate Y2 if supply air temp has not risen above 15 degrees below the High Temp Cut-Out temperature. Once second stage is initiated, if the supply air temp rises above 5 degrees below the High Temp Cut-Out, Y2 is de-energized and only Y1 is operating. This scenario is repeated as dictated by the supply air temp. Auxiliary Heat - After 6 minutes of initial run time, if the supply air temp drops below 90 degrees, W1/EH will be energized. This will remove Y1 and Y2 and energize W1/EH. W1/EH will initiate start up of the fossil fuel furnace. Only the W1/EH and G will remain energized for the remainder of the heating cycle. Emergency Heat - can only be initiated thru a heat pump stat in the # 1 position. If this stat is placed in Emer Heat, the SmartZone board is latched into emergency heat. No compressor will run and only heating calls will be recognized. Only the W1/EH and G will remain energized for the remainder of the heating cycle. Remove the Emer Heat call at stat #1 and make a call for something other than Emer Heat from stat #1 in order to unlatch the board and take it out of emergency heat. XCI Zoning Page 10 of 12 P/N 230101-03

Operation (Continued) Display Display Indicator HI TEMP LO TEMP SUPPLY FRESH AIR PURGE Status Flashing ON OFF Flashing ON OFF Flashing ON OFF Flashing ON OFF ON OFF Description During adjustment of HIGH Temperature Cut-Out (described above) Supply Air Temp has been above HIGH Temp Cut-Out in the last 3 minutes Normal Operation (Supply Air Temp is below HIGH Temp Cut-Out) During adjustment of LOW Temperature Cut-Out (described above) Supply Air Temp has been below LOW Temp Cut-Out in the last 3 minutes Normal Operation (Supply Air Temp is above LOW Temp Cut-Out) Indicates that NO Supply Air Temp Sensor is Connected to SmartZone Normal Operation (Indicates the Temp displayed is the Supply Air Temp) During adjustment of Thermostat Types (described above) During adjustment of Fresh-Air Damper Time (described above) Indicates that the Fresh-Air Damper is OPEN Indicates that the Fresh-Air Damper is CLOSED During System Purge and Opposing Call Changeover Indicates NO Purge condition http://www.xcicontrols.com 1-866-XCI-HVAC 1-866-924-4822 XCI Zoning Page 11 of 12 P/N 230101-03

The thermostat wiring on this diagram is intended as a general guide; refer to the installation guide provided with the thermostat being used for specific wiring information. XCI Zoning Page 12 of 12 P/N 230101-03