Acrowall-60 General Technical and Application Manual

Similar documents
February 2004 RONDA. Circular Formwork Instructions for assembly and use

User Guide MEGAFORM 02FAR14

Acrow Slim-Lite Soldier System

PERFORM WITH PRECISION MAX A FORM STS FORMING SYSTEM CONCRETE CONSTRUCTION PRODUCTS APPLICATION GUIDE

MEP Shoring System Technical Instruction Manual

Lok Fast Column Clamp General Information

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7

System 3000 specifications

BEST PRACTICE GUIDE. Socket Bases. Working with Concrete Slabs

H20 Beam for Elevated Slabs Application Guide

DUTCH GABLE FREESTANDING CARPORT

Experience the Hi-Lite Advantage

MevaDec. Contents. Ref. No. Description / Application Product m² list kg

INSTALLATION INSTRUCTIONS

PUSH-PULL-PROPS. and accessories ROBUSTA-GAUKEL GMBH MOUNTING TECHNOLOGY &CO.KG

Big expertise. Real convenience. Concrete commitment. stem

MM750 Installation Instructions

Segmental ring types provided by F P McCann: Segments in stock are front bolted. Back bolted segments are available to order: Cross joint Corbel Ring

INSTALLATION INSTRUCTIONS

Meva Guided Screens MGS Technical Instruction Manual

RAPID-EPS SAFETY INSTRUCTIONS AND INSTALLATION GUIDE. American Standard OSHA

INSTALLATION INSTRUCTIONS

How to Use the Jahn Forming System

Mounting Instructions Item No.: xxx

6.1. PUSH-PULL-PROPS and accessories

Multi-Stage ASSEMBLY INSTRUCTIONS ST-8100 SERIES. 125 TAYLOR PARKWAY ARCHBOLD, OH PHONE: (419) FAX: (419)

Taurean Sectional Garage Door INSTALLATION INSTRUCTIONS

Leveling Feet, Base Plates and Casters

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Installation Instructions

aluminium profile system

SPACE-LIFT DAYTONSUPERIOR.COM APPLICATION GUIDE. Jump Forming System

INSTALLATION INSTRUCTIONS

CURVED ROOF ASSEMBLY INSTRUCTIONS ATTACHED VERANDAH. Your supplementary guide to building an ATTACHED CURVED ROOF VERANDAH or PATIO BEFORE YOU START

Steel Frame Assembly

Please read and understand the OnBoard Timpani Cart Owner s Manual before using the Timpani Cart.

Installation Instructions - Model V4JSD 1

Installation Instruction

INSTALLATION INSTRUCTIONS

======================================================================================== ( DR / DR) JK WRANGLER MOD RACK

Mobile Weapons Storage System Specifications

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

THE POWER OF RED STEEL-PLY CONCRETE FORMING SYSTEM APPLICATION GUIDE

THE POWER OF RED SPACE-LIFT CONCRETE CONSTRUCTION PRODUCTS APPLICATION GUIDE

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

HD installation guide

MEP Shoring System Technical Instruction Manual

Installation Instructions for Vista Air Vertically Folding Walls

SM-RAZOR-ART2-L / SM-RAZOR-ART2-XL

Imperial Technical Instruction Manual

Assembly Instructions 10 X 10 Aluminum Roof Support

PANEL CRIB PIERS AND TOWERS

TRADITIONAL GABLE ATTACHED PATIO AND CARPORT. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT

Evorail Guardrail has Evolved

ASSEMBLY INSTRUCTIONS TF Tent Flooring System. 125 Taylor Parkway Archbold, Ohio Phone: (419) Fax: (419)

HANDLING AND ASSEMBLY INSTRUCTIONS FOR TRUE FOCUS 3.0M, 3.8M AND 4.2M ANTENNAS WITH POLAR MOUNT

Assembly Instructions

AWNING / PATIO COVER INSTALLATION INSTRUCTIONS

ALDoor DOUBLE DOOR INSTALLATION

PRE-ENGINEERED HORSE STALL SYSTEMS SDFD SLIDING DOOR c/w FOLD-DOWN GRILL. & Assembly. Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

Sure-P ure l -P y l APP A lic PP A lic tion A G tion uide G

ALL SEASON PATIO COVER

Pickup Box Utility Rack Package Installation (Instruction ID: )

Products for fixing to Steelwork and Decking

Scaffolding ACCESSORIES

HV Support System. The HV Support System is compatable with all CSS Support Systems:

Sure-P ure l -P y l APP A lic PP A lic tion A G tion uide G

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

Vertical Offset Base and Safety Rail System Installation Instructions

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

BUMP GATE FITTING INSTRUCTIONS.

PFW 6875 Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

PFW Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

ASSEMBLY INSTRUCTIONS

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

installation guide

FORPARK AUSTRALIA

Fitting instructions for (Read instructions fully, before installing the door)

INSTALLATION INSTRUCTIONS LARGE FLAT PANEL IN WALL ENCLOSURE Model: PAC-500

southpaw enterprises, inc.

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02

3 BRACKET TO GUIDE ATTACHMENT. RIGHT END Figure 1. EXTENDED BRACKET (for doors taller than 8-8 ) SERIES 650. RIGHT END COTTER PIN Figure 6

ASSEMBLY INSTRUCTIONS

Windload Post 9100/9600/9900 Installation Instructions

Small Above Fireplace Pull-Down Full-Motion TV Wall Mount

Gared Pro-S Portable Backstop

CEILING-MOUNTED MONORAIL ANCHOR TRACK SYSTEM Assembly and Operation Instruction Manual

CRYSTEEL S. this manual must be included with the vehicle after completing the installation.

Simotec. 13.i

400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS

INSTALLATION INSTRUCTION RRU DOUBLE LIGHT POLE MOUNT

Strong, lightweight composite structural I -Beam.

Pocket Door Kit PD1 / PD2 Installation Instructions. Kit Contents.

Obtained from Omarshauntedtrail.com

INSTALLATION INSTRUCTION

Transcription:

FORMWORK PRODUCT Technical Guide Acrowall-60 General Technical and Application Manual Genuine Safety. Outstanding Service.

Acrowall-60 Formwork System Important The erection and application instructions contained in this booklet are the recommended methods to be used for Acrowall products. The technical function related instructions must be accurately followed to obtain the correct workability of the product. Any deviation from the recommended usage will require a separate design and/or verification by Acrow Formwork & Scaffolding (AF&S) Engineering Department. The safe use and application of the Acrowall system must be in accordance with Australian Standard AS 3610 Formwork for Concrete, Occupational Health and Safety Regulations, approved industry codes of practice and relevant regulatory authority requirements. The illustrations in these assembly configurations are minimum guidelines only. The combined use of the Acrowall system with equipment from other suppliers may entail performance problems and therefore requires a design check and/or verification by AF&S Engineering Department. Safe Work Methods Statements and Hazard Identification/Risk Assessments for the erection and dismantling of the Acrowall system are available from AF&S Branches. Site specific Hazard and Risk assessments may need to be generated for specific projects. Safety Warning This warning is to draw the users attention to possible musculoskeletal disorder as a result of manual handling during assembly and dismantling of Acrowall panels. It is recommended that users of the Acrowall panel system employ and implement appropriate procedures and control measures to eliminate or control any risk of Musculoskeletal disorder/injury while manually handling Acrowall panels Refer to Code of Practice on manual handling published by local Workcover Authority or other approved and recognised guidelines for correct and appropriate manual handling procedures. Product Features Acrowall is a galvanised steel frame panel with a 14mm plywood face. The panel weight of a 2700 x 750 panel is only 60kg. Panels up to 2700 x 750 may be manually handled or built into a large crane handled assembly for fast movement of formwork. The maximum permissible concrete pressure is 60kPa for single panel height form arrangements up to 2.7m or 55kPa for height extended form arrangements. The built-in strength in the design of the Acrowall system makes the assembly simple with a minimum of components. The aligning clamp locks the panels rigidly together and accurately in line. Panel assemblies stay free of twist even when being crane handled. 2 Disclaimer 1 Photographs/illustrations shown within this brochure are intended as expressing the diversity and possible applications of the product and as such must not be used as assembly instructions. 2 In line with Acrow Formwork & Scaffolding Pty Ltd's commitment to continuous product development and improvement, the information contained in this brochure may be changed without notice. 3 Every effort has been made to give appropriate guidelines for the use of this product, however, Acrow Formwork & Scaffolding Pty Ltd accepts no responsibility for any loss or damage suffered by any person acting or refraining from action as a result of this information. Should the users require any further information or guidance, they are encouraged to contact their local Acrow Formwork & Scaffolding Pty Ltd outlet.

General Technical and Application Manual Product Description Code No. Mass kg (nom.) 300-900 Acrowall Panels Can be connected to each other to form the required concrete area. They are capable of taking a concrete pressure of 60kPa for a single panel high construction or 55kPa where multiple panels are used in height. Approximate weight is 30kg/m². Tie Positions 1520 2700 Acrowall Panel 2700 x 900 Acrowall Panel 2700 x 750 Acrowall Panel 2700 x 650 Acrowall Panel 2700 x 600 Acrowall Panel 2700 x 550 Acrowall Panel 2700 x 500 Acrowall Panel 2700 x 450 Acrowall Panel 2700 x 300 ACP2790 ACP2775 ACP2765 ACP2760 ACP2755 ACP2750 ACP2745 ACP2730 69.1 60.6 55.9 53.2 50.9 48.4 45.4 38.9 300-900 120 300-900 1165 35 Acrowall Panel 1500 x 900 Acrowall Panel 1500 x 750 Acrowall Panel 1500 x 650 Acrowall Panel 1500 x 600 Acrowall Panel 1500 x 550 Acrowall Panel 1500 x 500 Acrowall Panel 1500 x 450 Acrowall Panel 1500 x 300 AWP1 AWP1575 AWP1565 AWP1560 AWP1555 AWP1550 AWP1545 AWP1530 41.4 35.9 32.8 31.1 29.8 28.2 26.5 22.6 300 868 32 1200 120 300 1500 Acrowall Panel 1200 x 900 Acrowall Panel 1200 x 750 Acrowall Panel 1200 x 650 Acrowall Panel 1200 x 600 Acrowall Panel 1200 x 550 Acrowall Panel 1200 x 500 Acrowall Panel 1200 x 450 Acrowall Panel 1200 x 300 AWP1290 AWP1275 AWP1265 AWP1260 AWP1255 AWP1250 AWP1245 AWP1230 38.0 33.5 30.2 29.2 27.3 25.5 24.0 18.7 120 2400 Acrowall Extra Large Panel 2700 x 2400 With a form surface area of 6.48m², this panel reduces the need for large numbers of ties and connectors. Only 4 ties are required. When used for single-sided walls, the 4 tie holes must be plugged with the Acrowall Panel Plug (AWPP). The panel can be used either horizontally or vertically. AWP2724 283.7 1520 2700 3 120 540 1320 540

Acrowall-60 Formwork System Product Description Code No. Mass kg (nom.) 300 Acrowall Internal Corner Panels The 90 internal corner has a feature which enables the angle to be reduced by 2 to provide clearance to assist in stripping. Unlocking the corner stiffeners enables the panel to move inwards stripping the form away from the concrete. 2700 2 0 1500 1200 Corner stiffener unlatched Acrowall ICP 2700 x 300 x 300 Acrowall ICP 1500 x 300 x 300 Acrowall ICP 1200 x 300 x 300 AWIC2730 AWIC1530 AWIC1230 66.2 37.9 30.6 150 Acrowall Hinged Corner Panels 150 x 150 The 150 x 150 wide panel can be used on obtuse corners and has a range of rotation between 90 and 300. Due to its shape, the panel will not close beyond 90 so can not be used for acute angled internal corners. 2700 Acrowall Hinged CP 2700 x 150 x 150 Acrowall Hinged CP 1500 x 150 x 150 AWHC2715 AWHC1515 49.2 27.8 1500 1500 1200 150 x 150 HCP 300 Acrowall Hinged Corner Panels 300 x 300 The 300 x 300 wide panel is suitable for corners from 60 to 150. Acrowall Hinged CP 2700 x 300 x 300 Acrowall Hinged CP 1500 x 300 x 300 Acrowall Hinged CP 1200 x 300 x 300 AWHC2730 AWHC1530 AWHC1230 77 41.4 33.9 4 2700 150 x 150 HCP 1500 1200 300 x 300 HCP

General Technical and Application Manual Product Description Code No. Mass kg (nom.) Tie Positions 700 1520 2700 700 300 1162 38 1500 120 Acrowall Multi-purpose Panels A multi-purpose panel featuring a series of tie holes spaced at 50mm horizontal increments. The tie holes allow the panel to be used for special applications such as wall offsets and corners with oblique angles. It is particularly suitable for 150mm to 550mm columns. Acrowall MP Panel 2700 x 700 Acrowall MP Panel 1500 x 700 Acrowall MP Panel 1200 x 700 AWMP2770 AWMP1570 AWMP1270 60.1 39.2 35.5 120 700 300 862 38 1200 350 Acrowall Aligning Clamp The Aligning Clamp when used positioned along the panel ribs tightly joins two panels together and aligns them in one action, eliminating the need for walers or other joint clips. If used between rib positions it will not align panels but only join them. See pages 11-13. AWAC 2.9 550 Acrowall Adjustable Aligning Clamp The Adjustable Aligning Clamp is used where timber infills are fitted between panels (max 150mm). The clamp can also be used to join a horizontal panel to a vertical panel at a rib position on the horizontal panel. See pages 11-13. AWAAC 5.0 360 260 Acrowall Outer Corner Clamp The Outer Corner Clamp provides a strong positive right angled corner with the ability to cater for timber infills of up to 60mm. AWOCC 6.1 5

Acrowall-60 Formwork System Product Description Code No. Mass kg (nom.) 765 Acrowall Platform Bracket The Platform Bracket can be attached to horizontal or vertical panels. It provides room for 3 timber planks, which are secured to the top flange of the bracket via 6 existing Ø12 holes. AWPB3 13.5 Guardrail Post The Guardrail Post fits into the end socket of the platform bracket to provide the facility to connect a tube and coupler guardrail. The Guardrail Post is secured to the platform bracket with a locating pin. SSHS12 5.2 1150 Frame Locating Pin Used to secure the Guardrail Posts to the Platform Bracket. FLP 0.55 430 430 MK2 Acrowall Transport Hook The Transport Hook is used for the crane handling of assembled Acrowall panels and the Extra Large panel. Transport Hooks must be used in pairs. Each hook has a maximum load capacity of 5kN (500 kg) enabling assemblies with a form face area of up to 30m² to be handled in one operation. See page 23 for details. Transport Hooks must only be connected to the side bars at a panel joint. The MK2 Transport Hook utilizes a positive and fast-locking screw. It has the same rated capacity as the original. AWTH 8.2 6 300 200 Ø21 holes Ø18 holes Acrowall 2.7m Panel Raker Bracket The bracket fits centrally between the intermediate ribs of a 2700mm high Acrowall Panel to provide a connection for rakers. It is suitable for applications where rakers can not be effectively connected to the side ribs of a panel such as in column formwork applications. See page 22. AWP27RB 5.4

General Technical and Application Manual Product Description Code No. Mass kg (nom.) Nail holes 1200 Acrowall Adjustment Waler Used to keep panels in alignment when using timber infill panels of up to a maximum span of 300mm. Ideal for stopends. Timber shuttering is fastened via nail holes. AWAW 8.6 Nail holes 1000 Acrowall Multi-purpose Waler Used in the same manner as the Adjustment Waler. The two built-in tie sockets provide for more secure tying at corners. The round surface of the tie sockets allows the ties to be used at an angle. AWMPW 13.1 1800 Acrowall Hinged Walers The Hinged Waler is used on acute angled corners to give support to the corner when tying is not possible. See page 17 for details. AWHW 39.0 (complete) Acrowall Tie Rod Bracket Used together with the Waler Connector, HT Thru Tie Wing Nut & Plate Washer. It connects the Hinged Waler to the Acrowall panel shutter in applications where there are oblique-angled corners. Being wedge shaped it is able to transfer horizontal forces to the shutter. AWTRB 4.0 43 Ø18 Acrowall Raker Foot Bracket for 36, 38, 40 and 42mm Dia Stem Used to fix the raker to the ground. It is secured to the raker with M16x100 bolts and nuts and to the ground with Ø20mm anchors. AWRFB40 2.5 Ø16 pin Acrowall Adjusting Strut Clamp Clamps onto Acrowall panel joints to provides a fixing point for rakers. AWASC 2.5 7

Acrowall-60 Formwork System Product Description Code No. Mass kg (nom.) Max 1735 Min 1420 Acrowall Adjustable Plumbing Brace The Plumbing Brace has the capability of adjusting to suit either 2700 or 1500 high panels. It is a plumbing component only and must not be used for support of single sided formwork during pouring. See page 22 for application details of Plumbing Braces. AWAPB 21.0 Max 960 - Min 670 Acrowall Adjustable Plumbing Brace Lower Body Can be used separately as a raker for small shutters. AWAPB-LB 6.1 Ø18 pin 40 Acrowall Prop Connector End An adapter for Acrow Props permitting it to be connected to the Raker Foot Bracket or Adjusting Strut Clamp/Prop Connector Clamp. AWPCE 4.0 103 Acrowall Prop Connector Assembly The Prop Connector Assembly comprises a Prop Connector End and a Prop Connector Clamp. The unit is used in conjunction with a double nutted Acrow Prop, a Prop Pivot End Adaptor and an Acrowall Racker Foot Bracket to provide a plumbing brace for double panel height assemblies. See page 22 for details. AWPCA 7.0 8 Acrowall Prop Connector Clamp Has a similar purpose to the Adjusting Strut Clamp and locks around the intermediate rib of an Acrowall Panel to make a stronger connection. AWPCC 3.3

General Technical and Application Manual Product Description Code No. Mass kg (nom.) 188 Acrowall Centring Tension Bolt The centring tensioning bolt is used to join panels together when an aligning clamp is not employed such as joining hinged corner panels to standard panels. It can also be used to connect panels to walers at the end of the wall when connecting stop ends. AWCTB 0.9 Acrowall Centring Plate Washer Has a profile that fits the recess of the Acrowall Panel side & end profile. It can be used with the Centring Tension Bolt and HT Thru Tie Wing Nut. AWCPW 0.5 Acrowall Centring Nut It has a base which matches the recess of the panel profile assisting to align the adjacent panels. The Acrowall Centring Nut can be used as an alternative to the HT Thru Tie Plate Washer and Wing Nut. AWCN 0.8 220 130 AZ Tie Nut 230 Due to its large size it is able to support up to 150mm wide makeup areas while being able to react superimposed loads back to the Acrowall Panel profiles. It incorporates a ball-type nut for inclinations up to 10. AWTN230 2.4 20 80 Acrowall MP Bolt Acrowall MP Nut The MP Bolt and MP Nut assembly is used to connect MP Panels when forming columns. For a complete joint, the HT Thru Tie Wing Nut and Plate Washer must be used. AWMPB AWMPN 0.6 0.5 295 9 300/500 Acrowall Waler Connector The Waler Connector is used to connect an Adjustment Waler, Multi-purpose Waler or Hinged Waler to the Acrowall panel ribs. AWWC03 AWWC05 0.8 1.1

Acrowall-60 Formwork System Product Description Code No. Mass kg (nom.) Acrowall Offset Clamp Able to align adjoining Acrowall Panels which are at different levels to each other. See page 21. AWOC 6.0 350 550 160 Acrowall Edge Tie Bracket The Edge Tie Bracket is attached to the top of the panel to allow a tie to be used at the top of the wall clear of the concrete. Maximum permitted load = 10kN. AWETB 2.4 Acrowall Punched Steel Tape (Sale Only) The ST Tightener and the Punched Steel Tape are used at the base of low height panel arrangements for foundation walls in place of the bottom tie. See page 19 for details. AWPST 17.2 Acrowall ST Tightener Used with the Acrowall Punched Steel Tape. AWSTT 3.6 10 Acrowall Panel Plug (Orange) Plugs open tie holes. AWTTC 0.1

General Technical and Application Manual Element Connection Acrowall panels are connected using the Aligning Clamp. The aligning clamp provides a tension resistant, tight joint between panels as well as holding the panel in rigid Acrowall Aligning Clamp on vertical panel joint alignment. It can be used on both vertical panel joints and on horizontal panel joints on height extended panel arrangements. When joining a 1500 high panel to a 2700 high panel Acrowall Aligning Clamp on a horizontal panel joint 1500 2700 horizontally adjacent to each other, as shown on the left, the ribs on the two panels are not exactly in line, however the first and third ribs on the 1500 panel are close enough to allow an aligning clamp to be used. Note: In multiple height assemblies additional clamps may be required to stiffen joints between panels prior to crane handling of the formwork assembly. All Acrowall clamps can be tightened, not by striking the locking screw, but by inserting a podger bar into the hole in the screw head and tightening the screw in a spanner action. This method is labour saving, prevents damage to the screw and is quiet. 2700 In height extended walls, using the adjustable aligning clamp which is longer than the aligning clamp enables the panels to be joined together along the rib of the horizontal panel with the clamp picking up across two ribs of the vertical panel thus providing true vertical alignment. Because of its greater length, the Acrowall Adjustable Aligning Clamp achieves perfect alignment in this application as it braces against the panel ribs. Horizontal panels Acrowall Adjustable Aligning Clamp 300-900 1500 Acrowall Aligning Clamp Acrowall Adjustable Aligning Clamp 11

Acrowall-60 Formwork System Formwork height 0.3m to 0.9m Horizontal Acrowall panels connected with Adjustable Aligning Clamps, tied at the top with edge tie brackets and at the bottom with ST Tightener and Punched Steel Tape. Formwork height 1.8m to 2.4m Horizontal height-extension panels connected to 1500 vertical panels. Adjustable Aligning Clamps Edge Tie Bracket 300-900 35 ST Tightener and Punched Steel Tape Formwork height 1.5m 300-900 1165 1500 1800-2400 Vertical 1500 Acrowall panels connected with Aligning Clamps. Aligning Clamp 300 1165 300 1500 Note: For single panel height form arrangements, the maximum concrete pressure the assembly will support is 60 kpa. For height extended form arrangements ie: more than one panel in height, the maximum pressure reduces to 55 kpa Depending on the pressure, it may be possible to use Acrowall Edge Tie Brackets instead of ties 35mm from the top of the form. 300-900 Formwork height 0.6m to 1.8m Two rows of panels laid horizontally. Aligning Clamps are used to join panels at the horizontal joint while Adjustable Aligning Clamps are used at the vertical joints. ST Tighteners & Punched Steel Tape must be used to support concrete pressure at the base. Formwork height 2.4m Acrowall Extra Large Panels may be laid horizontally. Additional 2700 high panels may be used to achieve the desired length. Adjustable Aligning Clamps 12 300-900 300-900 600-1800 1520 2700 1500-2700 540 2700 300-900 2400 540 1320 ST Tightener and Punched Steel Tape

General Technical and Application Manual Formwork height 2.7m 2700 high panels may be used to achieve this height. 2400 300-900 Formwork height 3.0m to 3.6m Vertical 2700 high panels with horizontal height-extended panels. Adjustable Aligning Clamps Formwork height 4.2m Vertical 2700 high and 1500 high panels. 0 1320 540 Acrowall Aligning Clamps 1520 2700 Additional Acrowall Adjustable Aligning Clamps would be required at panel edge when crane handled. 35 1520 2700 300-900 3000-3600 300 1165 35 1520 2700 1500 4200 13 4800 2400 2400 540 540 1320 540 1320 540 Acrowall Aligning Clamps 2700 300-900 Formwork height 4.8m Two Extra Large panels placed horizontally one on top of the other. Width is adjusted by using vertical 2700 panels at ends. 1520 1520 2700 2700 Acrowall Aligning Clamps 300-900 1520 1520 2700 2700 Formwork height 5.4m Horizontal height-two Vertical 2700 panels.

Acrowall-60 Formwork System Square Corners The internal corner panel has built-in stiffener plates which when locked hold the panels rigidly to a right angle. When the stiffener plates are unlocked the panel angle can decrease by 2 allowing the form to move away from the concrete for easy stripping. Outer Corner Clamp Varying panel widths Outer corner clamp Timber makeup Timber makeup Corner stiffener plate Timber makeup may need to be used for certain wall thicknesses. Outer corner clamps are able to adequately support the corner joints even if timber makeup is used. The external corner is made up using a combination of panels so that the panel joints line up with the internal corner panel. In this way the tying system can be used adjacent to the corner panel for full strength. 2 o 100 overlap 40-60 Adjustment range of outer Corner Clamps Corner stiffener plate latched Corner stiffener plate unlatched Inner Corner Inner Corner Outer Corner Outer Corner 200 600mm Panel 14 Internal Corner Panel 300 x 300 50mm timber makeup 550mm Panel 250 250 Aligning Clamp 750mm Panel Adjustable Aligning Clamp

General Technical and Application Manual 15 Required number of outer Corner Clamps and adjacent Aligning Clamps/Adjustable Aligning Clamps for outer corners Wall Thickness (mm) 150 200 250 300 350 400 450 500 550 Form Height 2700 *900 *750* *750 # 900 900 *750 750 700 750 650 700 600 650 550 600 500 550 450 Outer Corner Clamps 3 3 3 3 4 4 5 5 5 3 x 2 3 x 2 3 x 2 3 x 2 4 x 2 4 x 2 4 4 5 Aligning Clamps Adjustable Aligning Clamps 4 4 5 Form Height 5400 *900 *750* *750 # 900 900 *750 750 700 750 650 700 600 650 550 600 500 550 450 Outer Corner Clamps 7 7 7 7 9 9 11 11 11 (7 x 2) + 4 (7 x 2) + 4 (7 x 2) + 4 (7 x 2) + 4 (8 x 2) + 4 (8 x 2) + 4 8 + 4 8 + 4 11 + 4 Aligning Clamps Adjustable Aligning Clamps 8 8 11 Note: * Indicates 50mm wide timber makeup. # indicates 100mm wide timber makeup.

Acrowall-60 Formwork System Obtuse Corners To cater for non right angled corners hinged corner panels are available in two widths 150 x 150 and 300 x 300. The 300 wide hinged panel can only be used on the internal face. Due to the varying growth in wall length for obtuse corners it is not always possible for panel joints to line up. MP panels are ideal for such applications as it gives greater flexibility in placement of ties. Hinged Corner Panel 150 x 150 MP Panel Max 150 o Min 60 o Hinged Corner Panel 300 x 300 The above arrangement shows a combination of 300 x 300 hinged corner panel on the internal corner with 150 x 150 panel used on the external corner. Note: 150 x 150 hinged corner panels should always be joined to adjacent panels using the Centring Tension Bolt with either the Centring Nut or Centring Plate Washer and HT Thru Tie Wing Nut. Timber make-up Centring Tension Bolt Hinged Corner Panel 150 x 150 Hinged Corner Panel 150 x 150 MP Panel Timber make-up MP Panel Hinged Corner Panel 150 x 150 Max 175 o Min 90 o 16 Hinged Corner Panel 300 x 300 The above arrangement shows 150 x 150 hinged corner panels used on the internal and external corner. This combination can only be used on angles greater than 90.

General Technical and Application Manual Acute Corners The Hinged waler solves the problem of tying when Acrowall is used to form acute-angled corners (< 90 ). Hinged Corner Panel 300 x 300 The Hinged Waler is attached to the end panel by the Waler Connector 500mm in conjunction with a Tie Rod Bracket. Tie Rod Bracket Timber Makeup Waler Connector 500mm Min 60 o Hinged Waler Hinged Waler Waler Connector 500mm Tie Rod Bracket Hinged Corner Panel 150 x 150 Timber makeup Centring Tension Bolt and Nut 17 Note: 150 x 150 hinged corner panels cannot be used as the internal corner on any acute angled wall. The panel will not close beyond 90. Possible effective adjustment ranges of hinged corner panels Hinged Corner 300 x 300 Min 60 o Hinged Corner 150 x 150 Max 300 o Min 90 o Centring Tension Bolt and Nut Aligning Clamp Note: Because the 300 x 300 hinged corner panel has the same side bar as a standard panel it can be joined to adjacent panels with the Centring Tension Bolt and Nut or by using the Aligning Clamp. The 150 x 150 corner panels, however have a flat side bar so the alignment clamp cannot be used to joint them to a standard panel. Note: When using the 300 x 300 hinged corner panel on an acute angled internal form face, if the angle is less than 70 then the tie rods will clash. In this situation MP panels would have to be used on one side of the hinged corner panel to enable the ties to be offset from the joint to allow clearance. Max 150 o

Acrowall-60 Formwork System T-Junctions Wall T-junctions can be easily accommodated using standard panels together with timber and plywood makeups where necessary. Stopends The holes in the edge profile of the panels provides a means to fasten support for stopends. Centring Tension Bolts and Nuts can be used through the holes to secure Adjustment Walers. Timber and plywood stopends Adjustment Waler Centring Tension Bolt Nut and Washer Length Adjustment Max 150 When tying through the timber makeup, make sure that the washer is sufficiently supported by the side bars of the adjacent panel. AZ Tie Nut 230 For wall thicknesses greater than 300mm at least 3 walers would be required for a wall height of 2.7m. Adjustment Waler >300 Adjustable Clamp Plywood and timber size to suit 18 Timber and plywood site constructed makeup panels can be nailed in place through the holes in the waler. Maximum width of makeup 300mm. Centring Tension Bolt Adjustment Waler Waler Connection 300 Tie

General Technical and Application Manual Tying Acrowall assemblies are tied using the thru tie system through the tie hole positions in the panels. Before insertion of the tie rod the plastic plug must be removed, all holes not used by ties must be plugged to prevent grout loss. If timber makeups are used for adjustment at a panel joint, tying is more effective if made through the timber makeup. Plastic spacer tube and plastic cones must be used with the thru tie system. Timber makeup Adjustable Aligning Clamp Plug Note: Cones and Spacer Tube are not in assembled position for clarity. In foundation walls it is often difficult to tie the formwork. When using single panels horizontally a simple method is to use the Acrowall ST Tightener and Punched Steel Tape at the base and Acrowall Edge Tie Brackets at the top of the form. Acrowall panel rib Stirrup bolt HT Thru Tie Rod Wing Nut Plate Washer Acrowall Edge Tie Bracket Threaded bolt Finger Holes at 50mm intervals in steel tape 19 Acrowall ST Tighteners are inserted into the ribs of the horizontal panels. The finger of the Acrowall ST Tightener is inserted into one of the holes in the steel tape and the formwork is adjusted using the threaded bolt which takes up the slack in the tape so the tape can resist the tensile force resulting from the concrete pressure. Punched Steel Tape Note: Maximum permissible load for either the Steel Tape system or the Edge Tie Bracket is 10kN. For 900 high foundation walls this means a maximum horizontal distance between ties of 1.5m.

Acrowall-60 Formwork System Column Formwork with MP Panels The MP Panel (multi-purpose panel) with its continuous rows of tie holes is ideally suited for the construction of smaller/odd size columns. Four MP panels assembled in the configuration depicted below can create a variable form for square or rectangular columns with adjustment in 50mm increments from 150mm to 550mm. Columns using Standard Panels Column forms made of standard Acrowall panels can be simply and quickly assembled for a wide range of dimensions using the outer corner clamp. By arranging the panels in pairs or offsetting them, or by using a timber packer at the panel overlap, the form can be built for column cross sections ranging in size from 200mm to 850mm maximum. Min 150 - Max 550 Panels in pairs 80 11 @ 50mm spacings 32 Tie holes 36 Panels offset Hole for MP Panel Section through MP Panel Outer Corner Clamp HT Thru Tie Wing Nut and Plate Washer Timber packer MP Bolt Acrowall Panels MP Nut Outer Corner Clamp 50 Min 50mm overlap Adjustable Aligning Clamp Note: On height-extended column formwork with panels of different size, the smaller panel should always be used at the bottom. The Adjustable Aligning Clamp is used as the connector. The number of corner clamps required depends on the form height and the width of the panels being used. Number of corner clamps Form height Panel < 600 Panel > 600 1500 3 4 3 4 2700 4 4 5 4 20 Panels offset Panels in pairs

General Technical and Application Manual Brackets The Acrowall Platform Bracket hooks into the holes of the panel ribs to provide a 730 mm wide working platform suitable for 3 timber planks in width. The bracket features a tubular socket at its end into which a guardrail post is attached using a Ø16 connecting pin or Frame Locating Pin. The timber planks are bolted to the top plate of the bracket to provide the platform. M20 x 50 Bolt and Nut 765 Guardrail Post 1100 Guardrails Timber planks R clip fitting to securing pins Platform Bracket Frame Locating Pin Platform Bracket Planks and guardrails omitted for clarity When fitted to horizontally placed panels the bracket is secured to the rib using an M20 bolt and nut. Note: Maximum distance between platform brackets must not exceed 1.8m. Maximum platform load must not exceed 650 kgs uniformly distributed along the length of the platform brackets. Timber planks must be a minimum of 230 x 39 LVL complying with AS1577. Acrowall Offset Clamp Planks must be bolted to platform bracket using M10 cup head bolts and nuts (bolt length 60mm). A tubular guardrail and a midrail must be attached to the guardrail post using right angled double couplers. A timber kick board shall also be provided along the outer edge of the platform fixed to the guardrail post by Toe Board Clamps. 21 Stepped Forms The Acrowall Offset Clamp can be used to join panels in stepped formwork applications. It attaches to the ribs of adjoining panels both joining and aligning them. Although it can be used as a substitute for a normal Aligning Clamp since its aligning member bears directly on the horizontal ribs it is intended to be used for applications where the height difference of the adjoining panel is between 60-270mm. The vertical alignment mem must bear against two horiz ribs of the adjoining panel.

Acrowall-60 Formwork System Struts Acrowall Prop Connector Assembly Acrow Prop with double nuts The adjustment range of the Acrowall plumbing brace allows it to be used on either the 2700 panel or the 1500 panel. When two panel high arrangements are used, the top panel is plumbed by using a combination of an Acrowall Prop Connector Assembly used in conjunction with a double nutted Acrow prop, an Acrowall Prop Connector End and an Acrowall Raker Foot Bracket. Acrowall Panels Acrowall Plumbing Brace assembly Acrowall Prop Connector End Acrowall Raker Foot Bracket Prop Connector Clamp Maximum spacing between Plumbing Brace assemblies must not exceed 2.25m Adjustable Plumbing Brace Lower Body For small shutters comprising 1200 high panels, an assembly consisting of an Acrowall Adjustable Plumbing Brace Lower Body, Acrowall Prop Connector Clamp and Raker Foot Bracket can be used. Acrowall Raker Foot Bracket 2.7m Panel Raker Bracket The 2.7m Panel Raker Bracket is suitable for applications where rakers can not be effectively connected to the side ribs such as is in column formwork. It connects to the middle of a 2700 Acrowall Panel & can accommodate any type of raker up to 50mm diameter or width. M16x100 bolts & nuts (4 off) must be used to connect the raker. Raker loads must not exceed 6kN. 22 Acrow Tilt-Up Brace 2300-4000mm Tilt-Up Brace Foot Bracket Horizontal ribs 2.7m Panel Raker Bracket 2700 Acrowall Panel Due to its size, the 2.7m Panel Raker Bracket can only be connected to a 2700 Acrowall Panel at 3 possible locations.

General Technical and Application Manual Crane Handling The Transport Hook must always be connected to a panel joint. With the Fastening Bolt withdrawn, the hook is guided over the panel edge profiles and aligned with the top hole. When the Fastening Bolt is fully inserted, the Transport Hook is ready for use. On an Extra Large Panel 2700x2400, the connection point for the Transport Hook for individual panel handling is in the corner at the rail profiles. Units for crane handling must not comprise more than 3 Extra Large panels. Caution: The Fastening Bolt must be fully inserted before use 2400 2700 Important notes on using Acrowall Transport Hooks When shifting large area elements the transport hooks must be used. Transport hooks must be used in pairs. 2700 Connection points for horizontal Extra Large panels Angle of spread of crane ropes must be 60o 2400 Connection points for vertical Extra Large panels When standard panels are being used the transport hook must always be connected to a panel joint. The transport hook must always be positioned in the upper hole of the edge member of the panel. The fastening pin must always be fully engaged before lifting. The angle of spread between crane ropes must not exceed 60. 23 When using Acrowall extra large panels only 3 panels may be lifted at one time. Maximum load for a pair of transport hooks is 1000 kg ie: 500 kg each. Maximum form area handled containing standard panels only is 30m². Maximum form area handled containing extra large panels (limit 3) and standard panels is 25m².

Updated October 2011 Formwork Scaffolding Industrial & Mining Scaffolding Contact Phone: 1300 138 362 or contact your business development manager. www.acrow.com.au