VariSTAR Type AZL heavy-duty distribution-class MOV arrester

Similar documents
Surge Arresters. VariSTAR Type AZS Normal Duty Distribution Class MOV Arrester

VariSTAR Type AZU heavy-duty distribution-class under-oil MOV surge arrester

35 kv Class M.O.V.E. DirectConnect elbow arrester

Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

POSI-BREAK Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

COOPER POWER. UltraSIL Polymer-Housed VariSTAR Type U2Surge Arrester for Systems through 275 kv IEC 10-kA; Line Discharge Class 2 SERIES

Effective February 2017 Supersedes January 2012 (CP1122)

UltraSIL Polymer-Housed VariSTAR Normal-Duty, Heavy-Duty and Riser Pole Distribution-Class Arresters

UltraSIL Polymer-Housed Evolution Distribution Class Surge Arrester Certified Test Report

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

Eaton s Cooper Power Series DEADFRONT ARRESTERS

Type DMX-N Surge Arresters Maximum System Voltage 2 to 36 kv

Tab 8 Surge Arresters

Two- and three-phase MagneX interrupter

ANSI DESIGN TEST REPORT Report No. EU1295-H-00 Type PVN Station Class Surge Arrester

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

CLU Arrester. Certified Test Report. IEEE Standard C

Analysis of Major Changes to Arrester Standards IEC STEVE BREWER

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

Energy Division. Bowthorpe LV/MV Surge Arresters

3EK8 distribution class surge arresters. Catalogue HP-AR Version siemens.com/arresters

AMENDMENT NO. 1 SEPTEMBER IS (Part 1) : 2001/IEC (1991) SURGE ARRESTORS

SURGE ARRESTERS AND TESTING. Keith Hill Doble Engineering Company

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

Insulation Co-ordination For HVDC Station

Substation Design Volume VII

LIGHTNING ARRESTOR. September 2017 WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

Comparison of recloser and breaker standards

Our experience. Our products

Figure 1. Two- and Three-phase MagneX Interrupter.

EE 1402 HIGH VOLTAGE ENGINEERING

TECHNICAL SPECIFICATION

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

IEC Type Test Report Report No. EU1517-H-00.1 H4 Series Porcelain-housed Arrester 20,000 A Line Discharge Class 4

Distribution Transformers

How to maximize reliability using an alternative distribution system for critical loads

Power-Sure 700. Technical Data TD158001EN. Contents

A Case Study on Selection and Application of Lightning Arrester and Designing its Suitable Grounding Grid

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

International Journal of Advance Engineering and Research Development. Analysis of Surge Arrester using FEM

Evaluating the Response of Surge Arresters

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

Modeling insulation in high-voltage substations

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

Comparison of CAN/CSA C88.1, IEEE C /01 & IEC 60137

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

CONTINUING EDUC ATION

INTERNATIONAL STANDARD

Grounding for Power Quality

Substation transformers

Network Standard NETWORK. Document No Amendment No Approved By Approval Date Review Date NW000-S0142 : : : : : Head of AEP&S 08/06/ /06/2017

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Under-Oil ARRESTERS Page 1 July 2016

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

Howard Smart Transformer Specification Guide

Selection of MO surge arresters Overvoltage protection

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

II Design Criteria for Electrical Facilities Connected to the PJM 765 kv, 500 kv, 345 kv, 230 kv, 138 kv, 115 kv, & 69 kv Transmission Systems

MODIFICATION OF THE ARRESTER ARRANGEMENT WHEN CONVERTING THE METHOD OF NEUTRAL TREATMENT

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

TABLE OF CONTENT

Great Northern Transmission Line: Behind the (Electrical) Design

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)

2 Grounding of power supply system neutral

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

MINISTRY OF ELECTRICITY

Electric Stresses on Surge Arrester Insulation under Standard and

Effect of Surge Arrester on Overhead Transmission Lines as Shield against Over Voltage

OVERVOLTAGE PROTECTION. Dimensioning, testing and application of metal oxide surge arresters in low-voltage power distribution systems

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

Arrester Disconnector

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

(participation = half letter grade, 5%)

Utility System Lightning Protection

Analysis of lightning performance of 132KV transmission line by application of surge arresters

Analysis of MOV Surge Arrester Models by using Alternative Transient Program ATP/EMTP

Specifications. S&C Circuit-Switcher Mark V Outdoor Transmission (34.5 kv through 345 kv) Conditions of Sale SPECIAL TO THIS PRODUCT:

Tab 2 Voltage Stresses Switching Transients

Our Brands. Where we are?

Simulation and Analysis of Lightning on 345-kV Arrester Platform Ground-Leading Line Models

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

VI 3 - i TABLE OF CONTENTS

SPTS 1 - Ratings and General Requirements for Plant, Equipment and Apparatus for The ScottishPower System and Connection Points to it.

Article 250 Grounding & Bonding

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

Voltage Sag Mitigation by Neutral Grounding Resistance Application in Distribution System of Provincial Electricity Authority

CEYLON ELECTRICITY BOARD SRI LANKA. Procurement of Plant

Are snubbers required with Eaton s Cooper Power series liquid-filled hardened transformers?

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

Liquid-Filled Transformers

Construction zglass passivated collar zaluminum termination for pressure contact

Transformers connected via a cable Overvoltage protection

Transcription:

Surge s Catalog Data CA235006EN Supersedes TD235007EN September 2014 COOPER POWER SERIES VariSTAR Type AZL heavy-duty distribution-class MOV arrester General Eaton incorporates the latest in metal oxide varistor (MOV) technology in a porcelain design with its Cooper Power series VariSTAR Type AZL heavy-duty distribution-class MOV arrester in ratings of 3 through 36 kv. With this combination of technologies, Eaton can offer reliable and cost effective overhead protection of distribution systems. Construction The VariSTAR Type AZL arrester consists of highly nonlinear metal oxide varistors enclosed in a porcelain housing. The highly nonlinear nature of the MOV disks results in conduction of leakage current of milliamperes at nominal line-to-ground operating voltage. This small amount of leakage current (which is primarily capacitive current with a small component of resistive current) can be tolerated on a continuous basis. The VariSTAR Type AZL design is available with or without an isolator and can be supplied with a variety of mounting brackets to satisfy a wide range of applications. Operation The operation of the VariSTAR Type AZL is typical of gapless metal oxide arresters. During steady state conditions, nominal line-to-ground voltage is applied continuously across the arrester s terminals. When overvoltages occur, the VariSTAR Type AZL arrester limits the overvoltage to required protective levels by conducting the surge current. Upon passage of the overvoltage condition, the arrester returns to a highly nonlinear steady state, conducting minimal leakage current. The superior protective characteristics of the VariSTAR Type AZL arrester provide excellent protection for distribution transformers with lower impulse withstand capabilities. Its superior reliability makes it an ideal choice for areas with high isokeraunic levels. CA235006EN-1

Catalog Data CA235006EN VariSTAR Type AZL heavy-duty distribution-class MOV arrester Features and detailed description INSULATING TERMINAL CAP Polymer cap provides superior wildlife protection. TOP ELECTRODE Ensures low resistive contact to MOV disk column. MOV DISKS Highly nonlinear metal oxide varistors provide exceptional surge protection. COPPER STRAP Provides a low resistance shunt for surge current discharge. ISOLATOR GROUND LEAD DISCONNECTOR Provides positive isolation and visual identification if arrester becomes damaged internally. Figure 1. Cutaway illustration of VariSTAR AZL arrester. HIGH STRENGTH WET PROCESS GLAZED PORCELAIN Withstands thermal and mechanical shocks; excellent washing characteristics; provides high creepage distance above and below the hanger bracket. ALUMINUM SPACER Provides additional length for extended creepage porcelain. HEAVY STEEL COIL SPRING Maintains high pressure on disks for effective contact surfaces; protects from mechanical shock. IDENTIFICATION INFORMATION Convenient reference for arrester type, MCOV, voltage rating and year and quarter of manufacture. SOLDERLESS CONNECTORS Accommodates No. 10 solid through No. 2/0 stranded line and ground leads. Production tests A complete production test program ensures a quality product. Each VariSTAR metal oxide varistor receives a series of electrical tests. Quality is further ensured by a series of destructive tests performed on every batch of varistors. Listed are the tests that are performed on the varistors: 100% Physical Inspection 100% Discharge Voltage Test 100% V1mA/cm 2 100% Leakage Current at 80% of V1mA/cm 2 Voltage Batch High-current, Short-duration Test Batch Thermal Stability Test Batch Disk Aging Test Each VariSTAR Type AZL arrester must pass the following production tests: 100% Physical Inspection 100% Vacuum over Fluid Seal Test 100% Leakage Current Test 100% RIV Test Standards The VariSTAR Type AZL arrester complies with the latest revision of IEEE Std C62.11-1987 standard IEEE Standard for Metal Oxide Surge s for AC Power Circuits. General application recommendations The rating of an arrester is the power frequency line-to-ground voltage at which the arrester is designed to pass an operating duty-cycle test. Table 1 provides a general application guide for the selection of the proper arrester rating for a given system voltage and system grounding configuration. Eaton's application engineers are available to make recommendations. The following information is normally required: 1. System maximum operating voltage. 2. System grounding conditions. A. For four-wire circuits, grounding conditions depend upon whether the system is multi-grounded, whether it has a neutral impedance and whether common primary and secondary neutrals are used. B. For three-wire circuits, grounding conditions depend upon whether the system is solidly grounded at the source, grounded through neutral impedance at the source transformers or ungrounded. CA235006EN-2 www.eaton.com/cooperpowerseries

VariSTAR Type AZL heavy-duty distribution-class MOV arrester Catalog Data CA235006EN Table 1. Commonly Applied Voltage Ratings of the VariSTAR AZL System Voltage Nominal Maximum Recommended Rating Four-Wire Wye Multi-Grounded Neutral Three-Wire Wye Solidly Grounded Neutral 2.4 2.54 3 4.16Y/2.4 4.4Y/2.54 3 6 6 4.16 4.4 6 4.8 5.08 6 6.9 7.26 9 8.32Y/4.8 8.8Y/5.08 6 9 12.0Y/6.93 12.7Y/7.33 9 12 12.47Y/7.2 13.2Y/7.62 9 15 13.2Y/7.62 13.97Y/8.07 10 15 13.8Y/7.97 14.52Y/8.38 10 15 13.8 14.52 18 20.78Y/12.0 22Y/12.7 15 21 22.86Y/13.2 24.2Y/13.87 18 24 23 24.34 30 24.94Y/14.4 26.4Y/15.24 18 27 27.6Y/15.93 29.3Y/16.89 21 30 34.5Y/19.92 36.5Y/21.08 27 36 46Y/26.6 48.3Y/28 36 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1 Per Unit MCOV Per Unit Rating Delta and Ungrounded Wye Where unusual conditions exist (high ground resistance, high capacitive load, arc-welding equipment, etc.) the following supplementary information is necessary: 1. The unusual condition. 2. Type of construction, phase spacing, length of line, conductor size. 3. BIL of equipment and line insulation. 4. Phase-sequence components of impedances on the load side of the distribution substation. The impedance of the transformer and the impedance and grounding of supply to the substation all affect the voltage during faults. The Temporary Overvoltage (TOV) capability of the VariSTAR AZL arrester is shown in Figure 2. Performance test characteristics The VariSTAR AZL arrester consistently withstands the following design tests as described by IEEE Std C62.11-1987 standard: Duty cycle 20 current surges of 10 ka crest 8/20 µs waveshape followed by 2 current surges of 40 ka crest 8/20 µs waveshape. High-current, short-duration discharge: 2 current surges of 100 ka crest 4/10 µs waveshape. Low-current, long-duration discharge: 20 current surges of 250 A crest 2000 µs rectangle wave duration. Following each of these tests, the arresters remain thermally stable as verified by: Continually decreasing power values during a thirty minute power monitoring period. No evidence of physical or electrical deterioration. The 10 ka (8/20 µs) discharge voltages measured after each test changed by less than 10% from the initial values. 0.9 0.1 1 10 100 1000 10000 Time Duration in Seconds Figure 2. Temporary overvoltage curve. No prior duty 60 C ambient. www.eaton.com/cooperpowerseries CA235006EN-3

Catalog Data CA235006EN VariSTAR Type AZL heavy-duty distribution-class MOV arrester Protective characteristics The protective characteristics of the VariSTAR AZL arresters are shown in Table 2. Table 2. Protective Characteristics Rating MCOV Front-of-wave Protective Level* (kv crest) Maximum Discharge Voltage (kv crest) 8/20 µs Current Wave 1.5 ka 3 ka 5 ka 10 ka 20 ka 40 ka 3 2.55 10.7 8.2 8.7 9.2 10.0 11.3 13.6 6 5.10 21.4 16.4 17.4 18.4 20.0 22.5 27.1 9 7.65 32.1 24.5 26.1 27.5 30.0 33.8 40.7 10 8.40 35.3 27.0 28.7 30.3 33.0 37.2 44.7 12 10.20 42.8 32.7 34.7 36.7 40.0 45.0 54.2 15 12.70 53.5 40.9 43.4 45.9 40.0 56.3 67.8 18 15.30 64.2 49.1 52.1 55.1 60.0 67.6 81.4 21 17.00 74.9 57.3 60.8 64.3 70.0 78.8 94.9 24 19.50 84.3 64.4 68.4 72.3 78.8 88.7 106.8 27 22.00 95.2 72.8 77.3 81.7 89.0 100.2 120.7 30 24.40 105.9 81.0 86.0 90.9 99.0 111.5 134.2 36 29.00 124.8 95.4 101.3 107.0 116.6 131.3 158.1 * Based on 10 ka current impulse that results in a discharge voltage cresting in 0.5µs. Insulation characteristics The insulation characteristics of the VariSTAR AZL arresters are shown in Table 3. Table 3. Insulation Characteristics Rating (kv rms) Creepage Strike Insulation Withstand Voltages (in.) (cm) (in.) (cm) 1.2/50 μs Impulse (kv crest) 1 min. Dry 3 2.8 7.1 2.0 5.1 45 15 13 6 6.6 16.8 4.5 11.4 60 21 20 9 10.4 26.4 7.0 17.8 75 27 24 10 10.4 26.4 7.0 17.8 75 27 24 12 13.2 33.5 8.9 22.6 95 35 30 15 13.2 33.5 8.9 22.6 95 35 30 18 17.9 45.5 12.0 30.5 125 42 36 21 17.9 45.5 12.0 30.5 125 42 36 24 21.7 55.1 14.4 36.6 150 70 60 27 21.7 55.1 14.4 36.6 150 70 60 30* 26.4 67.1 17.5 44.5 200 95 80 36* 26.4 67.1 17.5 44.5 200 95 80 * Not applicable to AZL19C Series. 10 sec. Wet CA235006EN-4 www.eaton.com/cooperpowerseries

VariSTAR Type AZL heavy-duty distribution-class MOV arrester Catalog Data CA235006EN Dimensions and clearances The dimensions and clearances of the VariSTAR AZL arresters are shown in Figures 3, 4 and 5. Rating Dimensions Figure 3. Dimensions for AZL1A, AZL1B, and AZL19B series. Minimum Recommended Clearances* A B Phase-to-Ground Phase-to-Phase (in.) (cm) (in.) (cm) (in.) (cm) (in.) (cm) 3 9.19 23.3 5.20 13.2 3.4 8.6 5.2 13.2 6 11.67 29.6 5.20 13.2 4.4 11.2 6.5 16.5 9 14.77 37.5 5.82 14.8 5.6 14.2 8.0 20.3 10 14.77 37.5 5.82 14.8 5.6 14.2 8.0 20.3 12 17.25 43.8 6.44 16.4 6.4 16.3 8.7 22.1 15 17.25 43.8 6.44 16.4 7.1 18.0 9.7 24.6 18 20.97 53.3 7.06 17.9 9.6 24.4 12.2 31.0 21 20.97 53.3 7.06 17.9 9.6 24.4 12.2 31.0 24 24.07 61.1 7.68 19.5 11.1 28.2 14.2 36.1 27 24.07 61.1 7.68 19.5 11.1 28.2 14.2 36.1 30 27.79 70.6 8.30 21.1 11.1 28.2 14.2 36.1 36 27.79 70.6 8.30 21.1 13.1 33.3 17.2 43.7 2.68 TO 4.00 4.00 TO 5.00 1.69 3.06 DIA. 2.56 3.87 0.20 2.34 B A * All clearances are measured from centerline of arrester per IEEE Std C62.11-1987 standard. Rating Dimensions Minimum Recommended Clearances* A B C D E Phase-to-Ground Phase-to- Phase (in.) (cm) (in.) (cm) (in.) (cm) (in.) (cm) (in.) (cm) (in.) (cm) (in.) (cm) 3 9.19 23.3 5.20 13.2 6.04 15.3 10.77 27.4 4.12 10.5 3.4 8.6 5.2 13.2 6 11.67 29.6 5.20 13.2 8.52 21.6 13.25 33.7 4.12 10.5 4.5 11.4 6.5 16.5 9 14.77 37.5 5.82 14.8 11.00 27.9 15.73 40.0 4.12 10.5 5.6 14.2 8.0 20.3 10 14.77 37.5 5.82 14.8 11.00 27.9 15.73 40.0 4.12 10.5 5.6 14.2 8.0 20.3 12 17.25 43.8 6.44 16.4 12.86 32.7 17.59 44.7 4.12 10.5 6.4 16.3 8.7 22.1 15 17.25 43.8 6.44 16.4 12.86 32.7 17.59 44.7 4.12 10.5 7.1 18.0 9.7 24.6 18 20.97 53.3 7.06 17.9 15.96 40.5 20.69 52.6 4.12 10.5 9.6 24.4 12.2 31.0 21 20.97 53.3 7.06 17.9 15.96 40.5 20.69 52.6 4.12 10.5 9.6 24.4 12.2 31.0 24 24.07 61.1 7.68 19.5 18.44 46.8 23.17 58.9 4.12 10.5 11.1 28.2 14.2 36.1 27 24.07 61.1 7.68 19.5 21.22 53.9 32.20 81.8 4.38 11.1 11.1 28.2 14.2 36.1 30 27.79 70.6 8.3 21.1 24.32 61.8 35.30 89.7 4.38 11.1 11.1 28.2 14.2 36.1 36 27.79 70.6 8.30 21.1 24.32 61.8 35.30 89.7 4.38 11.1 13.1 33.3 17.2 43.7 Figure 4. Dimensions for AZL31B series. Note: Note: Columns B, C, & D are calculated with the bracket located at the top of the bellyband region. Mounting Lug Spacing for 3 through 24 kv is 2.5 (6.4 cm) and for 27 through 36 kv is 9.25 (23.5 cm). *All clearances are measured from centerline of arrester per IEEE C62.11-1987 standard.. 0.20 IMPORTANT The values shown in Figures 3, 4, and 5 are the minimum clearances recommended by Eaton. These clearances may be revised to meet local or system requirements for spacing or energized equipment. However, safe operating procedures must always be followed. 2.75" REF. D C 3.06 DIA. B A TOP VIEW E SIDE VIEW www.eaton.com/cooperpowerseries CA235006EN-5

Catalog Data CA235006EN VariSTAR Type AZL heavy-duty distribution-class MOV arrester Rating Minimum Recommended Clearances* Enclosure Application Outdoor Application Dimensions Phase-to-Ground Phase-to-Phase Phase-to-Ground Phase-to-Phase A B (in.) (cm) (in.) (cm) (in.) (cm) (in.) (cm) (in.) (cm) (in.) (cm) 3 2.25 5.7 4.05 10.3 2.50 6.4 4.30 10.9 8.38 21.3 4.39 11.2 6 3.05 7.7 5.10 13.0 3.55 9.0 5.60 14.2 10.86 27.6 4.39 11.2 9 3.80 9.7 6.10 15.5 4.55 11.6 6.85 17.4 13.96 35.5 50.1 12.7 10 4.05 10.3 6.35 16.1 4.80 12.2 7.10 18.0 13.96 35.5 5.01 12.7 12 4.55 11.6 6.85 12.4 5.75 14.6 8.05 20.5 16.44 41.8 5.63 14.3 15 5.30 13.5 7.85 19.9 6.75 17.2 9.30 23.6 16.44 41.8 5.63 14.3 18 6.15 15.6 8.70 22.1 7.85 20.0 10.40 26.4 20.16 51.2 6.25 15.9 21 7.05 17.9 9.60 24.4 9.25 23.5 11.80 30.0 20.16 51.2 6.25 15.9 24 7.85 19.9 10.90 27.7 9.85 25.0 12.90 32.8 23.26 59.1 6.87 17.4 27 8.75 22.2 11.80 30.0 11.45 29.1 14.50 36.8 23.26 59.1 6.87 17.4 Figure 5. Dimensions for AZL19C series. * All clearances are measured from centerline of arrester and are based upon the protective characteristics of the arrester. 1.24 0.20 3.06 DIA. A Ordering information To order a VariSTAR AZL arrester, determine the voltage rating for the intended application using Table 1. Specify the appropriate catalog number from Table 4. Contact an Eaton representative for applications not listed. 3.87 2.34 B Table 4. Ordering Information Rating Catalog Numbers: VariSTAR Type AZL Crossarm Bracket and 19.25" Line Lead Without Crossarm Bracket Crossarm Bracket Transformer Mounting Bracket Cubicle Mounted (Without Isolator) 3 AZL1A3R AZL19B3R AZL1B3R AZL31B3R AZL19C503R 6 AZL1A6R AZL19B6R AZL1B6R AZL31B6R AZL19C506R 9 AZL1A9R AZL19B9R AZL1B9R AZL31B9R AZL19C509R 10 AZL1A10R AZL19B10R AZL1B10R AZL31B10R AZL19C510R 12 AZL1A12R AZL19B12R AZL1B12R AZL31B12R AZL19C512R 15 AZL1A15R AZL19B15R AZL1B15R AZL31B15R AZL19C515R 18 AZL1A18R AZL19B18R AZL1B18R AZL31B18R AZL19C518R 21 AZL1A21R AZL19B21R AZL1B21R AZL31B21R AZL19C521R 24 AZL1A24R AZL19B24R AZL1B24R AZL31B24R AZL19C524R 27 AZL1A27R AZL19B27R AZL1B27R AZL31B27R AZL19C527R 30 AZL1A30R AZL19B30R AZL1B30R AZL31B30R 36 AZL1A36R AZL19B36R AZL1B36R AZL31B36R CA235006EN-6 www.eaton.com/cooperpowerseries

VariSTAR Type AZL heavy-duty distribution-class MOV arrester Catalog Data CA235006EN This page is intentionally left blank. www.eaton.com/cooperpowerseries CA235006EN-7

Catalog Data CA235006EN VariSTAR Type AZL heavy-duty distribution-class MOV arrester Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Cooper Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2015 Eaton All Rights Reserved Printed in USA Publication No. CA235006EN Eaton, Cooper Power, Isolator, and VariSTAR are valuable trademarks of Eaton in the U.S. and other countries. You are not permitted to use these trademarks without the prior written consent of Eaton. IEEE Std C62.11-1987 standard is a trademark of the Institute of Electrical and Electronics Engineers, Inc., (IEEE). This publication is not endorsed or approved by the IEEE. For Eaton s Cooper Power series VariSTAR AZL surge arrester product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries. CA235006EN-8