BACnet Protocol Implementation Conformance Statement

Similar documents
BACnet Protocol Implementation Conformance Statement

Communicative heating and cooling controller, BACnet MS/TP UB200. Summary

RF-RXS-B SonNet Wireless Receiver BACnet IP

Nemo D4-L+ BACNET COMMUNICATION PROTOCOL. BACnet Protocol Implementation Conformance Statement. Date: March, 30 th 2012 Vendor Name:

IF96014 BACnet COMMUNICATION PROTOCOL. BACnet Protocol Implementation Conformance Statement

EPC3000 Programmable Controller

USB BACNET COMMUNICATION OPTION MANUAL

Electronic pressure-independent characterised control valve with energy monitoring

Electronic pressure-independent characterised control valve with energy monitoring

USB BACNET COMMUNICATION OPTION MANUAL

Sensor BACnet PICS. Contents. 1. Operating elements for addressing and parametrization 2 2. Protocol Implementation Conformance Statement - PICS 3

BAS Integration Manual

BAC-IO9 BACnet MS/TP Input / Output Modules, Wall Mounted

BACnet- MS/TP COMMUNICATION V

SRC-110 Series Zone Controllers. BACnet MS/TP. Product sheet CT2.143 SRC-110-BAC

AQUAVAR CPC. Modbus Communications (Software Version 204 and later)* INSTRUCTION MANUAL ADAQCPC R1

BACnet PTEC Controller Dual Duct 2 AVS - Constant Volume with Two Inlet Sensors and Optional Reheat, Application 6665

CALEC ST II BACnet MS/TP

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

GS1 Parameter Summary Detailed Parameter Listings...4 9

GB QUICK GUIDE FOR THE CONFIGURATION OF VARIABLE SPEED DRIVES

BACnet PTEC Controller VAV with CO2 Monitoring, Parallel Fan and AOV or Floating Point Heating, Application 6682

NX Series Inverters. HVAC Pocket Programming Guide

BACnet Integration Manual

MINI and MIX Series I/O modules

Belimo Gateway MP to BACnet MS/TP - UK24BAC

PIR Ready SE7200, SE7300 & SER7300 Series

APP /07/00 KEEP WITH USER MANUAL. Using The TIU Terminal Range With a Hitachi L100 & SJ100 Inverter.

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

vacon nx all in one application manual ac drives Phone: Fax: Web: -

Altivar 68 Telemecanique

BACnet communication module for TCX2: AEX-BAC

1. INTRODUCTION Fire Mode PID Application Parameter lists DESCRIPTION OF PARAMETERS... 8

Operating Instructions

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

SAFETY PRECAUTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

NX series Constant and variable torque Variable Speed Drives for induction motors

maxon document number:

Safety 3 Introduction 4 About this Manual 4 Assumptions 4 HP/kW Conversion 6

vacon 100 flow ac drives application manual

Cover sheet. Handling the Demo Case. SINAMICS G120 with CU250S-2 Vector. FAQ October Service & Support. Answers for industry.

Universal Controller

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

Automate. Hardware: Software: 1. Somove Lite V (or latest version available) for drive configuration optional

FCU-503 FAN COIL CONTROLLER WITH RDU-TOUCH INTERFACE

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

PumpSmart Commissioning Process

M-Max series drives. The next generation of OEM drives

160 Series C Custom Firmware

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD.

Honeywell. Application Manual. SmartVFD HVAC / SmartDrive HVAC. Variable Frequency Drives for Variable Torque Applications FW0078V

FCU-501 FAN COIL CONTROLLER WITH RDU-4 INTERFACE

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

Comp-AC. User s Manual for type ACS 140 frequency converters from 0.12 to 2.2 kw

vacon 100 ac drives application manual

UN2 - Universal controller Building automation s missing link

TOSVERT TM VF-nC3 Parameter List

VSD Series II Variable Speed Micro Drives (VSM II) FS1 FS5

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

STC-KNX (32-channel AP)

KNX ENO 634 (32-channel AP)

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

Control chain diagrams

BACnet Option Module Instruction Manual

Vacon 100 Flow Course

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

Option H2, Modbus communication Automatic Gen-set Controller H SW version 2.33.X

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

vacon nx ac drives all in one application manual

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

ABB machinery drives. Supplement to Users Manual ACS355 Low ambient start (+N828)

SRC-110 Series Zone Controllers with Modbus RTU

TR150 Embedded BACnet Operating Instructions

Scheduled Pumps driven with VFD

MULTISTACK The Modular Water Chiller

DEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description

Control solutions Biofloor

Frequency Inverter CFW500 V1.8X. Programming Manual

1. Vacon Startup Startup Wizard PID Mini-Wizard Multi-pump mini-wizard... 5

MicroManager. Torque Mode CTCW/Loadcell Control. Instruction Manual MM3000-CTCW

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866)

Before you operate the inverter, the parameters that you must first program are the basic parameters.

vacon 100 flow ac drives application manual

Mercury technical manual

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

vacon 100 hvac ac drives application manual

Installation, Programming Operation, & Maintenance Manual V

Inverter Drive /Vector Drive Motors & Controls

AN-SERV-009. Luis Miranda 1

HPVFP High Performance Full Function Vector Frequency Inverter

PARAMETER LIST MICROFUSION

Allen-Bradley. Using the 1756-MO2AE with the TR Encoder (Cat. No ) Application Note

SKDESC-xB Series Electronic Steam Controller

user's manual nx frequency converters beam pump application asfiff13

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Transcription:

BACnet Protocol Implementation Conformance Statement Date: October 06, 2009 Vendor Name: Schneider Electric Product Name: Low Voltage AC Motor Drive Product Model Number: Altivar 61 Application Software Version: v1.2ie05 and upper Firmware Revision: v1.1ie03 BACnet Protocol Revision: 2 Product Description: The Altivar 61 is a high performance adjustable frequency drive specifically designed for HVAC application. This product supports BACnet by an option board, connecting to the MS/TP LAN. BACnet Standardized Device Profile (Annex L): BACnet Operator Workstation (B-OWS) BACnet Building Controller (B-BC) BACnet Advanced Application Controller (B-AAC) BACnet Application Specific Controller (B-ASC) BACnet Smart Sensor (B-SS) BACnet Smart Actuator (B-SA) List all BACnet Interoperability Building Blocks Supported (Annex K): DS-RP-B, DS-RPM-B, DS-WP-B, DS-WPM- B, DM-DDB-B, DM-DOB-B, DM-DCC-B, DM-RD-B Segmentation Capability: Segmented requests supported Window Size Segmented responses supported Window Size Standard Object Types Supported: Object instantiation is static, i.e. objects cannot be created or deleted. Refer to tables at end of document for object details.

Data Link Layer Options: BACnet IP, (Annex J) BACnet IP, (Annex J), Foreign Device ISO 8802-3, Ethernet (Clause 7) ANSI/ATA 878.1, 2.5 Mb. ARCNET (Clause 8) ANSI/ATA 878.1, RS-485 ARCNET (Clause 8), baud rate(s) MS/TP master (Clause 9), baud rate(s): Auto, 9600, 19200, 38400, 76800 MS/TP slave (Clause 9), baud rate(s): Point-To-Point, EIA 232 (Clause 10), baud rate(s): Point-To-Point, modem, (Clause 10), baud rate(s): LonTalk, (Clause 11), medium: Other: Device Address Binding: Is static device binding supported? (This is currently necessary for two-way communication with MS/TP slaves and certain other devices.) Yes No Networking Options: Router, Clause 6 - List all routing configurations, e.g., ARCNET-Ethernet, Ethernet-MS/TP, etc. Annex H, BACnet Tunneling Router over IP BACnet/IP Broadcast Management Device (BBMD) Does the BBMD support registrations by Foreign Devices? Yes No Character Sets Supported: Indicating support for multiple character sets does not imply that they can all be supported simultaneously. ANSI X3.4 IBM /Microsoft DBCS ISO 8859-1 ISO 10646 (UCS-2) ISO 10646 (UCS-4) JIS C 6226 If this product is a communication gateway, describe the types of non-bacnet equipment/networks(s) that the gateway supports:

Object/Property Support Matrix The following tables summarizes the Object Types/Properties Supported: Binary input object instance summary ID Object name Description Active/Inactive Access text Binary input #0 RO 1 ACT Indicates status of relay R1 ON/OFF R Binary input #1 RO 2 ACT Indicates status of relay R2 ON/OFF R Binary input #2 RO 3 ACT Indicates status of relay R3 (1) ON/OFF R Binary input #6 DI 1 ACT Value of LI1 ON/OFF R Binary input #7 DI 2 ACT Value of LI2 ON/OFF R Binary input #8 DI 3 ACT Value of LI3 ON/OFF R Binary input #9 DI 4 ACT Value of LI3 ON/OFF R Binary input #10 DI 5 ACT Value of LI5 ON/OFF R Binary input #11 DI 6 ACT Value of LI6 ON/OFF R Binary input #12 DI 7 ACT Value of LI7 (1) ON/OFF R Binary input #13 DI 8 ACT Value of LI8 (1) ON/OFF R Binary input #14 DI 9 ACT Value of LI9 (1) ON/OFF R Binary input #15 DI 10 ACT Value of LI10 (1) ON/OFF R Binary input #16 DI 11 ACT Value of LI11 (2) ON/OFF R Binary input #17 DI 12 ACT Value of LI12 (2) ON/OFF R Binary input #18 DI 13 ACT Value of LI13 (2) ON/OFF R Binary input #19 DI 14 ACT Value of LI14 (2) ON/OFF R Binary input #20 DI 15 ACT Indicates status of logic output (1) ON/OFF R Binary input #21 DI 16 ACT Indicates status of logic output (1) ON/OFF R (1) : Logic I/O option card terminals (VW3 A3 201). (2) : Extended I/O option card terminals (VW3 A3 202). Binary output object instance summary ID Object name Description Active/Inactive Access text Binary Output #0 RO1 CMD R1 relay out accessible if not assigned ON/OFF C Binary Output #1 RO2 CMD R2 relay out accessible if not assigned ON/OFF C Binary Output 2 RO3 CMD R3 relay out accessible if not assigned (1) ON/OFF C Binary Output #3 RO4 CMD R4 relay out accessible if not assigned (2) -/- C Binary Output #4 RO5 CMD R5 relay out accessible if not assigned -/- C Binary Output #5 RO6 CMD R6 relay out accessible if not assigned -/- C Binary Output #6 RO7 CMD Logic output accessible if not assigned (1) ON/OFF C Binary Output #7 RO8 CMD Logic output accessible if not assigned (1) ON/OFF C (1) : Logic I/O option card terminals (VW3 A3 201). (2) : Extended I/O option card terminals (VW3 A3 202). Analog input object instance summary ID Object name Description Units Access Analog Input #0 ANALOG INPUT 1 Analog input 1 value % R Analog Input #1 ANALOG INPUT 2 Analog input 2 value % R Analog Input #2 ANALOG INPUT 3 Analog input 3 value (2) % R Analog Input #3 ANALOG INPUT 4 Analog input 4 value (2) % R Analog Input #4 ANALOG INPUT 5 Analog input 5 value % R (2): Extended I/O option card terminals (VW3 A3 202).

Analog output object instance summary ID Object name Description Units Access Analog Output #0 AO1 COMMAND Analog output value % C Analog Output #1 AO2 COMMAND Analog output value (2) % C Analog Output #2 AO3 COMMAND Analog output value (2) % C (2): Extended I/O option card terminals (VW3 A3 202). Binary value object instance summary ID Object name Description Active/Inactive Access text Binary Value #0 RUN/STOP ACT Indicates the drive status. READY/RUNS R Binary Value #1 FWD/REV ACT Indicates the motor rotation s direction. FWD/REV R Binary Value #2 FAULT ACT Indicates the drive s fault status. FAULTED/NONE R Binary Value #4 HAND/AUTO ACT Indicates if the drive is locally controller or not. HAND/AUTO R Binary Value #7 DRIVE READY The VSD is ready and waits a start command. NOT READY/READY R Binary Value #8 AT SETPOINT The VSD has reached the target speed. NO/REACHED R Binary Value #10 RUN/STOP CMD Commands a drive start. START/STOP C Binary Value #11 FWD/REV CMD Commands a motor direction s change. FWD/REV C Binary Value #14 FAULT RESET Resets faults RESET/NO C Binary Value #15 MBOX READ Command to read parameter * READ/RESET C Binary Value #16 MBOX WRITE Command to write parameter * WRITE/RESET C Binary Value #18 SP1PRESET Controls C311 ATV61 internal bit OFF/ON C Binary Value #19 SP2PRESET Controls C312 ATV61 internal bit OFF/ON C Binary Value #20 C313CMD Controls C313 ATV61 internal bit OFF/ON C Binary Value #21 C314CMD Controls C314 ATV61 internal bit OFF/ON C Binary Value #22 C315CMD Controls C315 ATV61 internal bit OFF/ON C

Analog value object instance summary ID Object name Description (Code) Units Access Analog value #0 OUTPUT SPEED Output speed Hz R Analog value #1 OUTPUT FREQ Output frequency Hz R Analog value #2 DC BUS VOLT DC bus voltage V R Analog value #3 OUTPUT VOLT Motor voltage V R Analog value #4 CURRENT Motor current A R Analog value #5 TORQUE Motor torque % R Analog value #6 POWER Motor power % R Analog value #7 DRIVE TEMP Drive thermal state % R Analog value #8 KWH (R) Energy counter (erasable) kwh R Analog value #9 KWH (NR) Energy counter (not erasable) kwh R Analog value #10 PRC PID FBCK PID regulator feedback % R Analog value #11 PRC PID DEV PID regulator feedback % R Analog value #14 RUN TIME (R) Operating time H R Analog value #15 MOTOR TEMP Motor temperature % R Analog value #16 INPUT REF 1 Velocity / frequency setpoint from BACnet % C Analog value #18 LAST FLT Error code - R Analog value #19 PREV FLT 1 Previous fault (occurred before LASTFLT) - R Analog value #20 PREV FLT 2 Previous fault (occurred before PREVFLT1) - R Analog value #21 AO 1 ACT Analog output 1 level % R Analog value #22 AO 2 ACT Analog output 2 level % R Analog value #23 ACCEL1 TIME Acceleration time S W Analog value #24 DECEL1 TIME Deceleration time S W Analog value #25 MBOX PARAM Parameter number (1) - W Analog value #26 MBOX DATA Parameter value - W Analog value #27 EXT PID STPT PID regulator setpoint via the bus % C Analog value #28 COM SCAN OUT1 General purpose AV V Comm. Scan. - W Analog value #29 COM SCAN OUT2 General purpose AV V Comm. Scan. - W Analog value #30 COM SCAN OUT3 General purpose AV V Comm. Scan. - W Analog value #31 COM SCAN OUT4 General purpose AV V Comm. Scan. - W Analog value #32 COM SCAN OUT5 General purpose AV V Comm. Scan. - W Analog value #33 COM SCAN OUT6 General purpose AV V Comm. Scan. - W Analog value #34 COM SCAN OUT7 General purpose AV V Comm. Scan. - W Analog value #35 COM SCAN OUT8 General purpose AV V Comm. Scan. - R Analog value #36 COM SCAN IN1 General purpose AV X Comm. Scan. - R Analog value #37 COM SCAN IN2 General purpose AV X Comm. Scan. - R Analog value #38 COM SCAN IN3 General purpose AV X Comm. Scan. - R Analog value #39 COM SCAN IN4 General purpose AV X Comm. Scan. - R Analog value #40 COM SCAN IN5 General purpose AV X Comm. Scan. - R Analog value #41 COM SCAN IN6 General purpose AV X Comm. Scan. - R Analog value #42 COM SCAN IN7 General purpose AV X Comm. Scan. - R Analog value #43 COM SCAN IN8 General purpose AV X Comm. Scan. - R NOTE : For Present Value Access Types, R = Read-only, W = Writeable, C = Commandable Additional functions Besides the services of datasharing the communication card provides the following functions. Full parameters access. By the use of indirect access, it is possible to read or write any of the internal parameters of the VSD. This functionality is assured by these four objects: MBOX DATA, MBOX PARAM, MBOX READ, MBOX WRITE. Reading: Write the logic address of the parameter to the present value property of the object MBOX PARAM. Set present value property of the object MBOX READ to read. The current value of the parameter can be read in the present value property of MBOX DATA.

Writing a parameter: Write the logic address of the parameter to the present value property of the object MBOX PARAM. Write the new value in the present value property of the object MBOX DATA. Set present value property of the object MBOX WRITE to write. Note: MBOX READ and MBOX WRITE automatically return back to inactive once command sent. Always return 0 when read.