Zeiss Axioskop II. The AIF's "routine" light microscope. (Installed 8/24/04)AxioCam installed July 11th 2005

Similar documents
AxioVision 4.5 Brightfield Image Capture Procedure

Nikon E800 Operating Instructions.

Nikon E800 Operating Instructions.

Zeiss Axiovert 135 Fluorescence Microscope Quick Guide / Operations Manual (v. 1.0 February 09)

Characterization Microscope Nikon LV150

Nikon E800 Microscope. Operating Instructions

Motorized Axio Observer Start-up instructions

Zeiss Axio Imager.A1 manual

BX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions

Widefield-NikonEclipseTE200-ORCA Nikon Eclipse TE200 Inverted Microscope with Hamamatsu 1394 Orca-ER Cooled CCD Camera and Micromanager Software

Zeiss LSM 880 Protocol

INSTRUCTIONS FOR COURSE WORK 4 (AxioVert) Instructor: Anne Vaahtokari (MIU) 1. Purpose of the work

EPIFLUORESCENCE &/OR BRIGHTFIELD MICROSCOPY

Using the Nikon TE2000 Inverted Microscope

SHORT INSTRUCTIONS FOR OPERATING LSM1/2 (Zeiss LSM510) AT CIAN Version 1.4, September 2014

CAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE

Simplified Instructions: Zeiss Brightfield Microscope S1000

Zeiss AxioImager.Z2 Brightfield Protocol

Training Guide for Carl Zeiss AxioZoom V16 Stereo Microscope

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

Zeiss Deconvolution Microscope: A Quick Guide

Brightfield Microscopy and Image Acquisition on Spotcam1. by Ryan Taylor/Nancy Kleene Last modified 10/02/05 by Birgit Ehmer

Olympus IX71 Microscope and DP71 Camera Instructions

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

Nikon Eclipse Ti A1-A Confocal Operating Manual. Start-up. Microscope

Zeiss Axioplan 2 imaging microscope and Axiovision software

Instructions for Making On-Line Reservations for Microscopes in NB11-204

QUICKSTART GUIDE: WIDEFIELD WF3 Zeiss Cell Observer Live Cell Imaging System (SAF, ROOM 409) Imperial College London

DIC Imaging using Laser Scanning Microscopes (LSMs) on Axio Imager Stands

Olympus Fluoview 1000S Spectral Confocal Microscope Introduction to the NRI-MCDB Microscopy Facility Spectral Confocal Microscope

Everest System / Slidebook Operating Procedures

DIC Imaging using Laser Scanning Microscopes (LSM) on Inverted Stands

Zeiss AxioObserver with ApoTome

Nikon TE300 Eclipse Wide-Field Microscope

Olympus xcellence Software - basic user guide

Operating Checklist for using the Laser Scanning Confocal Microscope. Leica TCS SP5.

Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING

personal DELTAVISION (pdv)

Quick Start Guide. Leica SP5 X

Nikon C1si Spectral Laser Scanning Confocal Microscope. User Guide

Photography Protocol. Software: ZEN Blue 2012

Guide to Confocal 5. Starting session

Leica DB LB Research microscope and Studo Lite Imaging software

2/4/15. Brightfield Microscopy! It s all about Magnification..! or is it?!

OPERATING INSTRUCTIONS

Takeoff Guide Tutorial to get started with the AxioVision Imaging System (Based on Release 4.8 June 2009)

Jeol JEM Responsible personell: Endy ( ) Online booking is compulsory!

Ch. 1 - Installation Guidelines

Things to check before start-up.

PIXERA InStudio Software Package

Nikon Ti-E Microscope Manual. Rightmire Hall Ohio State University. Director: Tony Brown Rightmire

Leica SP8 TCS Users Manual

QUICKSTART GUIDE: WIDEFIELD HWF1 Zeiss Cell Observer Live Cell Imaging System (HAMMERSMITH, L BLOCK, ROOM 314) Imperial College London

Training Guide for Carl Zeiss LSM 880 with AiryScan FAST

Zeiss LSM 780 Protocol

Training Guide for Carl Zeiss LSM 7 MP Multiphoton Microscope

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

SOP: Polyvar Met Light Microscope

LEICA TCS SP5 AOBS TANDEM USER MANUAL

The following units are required for an ApoTome imaging workstation:

Leica DMI 4000 tutorial

Operating Instructions for Zeiss LSM 510

Standard Operating Procedure

START-UP PROCEDURE 1 THE MICROSCOPE STAND 3 OBJECTIVES 5 STARTING WITH LAS (SOFTWARE) AND SETTING UP THE MICROSCOPE STAND 7

LSM 510 Training Notes

SHORT GUIDE TO LASER MICRODISSECTION USING THE PALM COMBI SYSTEM

LSM 510 Meta Training Notes

Leica TCS SP8 Quick Start Guide

b. Turn the power switch and key to on position for blue laser.

ZEISS LSM 710 CONFOCAL MICROSCOPE USER MANUAL

Leica SP8 TCS Users Manual

User manual for Nikon Elements software

Very short introduction to light microscopy and digital imaging

Proudly serving laboratories worldwide since 1979 SPECIFICATIONS

Zeiss LSM 510 Confocor III Training Notes. Center for Cell Analysis & Modeling

Confocal 510 Tutorial

Dante (Microscope) & Beatrice (Guide) Orth Lab

Widefield 1. Switching on

MIF ZEISS VIOLET CONFOCAL ZEN 2009 PROTOCOL

Leica TCS SL Confocal Training. Neuroscience Imaging Core Staff. Core Director. Facility Manager

Imaging Introduction. September 24, 2010

AxioVision User's Guide. Release 4.1

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s

Using the AmScope Microscope Cameras

Microscope Confocal LSM510 META

TRAINING MANUAL. Olympus FV1000

MetaMorph Imaging Handbook Update 6/4/13

LSM 710 Confocal Microscope Standard Operation Protocol

Nasmyth Ultraview Vox User Protocol

Leica Confocal - 2. Instructions for Leica SP2 Confocal Equipped with Visible Laser Lines

BRIGHTFIELD Olympus TH4-200 Olympus TH4-200 Please keep objectives off touching to avoid their loosening or damage.

ZEISS LSM510META confocal manual

Image-Pro Plus 7.0 Product Note

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

MAKE SURE YOUR SLIDES ARE CLEAN (TOP & BOTTOM) BEFORE LOADING DO NOT LOAD SLIDES DURING SOFTWARE INITIALIZATION

Microscopy from Carl Zeiss

Adobe Studio on Adobe Photoshop CS2 Enhance scientific and medical images. 2 Hide the original layer.

Cell Biology and Bioimaging Core

Standard Operating Procedure (SOP) for Shared Equipment: Spinning Disk Confocal Microscope

Reichert Univar Manual

Transcription:

Zeiss Axioskop II The AIF's "routine" light microscope. (Installed 8/24/04)AxioCam installed July 11th 2005 Featuring: Phase Contrast Darkfield DIC/Nomarski Brightfield Fluorescent filters for Dapi, FITC,Rhodamine Default Objectives: Available upon request: 2.5x objective 1.25x objective 10x objective 5x objective 25x Oil Lens 20x air objective 40x Oil Lens 63x oil objective 100v Oil Lens

Instructions: 1. Turning on the Microscope: 1. SIGN INTO LOGBOOK. 2. Turn on the Mercury Arc Lamp (under the microscope table). THIS MUST BE TURNED ON FIRST. 3. Turn on the transmitted light halogen lamp. 4. Turn on the computer. 5. Select the correct objective for your application. 2. Microscope Configuration:

1. The fluorescence filter turret has several positions that may be used for different imaging applications. Brightfield - no filters are in the light path DAPI FITC Texas-Red DIC analyzer 2. The condenser turret has multiple positions which may be used: 1 for Phase 1(10x) D Darkfield I for DIC (10x and less) I/H for Brightfield 2 for Phase 2 (20x, 25x) II for DIC (40x) 3 For Phase 3 (63x, 100x) III For DIC (63x, 100x) 3. Be sure not to close the Iris Diaphragm too much, it is a common mistake made by many people. If the Iris is closed too much the resulting images will have greatly reduced resolution. 4. The neutral density filters are on the right side of the microscope and settings include (from front to rear): 1.5% ND (reduces light by 1.5%) 6 % ND 25% ND" Diffusion Filter -Should ALWAYS stay in the light path.

5. The transmitted light may be adjusted several ways. The 3200 K setting is bright and should be used to collect a color correct image. Simply, the sample isn't yellowed as it could be with a lower light setting. 3. Using the Microscope: 1. Place the slide on the stage and use oil if the objective is an oil immersion lens only! 2. The condenser lens must be in the light path when using objectives greater than 5x.

3. Focus on your sample. 4. When the sample is in focus align the scope for Koehler illumination, the simple 4 step process described here. 5. You are now ready to image using the digital camera. 4. Using the Axiocam and Zeiss Axiovision Software: 1. Log on to USER account. 2. Doubleclick the Axiovision software icon. 3. Click the workflow toolbar icon to display the following bar along the left side of the computer screen.

5. Switch beam splitter to camera (100% eyes or camera)

6. The camera preview mode has three settings: Slow, Medium and Fast. 7. The fast will allow a video-rate display with very low resolution, whereas the slow setting offers the best resolution (for focusing etc.) Though the slow setting seems to lag behind the actual movement it is suggested that you use it to do your image focusing with it. To change this mode use the pulldown list located near the video camera icon of the preview window. *On the bottom of the image window you must configure the objective magnification. It is extremely important to set this for the objective you are using if you plan on using the Zeiss Software to add a scalebar. If you do not do this your scaling information will be wrong and we'll have no way of determining the scale factor later. 8. Click the "Live" button to start the live preview. 10. Click the "Live Properties" button to display the image properties window. This window has multiple tabs for adjusting various settings: The first and second tabs, Display and Adjust are the most commonly used.

Display tab: The display tab should show a straight black line above the RGB histograms, if it is curved it will affect the image display. To set the line properly just click the "Linear" button. Adjust Tab: The Adjust window is used for setting exposure times and white balance. After focusing on the sample it is a good idea to set the exposure time. Click the "Measure" button to do this.

To set the white balance, click "Interactive" and then use the eyedropper tool to select a white region on the image. If no white area is present move the field, select the white area and return to your sample. Image Acquisition: Once the exposure time and white balance have been set you only need to focus the specimen and then click the "Snap" button on the left panel. We suggest that you immediately save the image to your user folder which is located within the C:\user-files\ folder. Scales may be applied to the image immediately. Note that these will be "burned" into.tif files and cannot be removed. * Saving and opening files with proper scaling information: The files saved as.tif or.zvi will contain the scaling information which was configured above. The pixel dimensions are also posted on the AIF website. To open.zvi files use either the imagej plugin (doesn't recognize scaling information) http://rsb.info.nih.gov/ij/plugins/zvi-reader.html or download the free Zeiss Axiovision LE software available at: http://www.zeiss.com/c12567be0045acf1/contents- Frame/cbe917247da02a1cc1256e0000491172 5. Shutdown: 1. Save images (CD, USB key chain, Zip) 2. Log off of computer. 3. Turn off Scope and HG lamp*. (*Only if no other users have signed up to use the scope within the proceeding 2 hours or more.) 4. Turn off camera (switch). 6. Using DIC/Nomarski and Polarized Light:

1. Align the Prisms 7. Using Fluorescence: 1. Select the correct filter from the turret. 2. Close or turn off the transmitted light, you may use this trick- 3. Open fluorescent light path by moving slider: