MODEL: KS. Plug-in Signal Conditioners K-UNIT

Similar documents
MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: JB2. Plug-in Signal Conditioners M-UNIT

MODEL: W2TS. Mini-MW Series

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: 47LV. Digital Panel Meters 47 Series

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: M2DYS SEN TRONIC AG

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT

MODEL: 48NDV. Bargraph Indicators 48N Series

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

[3] MOUNTING DIRECTION

MODEL: 48NDVD. Bargraph Indicators 48N Series

MODEL: M1EXT. with Display M1E Series

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: DAST-20. Telemetering System

JPQ2 PULSE ACCUMULATOR

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: MRP6. Final Control Elements

MODEL: R30US4. Remote I/O R30 Series

MODEL: M2CEC MODEL: M2CEC-[1][2][3]-[4][5]

MODEL: M5CTC. [4] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) DC Power R: 24 V DC MODEL: M5CTC [1][2][3] [4][5]

JTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

General Specifications

Economical Digital Indicators For Process and Electrical Measurement

General Specifications

MODEL: WL40MW1F. Wireless I/O WL40F Series

MODEL: DLS. Telemetering System

DP2000 ORDERING GUIDE To Order MODEL NO.

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]

PPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation)

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Timers GE1A. GE1A Series ON Delay Timers Single Function

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

n FRONT PANEL CONFIGURATIONS

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

GT5Y Series ON Delay Timers. UL, c-ul Listed File No. E V AC, 3A 30V DC, 3A 220V AC, 0.8A 30V DC, 1.5A 660VA AC 90W DC 176VA AC 45W DC

Model Number Structure

Process displays For standard signals, temperature, resistance measurement

WJM POTENTIOMETER TRANSMITTER BEFORE USE... COMPONENT IDENTIFICATION POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (field-programmable)

Absolute Process Instruments

OMRON MK-I / -S RELAY

General-purpose Relay

RT-3 UNIT RELAY 4-POINT TERMINAL

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

General Specifications

Model Number Structure

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Details on the New G2RS

PARM-SIZED, 16-CHANNEL RELAY TERMINALS


Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550


RT-3 UNIT RELAY 4-POINT TERMINAL

6mm Interface Relays RV8 Series

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

SLIM COMPACT SAFETY RELAY

Model Number Structure

Fuzzy Temperature Controllers E5AF

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

Palm-sized, 16-channel Relay Terminals

Solid-State Digital Counter H7AN

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:

DIGEM f 96 x 48 EK. Applications. Description

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

Adjustable Digital Process Instrument MDK480

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

PID CONTROLLERS LT SERIES

+GF+ SIGNET Temperature Transmitter Instructions

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

MODEL: R7G4HML3. Remote I/O R7G4H Series MECHATROLINK I/O MODULE (MECHATROLINK-III)

WHEN A PLC IS TOO MUCH, AND SPACE FOR

Transcription:

Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided for setpoint adjustments Enclosed relays Relays can be powered 0 V DC Isolation up to 000 V AC High-density mounting Typical Applications Annunciator Various alarm applications K UNIT Model KS SET MONITOR 000% (00VDC) SET HI HI COM 0 (.) * (.) 0 (.) * (.0) for KS- mm (inch) MODEL: KS[][][][] ORDERING INFORMATION Code number: KS-[][]-[][] Specify a code from below for each [] through []. (e.g. KS--B/Q) Special input range (For codes Z & 0) Specify the specification for option code /Q (e.g. /C0/S0) [] INPUT Current A: 0 ma DC ( resistance 0 Ω) A: 0 ma DC ( resistance 0 Ω) B: 0 ma DC ( resistance 00 Ω) C: ma DC ( resistance 000 Ω) D: 0 0 ma DC ( resistance 0 Ω) E: 0 ma DC ( resistance. Ω) F: 0 0 ma DC ( resistance 00 Ω) G: 0 ma DC ( resistance 000 Ω) H: 0 0 ma DC ( resistance 00 Ω) J: 0 0 μa DC ( resistance 000 Ω) K: 0 00 μa DC ( resistance 000 Ω) GW: - ma DC ( resistance 000 Ω) FW: -0 0 ma DC ( resistance 00 Ω) Z: Specify current (See INPUT SPECIFICATIONS) Voltage : 0 0 mv DC ( resistance 0 kω min.) : 0 0 mv DC ( resistance 0 kω min.) : 0 0 mv DC ( resistance 0 kω min.) : 0 00 mv DC ( resistance 00 kω min.) : 0 V DC ( resistance MΩ min.) : 0 0 V DC ( resistance MΩ min.) : 0 V DC ( resistance MΩ min.) : V DC ( resistance MΩ min.) W: -0 0 V DC ( resistance MΩ min.) W: - V DC ( resistance MΩ min.) 0: Specify voltage (See INPUT SPECIFICATIONS) [] OUTPUT : Open collector : Relay; N.O. or make contact : Relay; N.C. or break contact : SSR : Relay; SPDT or transfer contact [] POWER INPUT AC Power B: 00 V AC C: 0 V AC D: V AC F: 0 V AC G: 00 V AC H: 0 V AC J: 0 V AC DC Power S: V DC R: V DC [] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C0: Silicone coating /C0: Polyurethane coating /C0: Rubber coating TERMINAL SCREW MATERIAL /S0: Stainless steel GENERAL SPECIFICATIONS Construction: Plug-in Connection: M. screw terminals http://www.m-system.co.jp/ KS SPECIFICATIONS ES- Rev.0 Page /

Screw terminal: Chromated steel (standard) or stainless steel Housing material: Flame-resistant resin (black) Isolation: to output to power Setpoint adjustments: Multi-turn screwdriver adjustments (front); 0 00% independently Monitor jacks: Output 0 0 V for 0 00 % setpoints Hysteresis (deadband): 0..0 % Front LEDs: Red lights turn on in tripped conditions Power ON timer: The output devices will not be driven for approx. sec. after the power is turned on. INPUT SPECIFICATIONS DC Current: Shunt resistor attached to the input terminals (0. W) Specify input resistance value for code Z. DC Voltage: -00 00 V DC Minimum span: 0 mv Offset: Max.. times span resistance Span 0 00 mv : 0 kω Span 0. V : 00 kω Span V : MΩ OUTPUT SPECIFICATIONS Open Collector: 0 V DC @00 ma Voltage drop: V Relay Contact: 0 V AC @ A (cos ø = ) 0 V AC @0. A (cos ø = ) 0 V DC @ A (resistive load) Maximum switching voltage: 0 V AC or V DC Maximum switching power: 0 VA or 0 W Minimum load: V DC @0 ma Mechanical life: 0 cycles For maximum relay life with inductive loads, external protection is recommended. SSR: 0 0 V AC @0. A Leakage current at OFF: Approx. 0 ma (0 V AC) Alarm Trip Operation Terminal No. in parentheses Output Code :,, Output Code : Output Code : ()ON ()ON 0 0 00 ()ON ()ON 0 0 00 (0)ON ()ON ()ON ()ON 0 0 00 Trip Operation in Power Failure Output Code :,, : both relays turn OFF Output Code : : both relays turn ON Output Code : : Terminals, turn ON INSTALLATION Power input AC: Operational voltage range: rating ±0 %, 0/0 ± Hz, approx. VA DC: Operational voltage range: rating ±0 %, ripple 0 %p-p max., approx. W (0 ma at V) Operating temperature: - to C ( to F) Operating humidity: 0 to 0 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 00 g (0. lb) PERFORMANCE in percentage of span Setpoint monitor accuracy: ± 0. % Temp. coefficient: ±0.0 %/ C (±0.0 %/ F) Response time: 0. sec. (0 00 % at 0 % setpoint) Line voltage effect: ±0. % over voltage range Insulation resistance: 00 MΩ with 00 V DC Dielectric strength: 000 V AC @ minute (input to output to power to ground) http://www.m-system.co.jp/ KS SPECIFICATIONS ES- Rev.0 Page /

EXTERNAL VIEW Hi Adj. Lo Adj. Hi Setpoint Monitor Lo Setpoint Monitor COM. Hi LED Lo LED DIMENSIONS unit: mm (inch) OUTPUT CODE:,,, CLAMP (top & bottom). (.) 0 (.) DIN RAIL mm wide 0 (.). (.) dia. MTG HOLE (.) deep 0 (.) 0 (.) 0 (.0) M. SCREW 0 (.) (.) [. (.)] 0 (.) When mounting, no extra space is needed between units. OUTPUT CODE: CLAMP (top & bottom). (.) 0 (.) DIN RAIL mm wide 0 (.). (.) dia. MTG HOLE (.) deep 0 (.) 0 (.) 0 (.0) M. SCREW 0 0 (.) (.0) [. (.)] 0 (.) When mounting, no extra space is needed between units. http://www.m-system.co.jp/ KS SPECIFICATIONS ES- Rev.0 Page /

TERMINAL ASSIGNMENTS unit: mm (inch) Output Code,, & INPUT RESISTOR (model: REM) (.) shunt resistor attached for current input. Output Code INPUT RESISTOR (model: REM) (.) 0 shunt resistor attached for current input. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Output Code,, & Open Collector N.O. (make) Relay INPUT R * Low Drift Amplifier HI ADJ. COM. HI ADJ. Comparator Base Socket * shunt resistor attached for current input. U() POWER V() N.C. (break) Relay SSR http://www.m-system.co.jp/ KS SPECIFICATIONS ES- Rev.0 Page /

Output Code INPUT R * Low Drift Amplifier HI ADJ. COM. HI ADJ. Comparator Ry Ry N.C. N.O. COM N.C. 0 N.O. Relay Protection AC Powered AD DC Powered AD Inductive Load (Coil) Varistor or Spark Quenching Circuit Inductive Load (Coil) Diode, Varistor or CR Circuit COM U() V() POWER Base Socket * shunt resistor attached for current input. Specifications are subject to change without notice. http://www.m-system.co.jp/ KS SPECIFICATIONS ES- Rev.0 Page /