sch-remote.com EVOR04 Application note: Measure power

Similar documents
Differential Amplifier : input. resistance. Differential amplifiers are widely used in engineering instrumentation

CHAPTER 9. Solutions for Exercises

EE 368 Electronics Lab. Experiment 10 Operational Amplifier Applications (2)

Electronic Circuits EE359A Final project requirements

Embedded Control. Week 3 (7/13/11)

Introduction to Operational Amplifiers

Signal Conditioning Amplifier

TPS TRANSDUCER POWER SUPPLY & LEM IT CURRNET TRANSDUCER

PB 700 PB 1000 PB 1100 PB 1500 PB 2600 PB 1200 PB 1700 PB 2200 PB 2700 USER'S MANUAL.

Module 4 Unit 4 Feedback in Amplifiers

WATT TRANSDUCER. Instruction Manual

Assist Lecturer: Marwa Maki. Active Filters

University of Pittsburgh

Series, Parallel, and Series-Parallel Speaker Wiring

Precision Rectifier Circuits

CPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,

Ten problems to solve before 6 December, 2010

Chapter 1: DC circuit basics

AS Electronics Project: 3-Channel Sound-to-Light Display

True RMS Bench Multimeters 2831E and 5491B

CX1100 Series Current and Differential Sensors

Homework Assignment 13

Tel: (949) Fax: (949) IAA100 Product Manual

Input Modules for TESLA Power System Recorders

School of Sciences. ELECTRONICS II ECE212A 2 nd Assignment

THE SPEAKER. The decibel scale is related to the physical sound intensity measured in watts/cm 2 by the following equation:

Linear Current Sensor with differential outputs

Op Amp Booster Designs

Operation and Maintenance Manual

Mini Evaluation Board for Filterless Class-D Audio Amplifier EVAL-SSM2301-MINI

EE EXPERIMENT 2 ANALOG AND DIGITAL MULTIMETERS INTRODUCTION. Figure 1: Internal resistance of a non-ideal ammeter.

Bridge Measurement Systems

TRANSDUCER INTERFACE APPLICATIONS


Zero Drift, Unidirectional Current Shunt Monitor AD8219

Fluorescent display tube level meter driver, 16-point 2 channel, VU scale, bar display

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

ECE 4670 Spring 2014 Lab 1 Linear System Characteristics

OPERATIONAL AMPLIFIERS (OP-AMPS) II

Sound Generator Jamie Maloway ( ) Polyphon nthesizer

LINEAR IC APPLICATIONS

Signal Conditioning Amplifier

Designing Information Devices and Systems I Discussion 10A

360mm (14-3/16 ) x 224mm (8-13/16 ) x 67mm (2-5/8 )

Half-wave Rectifier AC Meters

True RMS Bench Multimeters 2831E and 5491B

MCTS II Multi Channel Current Transducer System. Installation Manual

Small signal Amplifier stages. Figure 5.2 Classification of power amplifiers

SENSOR AND MEASUREMENT EXPERIMENTS

Examining a New In-Amp Architecture for Communication Satellites

INVESTIGATION AND DESIGN OF HIGH CURRENT SOURCES FOR B-H LOOP MEASUREMENTS

ECE 2274 Lab 2. Your calculator will have a setting that will automatically generate the correct format.

Data Sheet. Hall effect transducers, current and voltage

THERMAL NOISE. Advanced Laboratory, Physics 407, University of Wisconsin. Madison, Wisconsin 53706

The Aleph 2 is a monoblock 100 watt audio power amplifier which operates in single-ended class A mode.

ECE 2274 Lab 2 (Network Theorems)

Making Basic Strain Measurements

Intruder Alarm Name Mohamed Alsubaie MMU ID Supervisor Pr. Nicholas Bowring Subject Electronic Engineering Unit code 64ET3516

Advanced Measurements

Signal Conditioning Systems

Calibration Techniques for the Home Lab

Electronic Troubleshooting. Chapter 5 Multistage Amplifiers

or Op Amps for short

True RMS Bench Multimeter 5492B

Introduction to the Laboratory

AtlasSound.com 1/8 AF " 1.375" 4.125" 2.375" 2.75" 140 Watt Autoformer AF140. Note: The wire colors are for identification purposes only.

SDM3045X Digital Multimeter. DataSheet

Control System Circuits with Opamps

University of North Carolina, Charlotte Department of Electrical and Computer Engineering ECGR 3157 EE Design II Fall 2009

User s Manual ISL71218MEVAL1Z. User s Manual: Evaluation Board. High Reliability Space

CS101. Conducted Susceptibility CS101. CS101 Maximum Current. CS101 Limits. Basis For CS101 Limits. Comparison To MIL-STD Vdc or Less

Integration Guide TPE-500 SERIES. Force Sensing Potentiometer

AUTOMOTIVE CURRENT SENSOR DHAB S/25. Datasheet

Chapter 3 Electronic Circuit for MWCNT Ethylene Sensor

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

IL8190 TECHNICAL DATA PRECISION AIR - CORE TACH / SPEEDO DRIVER WITH RETURN TO ZERO DESCRIPTION FEATURES

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Data Conversion and Lab Lab 1 Fall Operational Amplifiers

8248AU. 4-Ch Isolated Amplifier with Optional Bridge Conditioning FEATURES TYPICAL APPLICATIONS

Current transducer FHS 40-P/SP600

UNIT- IV ELECTRONICS

Zero-Drift, High Voltage, Bidirectional Difference Amplifier AD8207

OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO

Examining a New In-Amp Architecture for Communication Satellites

Special-Purpose Operational Amplifier Circuits

Integration Guide. Force Sensing Potentiometer. To be used in conjunction with current FSP series data-sheets available at

Precision in Practice Achieving the best results with precision Digital Multimeter measurements

Community College of Allegheny County Unit 8 Page #1. Op-Amps

Subwoofer Installation Project

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

NAU82011VG 3.1W Mono Filter-Free Class-D Audio Amplifier. 1 Description VIN. Output Driver VIP. Class D Modulator VDD VSS NAU82011VG

RS Pro DIGITAL MULTI-METER SDM3055 SERIES

DMS Insert Module MSR 282

MP W Mono Class D Low-EMI High- Efficiency Audio Amplifier. Application Note

Basic Analog Circuits

Product Description. SIGnal Workbench. Programmable Signal Conditioning System

EUA6210 Output Capacitor-less 67mW Stereo Headphone Amplifier

Lab 7: DELTA AND SIGMA-DELTA A/D CONVERTERS

Model 176 and 178 DC Amplifiers

Contents. 1 Block Diagram. 2 Specifications. 3 Unipolar vs. Bipolar Interconnections. 4 Inexpensive Bipolar Power Supply Alternative.

Transcription:

sch-remote.com EVOR04 Application note: Measure power

Overview In many audio applications is need to measure the true output power of amplifier, independently of load characteristics. Also opposite case is common - to measure the power produced by speakers, without considering amplifier type. Subject of measurement can be the average rms power or peak power over a very short time. Since firmware revision 1.1 EVOR04 provide a way to achieve such measurements over a single channel. Table of contents Theory of operation...3 Current sensing...4 Selecting voltage divider and current rating...5 Setup of EVOR04 input signal...6 sch-remote.com EVOR04 Measure power 2

Theory of operation To obtain the power of amplifier or over load is need to get the voltage across it and the current passing between amplifier and load. EVOR04 module has 2 channels input and dedicating one for voltage and other for current is possible to process and display the rms or peak power of single source. Also one of the channels can be switched in differential mode and using the extra inputs can measure the voltage over a bridged mode amplifier. The effects able to work in power mode are VU meter and Analog VU meter. They are able to display exact power in watts on their scale. From ground connection point of view exist 2 types of power amplifiers: Normal mode Here the amplifier and load share a common, system ground over the one of the wires and the other is floating across the supply voltage according to the input signal. The voltage divider network R1-R2 lower the output voltage range to acceptable level. The voltage across shunt resistor is proportional to the current passing trough it. That voltage is passed in differential mode to EVOR04. This prevent a error from voltage drop over the wires or eventual current monitor inside the amplifier. Shunt resistor should be placed over the ground wire to keep the voltages across it close to ground. A special care should be taken to keep the shunt resistor always connected to ground, because lack of such connection can cause a high voltages to appear on EVOR04 inputs. If is convenient, shunt resistor can be replaced by current transformer or hall effect current sensor. sch-remote.com EVOR04 Measure power 3

Bridged mode The both sides of load are floating across the supply voltage, powered by 2 internal amplifiers driven in opposite phase. That circuit produce doubling of output voltage. Here are need two voltage dividers - R1-R2 and R3-R4, for each side of the bridge. The signal from them is measured in differential mode from EVOR04. The current passing trough load is measured with current transformer or hall effect current sensor. Bridged mode schematic is possible to be used in normal mode system, as reading of 0V from one side will not affect the final measurement. If EVOR04 module not share a common ground with other components, also normal mode schematic can be used for bridged mode system. A special care should be taken to not share a ground trough a power supply or USB cable for example, thus it will cause a serious damage. Current sensing In all schematics, key point is to convert the current into proportional voltage. Shunt resistor is most simple and cheaper solution. Main drawback of it is, that to get bigger voltage across it, means a bigger power looses over it which can heat it to very high temperatures. Also to keep voltages across it low, one of its sides should be always connected to ground, which make it unacceptable for bridged mode. Current transformer can be used for very high currents, without any heat or power looses over it. It need just a extra resistor that will control the voltage drop across it. Main disadvantage is its limited frequency response. Usually they are produced for power lines of 50-400Hz and finding a model for audio applications can be harder. Hall effect current sensor solution seems to be most reliable option. It has wide frequency response and handle heavy currents. Only need to consider that it need external power and some sch-remote.com EVOR04 Measure power 4

extra components. A very popular sensors of that type are ACS712 and ACS756 ICs. Below is given a sample schematic with ACS712ELECTR-30. Selecting voltage divider and current rating Wide range of amplifiers power and load impedance gives very wide range of output voltage and currents. Tables below gives what should be the rms voltage and current for a given amp power and load. Vamp RMS voltage by power and load U = P.R 25 W 50 W 100 W 150 W 200 W 250 W 500 W 750 W 1000 W 2 Ω 7,1 V 10,0 V 14,1 V 17,3 V 20,0 V 22,4 V 31,6 V 38,7 V 44,7 V 4 Ω 10,0 V 14,1 V 20,0 V 24,5 V 28,3 V 31,6 V 44,7 V 54,8 V 63,2 V 6 Ω 12,2 V 17,3 V 24,5 V 30,0 V 34,6 V 38,7 V 54,8 V 67,1 V 77,5 V 8 Ω 14,1 V 20,0 V 28,3 V 34,6 V 40,0 V 44,7 V 63,2 V 77,5 V 89,4 V 16 Ω 20,0 V 28,3 V 40,0 V 49,0 V 56,6 V 63,2 V 89,4 V 109,5 V 126,5 V Iamp RMS current by power and load I = P R Voltage divider EVOR04 accept input signals from 2.2mV up to 2V. Very low voltages will impact the signal to noise ratio. Levels between 0.2V to 2V are acceptable for best performance. The formula for ratio between R1 and R2 is 25 W 50 W 100 W 150 W 200 W 250 W 500 W 750 W 1000 W 2 Ω 3,5 A 5,0 A 7,1 A 8,7 A 10,0 A 11,2 A 15,8 A 19,4 A 22,4 A 4 Ω 2,5 A 3,5 A 5,0 A 6,1 A 7,1 A 7,9 A 11,2 A 13,7 A 15,8 A 6 Ω 2,0 A 2,9 A 4,1 A 5,0 A 5,8 A 6,5 A 9,1 A 11,2 A 12,9 A 8 Ω 1,8 A 2,5 A 3,5 A 4,3 A 5,0 A 5,6 A 7,9 A 9,7 A 11,2 A 16 Ω 1,3 A 1,8 A 2,5 A 3,1 A 3,5 A 4,0 A 5,6 A 6,8 A 7,9 A R1 R2 =Vamp Vtarget Vtarget. If select Vtarget to be 1Vrms, the ratio between resistors is just Vamp-1. In bridged mode R1=R4 and R2=R3. Using a lower resistor values is better for noise performance and accuracy, but will increase the looses across them. For safety operation select R1 range depending on Vamp voltage. Vamp 30 V 60 V 90 V 120 V 150 V R1 10-47 kω 33-100 kω 82-180 kω 150-330 kω 220-680 kω sch-remote.com EVOR04 Measure power 5

Example: If Vamp = 54.8V, the ratio R1/R2 = 53,8. We should select R1 between 33 and 100 kω. Selecting R1=33kΩ and R2=620Ω gives the closest ratio to the needed. Current rating For current sensing is not always possible to select a shunt that perfectly match the maximum current of the amplifier. There should be installed always a shunt for bigger current and right calibration to be made trough EVOR04 gain setup. Typically resistor shunts give 75mV for their maximum rated current, but also a 50mV and 100mV versions can be found. Key parameter, used in following calculation is their sensitivity. A shunt of 20A 75mV has sensitivity of 0.075/20 V/A = 3,75 mv/a. For current transformers are specified their turns ratio and rated burden resistance. Dividing the values gives us the sensitivity. For example a 750:1 turns ratio and 33Ω rated resistance gives a 33/750 V/A = 44 mv/a sensitivity. Hall effect sensors have given their sensitivity in their datasheet. For example ACS712ELECTR-30 has 66mV/A. Knowing the nominal current of amplifier and sensitivity is easy to find what will be the voltage of EVOR04 input for that current. For example 11,2A nominal current and 44 mv/a sensitivity gives a 0.493V on input. Next step is to find required gain correction for that voltage, using following formula: G=20.log( 2 Vin ). For Vin=0.493V required gain is G=12.2 db. From interface can be selected closest value of 12 db. Using current or hall effect sensor is possible the output voltage of them to be higher than maximum allowed voltage of 2Vrms for EVOR04. In this case can be easy added a resistor divider network and adjust sensitivity according it. Setup of EVOR04 parameters 2 Chanel A boost and gain should be 6dB if Vtarget = 1Vrms. Or G=20.log( Vtarget ) if used different target voltage. Chanel B boost and gain should be the value calculated from Current rating section. For normal mode Channel A input is L1 Channel B input is Differential Differential source is L2-R2 For bridged mode Channel A input is Differential Channel B input is R2 Differential source is L1-R1 Nominal value of Power mode inside VU or Analog VU effects is the amplifier rated power from where calculations start. Because the resistor divider ratio and gain selection cannot always match perfectly the calculated values, it is better to calculate exact power, eliminating these errors, according following formula: GchB GchA 20 P=10.2. R1+R2 20 10.2. R2 CTsensitivity(V / A) Example result according previous calculations: 16 6 20 P=10.2. 33000+620. 10 20. 2 620 0,044 =620,6W In interface can be set 621W. sch-remote.com EVOR04 Measure power 6