Advanced Test Equipment Rentals ATEC (2832) Lightning Surge Simulator LSS-F02.

Similar documents
Lightning Surge Simulator LSS-F03 series

Fast transient burst simulator

Compliance to a standard or to the real world?

Automotive Transient Surge Simulator conforming to ISO ISS-7600 Series

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent

Technical Specification

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent

Fast Transient / Burst Simulator

Insulation Test System

ELECTRICAL SAFETY TESTERS. Wings for Your Projects. APPLICATION NOTE

Insulation Test System

Schlöder GmbH - EMC Test and Measurement Systems Model #

Surge Generator for MIL-STD 1275

CAR - TEST - SYSTEM 14

Technical Specification

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing

Fixed Series Compensation

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

INTERNATIONAL STANDARD

Advanced Test Equipment Rentals ATEC (2832)

Novità sulla IEC ; -10; -12

Substation Preventive Maintenance

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Voltage Transient Emission Test

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M

A Solid Foundation for Reliable, Safe and Practical Safety Compliance Testing.

EMC standards. Presented by: Karim Loukil & Kaïs Siala

LEAK CURRENT HiTESTER ST5540/ST Washington Street Melrose, MA Phone Toll Free

MILITARY & AEROSPACE TESTING

Datasheet Electrical Safety Tester

IEC Electrical fast transient / Burst immunity test

Proposal of double voltage transmission line pulse generator using four coaxial cables

1. General Instructions 2 2. Safety 2 3. Lamp Starting Test Instrument LSTI 5 3

Combination Wave Test System

Telecom Test System. Lightning Tests

Insulation Testers and Earth Ground Testers

MEDIUM & HIGH VOLTAGE

The power line carrier equipment will provide speech, telecontrol and teleprotection channels over 50 Hz, 132 KV transmission systems.

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

MIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA

INDEX. 1. Electrostatic discharge immunity test E-1 ~ 2 (IEC )

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

INSULATION / WITHSTANDING Test Instrument series 3153/3159/ST5520

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

DM-45 Digital Multimeter

change (PABX) systems. There must, however, be isolation between and the higher voltage, transientprone


LS200 TEST DATA IEC61000 SERIES

MS2030 CAT III 600 V A V AUTO RS232

Transformers connected via a cable Overvoltage protection

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. :

Advanced Test Equipment Rentals ATEC (2832)

DCD ST - SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION LINES (COMMUNICATION LINES)

Testers: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery:

DL-91 DL-92 DL-94 DL-97

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291

DCD SR - SERIES COUPLING/DECOUPLING NETWORKS FOR UNSHIELDED UNSYMMETRICAL INTERCONNECTION LINES

SIOV metal oxide varistors

C.A 6115N. Safety at all costs. IEE 16th: Electrical installation IEC/EN I E C. Insulation RCD. Earth. Loop. Continuity.

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents

INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Wide-band Models from DC to 100 MHz

Holiday Detector mod. 184/45KV

CATALOG including...

2520 Pulsed Laser Diode Test System

Advanced Test Equipment Rentals ATEC (2832) INA A

MR461 MR561 AC/DC OSCILLOSCOPE CURRENT PROBES. User Manual. AC/DC CURRENT PROBE Model MR 561. AC/DC CURRENT PROBE Model MR V CAT III - 600A

Eurotest 61557, Instaltest 61557

SPECIFICATION FOR APPROVAL

Fluke and

NT & NQ CLASS II TRANSFORMERS FOR SIGNALLING SYSTEMS. A Balfour Beatty and Alstom Company

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Application Note 1024

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan

Model UT511 OPERATING MANUAL

Fluke 123/124 Industrial ScopeMeter

Electrical Measuring Instruments. Vol.3.

Avionics Test System. Lightning Tests

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Instruction Manual for Digital Grounding Resistance Meter

MODEL: DAST-20. Telemetering System

PE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments

Fluke 1623 and GEO Earth Ground Testers. Technical Data. Stakeless testing

V1.3. TBLC08 50mH AC-LISN TBLC08

Research on State Estimation and Information Processing Method for Intelligent Substation

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Bipolar Output Working Standard

OIML E 5 EXPERT REPORT. 6th Edition 2015 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

DMM8900 SERIES USERS MANUAL

DECLARATION OF CONFORMITY

Conducted Immunity Testing

High Stability Voltage Source

INSULATION TESTER SERIES

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

Transcription:

Lightning Surge Simulator Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) LSS-F02 www.noiseken.com

Conforming to IEC61000-4-5 ed2 Standard LSS-F02 series A simulator to reproduce High energy induced lightning noise which is induced by potential change on the ground, or done to power lines or telephone lines as result of lightning current. Dedicated to evaluate performance of electronic equipments which are connected to power lines and telephone lines come from the outdoors or interconnection lines between buildings and the others or the floors and the other floors whether the equipments may be malfunctioned, deteriorated or resistible. Pole transformer Distributing substation Distributing substation Switch-board To residential switch-board Light Combined machine (Copy, fax, scanner) 変圧器 (Power supply lines) Switching noise, Conducted noise FNS, INS, LSS, VDS series Inflow direction of noise Breaker Tester, Production machine, etc. (3-phase power supply) Switch-board (Communication lines) Switching noise, Conducted noise FNS, INS, LSS (* Coupling clamp is necessary) Inflow direction of noise * 3-phase power supply applies to production machine and large sized tester in factories Applicable simulators are also required for corresponding to 3-phase ET Exchanger (PBX) Noise inflow image into a residence Noise inflow image into a factory SRGE OT SRGE OT ET LINE OT LINE OT Wooden table Test setup to consumer appliances Test setup to industrial equipments SRGE OT Protective Safety Box Capacitor, varistor, arrester, diode, etc. ET SRGE OT ET LINE OT Wooden table Test setup to electronic components 2 www.noiseken.com Test setup to automotive devices

Feature of LSS-F02 : "More safety, reliable and easy test realized" "Output voltage 15kV, current 7500A" which can conduct breakdown resistibility test Approx. 60% of the users are carrying on the test with voltage more than IEC Standard. Requirement in IEC Standard < To keep up with quality in the market "50% reduction of the output interval" which can drastically reduce the test time Realize 1/2 of the interval time comparing to our previous models so as to contribute to reduction of the man-hour for the test. (* in case of the test less than 6kV output) Test voltage of lightning surge immunity test Previous models 4kV <4kV nknown LSS-F02 Reduced 0 5 10 15 20 25 (sec) Repetition cycle Quoted from the market investigation by NoiseKen on 2010 "Touch-panel" adopted for the easy test setting Adopt LCD touch panel for pursuing high visibility and realizing user-friendly operation with affluent icons. Also, easy operation is realized not only for the test according to IEC Standard but also for the sequential tests with the parameter sweep function. "Multi-languages" for the easy operation processing available Not only Japanese and English but also Chinese and Korean available for the easy operation processing. Japanese English Chinese Korean www.noiseken.com 3

Feature of LSS-F02 : "More safety, reliable and easy test realized" "Indicator" which is linked with the test setting equipped Indicators which visualize the cables connections in the test equipped. PC control available with the optional software Enable to control from external Windows PC. Also, enable to put the report of the test result in record out. "Emergency stop" & "Interlock terminal" which secure the test operator equipped. Emergency stop function which takes safety of the test operator into the account equipped both in the main body and the software. Also, the interlock setting and output voltage control function equipped. If the protective safety fence and protective safety box are adopted as the options, more safety test can be realized. "Output waveform monitor terminal" which can ease pre-checking of the waveforms prior to the actual test In order to respond to the request "The simple waveform checking is desired before the test", equip the monitor terminal. * The terminal is just for the simple checking. If the accurate measurement is required, the specialized equipments are necessary. Please contact us for the more details. Emergency stop switch Powered condition of ET ON/OFF selectable Oscilloscope ch1 ch2 Interlock terminal 4 www.noiseken.com

How to understand the model numbers LSS-F02-1 : Model for single phase ET L/N/ 3 : Model for 3-phase ET L1/L2/L3/N/(Available both for single phase & 3-phase) A : 1.2/50μs-8/20μs (Totally 1 kind surge generates) C : 1.2/50μs-8/20μs 10/700μs-5/320μs (Totally 2 kinds) LSS-F02 series specification Specification Parameter Specification Note Surge generating unit 1.2/50μs-8/20μs Output voltage 0.5kV ~ 15kV ±10% Combination waveforms Front time 1.2μs ±30% Common for the all models Duration 50μs ±20% Voltage step : 0.1kV step Output current 250A ~ 7500A ±10% The setting can be from 0kV Front time 8μs ±20% Duration 20μs ±20% 10/700μs-5/320μs Output voltage 0.5kV ~ 15kV ±10% Combination waveforms Front time 10μs ±30% Models:C1/C3 Duration 700μs ±20% Voltage step : 0.1kV step Output current 12.5A ~ 375A ±10% The setting can be from 0kV Front time 5μs ±20% Duration 320μs ±20% Output polarity Positive / Negative Interval 10 sec.~989 sec., depending on the set voltage 10 sec. (< 6kV) 15 sec.~ in 10/700μs waveform Output impedance 2Ω ±10% 1.2/50μs waveform 40Ω ±10% 10/700μs waveform /DC CDN Coupling surge waveform 1.2/50μs-8/20μs combination waveforms Max. coupling surge voltage / current p to the values which can be set Coupling network 18μF Between LINE - LINE (10Ω +9μF selectable) Correspondent to IEC61000-4-5 10Ω ±9μF Between LINE - (18μF selectable) Injection mode Between LINE - LINE, Between LINE - Power supply lines structure for ET Single phase :L/N/ Model : A1 / C1 DC :+/-/ 3-phase :L1/L2/L3/N/(Common for single phase and 3-phase) Model : A3 / C3 DC :+/-/ ET power capacity 240V/20A MAX 50/60Hz DC125V/20A MAX Model : A1 / C1 500V/50A MAX 50/60Hz DC125V/50A MAX Model : A3 / C3 Decoupling coil 1.5mH Phase angle control 0 ~ 360 ±10 CDN for Telecom lines (Only in model C1 and C3) Coupling surge waveform 1.2/50μs-8/20μs combination waveforms 10/700μs-5/320μs combination waveforms Max. coupling surge voltage / current p to the values which can be set Impedance matching resistors 40Ω 80Ωper 1 line at 2 lines 1.2/50 μs waveform 160Ωper 1 line at 4 lines 25Ω 50Ωper 1 line at 2 lines 10/700 μs waveform 100Ωper 1 line at 4 lines Coupling mode Common mode / Normal mode Coupling network Gas arrestor : 90V Line for ET 2 lines / 4 lines DC50V/100mA MAX Selectable Decoupling coil 20mH Others Voltage monitor BNC output, 1/2000±10% In open-circuit for SRGE OT Current monitor BNC output, 1mV/A±10% In short-circuit for SRGE OT External communication RS-232C optical communication Power supply 100V ~ 240V ±10% 50Hz / 60Hz Dimension W555 H1800 D790 mm Projection excluded (in all models) Mass Approx. 300kg Model : A1 / A3 Approx. 340kg Model : C1 / C3 Standard accessory Item Specification / Function Q'ty Correspondent model Surge output cable HOT / COM 2 pcs. Common Output cable to power supply lines For single phase : L / N / 3 pcs. A1/C1 For 3-phase : L1 / L2 / L3 / N / 5 pcs. A3/C3 Output cable to telecom lines For 1~4 lines and GND 5 pcs. C1/C3 Arrestor unit For coupling : Equipped to main unit panel 4 pcs. C1/C3 For input protection : Equipped to main unit panel 4 pcs. Cable for monitor BNC-BNC cable 1 pc. Common External interlock connector 5P plug (Short between #1 - #3) 1 pc. Common Power supply cable For 100V, 3P equipped with G connector cable 1 pc. Common High voltage connector cap Equipped to main unit panel 5 pcs. A1/C1 7 pcs. A3/C3 FG cable For grounding the body 1 pc. Common Instruction manual - 1 volume Common These products use parts containing mercury. Please comply with lows or regulation in countries or states the products are used for the disposal. Certain periodical inspection shall be recommended since consumable parts are contained in the products. In the test to 3-phase 5 lines (with ) power supply lines, a message which alert the inspection per around 200 sets (in the test to single phase (with ) power supply lines, it is done per around 800 sets). (1 set in this case means that the test shall be done with 2 levels (eg. 0.5kV and 1kV) for the test series according to IEC61000-4-5) * Exchange timing of the parts may differed depending on the operative conditions and environment. Please contact us for the more details. www.noiseken.com 5

Option CDN for Interconnection Lines sed for the surge test to interconnection lines defined in IEC61000-4-5 Standard. The ET power capacity is DC50V/1A and enable to inject the surge to interconnection lines up to 6,600V. Possible to bypass inductor (20mH) with connecting the attached connection plug to inductor bypass terminal in DC output. Possible to equip the attached surge protective arrestor between each line and ground. * The conversion (05-H1784)cable is needed additionally. Parameter Specification Surge input voltage 500V~6.600V (Combination wave) ET power capacity DC50V/1A Max. line number 4 lines Decoupling coil 20mH each line Impedance matching resistor 40Ω ±10% Dimension / Mass (W)488 (H)456 (D)550mm Approx. 45kg * Both capacitor coupling and arrestor coupling are possible in LSS-INJ6400SIG. Diode coupling which is defined in IEC61000-4-5 ed.2 (2005) newly is a test method which assumes the injection of dozens of voltage level surge to interconnection lines. Please contact us if low voltage surge injection is required since the surge injection in LSS-INJ6400SIG can be more than 90V. Isolation Transformer Maximum capacity is single phase 240V / 30A and the dielectric strength is 4kV Available for lines power supply in LSS-F02 series and widely usable for the other various noise generators or measurement equipments. Parameter Specification Max. input voltage Single phase 240V MAX (50 / 60Hz) Max. output voltage 30A MAX Dielectric strength Primary to core : 4kV (1 minute) Secondary to core : 4kV (1 minute) Primary Secondary : 4kV (1 minute) Insulation resistance 100MΩ at DC500V Dimension / Mass (W)350 (H)475 (D)400mm (Eye bolts and handles excluded) Approx. 60 kg Warning Lamp sable together with LSS-F02 series. The blinking makes the operators or neighbors pay attention to the test processing. Isolation Transformer Maximum capacity is 3-phase 600V / 50A and the dielectric strength is 4kV Available for lines power supply in LSS-F02 series and widely usable for the other various noise generators or measurement Parameter Specification Max. input voltage Single phase / 3-hase 240V MAX (50 / 60Hz) Transformer connection Y-connection Max. output voltage 50A MAX Dielectric strength Primary to core : 4kV (1 minute) Secondary to core : 4kV (1 minute) Primary Secondary : 4kV (1 minute) Insulation resistance 100MΩ at DC500V Dimension / Mass (W)500 (H)640 (D)700mm (Eye bolts and handles excluded) Approx. 350 kg Protective Safety Fence Enable to materialize the safe test environment with connection to interlock function equipped in LSS-F02 series. The safety measure can be sure together with the ET protective safety box. Waveform Pre-Checking Cables Set Fixtures for checking voltage waveforms and current waveforms of LSS-F02 series. Followings are necessary for the checking additionally. Oscilloscope (Differential operation function built-in) High voltage probes (for surge voltage measurement / Voltage resistibility necessary) Current probe (For surge short current measurement) (for oscilloscope) Earth cable (for connection) Oscilloscope which enables differential measurement Power supply HOTch1ch 2COMSurge Optical SB module Optical conversion adaptor sed for remote control with PC. 5m of optical fiber cable with SB interface attached. ET Protective Safety Box Protection box to prevent access to ET during the test. Further safety is secured together with the safety protective fence ch1 ch2 Grounding conductor High voltage probe X 2 pcs. Connect GND of high voltage probe Isolation transformer noncontact Terminal Connection Board attached with Multi-Outlet (3p) Relay terminal board to connect output of LSS-F02 series to ET. Enable to connect any outlet figure in the world when wiring to the attached multi-outlet. For single phase 3 lines (Voltage resistible capacity 4.5kV) * The same option for 3-phase 5 lines also available (18-00058B) 6 www.noiseken.com

Reference Summary of IEC61000-4-5 ed2.0 Standard 1. General The task of the described laboratory test is to find the reaction of the ET under specified operational conditions, to surge voltages caused by switching and lightning effects at certain threat levels. This standard specifies 2 kinds of the combination waveforms. One is simulating the injection to power supply lines and interconnections lines (The voltage waveform as 1.2/50μs and current waveform as 8/20μs) and the other is doing the injection to telecommunications lines (The voltage waveform as 10/700μs and current waveform as 5/320μs). It is not intended to test the capability of the ET s insulation to withstand high-voltage stress, direct injections of lightning currents, i.e., direct lightning strikes, are not considered in this standard. 2. Test Level Level Open-circuit test voltage±10% (kv) 1 0.5 2 1.0 3 2.0 4 4.0 x special * X can be any level determined by consent between the ET manufacturer and the simulator supplier 3. Waveforms Generator and Waveforms verification 1.2 / 50 Combination Waveform (1.2/50-8/20μs) Generation Circuit 10 / 700 Combination Waveform (10/700-5/320μs) Generation Circuit Rc Rm Lr Rc Rm1 Rm2 Cc Rs1 Rs2 Cc Rs Cs S1 Rc Cc Rs Rm Lr High-voltage source Charging resistor Energy storage capacitor (20μF) Pulse duration shaping resistors Impedance matching resistor Rise time shaping inductor Rc Cc Rs Rm Cs S1 High-voltage source Charging resistor Energy storage capacitor (20μF) Pulse duration shaping resistor Impedance matching resistors (Rm1=15Ω:Rm2=25Ω) Rise time shaping capacitor (0.2μF) Switch closed when using external matching resistors Voltage Surge (1.2/50μs) 1.0 0.9 Voltage Surge (10/700μs) 1.0 0.9 0.5 0.5 0.3 A 0.3 A 0.0 T 30% max. t 0.0 T t T1 T1 Front time : T1=1.67 T=1.2μs ±30% Time to half-value : =50μs ±20% Front time : T1=1.67 T=10μs ±30% Time to half-value : =700μs ±20% Current Surge (8/20μs) 1.0 0.9 Current Surge (5/320μs) I/Imax 1.0 0.9 0.5 0.3 0.5 0.1 0.0 T 30% max. t 0.1 T1 Front time : T1=1.25 T=8μs ±20% Time to half-value : =20μs ±20% 0.0 O1 T t Front time : T1=1.25 T=5μs±20% Time to half-value : =320μs±20% www.noiseken.com 7

Voltage waveform specification at the ET port of the coupling/decoupling network Coupling impedance Surge voltage parameters under open circuit conditions 18μF 9μF+10Ω Front time 1.2μs±30% 1.2μs±30% Time to half value Current rating < 25 A 50μs+10μs/-10μs 50μs+10μs/-25μs Current rating 25 A 60 A 50μs+10μs/-15μs 50μs+10μs/-30μs Current rating 60 A 100 A 50μs+10μs/-20μs 50μs+10μs/-35μs NOTE The measurement of the surge voltage parameters should be done with the power supply input port of the coupling/decoupling network open-circuit. Current waveform specification at the ET port of the coupling/decoupling network Coupling impedance Surge current parameters under short circuit conditions 18μF 9μF+10Ω Front time 8μs±20% 2.5μs±30% Time to half value 20μs±20% 25μs±30% NOTE The measurement of the surge current parameters should be done with the power supply input port of the coupling/decoupling network open-circuit. 4. Test Setup Injection to power supply lines Injection to telecom lines and power supply lines SRGE OT LINE OT ET SRGE OT LINE OT TEL LINE OT ET Wooden table Wooden table Injecting 1.2/50 combination wave put out from CDN of LSS-F02 to battery drive of a PC. Floating circuit is adapted according to the Standard for the output. In LSS-F02 series, enable the automated operation with the program function along the above figure. Injecting 1.2/50 combination wave and telecom surge (10/700 combination wave) put out from CDN of LSS-F02 to power supply lines and telecom lines of a fax machine. In LSS-F02 series, enable the automated operation with the program function along the above figure. * The above setup figure is one example of the test setup our lightning surge simulator. There is no specification on the Standard. * Designs and specifications are subject to be changed without notice. Noise Laboratory Co., Ltd. 1-4-4 Chiyoda, Chuo-ku, Sagamihara City, Kanagawa Pref. 252-0237 Japan RL : http://www.noiseken.com International Sales & Marketing Section TEL : +81-(0)42-712-2051/FAX : +81-(0)42-712-2050 E-mail : sales@noiseken.com