TVS 3KP SERIES GPP TRANSIENT VOLTAGE SUPPRESSOR 3 WATT PEAK POWER 8. WATTS STEADY STATE FEATURES * Plastic package has underwriters laboratory * Glass passivated chip construction * 3 watt surage capability at 1ms * Excellent clamping capability * Low zener impedance * Fast response time R-6 1. (25.4).52 (1.3) DIA..48 (1.2).36 (9.1).34 (8.6).36 (9.1).34 (8.6) DIA. MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 o C ambient temperature unless otherwise specified. 1. (25.4) Dimensions in inches and (millimeters) DEVICES FOR BIPOLAR APPLICATIONS For Bidirectional use C or CA suffix for types 3KP thru 3KP1 Electrical characteristics apply in both direction MAXIMUM RATINGS (At TA = 25 o C unless otherwise noted) RATINGS SYMBOL VALUE UNITS Peak Pulse Power Dissipation with a /us waveform (Note 1, FIG.1) PPPM Minimum 3 Watts Peak Pulse Current with a /us waveform (Note 1, Fig. 3) SEE TABLE 1 Amps Steady State Power Dissipation at TL = 75 o C lead lengths.375 (9.5mm) (Note 2) PM(AV) 8. Watts Peak Forward Surge Current, 8.3ms single half sine wavesuperimposed on rated load( JEDEC METHOD ) (Note 3) IFSM 25 Amps Operating and Storage Temperature Range TJ, TSTG -55 to + 175 C NOTES : 1. Non-repetitive current pulse, per Fig.3 and derated above TA = 25 o C per Fig.2. 2. Mounted on copper pad area of.8 X.8 ( 2 X 2mm ) per Fig. 5 3. Measured on 8.3mS single half sine-wave or equivalent square wave, duty cycle = 4 pulses per minute maximum. 29-2 REV: O
RATING AND CHARACTERISTIC CURVES ( 3KP THRU 3KP1A ) PPPM, PEAK PULSE POWER, kw 1. FIG. 1 - PEAK PULSE POWER RATING CURVE Non-Repetitive Pulse Waveform Shown in Fig.3 TA = 25.1.1uS 1.uS us us 1.mS ms TP, PULSE WIDTH, sec PEAK PULSE POWER (PPP) OR CURRENT (IPP) DERATING IN PERCENTAGE,% FIG. 2 - PULSE DERATING CURVE 75 5 25 2 5 5 75 125 15 175 2 TA, AMBIENT TEMPERATURE,( ), PEAK PULSE CURRENT,% 15 5 FIG. 3 - PULSE WAVEFORM tr = usec. Peak Value Pulse Width (td) is Defined as the Point Where the Peak Current Decays to 5% of HALF VALUE - 2 /usec. Waveform as Defined by R.E.A. CJ, CAPACITANCE, pf FIG. 4 - TYPICAL JUNCTION CAPACITANCE f = 1. MHz Vsig = 5mVp-p TJ = 25 Measured at,vwm Measured at Zero Bias td 1. 2. 3. 4. t, TIME,mS 1. 2 V(BR), BREAKDOWN VOLTACE, VOLTS PM(AV), STEADY STATE POWER DISSIATION, WATTS 8 6 4 2 FIG. 5 - STEADY STATE POWER DERATING CURVE L =.375"(9.5mm) Lead Lengths.8X.8X.4" (2X2mm) Copper Heat Sinks 6Hz Resistive or Inductive Load 25 5 75 125 15 175 2 TL, LEAD TEMPERATURE ( ) IFSM, PEAK FORWARD SURGE CURRENT AMPERES 3 25 2 15 5 FIG. 6 - MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT UNIDIRECTIONAL 8.3ms Single Half Sine-Wave (JEDED Method) 1 NUMBER OF CYCLES AT 6 Hz
TRANSIENT VOLTAGE SUPPRESSORS 3W SERIES TVS DIODES/R-6 ( CASE 12 ) 3W TYPE Breakdown VBR MAX. @IT (ma) VWM Leakage at VWM ID(uA) Peak Pulse Current (Amps) Clamping at VC 3KP 6.4 7.3 5 2 312.5 9.6 3KPA 6.4 7. 5 2 326 9.2 3KP6. 6.67 8.15 5 6. 5 263 11.4 3KP6.A 6.67 7.37 5 6. 5 291.3 3KP6.5 7.22 8.82 5 6.5 2 244 12.3 3KP6.5A 7.22 7.98 5 6.5 2 267.8 11.2 3KP7. 7.78 9.51 5 7. 225.5 13.3 3KP7.A 7.78 8.6 5 7. 25 12. 3KP7.5 8.33.2 7.5 25 29.7 14.3 3KP7.5A 8.33 9.21 7.5 25 232.5 12.9 3KP8. 8.89.9 8. 15 2 1 3KP8.A 8.89 9.83 8. 15 22.6 13.6 3KP8.5 9.44 11.5 8.5 5 188.7 15.9 3KP8.5A 9.44.4 8.5 5 28.3 14.4 3KP9.. 12.2 9. 2 177.5 16.9 3KP9.A. 11.1 9. 2 194.8 15.4 3KP 11.1 13.6. 15 159.6 18.8 3KPA 11.1 12.3. 15 176.4 17. 3KP11 12.2 14.9 11. 149.2 2.1 3KP11A 12.2 13.5 11. 164.8 18.2 3KP12 13.3 16.3 12. 136.4 22. 3KP12A 13.3 14.7 12. 15.7 19.9 3KP13 14.4 17.6 13. 126 23.8 3KP13A 14.4 15.9 13. 139.5 21.5 3KP14 15.6 19.1 14. 116.3 25.8 3KP14A 15.6 17.2 14. 129.3 23.2 3KP15 16.7 2.4 1.5 26.9 3KP15A 16.7 18.5 1 122.9 24.4 3KP16 17.8 21.8 16. 4.2 28.8 3KP16A 17.8 19.7 16. 115.4 26. 3KP17 18.9 23.1 17. 98.4 3.5 3KP17A 18.9 2.9 17. 8.7 27.6 3KP18 2. 24.4 18. 93.2 32.2 3KP18A 2. 22.1 18. 2.7 29.2 3KP2 22.2 27.1 2. 83.8 35.8 3KP2A 22.2 24.5 2. 92.6 32.4 3KP22 24.4 29.8 22. 76.1 39.4 3KP22A 24.4 26.9 22. 84.5 35.5 3KP24 26.7 32.6 24. 69.7 43. 3KP24A 26.7 29.5 24. 77.1 38.9 3KP26 28.9 35.3 26. 64.4 46.6 3KP26A 28.9 31.9 26. 71.2 42.1 3KP28 31.1 38. 28. 59.9 5.1 3KP28A 31.1 34.4 28. 66.1 45.4 3KP3 33.3 4.7 3. 56 53.5 3KP3A 33.3 36.8 3. 62 48.4
TRANSIENT VOLTAGE SUPPRESSORS 3W SERIES TVS DIODES/R-6 ( CASE 12 ) 3W TYPE 3KP33 3KP33A 3KP36 3KP36A 3KP4 3KP4A 3KP43 3KP43A 3KP45 3KP45A 3KP48 3KP48A 3KP51 3KP51A 3KP54 3KP54A 3KP58 3KP58A 3KP6 3KP6A 3KP64 3KP64A 3KP7 3KP7A 3KP75 3KP75A 3KP78 3KP78A 3KP85 3KP85A 3KP9 3KP9A 3KP 3KPA 3KP1 3KP1A Breakdown VBR MAX. @IT (ma) VWM Leakage at VWM ID(uA) Peak Pulse Current (Amps) Clamping at VC 36.7 44.9 33. 5.8 59. 36.7 4.6 33. 56.3 53.3 4. 48.9 36. 46.6 64.3 4. 44.2 36. 51.6 58.1 44.4 54.3 4. 42. 71.4 44.4 49.1 4. 46.5 64.5 47.8 58.4 43. 39.1 76.7 47.8 52.8 43. 43.2 69.4 5. 61.1 4 37.3 8.3 5. 55.3 4 41.3 72.7 53.3 65.2 48. 35.1 85.5 53.3 56.7 56.7 6. 6. 64.4 64.4 58.9 69.3 62.7 73.3 66.3 78.7 71.2 48. 51. 51. 54. 54. 58. 58. 38.7 32.9 36.4 31.2 34.4 29.1 31.9 77.4 91.1 82.4 96.3 87.1 3 94 66.7 66.7 81.5 73.7 6. 6. 28. 3.9 7 97 71.1 71.1 96.9 78.6 64. 64. 26.3 29.1 114 3 77.8 77.8 95.1 86. 7. 7. 24. 26.5 125 113 83.3 83.3 2 92.1 7 7 22.4 24.8 134 121 86.7 86.7 6 95.8 78. 78. 21.6 23.8 139 126 94.4 94.4 115 4 8 8 19.8 21.9 151 137 122 9. 9. 18.7 2.5 16 146 136 123 16.7 18.5 179 162 122 149 1 15.3 196 122 135 1 16.9 177 Notes : 1. V BR measured after I T applied for 3us. I T = square pulse or equivalent. 2. All devices UL listed under file# E296. 3. For bidirectional use C or CA suffixs for all type (ex. 3KPC,3KP1CA) electrical characteristics apply in both directions. 4. For bidirectional types having VWM of volts and less, the ID limit is doubled.
DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.